Program Version:EnergyPlus, Version 23.1.0-87ed9199d4, YMD=2023.09.09 10:58
Tabular Output Report in Format: HTML
Building: -College-ASHRAE 169-2013-2A created: 2023-09-08 18:26:06 +0800
Environment: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 ** SINGAPORE - SGP IWEC Data WMO#=486980
Simulation Timestamp: 2023-09-09 10:58:41
Report: Annual Building Utility Performance Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Values gathered over 8760.00 hours| Total Energy [GJ] | Energy Per Total Building Area [MJ/m2] | Energy Per Conditioned Building Area [MJ/m2] | |
| Total Site Energy | 4059.71 | 632.80 | 637.52 |
| Net Site Energy | 4059.71 | 632.80 | 637.52 |
| Total Source Energy | 12219.01 | 1904.60 | 1918.83 |
| Net Source Energy | 12219.01 | 1904.60 | 1918.83 |
| Site=>Source Conversion Factor | |
| Electricity | 3.167 |
| Natural Gas | 1.084 |
| District Cooling | 1.056 |
| District Heating | 3.613 |
| Steam | 1.200 |
| Gasoline | 1.050 |
| Diesel | 1.050 |
| Coal | 1.050 |
| Fuel Oil No 1 | 1.050 |
| Fuel Oil No 2 | 1.050 |
| Propane | 1.050 |
| Other Fuel 1 | 1.000 |
| Other Fuel 2 | 1.000 |
| Area [m2] | |
| Total Building Area | 6415.51 |
| Net Conditioned Building Area | 6367.95 |
| Unconditioned Building Area | 47.57 |
| Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 783.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 701.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 70.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 1519.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 369.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 193.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 115.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3479.60 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 306.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.99 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 3753.38 | 306.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3678.59 |
| Subcategory | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Cooling | General | 783.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | General | 701.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | General | 70.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | General | 1446.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Elevators | 73.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | VAV System Fans | 369.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | General | 193.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 115.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3479.60 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 306.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.99 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Space Type | Electricity [GJ] | Natural Gas [GJ] | Gasoline [GJ] | Diesel [GJ] | Coal [GJ] | Fuel Oil No 1 [GJ] | Fuel Oil No 2 [GJ] | Propane [GJ] | Other Fuel 1 [GJ] | Other Fuel 2 [GJ] | District Cooling [GJ] | District Heating [GJ] | Water [m3] | |
| Heating | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | Unassigned | 783.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | COLLEGE - LOUNGE | 16.07 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| COLLEGE - CLASSROOM | 161.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - CONFERENCE | 20.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - CORRIDOR | 28.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - OFFICE | 136.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - RESTROOM | 22.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - LABORATORY | 108.93 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - LECTURE HALL | 24.98 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - MEDIA CENTER | 33.99 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - STAIRS | 12.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - STORAGE | 4.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - ART CLASSROOM | 128.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - UTILITY | 2.13 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Lighting | Unassigned | 70.69 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | COLLEGE - LOUNGE | 229.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| COLLEGE - CLASSROOM | 249.27 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - CONFERENCE | 24.60 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - CORRIDOR | 30.30 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - ENTRANCE LOBBY | 4.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - OFFICE | 216.63 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - RESTROOM | 15.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - LABORATORY | 385.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - LECTURE HALL | 44.78 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - MEDIA CENTER | 44.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - ELEVATOR SHAFT | 73.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - ART CLASSROOM | 198.49 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| COLLEGE - UTILITY | 2.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | Unassigned | 369.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | Unassigned | 193.20 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | Unassigned | 115.68 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 3479.60 |
| Humidification | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | Unassigned | 0.00 | 306.33 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 198.99 |
| Refrigeration | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | Unassigned | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 121.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 229.60 | 48.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.58 |
| Other | 238.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 589.42 | 48.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.58 |
| Electricity Intensity [MJ/m2] | Natural Gas Intensity [MJ/m2] | Gasoline Intensity [MJ/m2] | Diesel Intensity [MJ/m2] | Coal Intensity [MJ/m2] | Fuel Oil No 1 Intensity [MJ/m2] | Fuel Oil No 2 Intensity [MJ/m2] | Propane Intensity [MJ/m2] | Other Fuel 1 Intensity [MJ/m2] | Other Fuel 2 Intensity [MJ/m2] | District Cooling Intensity [MJ/m2] | District Heating Intensity [MJ/m2] | Water Intensity [m3/m2] | |
| Lighting | 120.34 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| HVAC | 227.90 | 47.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 |
| Other | 236.81 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total | 585.05 | 47.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.57 |
| Electricity [GJ] | Percent Electricity [%] | |
| Fuel-Fired Power Generation | 0.000 | 0.00 |
| High Temperature Geothermal* | 0.000 | 0.00 |
| Photovoltaic Power | 0.000 | 0.00 |
| Wind Power | 0.000 | 0.00 |
| Power Conversion | 0.000 | 0.00 |
| Net Decrease in On-Site Storage | 0.000 | 0.00 |
| Total On-Site Electric Sources | 0.000 | 0.00 |
| Electricity Coming From Utility | 3753.379 | 100.00 |
| Surplus Electricity Going To Utility | 0.000 | 0.00 |
| Net Electricity From Utility | 3753.379 | 100.00 |
| Total On-Site and Utility Electric Sources | 3753.379 | 100.00 |
| Total Electricity End Uses | 3753.379 | 100.00 |
| Heat [GJ] | Percent Heat [%] | |
| Water-Side Heat Recovery | 0.00 | |
| Air to Air Heat Recovery for Cooling | 0.00 | |
| Air to Air Heat Recovery for Heating | 0.00 | |
| High-Temperature Geothermal* | 0.00 | |
| Solar Water Thermal | 0.00 | |
| Solar Air Thermal | 0.00 | |
| Total On-Site Thermal Sources | 0.00 |
| Water [m3] | Percent Water [%] | |
| Rainwater Collection | 0.00 | 0.00 |
| Condensate Collection | 0.00 | 0.00 |
| Groundwater Well | 0.00 | 0.00 |
| Total On Site Water Sources | 0.00 | 0.00 |
| - | - | - |
| Initial Storage | 0.00 | 0.00 |
| Final Storage | 0.00 | 0.00 |
| Change in Storage | 0.00 | 0.00 |
| - | - | - |
| Water Supplied by Utility | 3678.59 | 100.00 |
| - | - | - |
| Total On Site, Change in Storage, and Utility Water Sources | 3678.59 | 100.00 |
| Total Water End Uses | 3678.59 | 100.00 |
| Degrees [deltaC] | |
| Tolerance for Zone Heating Setpoint Not Met Time | 0.20 |
| Tolerance for Zone Cooling Setpoint Not Met Time | 0.20 |
| Facility [Hours] | |
| Time Setpoint Not Met During Occupied Heating | 0.00 |
| Time Setpoint Not Met During Occupied Cooling | 2275.17 |
| Time Not Comfortable Based on Simple ASHRAE 55-2004 | 283.50 |
Table of Contents
TopBUILDING ENERGY PERFORMANCE - ELECTRICITY
| Meter |BUILDING ENERGY PERFORMANCE - NATURAL GAS
| Meter |BUILDING ENERGY PERFORMANCE - ELECTRICITY PEAK DEMAND
| Meter |BUILDING ENERGY PERFORMANCE - NATURAL GAS PEAK DEMAND
| Meter |Life-Cycle Cost Report
| Entire Facility |Report: Input Verification and Results Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
General| Value | |
| Program Version and Build | EnergyPlus, Version 23.1.0-87ed9199d4, YMD=2023.09.09 10:58 |
| RunPeriod | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 |
| Weather File | SINGAPORE - SGP IWEC Data WMO#=486980 |
| Latitude [deg] | 1.37 |
| Longitude [deg] | 103.98 |
| Elevation [m] | 16.00 |
| Time Zone | 8.00 |
| North Axis Angle [deg] | 0.00 |
| Rotation for Appendix G [deg] | 0.00 |
| Hours Simulated [hrs] | 8760.00 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 2811.62 | 1004.84 | 400.97 | 1004.84 | 400.97 |
| Above Ground Wall Area [m2] | 2811.62 | 1004.84 | 400.97 | 1004.84 | 400.97 |
| Window Opening Area [m2] | 862.81 | 308.61 | 123.24 | 308.09 | 122.87 |
| Gross Window-Wall Ratio [%] | 30.69 | 30.71 | 30.74 | 30.66 | 30.64 |
| Above Ground Window-Wall Ratio [%] | 30.69 | 30.71 | 30.74 | 30.66 | 30.64 |
| Total | North (315 to 45 deg) | East (45 to 135 deg) | South (135 to 225 deg) | West (225 to 315 deg) | |
| Gross Wall Area [m2] | 2772.97 | 1004.84 | 400.97 | 966.19 | 400.97 |
| Above Ground Wall Area [m2] | 2772.97 | 1004.84 | 400.97 | 966.19 | 400.97 |
| Window Opening Area [m2] | 851.02 | 308.61 | 123.24 | 296.30 | 122.87 |
| Gross Window-Wall Ratio [%] | 30.69 | 30.71 | 30.74 | 30.67 | 30.64 |
| Above Ground Window-Wall Ratio [%] | 30.69 | 30.71 | 30.74 | 30.67 | 30.64 |
| Total | |
| Gross Roof Area [m2] | 1603.88 |
| Skylight Area [m2] | 0.00 |
| Skylight-Roof Ratio [%] | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Volume [m3] | Multipliers | Above Ground Gross Wall Area [m2] | Underground Gross Wall Area [m2] | Window Glass Area [m2] | Opening Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | Yes | Yes | 712.31 | 1.00 | 105.07 | 0.00 | 32.29 | 32.29 | 6.3507 | 3.72 | 76.9620 |
| CB_CLASSROOM_1_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 59.78 | 0.00 | 18.29 | 18.29 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_1_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 59.78 | 0.00 | 18.39 | 18.39 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_1_F4 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 68.84 | 0.00 | 21.13 | 21.13 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_2_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.32 | 8.32 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_2_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.36 | 8.36 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_2_F4 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 36.23 | 0.00 | 11.12 | 11.12 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_3_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.32 | 8.32 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_3_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.36 | 8.36 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_3_F4 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 36.23 | 0.00 | 11.11 | 11.11 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_4_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.30 | 8.30 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_4_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.36 | 8.36 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_4_F4 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 36.23 | 0.00 | 11.11 | 11.11 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_5_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.31 | 8.31 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_5_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.35 | 8.35 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_5_F4 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 36.23 | 0.00 | 11.13 | 11.13 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_6_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.27 | 8.27 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_6_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.36 | 8.36 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_6_F4 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 68.84 | 0.00 | 21.16 | 21.16 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_7_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.25 | 8.25 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_7_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 27.17 | 0.00 | 8.36 | 8.36 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_8_F2 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 59.78 | 0.00 | 18.31 | 18.31 | 7.6424 | 1.43 | 9.9997 |
| CB_CLASSROOM_8_F3 ZN | 56.44 | Yes | Yes | 223.63 | 1.00 | 59.78 | 0.00 | 18.39 | 18.39 | 7.6424 | 1.43 | 9.9997 |
| CB_CONFERENCE_ROOM_F1 ZN | 45.99 | Yes | Yes | 182.22 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.4410 | 1.86 | 10.7639 |
| CB_CONFERENCE_ROOM_F2 ZN | 30.66 | Yes | Yes | 121.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.4410 | 1.86 | 10.7639 |
| CB_CONFERENCE_ROOM_F3 ZN | 30.66 | Yes | Yes | 121.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.4410 | 1.86 | 10.7639 |
| CB_CONFERENCE_ROOM_F4 ZN | 30.66 | Yes | Yes | 121.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 10.4410 | 1.86 | 10.7639 |
| CB_CORRIDOR_1_F3 ZN | 31.59 | Yes | Yes | 125.16 | 1.00 | 12.08 | 0.00 | 3.72 | 3.72 | 4.4132 | 3.9826 | |
| CB_CORRIDOR_2_F3 ZN | 61.32 | Yes | Yes | 242.96 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.4132 | 3.9826 | |
| CB_CORRIDOR_F1 ZN | 122.17 | Yes | Yes | 638.69 | 1.00 | 12.08 | 0.00 | 3.69 | 3.69 | 4.4132 | 3.9826 | |
| CB_CORRIDOR_F2 ZN | 92.90 | Yes | Yes | 368.12 | 1.00 | 12.08 | 0.00 | 3.69 | 3.69 | 4.4132 | 3.9826 | |
| CB_CORRIDOR_F4 ZN | 151.43 | Yes | Yes | 600.03 | 1.00 | 12.08 | 0.00 | 3.69 | 3.69 | 4.4132 | 3.9826 | |
| CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 36.23 | 0.00 | 11.14 | 11.14 | 0.0000 | 9.29 | 3.9826 |
| CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.07 | 4.07 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.07 | 4.07 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.06 | 4.06 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.05 | 4.05 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.05 | 4.05 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.06 | 4.06 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.06 | 4.06 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.06 | 4.06 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.09 | 4.09 | 7.9653 | 18.58 | 10.7639 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_LAB_1_F4 ZN | 135.17 | Yes | Yes | 535.61 | 1.00 | 94.81 | 0.00 | 29.08 | 29.08 | 14.3160 | 3.72 | 43.0556 |
| CB_LAB_2_F4 ZN | 135.17 | Yes | Yes | 535.61 | 1.00 | 36.23 | 0.00 | 11.12 | 11.12 | 14.3160 | 3.72 | 43.0556 |
| CB_LAB_3_F4 ZN | 135.17 | Yes | Yes | 535.61 | 1.00 | 36.23 | 0.00 | 11.12 | 11.12 | 14.3160 | 3.72 | 43.0556 |
| CB_LAB_4_F4 ZN | 135.17 | Yes | Yes | 535.61 | 1.00 | 94.81 | 0.00 | 29.10 | 29.10 | 14.3160 | 3.72 | 43.0556 |
| CB_LECTURE_ROOM_1_F1 ZN | 270.35 | Yes | Yes | 1071.23 | 1.00 | 131.04 | 0.00 | 40.31 | 40.31 | 6.5660 | 1.43 | 9.9997 |
| CB_LECTURE_ROOM_2_F1 ZN | 150.50 | Yes | Yes | 596.35 | 1.00 | 105.07 | 0.00 | 32.32 | 32.32 | 7.6424 | 1.43 | 9.9997 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | Yes | Yes | 1071.23 | 1.00 | 131.04 | 0.00 | 40.24 | 40.24 | 8.9340 | 9.29 | 10.0104 |
| CB_MAIN_STAIRS_F1 ZN | 18.58 | Yes | Yes | 73.62 | 1.00 | 12.08 | 0.00 | 3.69 | 3.69 | 5.2743 | 0.0000 | |
| CB_MAIN_STAIRS_F2 ZN | 18.58 | Yes | Yes | 73.62 | 1.00 | 12.08 | 0.00 | 3.66 | 3.66 | 5.2743 | 0.0000 | |
| CB_MAIN_STAIRS_F3 ZN | 18.58 | Yes | Yes | 73.62 | 1.00 | 12.08 | 0.00 | 3.71 | 3.71 | 5.2743 | 0.0000 | |
| CB_MAIN_STAIRS_F4 ZN | 18.58 | Yes | Yes | 73.62 | 1.00 | 12.08 | 0.00 | 3.66 | 3.66 | 5.2743 | 0.0000 | |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.08 | 4.08 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | Yes | Yes | 48.59 | 1.00 | 13.29 | 0.00 | 4.07 | 4.07 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_OPEN_F1 ZN | 194.17 | Yes | Yes | 769.37 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_OPEN_F2 ZN | 209.50 | Yes | Yes | 830.11 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_OPEN_F3 ZN | 209.50 | Yes | Yes | 830.11 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.9653 | 18.58 | 10.7639 |
| CB_OFFICES_OPEN_F4 ZN | 209.50 | Yes | Yes | 830.11 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 7.9653 | 18.58 | 10.7639 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | No | Yes | 47.12 | 1.00 | 9.66 | 0.00 | 2.94 | 2.94 | 0.0000 | 2710.8751 | |
| CB_PUBLIC_ELEVATORS_F2 ZN | 11.89 | No | Yes | 47.12 | 1.00 | 9.66 | 0.00 | 2.94 | 2.94 | 0.0000 | 0.0000 | |
| CB_PUBLIC_ELEVATORS_F3 ZN | 11.89 | No | Yes | 47.12 | 1.00 | 9.66 | 0.00 | 2.97 | 2.97 | 0.0000 | 0.0000 | |
| CB_PUBLIC_ELEVATORS_F4 ZN | 11.89 | No | Yes | 47.12 | 1.00 | 9.66 | 0.00 | 2.94 | 2.94 | 0.0000 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F1 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.73 | 2.73 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F2 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.72 | 2.72 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F3 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.78 | 2.78 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F4 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.73 | 2.73 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F1 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.78 | 2.78 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F2 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.75 | 2.75 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F3 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.79 | 2.79 | 5.2743 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F4 ZN | 12.54 | Yes | Yes | 49.70 | 1.00 | 9.06 | 0.00 | 2.78 | 2.78 | 5.2743 | 0.0000 | |
| CB_STAFF_RESTROOMS_1_F1 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STAFF_RESTROOMS_2_F1 ZN | 9.96 | Yes | Yes | 39.48 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STORAGE_F1 ZN | 75.25 | Yes | Yes | 298.18 | 1.00 | 36.23 | 0.00 | 11.13 | 11.13 | 4.0903 | 0.0000 | |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 19.16 | Yes | Yes | 75.92 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 6.7813 | 3.9826 | |
| CB_STUDIO_1_F2 ZN | 299.61 | Yes | Yes | 1187.18 | 1.00 | 131.04 | 0.00 | 40.20 | 40.20 | 7.6424 | 4.65 | 9.9997 |
| CB_STUDIO_1_F3 ZN | 299.61 | Yes | Yes | 1187.18 | 1.00 | 131.04 | 0.00 | 40.31 | 40.31 | 7.6424 | 4.65 | 9.9997 |
| CB_STUDIO_2_F2 ZN | 299.61 | Yes | Yes | 1187.18 | 1.00 | 131.04 | 0.00 | 40.26 | 40.26 | 7.6424 | 4.65 | 9.9997 |
| CB_STUDIO_2_F3 ZN | 299.61 | Yes | Yes | 1187.18 | 1.00 | 131.04 | 0.00 | 40.29 | 40.29 | 7.6424 | 4.65 | 9.9997 |
| CB_UTILITY_F1 ZN | 8.18 | Yes | Yes | 32.39 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.6285 | 3.9826 | |
| CB_UTILITY_F2 ZN | 8.18 | Yes | Yes | 32.39 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.6285 | 3.9826 | |
| CB_UTILITY_F3 ZN | 8.18 | Yes | Yes | 32.39 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.6285 | 3.9826 | |
| CB_UTILITY_F4 ZN | 8.18 | Yes | Yes | 32.39 | 1.00 | 0.00 | 0.00 | 0.00 | 0.00 | 4.6285 | 3.9826 | |
| Total | 6415.51 | 25575.44 | 2811.62 | 0.00 | 862.81 | 862.81 | 7.7687 | 3.43 | 18.6341 | |||
| Conditioned Total | 6367.95 | 25386.96 | 2772.97 | 0.00 | 851.02 | 851.02 | 7.8268 | 3.40 | 13.7109 | |||
| Unconditioned Total | 47.57 | 188.48 | 38.65 | 0.00 | 11.79 | 11.79 | 0.0000 | 677.7188 | ||||
| Not Part of Total | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Area [m2] | Conditioned (Y/N) | Part of Total Floor Area (Y/N) | Multipliers | Zone Name | Space Type | Radiant/Solar Enclosure Name | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | Tags | |
| CB_CAFE_STUDY_LOUNGE_F1 | 179.77 | Yes | Yes | 1.00 | CB_CAFE_STUDY_LOUNGE_F1 ZN | COLLEGE - LOUNGE | CB_CAFE_STUDY_LOUNGE_F1 | 6.3507 | 3.72 | 76.9620 | |
| CB_CLASSROOM_1_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_1_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_1_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_1_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_1_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_1_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_1_F4 | 75.25 | Yes | Yes | 1.00 | CB_CLASSROOM_1_F4 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_1_F4 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_2_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_2_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_2_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_2_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_2_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_2_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_2_F4 | 75.25 | Yes | Yes | 1.00 | CB_CLASSROOM_2_F4 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_2_F4 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_3_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_3_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_3_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_3_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_3_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_3_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_3_F4 | 75.25 | Yes | Yes | 1.00 | CB_CLASSROOM_3_F4 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_3_F4 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_4_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_4_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_4_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_4_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_4_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_4_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_4_F4 | 75.25 | Yes | Yes | 1.00 | CB_CLASSROOM_4_F4 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_4_F4 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_5_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_5_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_5_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_5_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_5_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_5_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_5_F4 | 75.25 | Yes | Yes | 1.00 | CB_CLASSROOM_5_F4 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_5_F4 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_6_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_6_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_6_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_6_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_6_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_6_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_6_F4 | 75.25 | Yes | Yes | 1.00 | CB_CLASSROOM_6_F4 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_6_F4 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_7_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_7_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_7_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_7_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_7_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_7_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_8_F2 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_8_F2 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_8_F2 | 7.6424 | 1.43 | 9.9997 | |
| CB_CLASSROOM_8_F3 | 56.44 | Yes | Yes | 1.00 | CB_CLASSROOM_8_F3 ZN | COLLEGE - CLASSROOM | CB_CLASSROOM_8_F3 | 7.6424 | 1.43 | 9.9997 | |
| CB_CONFERENCE_ROOM_F1 | 45.99 | Yes | Yes | 1.00 | CB_CONFERENCE_ROOM_F1 ZN | COLLEGE - CONFERENCE | CB_CONFERENCE_ROOM_F1 | 10.4410 | 1.86 | 10.7639 | |
| CB_CONFERENCE_ROOM_F2 | 30.66 | Yes | Yes | 1.00 | CB_CONFERENCE_ROOM_F2 ZN | COLLEGE - CONFERENCE | CB_CONFERENCE_ROOM_F2 | 10.4410 | 1.86 | 10.7639 | |
| CB_CONFERENCE_ROOM_F3 | 30.66 | Yes | Yes | 1.00 | CB_CONFERENCE_ROOM_F3 ZN | COLLEGE - CONFERENCE | CB_CONFERENCE_ROOM_F3 | 10.4410 | 1.86 | 10.7639 | |
| CB_CONFERENCE_ROOM_F4 | 30.66 | Yes | Yes | 1.00 | CB_CONFERENCE_ROOM_F4 ZN | COLLEGE - CONFERENCE | CB_CONFERENCE_ROOM_F4 | 10.4410 | 1.86 | 10.7639 | |
| CB_CORRIDOR_1_F3 | 31.59 | Yes | Yes | 1.00 | CB_CORRIDOR_1_F3 ZN | COLLEGE - CORRIDOR | CB_CORRIDOR_1_F3 | 4.4132 | 0.00 | 3.9826 | |
| CB_CORRIDOR_2_F3 | 61.32 | Yes | Yes | 1.00 | CB_CORRIDOR_2_F3 ZN | COLLEGE - CORRIDOR | CB_CORRIDOR_2_F3 | 4.4132 | 0.00 | 3.9826 | |
| CB_CORRIDOR_F1 | 122.17 | Yes | Yes | 1.00 | CB_CORRIDOR_F1 ZN | COLLEGE - CORRIDOR | CB_CORRIDOR_F1 | 4.4132 | 0.00 | 3.9826 | |
| CB_CORRIDOR_F2 | 92.90 | Yes | Yes | 1.00 | CB_CORRIDOR_F2 ZN | COLLEGE - CORRIDOR | CB_CORRIDOR_F2 | 4.4132 | 0.00 | 3.9826 | |
| CB_CORRIDOR_F4 | 151.43 | Yes | Yes | 1.00 | CB_CORRIDOR_F4 ZN | COLLEGE - CORRIDOR | CB_CORRIDOR_F4 | 4.4132 | 0.00 | 3.9826 | |
| CB_ENTRANCE_LOBBY_F1 | 75.25 | Yes | Yes | 1.00 | CB_ENTRANCE_LOBBY_F1 ZN | COLLEGE - ENTRANCE LOBBY | CB_ENTRANCE_LOBBY_F1 | 0.0000 | 9.29 | 3.9826 | |
| CB_FACULTY_OFFICE_1_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_1_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_1_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_1_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_1_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_1_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_1_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_1_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_1_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_2_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_2_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_2_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_2_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_2_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_2_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_2_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_2_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_2_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_3_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_3_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_3_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_3_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_3_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_3_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_3_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_3_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_3_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_4_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_4_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_4_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_4_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_4_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_4_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_4_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_4_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_4_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_5_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_5_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_5_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_5_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_5_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_5_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_5_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_5_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_5_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_6_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_6_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_6_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_6_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_6_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_6_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_6_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_6_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_6_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_7_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_7_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_7_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_7_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_7_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_7_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_7_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_7_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_7_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_8_F2 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_8_F2 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_8_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_8_F3 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_8_F3 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_8_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_OFFICE_8_F4 | 12.26 | Yes | Yes | 1.00 | CB_FACULTY_OFFICE_8_F4 ZN | COLLEGE - OFFICE | CB_FACULTY_OFFICE_8_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_FACULTY_RESTROOMS_1_F2 | 9.96 | Yes | Yes | 1.00 | CB_FACULTY_RESTROOMS_1_F2 ZN | COLLEGE - RESTROOM | CB_FACULTY_RESTROOMS_1_F2 | 6.7813 | 0.00 | 3.9826 | |
| CB_FACULTY_RESTROOMS_1_F3 | 9.96 | Yes | Yes | 1.00 | CB_FACULTY_RESTROOMS_1_F3 ZN | COLLEGE - RESTROOM | CB_FACULTY_RESTROOMS_1_F3 | 6.7813 | 0.00 | 3.9826 | |
| CB_FACULTY_RESTROOMS_1_F4 | 9.96 | Yes | Yes | 1.00 | CB_FACULTY_RESTROOMS_1_F4 ZN | COLLEGE - RESTROOM | CB_FACULTY_RESTROOMS_1_F4 | 6.7813 | 0.00 | 3.9826 | |
| CB_FACULTY_RESTROOMS_2_F2 | 9.96 | Yes | Yes | 1.00 | CB_FACULTY_RESTROOMS_2_F2 ZN | COLLEGE - RESTROOM | CB_FACULTY_RESTROOMS_2_F2 | 6.7813 | 0.00 | 3.9826 | |
| CB_FACULTY_RESTROOMS_2_F3 | 9.96 | Yes | Yes | 1.00 | CB_FACULTY_RESTROOMS_2_F3 ZN | COLLEGE - RESTROOM | CB_FACULTY_RESTROOMS_2_F3 | 6.7813 | 0.00 | 3.9826 | |
| CB_FACULTY_RESTROOMS_2_F4 | 9.96 | Yes | Yes | 1.00 | CB_FACULTY_RESTROOMS_2_F4 ZN | COLLEGE - RESTROOM | CB_FACULTY_RESTROOMS_2_F4 | 6.7813 | 0.00 | 3.9826 | |
| CB_LAB_1_F4 | 135.17 | Yes | Yes | 1.00 | CB_LAB_1_F4 ZN | COLLEGE - LABORATORY | CB_LAB_1_F4 | 14.3160 | 3.72 | 43.0556 | |
| CB_LAB_2_F4 | 135.17 | Yes | Yes | 1.00 | CB_LAB_2_F4 ZN | COLLEGE - LABORATORY | CB_LAB_2_F4 | 14.3160 | 3.72 | 43.0556 | |
| CB_LAB_3_F4 | 135.17 | Yes | Yes | 1.00 | CB_LAB_3_F4 ZN | COLLEGE - LABORATORY | CB_LAB_3_F4 | 14.3160 | 3.72 | 43.0556 | |
| CB_LAB_4_F4 | 135.17 | Yes | Yes | 1.00 | CB_LAB_4_F4 ZN | COLLEGE - LABORATORY | CB_LAB_4_F4 | 14.3160 | 3.72 | 43.0556 | |
| CB_LECTURE_ROOM_1_F1 | 270.35 | Yes | Yes | 1.00 | CB_LECTURE_ROOM_1_F1 ZN | COLLEGE - LECTURE HALL | CB_LECTURE_ROOM_1_F1 | 6.5660 | 1.43 | 9.9997 | |
| CB_LECTURE_ROOM_2_F1 | 150.50 | Yes | Yes | 1.00 | CB_LECTURE_ROOM_2_F1 ZN | COLLEGE - CLASSROOM | CB_LECTURE_ROOM_2_F1 | 7.6424 | 1.43 | 9.9997 | |
| CB_LIBRARY_MEDIA_CENTER_F1 | 270.35 | Yes | Yes | 1.00 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | COLLEGE - MEDIA CENTER | CB_LIBRARY_MEDIA_CENTER_F1 | 8.9340 | 9.29 | 10.0104 | |
| CB_MAIN_STAIRS_F1 | 18.58 | Yes | Yes | 1.00 | CB_MAIN_STAIRS_F1 ZN | COLLEGE - STAIRS | CB_MAIN_STAIRS_F1 | 5.2743 | 0.00 | 0.0000 | |
| CB_MAIN_STAIRS_F2 | 18.58 | Yes | Yes | 1.00 | CB_MAIN_STAIRS_F2 ZN | COLLEGE - STAIRS | CB_MAIN_STAIRS_F2 | 5.2743 | 0.00 | 0.0000 | |
| CB_MAIN_STAIRS_F3 | 18.58 | Yes | Yes | 1.00 | CB_MAIN_STAIRS_F3 ZN | COLLEGE - STAIRS | CB_MAIN_STAIRS_F3 | 5.2743 | 0.00 | 0.0000 | |
| CB_MAIN_STAIRS_F4 | 18.58 | Yes | Yes | 1.00 | CB_MAIN_STAIRS_F4 ZN | COLLEGE - STAIRS | CB_MAIN_STAIRS_F4 | 5.2743 | 0.00 | 0.0000 | |
| CB_OFFICES_ENCLOSED_1_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_1_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_1_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_2_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_2_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_2_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_3_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_3_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_3_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_4_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_4_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_4_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_5_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_5_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_5_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_6_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_6_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_6_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_7_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_7_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_7_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_ENCLOSED_8_F1 | 12.26 | Yes | Yes | 1.00 | CB_OFFICES_ENCLOSED_8_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_ENCLOSED_8_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_OPEN_F1 | 194.17 | Yes | Yes | 1.00 | CB_OFFICES_OPEN_F1 ZN | COLLEGE - OFFICE | CB_OFFICES_OPEN_F1 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_OPEN_F2 | 209.50 | Yes | Yes | 1.00 | CB_OFFICES_OPEN_F2 ZN | COLLEGE - OFFICE | CB_OFFICES_OPEN_F2 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_OPEN_F3 | 209.50 | Yes | Yes | 1.00 | CB_OFFICES_OPEN_F3 ZN | COLLEGE - OFFICE | CB_OFFICES_OPEN_F3 | 7.9653 | 18.58 | 10.7639 | |
| CB_OFFICES_OPEN_F4 | 209.50 | Yes | Yes | 1.00 | CB_OFFICES_OPEN_F4 ZN | COLLEGE - OFFICE | CB_OFFICES_OPEN_F4 | 7.9653 | 18.58 | 10.7639 | |
| CB_PUBLIC_ELEVATORS_F1 | 11.89 | No | Yes | 1.00 | CB_PUBLIC_ELEVATORS_F1 ZN | COLLEGE - ELEVATOR SHAFT | CB_PUBLIC_ELEVATORS_F1 | 0.0000 | 0.00 | 2710.8751 | |
| CB_PUBLIC_ELEVATORS_F2 | 11.89 | No | Yes | 1.00 | CB_PUBLIC_ELEVATORS_F2 ZN | COLLEGE - ELEVATOR SHAFT | CB_PUBLIC_ELEVATORS_F2 | 0.0000 | 0.00 | 0.0000 | |
| CB_PUBLIC_ELEVATORS_F3 | 11.89 | No | Yes | 1.00 | CB_PUBLIC_ELEVATORS_F3 ZN | COLLEGE - ELEVATOR SHAFT | CB_PUBLIC_ELEVATORS_F3 | 0.0000 | 0.00 | 0.0000 | |
| CB_PUBLIC_ELEVATORS_F4 | 11.89 | No | Yes | 1.00 | CB_PUBLIC_ELEVATORS_F4 ZN | COLLEGE - ELEVATOR SHAFT | CB_PUBLIC_ELEVATORS_F4 | 0.0000 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F1 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_1_F1 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_1_F1 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F2 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_1_F2 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_1_F2 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F3 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_1_F3 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_1_F3 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_1_F4 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_1_F4 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_1_F4 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F1 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_2_F1 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_2_F1 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F2 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_2_F2 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_2_F2 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F3 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_2_F3 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_2_F3 | 5.2743 | 0.00 | 0.0000 | |
| CB_SECONDARY_STAIRS_2_F4 | 12.54 | Yes | Yes | 1.00 | CB_SECONDARY_STAIRS_2_F4 ZN | COLLEGE - STAIRS | CB_SECONDARY_STAIRS_2_F4 | 5.2743 | 0.00 | 0.0000 | |
| CB_STAFF_RESTROOMS_1_F1 | 9.96 | Yes | Yes | 1.00 | CB_STAFF_RESTROOMS_1_F1 ZN | COLLEGE - RESTROOM | CB_STAFF_RESTROOMS_1_F1 | 6.7813 | 0.00 | 3.9826 | |
| CB_STAFF_RESTROOMS_2_F1 | 9.96 | Yes | Yes | 1.00 | CB_STAFF_RESTROOMS_2_F1 ZN | COLLEGE - RESTROOM | CB_STAFF_RESTROOMS_2_F1 | 6.7813 | 0.00 | 3.9826 | |
| CB_STORAGE_F1 | 75.25 | Yes | Yes | 1.00 | CB_STORAGE_F1 ZN | COLLEGE - STORAGE | CB_STORAGE_F1 | 4.0903 | 0.00 | 0.0000 | |
| CB_STUDENTS_RESTROOMS_1_F1 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_1_F1 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_1_F1 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_1_F2 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_1_F2 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_1_F2 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_1_F3 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_1_F3 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_1_F3 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_1_F4 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_1_F4 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_1_F4 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F1 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_2_F1 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_2_F1 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F2 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_2_F2 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_2_F2 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F3 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_2_F3 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_2_F3 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDENTS_RESTROOMS_2_F4 | 19.16 | Yes | Yes | 1.00 | CB_STUDENTS_RESTROOMS_2_F4 ZN | COLLEGE - RESTROOM | CB_STUDENTS_RESTROOMS_2_F4 | 6.7813 | 0.00 | 3.9826 | |
| CB_STUDIO_1_F2 | 299.61 | Yes | Yes | 1.00 | CB_STUDIO_1_F2 ZN | COLLEGE - ART CLASSROOM | CB_STUDIO_1_F2 | 7.6424 | 4.65 | 9.9997 | |
| CB_STUDIO_1_F3 | 299.61 | Yes | Yes | 1.00 | CB_STUDIO_1_F3 ZN | COLLEGE - ART CLASSROOM | CB_STUDIO_1_F3 | 7.6424 | 4.65 | 9.9997 | |
| CB_STUDIO_2_F2 | 299.61 | Yes | Yes | 1.00 | CB_STUDIO_2_F2 ZN | COLLEGE - ART CLASSROOM | CB_STUDIO_2_F2 | 7.6424 | 4.65 | 9.9997 | |
| CB_STUDIO_2_F3 | 299.61 | Yes | Yes | 1.00 | CB_STUDIO_2_F3 ZN | COLLEGE - ART CLASSROOM | CB_STUDIO_2_F3 | 7.6424 | 4.65 | 9.9997 | |
| CB_UTILITY_F1 | 8.18 | Yes | Yes | 1.00 | CB_UTILITY_F1 ZN | COLLEGE - UTILITY | CB_UTILITY_F1 | 4.6285 | 0.00 | 3.9826 | |
| CB_UTILITY_F2 | 8.18 | Yes | Yes | 1.00 | CB_UTILITY_F2 ZN | COLLEGE - UTILITY | CB_UTILITY_F2 | 4.6285 | 0.00 | 3.9826 | |
| CB_UTILITY_F3 | 8.18 | Yes | Yes | 1.00 | CB_UTILITY_F3 ZN | COLLEGE - UTILITY | CB_UTILITY_F3 | 4.6285 | 0.00 | 3.9826 | |
| CB_UTILITY_F4 | 8.18 | Yes | Yes | 1.00 | CB_UTILITY_F4 ZN | COLLEGE - UTILITY | CB_UTILITY_F4 | 4.6285 | 0.00 | 3.9826 | |
| Total | 6415.51 | 7.7687 | 3.43 | 18.6341 | |||||||
| Conditioned Total | 6367.95 | 7.8268 | 3.40 | 13.7109 | |||||||
| Unconditioned Total | 47.57 | 0.0000 | 0.00 | 677.7188 | |||||||
| Not Part of Total | 0.00 | 0.0000 | 0.00 | 0.0000 |
| Total Area [m2] | Conditioned Area [m2] | Unconditioned Area [m2] | Not Part of Total Area [m2] | Lighting [W/m2] | People [m2 per person] | Plug and Process [W/m2] | |
| COLLEGE - LOUNGE | 179.77 | 179.77 | 0.00 | 0.00 | 6.3507 | 3.72 | 76.9620 |
| COLLEGE - CLASSROOM | 1505.03 | 1505.03 | 0.00 | 0.00 | 7.6424 | 1.43 | 9.9997 |
| COLLEGE - CONFERENCE | 137.96 | 137.96 | 0.00 | 0.00 | 10.4410 | 1.86 | 10.7639 |
| COLLEGE - CORRIDOR | 459.41 | 459.41 | 0.00 | 0.00 | 4.4132 | 0.00 | 3.9826 |
| COLLEGE - ENTRANCE LOBBY | 75.25 | 75.25 | 0.00 | 0.00 | 0.0000 | 9.29 | 3.9826 |
| COLLEGE - OFFICE | 1215.08 | 1215.08 | 0.00 | 0.00 | 7.9653 | 18.58 | 10.7639 |
| COLLEGE - RESTROOM | 233.00 | 233.00 | 0.00 | 0.00 | 6.7813 | 0.00 | 3.9826 |
| COLLEGE - LABORATORY | 540.70 | 540.70 | 0.00 | 0.00 | 14.3160 | 3.72 | 43.0556 |
| COLLEGE - LECTURE HALL | 270.35 | 270.35 | 0.00 | 0.00 | 6.5660 | 1.43 | 9.9997 |
| COLLEGE - MEDIA CENTER | 270.35 | 270.35 | 0.00 | 0.00 | 8.9340 | 9.29 | 10.0104 |
| COLLEGE - STAIRS | 174.66 | 174.66 | 0.00 | 0.00 | 5.2743 | 0.00 | 0.0000 |
| COLLEGE - ELEVATOR SHAFT | 47.57 | 0.00 | 47.57 | 0.00 | 0.0000 | 0.00 | 677.7188 |
| COLLEGE - STORAGE | 75.25 | 75.25 | 0.00 | 0.00 | 4.0903 | 0.00 | 0.0000 |
| COLLEGE - ART CLASSROOM | 1198.45 | 1198.45 | 0.00 | 0.00 | 7.6424 | 4.65 | 9.9997 |
| COLLEGE - UTILITY | 32.70 | 32.70 | 0.00 | 0.00 | 4.6285 | 0.00 | 3.9826 |
| Total | 6415.51 | 6367.95 | 47.57 | 0.00 |
Report: Demand End Use Components Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
End Uses| Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Time of Peak | 20-MAR-07:20 | 24-JAN-13:30 | - | - | - | - | - | - | - | - | - | - | 04-APR-13:09 |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 64231.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 44856.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 8993.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 97070.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 50513.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 9770.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 12646.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 28778.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total End Uses | 288081.11 | 28778.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Subcategory | Electricity [W] | Natural Gas [W] | Gasoline [W] | Diesel [W] | Coal [W] | Fuel Oil No 1 [W] | Fuel Oil No 2 [W] | Propane [W] | Other Fuel 1 [W] | Other Fuel 2 [W] | District Cooling [W] | Steam [W] | Water [m3/s] | |
| Heating | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Cooling | General | 64231.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | General | 44856.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | General | 8993.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | General | 87310.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Elevators | 9759.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Exterior Equipment | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | VAV System Fans | 50513.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | General | 9770.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | General | 12646.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | General | 0.00 | 28778.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Source Energy End Use Components Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Values gathered over 8760.00 hours| Source Electricity [GJ] | Source Natural Gas [GJ] | Source Gasoline [GJ] | Source Diesel [GJ] | Source Coal [GJ] | Source Fuel Oil No 1 [GJ] | Source Fuel Oil No 2 [GJ] | Source Propane [GJ] | Source Other Fuel 1 [GJ] | Source Other Fuel 2 [GJ] | Source District Cooling [GJ] | Source District Heating [GJ] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 2481.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 2221.24 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 223.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 4811.40 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 1171.19 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 611.88 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 366.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 332.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 11886.95 | 332.06 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 389.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 348.82 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 35.16 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 755.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 183.92 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 96.09 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 57.53 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 52.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1866.69 | 52.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Source Electricity [MJ/m2] | Source Natural Gas [MJ/m2] | Source Gasoline [MJ/m2] | Source Diesel [MJ/m2] | Source Coal [MJ/m2] | Source Fuel Oil No 1 [MJ/m2] | Source Fuel Oil No 2 [MJ/m2] | Source Propane [MJ/m2] | Source Other Fuel 1 [MJ/m2] | Source Other Fuel 2 [MJ/m2] | Source District Cooling [MJ/m2] | Source District Heating [MJ/m2] | |
| Heating | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling | 386.72 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting | 346.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting | 34.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment | 749.96 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans | 182.56 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps | 95.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection | 57.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems | 0.00 | 51.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Source Energy End Use Components | 1852.85 | 51.76 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Component Sizing Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
AirTerminal:SingleDuct:VAV:Reheat| Design Size Maximum Air Flow Rate [m3/s] | Design Size Constant Minimum Air Flow Fraction | User-Specified Constant Minimum Air Flow Fraction | Design Size Minimum Air Flow Rate [m3/s] | Design Size Maximum Flow Fraction during Reheat [] | User-Specified Maximum Flow Fraction during Reheat [] | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | Design Size Maximum Reheat Water Flow Rate [m3/s] | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | 1.41 | 0.097207 | 0.010000 | 0.014092 | 0.300000 | 0.500000 | 0.003919 | 0.000001 | 0.014092 | 12.78 | 0.008000 |
| CB_CLASSROOM_1_F2 ZN VAV TERMINAL | 0.280583 | 0.153275 | 0.010000 | 0.002806 | 0.504579 | 0.500000 | 0.002486 | 0.000051 | 0.067860 | 12.78 | 0.008000 |
| CB_CLASSROOM_1_F3 ZN VAV TERMINAL | 0.280721 | 0.153199 | 0.010000 | 0.002807 | 0.504330 | 0.500000 | 0.002487 | 0.000054 | 0.072088 | 12.78 | 0.008000 |
| CB_CLASSROOM_1_F4 ZN VAV TERMINAL | 0.427369 | 0.134173 | 0.010000 | 0.004274 | 0.357796 | 0.500000 | 0.002840 | 0.000076 | 0.101638 | 12.78 | 0.008000 |
| CB_CLASSROOM_2_F2 ZN VAV TERMINAL | 0.211039 | 0.203783 | 0.010000 | 0.002110 | 0.670853 | 0.500000 | 0.001870 | 0.000021 | 0.028395 | 12.78 | 0.008000 |
| CB_CLASSROOM_2_F3 ZN VAV TERMINAL | 0.210958 | 0.203862 | 0.010000 | 0.002110 | 0.671112 | 0.500000 | 0.001869 | 0.000023 | 0.030692 | 12.78 | 0.008000 |
| CB_CLASSROOM_2_F4 ZN VAV TERMINAL | 0.313747 | 0.182764 | 0.010000 | 0.003137 | 0.487371 | 0.500000 | 0.002085 | 0.000042 | 0.056008 | 12.78 | 0.008000 |
| CB_CLASSROOM_3_F2 ZN VAV TERMINAL | 0.210586 | 0.204222 | 0.010000 | 0.002106 | 0.672298 | 0.500000 | 0.001866 | 0.000019 | 0.025059 | 12.78 | 0.008000 |
| CB_CLASSROOM_3_F3 ZN VAV TERMINAL | 0.205885 | 0.208885 | 0.010000 | 0.002059 | 0.687648 | 0.500000 | 0.001824 | 0.000020 | 0.026559 | 12.78 | 0.008000 |
| CB_CLASSROOM_3_F4 ZN VAV TERMINAL | 0.305488 | 0.187705 | 0.010000 | 0.003055 | 0.500547 | 0.500000 | 0.002030 | 0.000040 | 0.053270 | 12.78 | 0.008000 |
| CB_CLASSROOM_4_F2 ZN VAV TERMINAL | 0.235043 | 0.182972 | 0.010000 | 0.002350 | 0.602342 | 0.500000 | 0.002082 | 0.000019 | 0.025503 | 12.78 | 0.008000 |
| CB_CLASSROOM_4_F3 ZN VAV TERMINAL | 0.207568 | 0.207191 | 0.010000 | 0.002076 | 0.682073 | 0.500000 | 0.001839 | 0.000021 | 0.027729 | 12.78 | 0.008000 |
| CB_CLASSROOM_4_F4 ZN VAV TERMINAL | 0.312085 | 0.183737 | 0.010000 | 0.003121 | 0.489965 | 0.500000 | 0.002074 | 0.000043 | 0.057136 | 12.78 | 0.008000 |
| CB_CLASSROOM_5_F2 ZN VAV TERMINAL | 0.197489 | 0.217765 | 0.010000 | 0.001975 | 0.716882 | 0.500000 | 0.001750 | 0.000015 | 0.020574 | 12.78 | 0.008000 |
| CB_CLASSROOM_5_F3 ZN VAV TERMINAL | 0.198296 | 0.216878 | 0.010000 | 0.001983 | 0.713963 | 0.500000 | 0.001757 | 0.000018 | 0.024452 | 12.78 | 0.008000 |
| CB_CLASSROOM_5_F4 ZN VAV TERMINAL | 0.313348 | 0.182997 | 0.010000 | 0.003133 | 0.487991 | 0.500000 | 0.002082 | 0.000042 | 0.056615 | 12.78 | 0.008000 |
| CB_CLASSROOM_6_F2 ZN VAV TERMINAL | 0.212098 | 0.202766 | 0.010000 | 0.002121 | 0.667505 | 0.500000 | 0.001879 | 0.000008 | 0.011410 | 12.78 | 0.008000 |
| CB_CLASSROOM_6_F3 ZN VAV TERMINAL | 0.205418 | 0.209359 | 0.010000 | 0.002054 | 0.689210 | 0.500000 | 0.001820 | 0.000018 | 0.024661 | 12.78 | 0.008000 |
| CB_CLASSROOM_6_F4 ZN VAV TERMINAL | 0.380847 | 0.150563 | 0.010000 | 0.003808 | 0.401502 | 0.500000 | 0.002530 | 0.000077 | 0.102939 | 12.78 | 0.008000 |
| CB_CLASSROOM_7_F2 ZN VAV TERMINAL | 0.222576 | 0.193220 | 0.010000 | 0.002226 | 0.636080 | 0.500000 | 0.001972 | 0.000007 | 0.008923 | 12.78 | 0.008000 |
| CB_CLASSROOM_7_F3 ZN VAV TERMINAL | 0.212383 | 0.202494 | 0.010000 | 0.002124 | 0.666608 | 0.500000 | 0.001882 | 0.000021 | 0.028356 | 12.78 | 0.008000 |
| CB_CLASSROOM_8_F2 ZN VAV TERMINAL | 0.318380 | 0.135078 | 0.010000 | 0.003184 | 0.444677 | 0.500000 | 0.002821 | 0.000035 | 0.046835 | 12.78 | 0.008000 |
| CB_CLASSROOM_8_F3 ZN VAV TERMINAL | 0.308931 | 0.139210 | 0.010000 | 0.003089 | 0.458278 | 0.500000 | 0.002737 | 0.000052 | 0.069103 | 12.78 | 0.008000 |
| CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | 0.196653 | 0.719930 | 0.500000 | 0.002138 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | 0.132557 | 1.00 | 0.500000 | 0.002162 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | 0.132311 | 1.00 | 0.500000 | 0.002158 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | 0.151243 | 0.936085 | 0.500000 | 0.002467 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_CORRIDOR_1_F3 ZN VAV TERMINAL | 0.047399 | 0.507799 | 0.080000 | 0.003792 | 1.00 | 0.500000 | 0.000750 | 0.000012 | 0.016646 | 12.78 | 0.008000 |
| CB_CORRIDOR_2_F3 ZN VAV TERMINAL | 0.066009 | 0.707823 | 0.135000 | 0.008911 | 1.00 | 0.500000 | 0.000538 | 0.000001 | 0.008911 | 12.78 | 0.008000 |
| CB_CORRIDOR_F1 ZN VAV TERMINAL | 0.350418 | 0.265659 | 0.051000 | 0.017871 | 0.708423 | 0.500000 | 0.001434 | 0.000004 | 0.017871 | 12.78 | 0.008000 |
| CB_CORRIDOR_F2 ZN VAV TERMINAL | 0.135607 | 0.522039 | 0.095000 | 0.012883 | 1.00 | 0.500000 | 0.000730 | 0.000004 | 0.012883 | 12.78 | 0.008000 |
| CB_CORRIDOR_F4 ZN VAV TERMINAL | 0.275839 | 0.418328 | 0.078000 | 0.021515 | 1.00 | 0.500000 | 0.000911 | 0.000035 | 0.047246 | 12.78 | 0.008000 |
| CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | 0.129825 | 0.441683 | 0.010000 | 0.001298 | 1.00 | 0.500000 | 0.000863 | 0.000020 | 0.027611 | 12.78 | 0.008000 |
| CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | 0.050213 | 1.00 | 0.500000 | 0.002047 | 0.000008 | 0.011396 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | 0.050617 | 1.00 | 0.500000 | 0.002064 | 0.000009 | 0.012242 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | 0.060442 | 1.00 | 0.500000 | 0.002464 | 0.000010 | 0.014046 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | 0.050343 | 1.00 | 0.500000 | 0.002053 | 0.000009 | 0.011763 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | 0.050633 | 1.00 | 0.500000 | 0.002064 | 0.000010 | 0.012927 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | 0.058980 | 1.00 | 0.500000 | 0.002405 | 0.000013 | 0.017247 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | 0.050294 | 1.00 | 0.500000 | 0.002051 | 0.000009 | 0.011784 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | 0.050600 | 1.00 | 0.500000 | 0.002063 | 0.000010 | 0.013009 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | 0.058850 | 1.00 | 0.500000 | 0.002399 | 0.000013 | 0.017605 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | 0.050259 | 1.00 | 0.500000 | 0.002049 | 0.000009 | 0.011772 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | 0.050601 | 1.00 | 0.500000 | 0.002063 | 0.000010 | 0.013022 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | 0.058840 | 1.00 | 0.500000 | 0.002399 | 0.000013 | 0.017645 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | 0.050253 | 1.00 | 0.500000 | 0.002049 | 0.000009 | 0.011769 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | 0.050608 | 1.00 | 0.500000 | 0.002063 | 0.000010 | 0.013026 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | 0.058845 | 1.00 | 0.500000 | 0.002399 | 0.000013 | 0.017647 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | 0.050302 | 1.00 | 0.500000 | 0.002051 | 0.000009 | 0.011786 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | 0.050609 | 1.00 | 0.500000 | 0.002063 | 0.000010 | 0.013013 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | 0.058855 | 1.00 | 0.500000 | 0.002400 | 0.000013 | 0.017607 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | 0.050285 | 1.00 | 0.500000 | 0.002050 | 0.000009 | 0.011719 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | 0.050625 | 1.00 | 0.500000 | 0.002064 | 0.000010 | 0.012917 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | 0.058989 | 1.00 | 0.500000 | 0.002405 | 0.000013 | 0.017245 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | 0.050216 | 1.00 | 0.500000 | 0.002047 | 0.000008 | 0.011227 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | 0.050696 | 1.00 | 0.500000 | 0.002067 | 0.000009 | 0.012189 | 12.78 | 0.008000 | |||
| CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | 0.060503 | 1.00 | 0.500000 | 0.002467 | 0.000010 | 0.014006 | 12.78 | 0.008000 | |||
| CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | 0.010779 | 0.704406 | 0.010000 | 0.000108 | 1.00 | 0.500000 | 0.000541 | 0.000000 | 0.000108 | 12.78 | 0.008000 |
| CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | 0.010371 | 0.732111 | 0.010000 | 0.000104 | 1.00 | 0.500000 | 0.000520 | 0.000000 | 0.000104 | 12.78 | 0.008000 |
| CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | 0.015623 | 0.485979 | 0.010000 | 0.000156 | 1.00 | 0.500000 | 0.000784 | 0.000000 | 0.000156 | 12.78 | 0.008000 |
| CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | 0.010691 | 0.710184 | 0.010000 | 0.000107 | 1.00 | 0.500000 | 0.000536 | 0.000000 | 0.000107 | 12.78 | 0.008000 |
| CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | 0.010793 | 0.703481 | 0.010000 | 0.000108 | 1.00 | 0.500000 | 0.000542 | 0.000000 | 0.000108 | 12.78 | 0.008000 |
| CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | 0.015237 | 0.498277 | 0.010000 | 0.000152 | 1.00 | 0.500000 | 0.000765 | 0.000000 | 0.000152 | 12.78 | 0.008000 |
| CB_LAB_1_F4 ZN VAV TERMINAL | 1.00 | 0.102816 | 0.010000 | 0.010018 | 0.300000 | 0.500000 | 0.003706 | 0.000013 | 0.017453 | 12.78 | 0.008000 |
| CB_LAB_2_F4 ZN VAV TERMINAL | 0.775050 | 0.132898 | 0.010000 | 0.007751 | 0.354394 | 0.500000 | 0.002867 | 0.000001 | 0.007751 | 12.78 | 0.008000 |
| CB_LAB_3_F4 ZN VAV TERMINAL | 0.775091 | 0.132891 | 0.010000 | 0.007751 | 0.354376 | 0.500000 | 0.002867 | 0.000001 | 0.007751 | 12.78 | 0.008000 |
| CB_LAB_4_F4 ZN VAV TERMINAL | 0.939512 | 0.109634 | 0.010000 | 0.009395 | 0.300000 | 0.500000 | 0.003475 | 0.000014 | 0.019791 | 12.78 | 0.008000 |
| CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | 0.986479 | 0.208829 | 0.010000 | 0.009865 | 0.556876 | 0.500000 | 0.001824 | 0.000068 | 0.092579 | 12.78 | 0.008000 |
| CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | 0.588563 | 0.194853 | 0.010000 | 0.005886 | 0.519608 | 0.500000 | 0.001955 | 0.000072 | 0.096542 | 12.78 | 0.008000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | 0.791277 | 0.260345 | 0.137000 | 0.108405 | 0.694254 | 0.500000 | 0.001463 | 0.000053 | 0.108405 | 12.78 | 0.008000 |
| CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | 0.030675 | 0.461565 | 0.071000 | 0.002178 | 1.00 | 0.500000 | 0.000825 | 0.000009 | 0.012167 | 12.78 | 0.008000 |
| CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | 0.028589 | 0.495241 | 0.073000 | 0.002087 | 1.00 | 0.500000 | 0.000769 | 0.000010 | 0.013893 | 12.78 | 0.008000 |
| CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | 0.028616 | 0.494773 | 0.073000 | 0.002089 | 1.00 | 0.500000 | 0.000770 | 0.000012 | 0.016566 | 12.78 | 0.008000 |
| CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | 0.038235 | 0.370302 | 0.057000 | 0.002179 | 1.00 | 0.500000 | 0.001029 | 0.000015 | 0.020578 | 12.78 | 0.008000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | 0.049072 | 1.00 | 0.500000 | 0.002001 | 0.000007 | 0.009756 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | 0.048866 | 1.00 | 0.500000 | 0.001992 | 0.000007 | 0.009986 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | 0.048832 | 1.00 | 0.500000 | 0.001991 | 0.000007 | 0.010009 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | 0.048829 | 1.00 | 0.500000 | 0.001991 | 0.000007 | 0.010012 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | 0.048825 | 1.00 | 0.500000 | 0.001991 | 0.000007 | 0.010009 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | 0.048822 | 1.00 | 0.500000 | 0.001991 | 0.000007 | 0.010002 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | 0.048828 | 1.00 | 0.500000 | 0.001991 | 0.000007 | 0.009956 | 12.78 | 0.008000 | |||
| CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | 0.048739 | 1.00 | 0.500000 | 0.001987 | 0.000007 | 0.009509 | 12.78 | 0.008000 | |||
| CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | 0.351163 | 1.00 | 0.500000 | 0.000904 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | 0.380369 | 1.00 | 0.500000 | 0.000908 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | 0.383774 | 1.00 | 0.500000 | 0.000916 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | 0.484907 | 0.877893 | 0.500000 | 0.001157 | 0.000000 | 0.000000 | 12.78 | 0.008000 | |||
| CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | 0.051926 | 0.184048 | 0.035000 | 0.001817 | 1.00 | 0.500000 | 0.002070 | 0.000001 | 0.001817 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | 0.049470 | 0.193188 | 0.037000 | 0.001830 | 1.00 | 0.500000 | 0.001972 | 0.000008 | 0.011330 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | 0.049824 | 0.191815 | 0.037000 | 0.001843 | 1.00 | 0.500000 | 0.001986 | 0.000010 | 0.013314 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | 0.060957 | 0.156781 | 0.030000 | 0.001829 | 1.00 | 0.500000 | 0.002430 | 0.000012 | 0.016158 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | 0.040689 | 0.234879 | 0.046000 | 0.001872 | 1.00 | 0.500000 | 0.001622 | 0.000008 | 0.011273 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | 0.043779 | 0.218301 | 0.042000 | 0.001839 | 1.00 | 0.500000 | 0.001745 | 0.000010 | 0.013382 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | 0.044221 | 0.216118 | 0.042000 | 0.001857 | 1.00 | 0.500000 | 0.001763 | 0.000010 | 0.013844 | 12.78 | 0.008000 |
| CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | 0.054876 | 0.174154 | 0.035000 | 0.001921 | 1.00 | 0.500000 | 0.002188 | 0.000012 | 0.016495 | 12.78 | 0.008000 |
| CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | 0.010766 | 0.705239 | 0.010000 | 0.000108 | 1.00 | 0.500000 | 0.000540 | 0.000000 | 0.000108 | 12.78 | 0.008000 |
| CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | 0.012020 | 0.631645 | 0.010000 | 0.000120 | 1.00 | 0.500000 | 0.000603 | 0.000000 | 0.000120 | 12.78 | 0.008000 |
| CB_STORAGE_F1 ZN VAV TERMINAL | 0.343949 | 0.166716 | 0.010000 | 0.003439 | 0.444575 | 0.500000 | 0.002285 | 0.000013 | 0.017813 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | 0.020574 | 0.709691 | 0.010000 | 0.000206 | 1.00 | 0.500000 | 0.000537 | 0.000000 | 0.000206 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | 0.019264 | 0.757951 | 0.010000 | 0.000193 | 1.00 | 0.500000 | 0.000503 | 0.000000 | 0.000193 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | 0.018966 | 0.769829 | 0.010000 | 0.000190 | 1.00 | 0.500000 | 0.000495 | 0.000000 | 0.000190 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | 0.027544 | 0.530091 | 0.010000 | 0.000275 | 1.00 | 0.500000 | 0.000719 | 0.000000 | 0.000275 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | 0.023471 | 0.622087 | 0.010000 | 0.000235 | 1.00 | 0.500000 | 0.000612 | 0.000000 | 0.000235 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | 0.021956 | 0.665016 | 0.010000 | 0.000220 | 1.00 | 0.500000 | 0.000573 | 0.000000 | 0.000220 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | 0.021887 | 0.667109 | 0.010000 | 0.000219 | 1.00 | 0.500000 | 0.000571 | 0.000000 | 0.000219 | 12.78 | 0.008000 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | 0.032817 | 0.444918 | 0.010000 | 0.000328 | 1.00 | 0.500000 | 0.000856 | 0.000000 | 0.000328 | 12.78 | 0.008000 |
| CB_STUDIO_1_F2 ZN VAV TERMINAL | 0.915034 | 0.249504 | 0.010000 | 0.009150 | 0.665344 | 0.500000 | 0.001527 | 0.000061 | 0.082101 | 12.78 | 0.008000 |
| CB_STUDIO_1_F3 ZN VAV TERMINAL | 0.828287 | 0.275635 | 0.010000 | 0.008283 | 0.735025 | 0.500000 | 0.001382 | 0.000068 | 0.091453 | 12.78 | 0.008000 |
| CB_STUDIO_2_F2 ZN VAV TERMINAL | 0.806285 | 0.283156 | 0.010000 | 0.008063 | 0.755084 | 0.500000 | 0.001346 | 0.000074 | 0.099556 | 12.78 | 0.008000 |
| CB_STUDIO_2_F3 ZN VAV TERMINAL | 0.933015 | 0.244696 | 0.010000 | 0.009330 | 0.652521 | 0.500000 | 0.001557 | 0.000063 | 0.085472 | 12.78 | 0.008000 |
| CB_UTILITY_F1 ZN VAV TERMINAL | 0.106218 | 0.058650 | 0.012000 | 0.001275 | 1.00 | 0.500000 | 0.006496 | 0.000001 | 0.001275 | 12.78 | 0.008000 |
| CB_UTILITY_F2 ZN VAV TERMINAL | 0.023966 | 0.259944 | 0.048000 | 0.001150 | 1.00 | 0.500000 | 0.001466 | 0.000001 | 0.001361 | 12.78 | 0.008000 |
| CB_UTILITY_F3 ZN VAV TERMINAL | 0.012569 | 0.495650 | 0.089000 | 0.001119 | 1.00 | 0.500000 | 0.000769 | 0.000002 | 0.002124 | 12.78 | 0.008000 |
| CB_UTILITY_F4 ZN VAV TERMINAL | 0.016321 | 0.381706 | 0.069000 | 0.001126 | 1.00 | 0.500000 | 0.000998 | 0.000003 | 0.004350 | 12.78 | 0.008000 |
| Design Size Rated Capacity [W] | Design Size Maximum Water Flow Rate [m3/s] | Design Size U-Factor Times Area Value [W/K] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | 47.98 | 0.000001 | 0.777683 |
| CB_CLASSROOM_1_F2 ZN REHEAT COIL | 2322.42 | 0.000051 | 48.60 |
| CB_CLASSROOM_1_F3 ZN REHEAT COIL | 2469.41 | 0.000054 | 51.69 |
| CB_CLASSROOM_1_F4 ZN REHEAT COIL | 3495.13 | 0.000076 | 73.25 |
| CB_CLASSROOM_2_F2 ZN REHEAT COIL | 962.56 | 0.000021 | 20.08 |
| CB_CLASSROOM_2_F3 ZN REHEAT COIL | 1040.99 | 0.000023 | 21.72 |
| CB_CLASSROOM_2_F4 ZN REHEAT COIL | 1909.95 | 0.000042 | 39.92 |
| CB_CLASSROOM_3_F2 ZN REHEAT COIL | 848.00 | 0.000019 | 17.68 |
| CB_CLASSROOM_3_F3 ZN REHEAT COIL | 899.29 | 0.000020 | 18.76 |
| CB_CLASSROOM_3_F4 ZN REHEAT COIL | 1815.09 | 0.000040 | 37.93 |
| CB_CLASSROOM_4_F2 ZN REHEAT COIL | 862.85 | 0.000019 | 17.99 |
| CB_CLASSROOM_4_F3 ZN REHEAT COIL | 938.95 | 0.000021 | 19.58 |
| CB_CLASSROOM_4_F4 ZN REHEAT COIL | 1947.87 | 0.000043 | 40.71 |
| CB_CLASSROOM_5_F2 ZN REHEAT COIL | 694.83 | 0.000015 | 14.48 |
| CB_CLASSROOM_5_F3 ZN REHEAT COIL | 827.20 | 0.000018 | 17.25 |
| CB_CLASSROOM_5_F4 ZN REHEAT COIL | 1931.03 | 0.000042 | 40.37 |
| CB_CLASSROOM_6_F2 ZN REHEAT COIL | 383.01 | 0.000008 | 7.97 |
| CB_CLASSROOM_6_F3 ZN REHEAT COIL | 834.33 | 0.000018 | 17.40 |
| CB_CLASSROOM_6_F4 ZN REHEAT COIL | 3540.88 | 0.000077 | 74.21 |
| CB_CLASSROOM_7_F2 ZN REHEAT COIL | 299.08 | 0.000007 | 6.22 |
| CB_CLASSROOM_7_F3 ZN REHEAT COIL | 960.83 | 0.000021 | 20.04 |
| CB_CLASSROOM_8_F2 ZN REHEAT COIL | 1590.30 | 0.000035 | 33.20 |
| CB_CLASSROOM_8_F3 ZN REHEAT COIL | 2365.08 | 0.000052 | 49.49 |
| CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_CORRIDOR_1_F3 ZN REHEAT COIL | 562.90 | 0.000012 | 11.74 |
| CB_CORRIDOR_2_F3 ZN REHEAT COIL | 30.34 | 0.000001 | 0.491783 |
| CB_CORRIDOR_F1 ZN REHEAT COIL | 192.65 | 0.000004 | 3.37 |
| CB_CORRIDOR_F2 ZN REHEAT COIL | 188.54 | 0.000004 | 3.42 |
| CB_CORRIDOR_F4 ZN REHEAT COIL | 1593.57 | 0.000035 | 33.20 |
| CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | 932.28 | 0.000020 | 19.43 |
| CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | 386.25 | 0.000008 | 8.06 |
| CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | 415.26 | 0.000009 | 8.67 |
| CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | 477.47 | 0.000010 | 9.97 |
| CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | 398.94 | 0.000009 | 8.32 |
| CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | 438.87 | 0.000010 | 9.16 |
| CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | 588.71 | 0.000013 | 12.31 |
| CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | 399.66 | 0.000009 | 8.34 |
| CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | 441.71 | 0.000010 | 9.22 |
| CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | 601.25 | 0.000013 | 12.57 |
| CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | 399.26 | 0.000009 | 8.33 |
| CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | 442.17 | 0.000010 | 9.23 |
| CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | 602.67 | 0.000013 | 12.60 |
| CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | 399.16 | 0.000009 | 8.33 |
| CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | 442.30 | 0.000010 | 9.23 |
| CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | 602.75 | 0.000013 | 12.61 |
| CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | 399.74 | 0.000009 | 8.34 |
| CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | 441.84 | 0.000010 | 9.22 |
| CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | 601.31 | 0.000013 | 12.57 |
| CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | 397.42 | 0.000009 | 8.29 |
| CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | 438.51 | 0.000010 | 9.15 |
| CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | 588.61 | 0.000013 | 12.31 |
| CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | 380.43 | 0.000008 | 7.94 |
| CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | 413.40 | 0.000009 | 8.63 |
| CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | 476.10 | 0.000010 | 9.94 |
| CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_LAB_1_F4 ZN REHEAT COIL | 584.08 | 0.000013 | 12.14 |
| CB_LAB_2_F4 ZN REHEAT COIL | 26.39 | 0.000001 | 0.427726 |
| CB_LAB_3_F4 ZN REHEAT COIL | 26.39 | 0.000001 | 0.427748 |
| CB_LAB_4_F4 ZN REHEAT COIL | 662.66 | 0.000014 | 13.77 |
| CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | 3128.02 | 0.000068 | 65.20 |
| CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | 3281.34 | 0.000072 | 68.52 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | 2445.03 | 0.000053 | 46.58 |
| CB_MAIN_STAIRS_F1 ZN REHEAT COIL | 411.42 | 0.000009 | 8.58 |
| CB_MAIN_STAIRS_F2 ZN REHEAT COIL | 470.70 | 0.000010 | 9.82 |
| CB_MAIN_STAIRS_F3 ZN REHEAT COIL | 562.85 | 0.000012 | 11.75 |
| CB_MAIN_STAIRS_F4 ZN REHEAT COIL | 701.80 | 0.000015 | 14.67 |
| CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | 329.84 | 0.000007 | 6.88 |
| CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | 337.72 | 0.000007 | 7.04 |
| CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | 338.52 | 0.000007 | 7.06 |
| CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | 338.62 | 0.000007 | 7.06 |
| CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | 338.53 | 0.000007 | 7.06 |
| CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | 338.28 | 0.000007 | 7.05 |
| CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | 336.69 | 0.000007 | 7.02 |
| CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | 321.39 | 0.000007 | 6.70 |
| CB_OFFICES_OPEN_F1 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_OFFICES_OPEN_F2 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_OFFICES_OPEN_F3 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_OFFICES_OPEN_F4 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | 27.78 | 0.000001 | 0.505356 |
| CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | 384.20 | 0.000008 | 8.02 |
| CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | 452.53 | 0.000010 | 9.45 |
| CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | 551.13 | 0.000012 | 11.52 |
| CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | 381.94 | 0.000008 | 7.97 |
| CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | 454.98 | 0.000010 | 9.50 |
| CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | 470.80 | 0.000010 | 9.83 |
| CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | 562.94 | 0.000012 | 11.77 |
| CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STORAGE_F1 ZN REHEAT COIL | 597.53 | 0.000013 | 12.43 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | 0.000000 | 0.000000 | 1.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | 1.12 | 0.000000 | 1.00 |
| CB_STUDIO_1_F2 ZN REHEAT COIL | 2768.57 | 0.000061 | 57.67 |
| CB_STUDIO_1_F3 ZN REHEAT COIL | 3091.09 | 0.000068 | 64.44 |
| CB_STUDIO_2_F2 ZN REHEAT COIL | 3364.83 | 0.000074 | 70.14 |
| CB_STUDIO_2_F3 ZN REHEAT COIL | 2887.02 | 0.000063 | 60.17 |
| CB_UTILITY_F1 ZN REHEAT COIL | 30.85 | 0.000001 | 0.594790 |
| CB_UTILITY_F2 ZN REHEAT COIL | 45.62 | 0.000001 | 0.948504 |
| CB_UTILITY_F3 ZN REHEAT COIL | 71.34 | 0.000002 | 1.48 |
| CB_UTILITY_F4 ZN REHEAT COIL | 146.95 | 0.000003 | 3.06 |
| VAV_1 MAIN HTG COIL | 1836.26 | 0.000040 | 28.69 |
| VAV_2 MAIN HTG COIL | 4167.51 | 0.000091 | 64.72 |
| VAV_3 MAIN HTG COIL | 4357.77 | 0.000095 | 67.64 |
| VAV_4 MAIN HTG COIL | 3631.30 | 0.000079 | 56.62 |
| Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | Sum of Air Terminal Maximum Flow Rates [m3/s] | Adjusted Heating Design Air Flow Rate [m3/s] | Adjusted Cooling Design Air Flow Rate [m3/s] | Adjusted Main Design Air Flow Rate [m3/s] | User Heating Air Flow Ratio [] | Calculated Heating Air Flow Ratio [] | Design Supply Air Flow Rate [m3/s] | |
| VAV_1 | 2.94 | 0.352598 | 5.83 | 0.526832 | 5.61 | 5.61 | 0.300000 | 0.093849 | 5.61 |
| VAV_2 | 2.45 | 0.202585 | 4.87 | 0.639951 | 4.79 | 4.79 | 0.300000 | 0.133481 | 4.79 |
| VAV_3 | 2.43 | 0.202115 | 4.82 | 0.732751 | 4.75 | 4.75 | 0.300000 | 0.154253 | 4.75 |
| VAV_4 | 3.60 | 0.231085 | 7.19 | 0.783840 | 7.02 | 7.02 | 0.300000 | 0.111588 | 7.02 |
| Maximum Outdoor Air Flow Rate [m3/s] | |
| VAV_1 OA CONTROLLER | 5.61 |
| VAV_2 OA CONTROLLER | 4.79 |
| VAV_3 OA CONTROLLER | 4.75 |
| VAV_4 OA CONTROLLER | 7.02 |
| Design Size Design Inlet Air Temperature [C] | Design Size Design Inlet Water Temperature [C] | Design Size Design Outlet Air Temperature [C] | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | Design Size Design Coil Load [W] | Design Size Design Water Flow Rate [m3/s] | Design Size Design Air Flow Rate [m3/s] | |
| VAV_1 CLG COIL | 24.37 | 6.67 | 10.91 | 0.009547 | 0.008500 | 110731.60 | 0.004701 | 5.61 |
| VAV_2 CLG COIL | 24.17 | 6.67 | 10.90 | 0.009591 | 0.008500 | 94101.46 | 0.003995 | 4.79 |
| VAV_3 CLG COIL | 24.18 | 6.67 | 10.90 | 0.009608 | 0.008500 | 93505.25 | 0.003970 | 4.75 |
| VAV_4 CLG COIL | 24.10 | 6.67 | 10.92 | 0.009208 | 0.008500 | 128788.38 | 0.005468 | 7.02 |
| Design Size Maximum Flow Rate [m3/s] | |
| VAV_1 FAN | 5.61 |
| VAV_2 FAN | 4.79 |
| VAV_3 FAN | 4.75 |
| VAV_4 FAN | 7.02 |
| Maximum Actuated Flow [m3/s] | Controller Convergence Tolerance | |
| VAV_1 CLG COIL CONTROLLER | 0.004701 | 0.000101 |
| VAV_1 MAIN HTG COIL CONTROLLER | 0.000040 | |
| VAV_2 CLG COIL CONTROLLER | 0.003995 | 0.000119 |
| VAV_2 MAIN HTG COIL CONTROLLER | 0.000091 | |
| VAV_3 CLG COIL CONTROLLER | 0.003970 | 0.000120 |
| VAV_3 MAIN HTG COIL CONTROLLER | 0.000095 | |
| VAV_4 CLG COIL CONTROLLER | 0.005468 | 0.000087 |
| VAV_4 MAIN HTG COIL CONTROLLER | 0.000079 |
| Initial Design Flow Rate [m3/s] | Initial Design Power Consumption [W] | Design Flow Rate [m3/s] | Design Power Consumption [W] | |
| CHILLED WATER LOOP SECONDARY PUMP | 0.018135 | 3456.18 | 0.018135 | 3456.18 |
| HOT WATER LOOP PUMP | 0.002033 | 534.40 | 0.002033 | 534.40 |
| Initial Maximum Loop Flow Rate [m3/s] | Initial Plant Loop Volume [m3] | Maximum Loop Flow Rate [m3/s] | Plant Loop Volume [m3] | |
| CHILLED WATER LOOP | 0.018135 | 2.18 | 0.018135 | 2.18 |
| CONDENSER WATER LOOP | 0.021585 | 2.59 | 0.024823 | 2.98 |
| HOT WATER LOOP | 0.002033 | 0.243905 | 0.002033 | 0.243905 |
| MAIN SERVICE WATER LOOP | 0.000037 | 0.004391 | 0.000037 | 0.004391 |
| Initial Design Flow Rate [m3/s] | Initial Design Power Consumption [W] | Design Flow Rate [m3/s] | Design Power Consumption [W] | |
| CHILLED WATER LOOP PRIMARY PUMP | 0.018135 | 1192.02 | 0.018135 | 1192.02 |
| CONDENSER WATER LOOP CONSTANT PUMP | 0.021585 | 4434.41 | 0.024823 | 5099.58 |
| MAIN SERVICE WATER LOOP CIRCULATOR PUMP | 0.000037 | 2.00 | 0.000037 | 2.00 |
| Initial Design Size Reference Chilled Water Flow Rate [m3/s] | Initial Design Size Reference Capacity [W] | Initial Design Size Reference Condenser Fluid Flow Rate [m3/s] | Design Size Reference Chilled Water Flow Rate [m3/s] | Design Size Reference Capacity [W] | Design Size Reference Condenser Fluid Flow Rate [m3/s] | |
| 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | 0.018135 | 427126.69 | 0.021585 | 0.018135 | 427126.69 | 0.021585 |
| Initial Design Water Flow Rate [m3/s] | Initial Design Air Flow Rate [m3/s] | Initial Nominal Capacity [W] | Initial Air Flow Rate in free convection regime [m3/s] | Initial Tower capacity in free convection regime at design conditions [W] | Design Water Flow Rate [m3/s] | Design Air Flow Rate [m3/s] | Nominal Capacity [W] | Air Flow Rate in free convection regime [m3/s] | Tower capacity in free convection regime at design conditions [W] | |
| CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | 0.021585 | 36.45 | 498252.51 | 7.29 | 62281.56 | 0.024823 | 36.45 | 572990.39 | 7.29 | 71623.80 |
| Initial Design Size Nominal Capacity [W] | Initial Design Size Design Water Flow Rate [m3/s] | Design Size Nominal Capacity [W] | Design Size Design Water Flow Rate [m3/s] | |
| BOILER 551KBTU/HR 0.8 THERMAL EFF | 92925.44 | 0.002033 | 92925.44 | 0.002033 |
| Initial Use Side Design Flow Rate [m3/s] | Use Side Design Flow Rate [m3/s] | |
| 300GAL NATURAL GAS WATER HEATER - 300KBTU/HR 0.804 THERM EFF | 0.000037 | 0.000037 |
Report: Surface Shadowing Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Surfaces (Walls, Roofs, etc) that may be Shadowed by Other Surfaces| None |
| Possible Shadow Receivers | |
| SURFACE 6 | SUB SURFACE 58 | |
| SURFACE 7 | SUB SURFACE 12 | |
| SURFACE 777 | SUB SURFACE 23 | |
| SURFACE 781 | SUB SURFACE 40 | |
| SURFACE 960 | SUB SURFACE 100 | |
| SURFACE 961 | SUB SURFACE 97 | |
| SURFACE 451 | SUB SURFACE 33 | |
| SURFACE 453 | SUB SURFACE 10 | |
| SURFACE 773 | SUB SURFACE 22 | |
| SURFACE 785 | SUB SURFACE 94 | |
| SURFACE 485 | SUB SURFACE 34 | |
| SURFACE 764 | SUB SURFACE 21 | |
| SURFACE 751 | SUB SURFACE 91 | |
| SURFACE 489 | SUB SURFACE 35 | |
| SURFACE 759 | SUB SURFACE 20 | |
| SURFACE 744 | SUB SURFACE 88 | |
| SURFACE 519 | SUB SURFACE 36 | |
| SURFACE 729 | SUB SURFACE 16 | |
| SURFACE 503 | SUB SURFACE 76 | |
| SURFACE 524 | SUB SURFACE 37 | |
| SURFACE 704 | SUB SURFACE 15 | |
| SURFACE 297 | SUB SURFACE 75 | |
| SURFACE 530 | SUB SURFACE 38 | |
| SURFACE 534 | SUB SURFACE 66 | |
| SURFACE 696 | SUB SURFACE 14 | |
| SURFACE 271 | SUB SURFACE 73 | |
| SURFACE 691 | SUB SURFACE 13 | |
| SURFACE 692 | SUB SURFACE 9 | |
| SURFACE 264 | SUB SURFACE 70 | |
| SURFACE 265 | SUB SURFACE 67 | |
| SURFACE 536 | SUB SURFACE 82 | |
| SURFACE 23 | SUB SURFACE 29 | |
| SURFACE 716 | SUB SURFACE 18 | |
| SURFACE 460 | SUB SURFACE 27 | |
| SURFACE 227 | SUB SURFACE 60 | |
| SURFACE 930 | SUB SURFACE 44 | |
| SURFACE 1110 | SUB SURFACE 7 | |
| SURFACE 685 | SUB SURFACE 78 | |
| SURFACE 922 | SUB SURFACE 45 | |
| SURFACE 1104 | SUB SURFACE 11 | |
| SURFACE 677 | SUB SURFACE 83 | |
| SURFACE 918 | SUB SURFACE 46 | |
| SURFACE 1098 | SUB SURFACE 25 | |
| SURFACE 673 | SUB SURFACE 84 | |
| SURFACE 910 | SUB SURFACE 47 | |
| SURFACE 1092 | SUB SURFACE 28 | |
| SURFACE 665 | SUB SURFACE 89 | |
| SURFACE 906 | SUB SURFACE 48 | |
| SURFACE 1086 | SUB SURFACE 31 | |
| SURFACE 661 | SUB SURFACE 90 | |
| SURFACE 898 | SUB SURFACE 49 | |
| SURFACE 1080 | SUB SURFACE 39 | |
| SURFACE 653 | SUB SURFACE 95 | |
| SURFACE 894 | SUB SURFACE 50 | |
| SURFACE 1074 | SUB SURFACE 57 | |
| SURFACE 649 | SUB SURFACE 96 | |
| SURFACE 885 | SUB SURFACE 51 | |
| SURFACE 1070 | SUB SURFACE 59 | |
| SURFACE 641 | SUB SURFACE 101 | |
| SURFACE 560 | SUB SURFACE 56 | |
| SURFACE 564 | SUB SURFACE 2 | |
| SURFACE 567 | SUB SURFACE 55 | |
| SURFACE 625 | SUB SURFACE 54 | |
| SURFACE 631 | SUB SURFACE 53 | |
| SURFACE 632 | SUB SURFACE 72 | |
| SURFACE 145 | SUB SURFACE 74 | |
| SURFACE 151 | SUB SURFACE 77 | |
| SURFACE 61 | SUB SURFACE 68 | |
| SURFACE 62 | SUB SURFACE 65 | |
| SURFACE 91 | SUB SURFACE 4 | |
| SURFACE 92 | SUB SURFACE 104 | |
| SURFACE 33 | SUB SURFACE 26 | |
| SURFACE 739 | SUB SURFACE 17 | |
| SURFACE 510 | SUB SURFACE 79 | |
| SURFACE 499 | SUB SURFACE 24 | |
| SURFACE 205 | SUB SURFACE 80 | |
| SURFACE 197 | SUB SURFACE 81 | |
| SURFACE 193 | SUB SURFACE 86 | |
| SURFACE 185 | SUB SURFACE 87 | |
| SURFACE 181 | SUB SURFACE 92 | |
| SURFACE 173 | SUB SURFACE 93 | |
| SURFACE 169 | SUB SURFACE 98 | |
| SURFACE 161 | SUB SURFACE 99 | |
| SURFACE 37 | SUB SURFACE 32 | |
| SURFACE 942 | SUB SURFACE 19 | |
| SURFACE 211 | SUB SURFACE 85 | |
| SURFACE 938 | SUB SURFACE 30 | |
| SURFACE 79 | SUB SURFACE 8 | |
| SURFACE 812 | SUB SURFACE 5 | |
| SURFACE 966 | SUB SURFACE 64 | |
| SURFACE 551 | SUB SURFACE 6 | |
| SURFACE 85 | SUB SURFACE 71 | |
| SURFACE 831 | SUB SURFACE 41 | |
| SURFACE 1011 | SUB SURFACE 102 | |
| SURFACE 557 | SUB SURFACE 69 | |
| SURFACE 51 | SUB SURFACE 62 | |
| SURFACE 797 | SUB SURFACE 1 | |
| SURFACE 798 | SUB SURFACE 52 | |
| SURFACE 998 | SUB SURFACE 3 | |
| SURFACE 999 | SUB SURFACE 103 | |
| SURFACE 819 | SUB SURFACE 43 | |
| SURFACE 820 | SUB SURFACE 42 | |
| SURFACE 977 | SUB SURFACE 63 | |
| SURFACE 978 | SUB SURFACE 61 | |
Report: Adaptive Comfort Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Time Not Meeting the Adaptive Comfort Models during Occupied Hours| ASHRAE55 90% Acceptability Limits [Hours] | ASHRAE55 80% Acceptability Limits [Hours] | CEN15251 Category I Acceptability Limits [Hours] | CEN15251 Category II Acceptability Limits [Hours] | CEN15251 Category III Acceptability Limits [Hours] |
Report: Initialization Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Version| Version ID | |
| 1 | 23.1 |
| #TimeSteps | Minutes per TimeStep {minutes} | |
| 1 | 6 | 10 |
| Minimum System TimeStep {minutes} | Max HVAC Iterations | Minimum Plant Iterations | Maximum Plant Iterations | |
| 1 | 1 | 20 | 2 | 8 |
| Do Zone Sizing | Do System Sizing | Do Plant Sizing | Do Design Days | Do Weather Simulation | Do HVAC Sizing Simulation | |
| 1 | Yes | Yes | Yes | No | Yes | Yes |
| Use Coil Direct Simulation | Zone Radiant Exchange Algorithm | Override Mode | Number of Timestep In Hour | Force Euler Method | Minimum Number of Warmup Days | Force Suppress All Begin Environment Resets | Minimum System Timestep | MaxZoneTempDiff | MaxAllowedDelTemp | |
| 1 | No | ScriptF | Normal | 6 | No | 1 | No | 1.0 | 0.300 | 2.0000E-003 |
| Tolerance for Time Heating Setpoint Not Met | Tolerance for Zone Cooling Setpoint Not Met Time | |
| 1 | 0.200 | 0.200 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 | 18.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 24.20 | 18.90 | 15.70 | 13.60 | 15.50 | 17.10 | 21.20 | 26.90 | 27.60 | 27.90 | 27.40 | 26.20 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 | 13.00 |
| Jan{C} | Feb{C} | Mar{C} | Apr{C} | May{C} | Jun{C} | Jul{C} | Aug{C} | Sep{C} | Oct{C} | Nov{C} | Dec{C} | |
| 1 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 | 16.00 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Normal | Daylighting {dimensionless} | |
| 1 | 1.000 | 1.000 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Jan{dimensionless} | Feb{dimensionless} | Mar{dimensionless} | Apr{dimensionless} | May{dimensionless} | Jun{dimensionless} | Jul{dimensionless} | Aug{dimensionless} | Sep{dimensionless} | Oct{dimensionless} | Nov{dimensionless} | Dec{dimensionless} | |
| 1 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 |
| Wind Sensor Height Above Ground {m} | Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Sensor Height Above Ground {m} | Wind Speed Modifier Coefficient-Internal | Temperature Modifier Coefficient-Internal | |
| 1 | 10.000 | 0.140 | 270.000 | 1.500 | 1.586 | 9.750E-003 |
| Location Name | Latitude {N+/S- Deg} | Longitude {E+/W- Deg} | Time Zone Number {GMT+/-} | Elevation {m} | Standard Pressure at Elevation {Pa} | Standard RhoAir at Elevation | |
| 1 | SINGAPORE - SGP IWEC Data WMO#=486980 | 1.37 | 103.98 | 8.00 | 16.00 | 101133 | 1.2020 |
| Calculation Method{} | Water Mains Temperature Schedule Name{} | Annual Average Outdoor Air Temperature{C} | Maximum Difference In Monthly Average Outdoor Air Temperatures{deltaC} | Fixed Default Water Mains Temperature{C} | |
| 1 | Correlation | NA | 21.85 | 14.30 | NA |
| Building Name | North Axis {deg} | Terrain | Loads Convergence Tolerance Value | Temperature Convergence Tolerance Value | Solar Distribution | Maximum Number of Warmup Days | Minimum Number of Warmup Days | |
| 1 | -College-ASHRAE 169-2013-2A created: 2023-09-08 18:26:06 +0800 | 0.000 | City | 4.00000E-002 | 0.20000 | FullInteriorAndExterior | 25 | 6 |
| Algorithm {Simple TARP CeilingDiffuser AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Algorithm {SimpleCombined TARP MoWitt DOE-2 AdaptiveConvectionAlgorithm} |
|
| 1 | TARP |
| Value {Anisotropic} | |
| 1 | Anisotropic |
| Algorithm {ThirdOrderBackwardDifference AnalyticalSolution EulerMethod} |
Space Heat Balance Sizing |
Space Heat Balance Simulation |
|
| 1 | ThirdOrderBackwardDifference | No | No |
| Simulation {Yes/No} | Carbon Dioxide Concentration | |
| 1 | No | N/A |
| Simulation {Yes/No} | Generic Contaminant Concentration | |
| 1 | No | N/A |
| Enforce Mass Balance |
Adjust Zone Mixing and Return {AdjustMixingOnly AdjustReturnOnly AdjustMixingThenReturn AdjustReturnThenMixing None} |
Adjust Zone Infiltration {AddInfiltration AdjustInfiltration None} |
Infiltration Zones {MixingSourceZonesOnly AllZones} |
|
| 1 | No | N/A | N/A | N/A |
| Value {RegulaFalsi Bisection BisectionThenRegulaFalsi RegulaFalsiThenBisection} |
|
| 1 | RegulaFalsi |
| Wind Speed Profile Exponent {} | Wind Speed Profile Boundary Layer Thickness {m} | Air Temperature Gradient Coefficient {K/m} | |
| 1 | 0.330 | 460.000 | 6.500000E-003 |
| Starting Corner | Vertex Input Direction | Coordinate System | Daylight Reference Point Coordinate System | Rectangular (Simple) Surface Coordinate System | |
| 1 | UpperLeftCorner | Counterclockwise | RelativeCoordinateSystem | RelativeCoordinateSystem | RelativeToZoneOrigin |
| Value {CTF - ConductionTransferFunction EMPD - MoisturePenetrationDepthConductionTransferFunction CondFD - ConductionFiniteDifference HAMT - CombinedHeatAndMoistureFiniteElement} - Description |
Inside Surface Max Temperature Limit{C} |
Surface Convection Coefficient Lower Limit {W/m2-K} |
Surface Convection Coefficient Upper Limit {W/m2-K} |
|
| 1 | CTF - ConductionTransferFunction | 200 | 0.10 | 1000.0 |
| Number of Fixed Detached Shades | Number of Building Detached Shades | Number of Attached Shades | |
| 1 | 0 | 0 | 0 |
| Number of Zones | Number of Zone Surfaces | Number of SubSurfaces | |
| 1 | 117 | 1149 | 104 |
| Zone Name | North Axis {deg} | Origin X-Coordinate {m} | Origin Y-Coordinate {m} | Origin Z-Coordinate {m} | Centroid X-Coordinate {m} | Centroid Y-Coordinate {m} | Centroid Z-Coordinate {m} | Type | Zone Multiplier | Zone List Multiplier | Minimum X {m} | Maximum X {m} | Minimum Y {m} | Maximum Y {m} | Minimum Z {m} | Maximum Z {m} | Ceiling Height {m} | Volume {m3} | Zone Inside Convection Algorithm {Simple-Detailed-CeilingDiffuser-TrombeWall} | Zone Outside Convection Algorithm {Simple-Detailed-Tarp-MoWitt-DOE-2-BLAST} | Floor Area {m2} | Exterior Gross Wall Area {m2} | Exterior Net Wall Area {m2} | Exterior Window Area {m2} | Number of Surfaces | Number of SubSurfaces | Number of Shading SubSurfaces | Part of Total Building Area | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.0 | 0.00 | 37.80 | 0.00 | 8.99 | 34.95 | 1.98 | 1 | 1 | 1 | 0.00 | 18.29 | 29.57 | 40.08 | 0.00 | 3.96 | 3.96 | 712.31 | TARP | TARP | 179.77 | 105.07 | 72.78 | 32.29 | 13 | 2 | 0 | Yes |
| 2 | CB_CLASSROOM_1_F2 ZN | 0.0 | 63.40 | 29.57 | 3.96 | 59.97 | 33.68 | 5.94 | 1 | 1 | 1 | 56.54 | 63.40 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 59.78 | 41.49 | 18.29 | 7 | 2 | 0 | Yes |
| 3 | CB_CLASSROOM_1_F3 ZN | 0.0 | 56.54 | 37.80 | 7.92 | 59.97 | 33.68 | 9.91 | 1 | 1 | 1 | 56.54 | 63.40 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 59.78 | 41.40 | 18.39 | 7 | 2 | 0 | Yes |
| 4 | CB_CLASSROOM_1_F4 ZN | 0.0 | 5.49 | 37.80 | 11.89 | 4.57 | 33.68 | 13.87 | 1 | 1 | 1 | -9.77E-015 | 9.14 | 29.57 | 37.80 | 11.89 | 15.85 | 3.96 | 298.18 | TARP | TARP | 75.25 | 68.84 | 47.71 | 21.13 | 8 | 2 | 0 | Yes |
| 5 | CB_CLASSROOM_2_F2 ZN | 0.0 | 49.68 | 37.80 | 3.96 | 53.11 | 33.68 | 5.94 | 1 | 1 | 1 | 49.68 | 56.54 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.86 | 8.32 | 7 | 1 | 0 | Yes |
| 6 | CB_CLASSROOM_2_F3 ZN | 0.0 | 56.54 | 29.57 | 7.92 | 53.11 | 33.68 | 9.91 | 1 | 1 | 1 | 49.68 | 56.54 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.82 | 8.36 | 7 | 1 | 0 | Yes |
| 7 | CB_CLASSROOM_2_F4 ZN | 0.0 | 9.14 | 37.80 | 11.89 | 13.72 | 33.68 | 13.87 | 1 | 1 | 1 | 9.14 | 18.29 | 29.57 | 37.80 | 11.89 | 15.85 | 3.96 | 298.18 | TARP | TARP | 75.25 | 36.23 | 25.11 | 11.12 | 7 | 1 | 0 | Yes |
| 8 | CB_CLASSROOM_3_F2 ZN | 0.0 | 49.68 | 29.57 | 3.96 | 46.25 | 33.68 | 5.94 | 1 | 1 | 1 | 42.82 | 49.68 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.85 | 8.32 | 8 | 1 | 0 | Yes |
| 9 | CB_CLASSROOM_3_F3 ZN | 0.0 | 49.68 | 29.57 | 7.92 | 46.25 | 33.68 | 9.91 | 1 | 1 | 1 | 42.82 | 49.68 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.81 | 8.36 | 8 | 1 | 0 | Yes |
| 10 | CB_CLASSROOM_3_F4 ZN | 0.0 | 27.43 | 29.57 | 11.89 | 22.86 | 33.68 | 13.87 | 1 | 1 | 1 | 18.29 | 27.43 | 29.57 | 37.80 | 11.89 | 15.85 | 3.96 | 298.18 | TARP | TARP | 75.25 | 36.23 | 25.12 | 11.11 | 8 | 1 | 0 | Yes |
| 11 | CB_CLASSROOM_4_F2 ZN | 0.0 | 35.97 | 37.80 | 3.96 | 39.40 | 33.68 | 5.94 | 1 | 1 | 1 | 35.97 | 42.82 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.87 | 8.30 | 7 | 1 | 0 | Yes |
| 12 | CB_CLASSROOM_4_F3 ZN | 0.0 | 42.82 | 29.57 | 7.92 | 39.40 | 33.68 | 9.91 | 1 | 1 | 1 | 35.97 | 42.82 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.82 | 8.36 | 7 | 1 | 0 | Yes |
| 13 | CB_CLASSROOM_4_F4 ZN | 0.0 | 35.97 | 37.80 | 11.89 | 40.54 | 33.68 | 13.87 | 1 | 1 | 1 | 35.97 | 45.11 | 29.57 | 37.80 | 11.89 | 15.85 | 3.96 | 298.18 | TARP | TARP | 75.25 | 36.23 | 25.12 | 11.11 | 8 | 1 | 0 | Yes |
| 14 | CB_CLASSROOM_5_F2 ZN | 0.0 | 27.43 | 29.57 | 3.96 | 24.00 | 33.68 | 5.94 | 1 | 1 | 1 | 20.57 | 27.43 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.87 | 8.31 | 7 | 1 | 0 | Yes |
| 15 | CB_CLASSROOM_5_F3 ZN | 0.0 | 27.43 | 29.57 | 7.92 | 24.00 | 33.68 | 9.91 | 1 | 1 | 1 | 20.57 | 27.43 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.82 | 8.35 | 7 | 1 | 0 | Yes |
| 16 | CB_CLASSROOM_5_F4 ZN | 0.0 | 54.25 | 29.57 | 11.89 | 49.68 | 33.68 | 13.87 | 1 | 1 | 1 | 45.11 | 54.25 | 29.57 | 37.80 | 11.89 | 15.85 | 3.96 | 298.18 | TARP | TARP | 75.25 | 36.23 | 25.11 | 11.13 | 7 | 1 | 0 | Yes |
| 17 | CB_CLASSROOM_6_F2 ZN | 0.0 | 18.29 | 37.80 | 3.96 | 17.15 | 33.68 | 5.94 | 1 | 1 | 1 | 13.72 | 20.57 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.90 | 8.27 | 8 | 1 | 0 | Yes |
| 18 | CB_CLASSROOM_6_F3 ZN | 0.0 | 20.57 | 29.57 | 7.92 | 17.15 | 33.68 | 9.91 | 1 | 1 | 1 | 13.72 | 20.57 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.82 | 8.36 | 8 | 1 | 0 | Yes |
| 19 | CB_CLASSROOM_6_F4 ZN | 0.0 | 63.40 | 29.57 | 11.89 | 58.83 | 33.68 | 13.87 | 1 | 1 | 1 | 54.25 | 63.40 | 29.57 | 37.80 | 11.89 | 15.85 | 3.96 | 298.18 | TARP | TARP | 75.25 | 68.84 | 47.68 | 21.16 | 8 | 2 | 0 | Yes |
| 20 | CB_CLASSROOM_7_F2 ZN | 0.0 | 13.72 | 29.57 | 3.96 | 10.29 | 33.68 | 5.94 | 1 | 1 | 1 | 6.86 | 13.72 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.92 | 8.25 | 7 | 1 | 0 | Yes |
| 21 | CB_CLASSROOM_7_F3 ZN | 0.0 | 13.72 | 29.57 | 7.92 | 10.29 | 33.68 | 9.91 | 1 | 1 | 1 | 6.86 | 13.72 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 27.17 | 18.82 | 8.36 | 7 | 1 | 0 | Yes |
| 22 | CB_CLASSROOM_8_F2 ZN | 0.0 | 5.49 | 37.80 | 3.96 | 3.43 | 33.68 | 5.94 | 1 | 1 | 1 | 0.00 | 6.86 | 29.57 | 37.80 | 3.96 | 7.92 | 3.96 | 223.63 | TARP | TARP | 56.44 | 59.78 | 41.47 | 18.31 | 7 | 2 | 0 | Yes |
| 23 | CB_CLASSROOM_8_F3 ZN | 0.0 | 6.86 | 29.57 | 7.92 | 3.43 | 33.68 | 9.91 | 1 | 1 | 1 | 0.00 | 6.86 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 223.63 | TARP | TARP | 56.44 | 59.78 | 41.39 | 18.39 | 7 | 2 | 0 | Yes |
| 24 | CB_CONFERENCE_ROOM_F1 ZN | 0.0 | 21.34 | 45.11 | 0.00 | 22.86 | 42.60 | 1.98 | 1 | 1 | 1 | 18.29 | 27.43 | 40.08 | 45.11 | 0.00 | 3.96 | 3.96 | 182.22 | TARP | TARP | 45.99 | 0.00 | 0.00 | 0.00 | 8 | 0 | 0 | Yes |
| 25 | CB_CONFERENCE_ROOM_F2 ZN | 0.0 | 18.29 | 45.11 | 3.96 | 21.34 | 42.60 | 5.94 | 1 | 1 | 1 | 18.29 | 24.38 | 40.08 | 45.11 | 3.96 | 7.92 | 3.96 | 121.48 | TARP | TARP | 30.66 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 26 | CB_CONFERENCE_ROOM_F3 ZN | 0.0 | 24.38 | 40.08 | 7.92 | 21.34 | 42.60 | 9.91 | 1 | 1 | 1 | 18.29 | 24.38 | 40.08 | 45.11 | 7.92 | 11.89 | 3.96 | 121.48 | TARP | TARP | 30.66 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 27 | CB_CONFERENCE_ROOM_F4 ZN | 0.0 | 18.29 | 45.11 | 11.89 | 21.34 | 42.60 | 13.87 | 1 | 1 | 1 | 18.29 | 24.38 | 40.08 | 45.11 | 11.89 | 15.85 | 3.96 | 121.48 | TARP | TARP | 30.66 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 28 | CB_CORRIDOR_1_F3 ZN | 0.0 | 33.53 | 29.57 | 7.92 | 30.90 | 34.33 | 9.91 | 1 | 1 | 1 | 27.43 | 33.53 | 29.57 | 37.80 | 7.92 | 11.89 | 3.96 | 125.16 | TARP | TARP | 31.59 | 12.08 | 8.36 | 3.72 | 9 | 1 | 0 | Yes |
| 29 | CB_CORRIDOR_2_F3 ZN | 0.0 | 45.11 | 40.08 | 7.92 | 31.70 | 38.94 | 9.91 | 1 | 1 | 1 | 18.29 | 45.11 | 37.80 | 40.08 | 7.92 | 11.89 | 3.96 | 242.96 | TARP | TARP | 61.32 | 0.00 | 0.00 | 0.00 | 15 | 0 | 0 | Yes |
| 30 | CB_CORRIDOR_F1 ZN | 0.0 | 18.29 | 29.57 | 0.00 | 36.15 | 37.28 | 1.98 | 1 | 1 | 1 | 18.29 | 57.91 | 29.57 | 40.08 | -2.21E-029 | 3.96 | 3.96 | 638.69 | TARP | TARP | 122.17 | 12.08 | 8.39 | 3.69 | 21 | 1 | 0 | Yes |
| 31 | CB_CORRIDOR_F2 ZN | 0.0 | 41.30 | 40.08 | 3.96 | 31.47 | 37.13 | 5.94 | 1 | 1 | 1 | 18.29 | 45.11 | 29.57 | 40.08 | 3.96 | 7.92 | 3.96 | 368.12 | TARP | TARP | 92.90 | 12.08 | 8.39 | 3.69 | 21 | 1 | 0 | Yes |
| 32 | CB_CORRIDOR_F4 ZN | 0.0 | 35.97 | 37.80 | 11.89 | 31.56 | 37.85 | 13.87 | 1 | 1 | 1 | 5.49 | 57.91 | 29.57 | 40.08 | 11.89 | 15.85 | 3.96 | 600.03 | TARP | TARP | 151.43 | 12.08 | 8.39 | 3.69 | 31 | 1 | 0 | Yes |
| 33 | CB_ENTRANCE_LOBBY_F1 ZN | 0.0 | 18.29 | 29.57 | 0.00 | 22.86 | 33.68 | 1.98 | 1 | 1 | 1 | 18.29 | 27.43 | 29.57 | 37.80 | 0.00 | 3.96 | 3.96 | 298.18 | TARP | TARP | 75.25 | 36.23 | 25.09 | 11.14 | 8 | 1 | 0 | Yes |
| 34 | CB_FACULTY_OFFICE_1_F2 ZN | 0.0 | 45.11 | 51.21 | 3.96 | 43.43 | 53.04 | 5.94 | 1 | 1 | 1 | 41.76 | 45.11 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 35 | CB_FACULTY_OFFICE_1_F3 ZN | 0.0 | 41.76 | 54.86 | 7.92 | 43.43 | 53.04 | 9.91 | 1 | 1 | 1 | 41.76 | 45.11 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 36 | CB_FACULTY_OFFICE_1_F4 ZN | 0.0 | 45.11 | 51.21 | 11.89 | 43.43 | 53.04 | 13.87 | 1 | 1 | 1 | 41.76 | 45.11 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.22 | 4.07 | 6 | 1 | 0 | Yes |
| 37 | CB_FACULTY_OFFICE_2_F2 ZN | 0.0 | 38.40 | 54.86 | 3.96 | 40.08 | 53.04 | 5.94 | 1 | 1 | 1 | 38.40 | 41.76 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.21 | 4.07 | 6 | 1 | 0 | Yes |
| 38 | CB_FACULTY_OFFICE_2_F3 ZN | 0.0 | 38.40 | 54.86 | 7.92 | 40.08 | 53.04 | 9.91 | 1 | 1 | 1 | 38.40 | 41.76 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 39 | CB_FACULTY_OFFICE_2_F4 ZN | 0.0 | 38.40 | 54.86 | 11.89 | 40.08 | 53.04 | 13.87 | 1 | 1 | 1 | 38.40 | 41.76 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 40 | CB_FACULTY_OFFICE_3_F2 ZN | 0.0 | 38.40 | 51.21 | 3.96 | 36.73 | 53.04 | 5.94 | 1 | 1 | 1 | 35.05 | 38.40 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.23 | 4.06 | 6 | 1 | 0 | Yes |
| 41 | CB_FACULTY_OFFICE_3_F3 ZN | 0.0 | 35.05 | 54.86 | 7.92 | 36.73 | 53.04 | 9.91 | 1 | 1 | 1 | 35.05 | 38.40 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 42 | CB_FACULTY_OFFICE_3_F4 ZN | 0.0 | 38.40 | 51.21 | 11.89 | 36.73 | 53.04 | 13.87 | 1 | 1 | 1 | 35.05 | 38.40 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 43 | CB_FACULTY_OFFICE_4_F2 ZN | 0.0 | 31.70 | 54.86 | 3.96 | 33.38 | 53.04 | 5.94 | 1 | 1 | 1 | 31.70 | 35.05 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.23 | 4.05 | 6 | 1 | 0 | Yes |
| 44 | CB_FACULTY_OFFICE_4_F3 ZN | 0.0 | 31.70 | 54.86 | 7.92 | 33.38 | 53.04 | 9.91 | 1 | 1 | 1 | 31.70 | 35.05 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 45 | CB_FACULTY_OFFICE_4_F4 ZN | 0.0 | 31.70 | 54.86 | 11.89 | 33.38 | 53.04 | 13.87 | 1 | 1 | 1 | 31.70 | 35.05 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 46 | CB_FACULTY_OFFICE_5_F2 ZN | 0.0 | 31.70 | 51.21 | 3.96 | 30.02 | 53.04 | 5.94 | 1 | 1 | 1 | 28.35 | 31.70 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.24 | 4.05 | 6 | 1 | 0 | Yes |
| 47 | CB_FACULTY_OFFICE_5_F3 ZN | 0.0 | 28.35 | 54.86 | 7.92 | 30.02 | 53.04 | 9.91 | 1 | 1 | 1 | 28.35 | 31.70 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 48 | CB_FACULTY_OFFICE_5_F4 ZN | 0.0 | 31.70 | 51.21 | 11.89 | 30.02 | 53.04 | 13.87 | 1 | 1 | 1 | 28.35 | 31.70 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 49 | CB_FACULTY_OFFICE_6_F2 ZN | 0.0 | 24.99 | 54.86 | 3.96 | 26.67 | 53.04 | 5.94 | 1 | 1 | 1 | 24.99 | 28.35 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.22 | 4.06 | 6 | 1 | 0 | Yes |
| 50 | CB_FACULTY_OFFICE_6_F3 ZN | 0.0 | 24.99 | 54.86 | 7.92 | 26.67 | 53.04 | 9.91 | 1 | 1 | 1 | 24.99 | 28.35 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 51 | CB_FACULTY_OFFICE_6_F4 ZN | 0.0 | 24.99 | 54.86 | 11.89 | 26.67 | 53.04 | 13.87 | 1 | 1 | 1 | 24.99 | 28.35 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 52 | CB_FACULTY_OFFICE_7_F2 ZN | 0.0 | 24.99 | 51.21 | 3.96 | 23.32 | 53.04 | 5.94 | 1 | 1 | 1 | 21.64 | 24.99 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.23 | 4.06 | 6 | 1 | 0 | Yes |
| 53 | CB_FACULTY_OFFICE_7_F3 ZN | 0.0 | 21.64 | 54.86 | 7.92 | 23.32 | 53.04 | 9.91 | 1 | 1 | 1 | 21.64 | 24.99 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 54 | CB_FACULTY_OFFICE_7_F4 ZN | 0.0 | 24.99 | 51.21 | 11.89 | 23.32 | 53.04 | 13.87 | 1 | 1 | 1 | 21.64 | 24.99 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 55 | CB_FACULTY_OFFICE_8_F2 ZN | 0.0 | 18.29 | 54.86 | 3.96 | 19.96 | 53.04 | 5.94 | 1 | 1 | 1 | 18.29 | 21.64 | 51.21 | 54.86 | 3.96 | 7.92 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.22 | 4.06 | 7 | 1 | 0 | Yes |
| 56 | CB_FACULTY_OFFICE_8_F3 ZN | 0.0 | 21.64 | 51.21 | 7.92 | 19.96 | 53.04 | 9.91 | 1 | 1 | 1 | 18.29 | 21.64 | 51.21 | 54.86 | 7.92 | 11.89 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 57 | CB_FACULTY_OFFICE_8_F4 ZN | 0.0 | 18.29 | 54.86 | 11.89 | 19.96 | 53.04 | 13.87 | 1 | 1 | 1 | 18.29 | 21.64 | 51.21 | 54.86 | 11.89 | 15.85 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.09 | 6 | 1 | 0 | Yes |
| 58 | CB_FACULTY_RESTROOMS_1_F2 ZN | 0.0 | 33.53 | 40.08 | 3.96 | 35.51 | 41.34 | 5.94 | 1 | 1 | 1 | 33.53 | 37.49 | 40.08 | 42.60 | 3.96 | 7.92 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 59 | CB_FACULTY_RESTROOMS_1_F3 ZN | 0.0 | 37.49 | 42.60 | 7.92 | 35.51 | 41.34 | 9.91 | 1 | 1 | 1 | 33.53 | 37.49 | 40.08 | 42.60 | 7.92 | 11.89 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 60 | CB_FACULTY_RESTROOMS_1_F4 ZN | 0.0 | 37.49 | 45.11 | 11.89 | 35.51 | 43.85 | 13.87 | 1 | 1 | 1 | 33.53 | 37.49 | 42.60 | 45.11 | 11.89 | 15.85 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 61 | CB_FACULTY_RESTROOMS_2_F2 ZN | 0.0 | 37.49 | 45.11 | 3.96 | 35.51 | 43.85 | 5.94 | 1 | 1 | 1 | 33.53 | 37.49 | 42.60 | 45.11 | 3.96 | 7.92 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 62 | CB_FACULTY_RESTROOMS_2_F3 ZN | 0.0 | 33.53 | 42.60 | 7.92 | 35.51 | 43.85 | 9.91 | 1 | 1 | 1 | 33.53 | 37.49 | 42.60 | 45.11 | 7.92 | 11.89 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 63 | CB_FACULTY_RESTROOMS_2_F4 ZN | 0.0 | 33.53 | 40.08 | 11.89 | 35.51 | 41.34 | 13.87 | 1 | 1 | 1 | 33.53 | 37.49 | 40.08 | 42.60 | 11.89 | 15.85 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 64 | CB_LAB_1_F4 ZN | 0.0 | 0.00 | 54.86 | 11.89 | 4.57 | 47.47 | 13.87 | 1 | 1 | 1 | 0.00 | 9.14 | 40.08 | 54.86 | 11.89 | 15.85 | 3.96 | 535.61 | TARP | TARP | 135.17 | 94.81 | 65.73 | 29.08 | 7 | 2 | 0 | Yes |
| 65 | CB_LAB_2_F4 ZN | 0.0 | 9.14 | 54.86 | 11.89 | 13.72 | 47.47 | 13.87 | 1 | 1 | 1 | 9.14 | 18.29 | 40.08 | 54.86 | 11.89 | 15.85 | 3.96 | 535.61 | TARP | TARP | 135.17 | 36.23 | 25.11 | 11.12 | 8 | 1 | 0 | Yes |
| 66 | CB_LAB_3_F4 ZN | 0.0 | 54.25 | 54.86 | 11.89 | 49.68 | 47.47 | 13.87 | 1 | 1 | 1 | 45.11 | 54.25 | 40.08 | 54.86 | 11.89 | 15.85 | 3.96 | 535.61 | TARP | TARP | 135.17 | 36.23 | 25.11 | 11.12 | 8 | 1 | 0 | Yes |
| 67 | CB_LAB_4_F4 ZN | 0.0 | 63.40 | 40.08 | 11.89 | 58.83 | 47.47 | 13.87 | 1 | 1 | 1 | 54.25 | 63.40 | 40.08 | 54.86 | 11.89 | 15.85 | 3.96 | 535.61 | TARP | TARP | 135.17 | 94.81 | 65.71 | 29.10 | 7 | 2 | 0 | Yes |
| 68 | CB_LECTURE_ROOM_1_F1 ZN | 0.0 | 63.40 | 54.86 | 0.00 | 54.25 | 47.47 | 1.98 | 1 | 1 | 1 | 45.11 | 63.40 | 40.08 | 54.86 | 0.00 | 3.96 | 3.96 | 1071.23 | TARP | TARP | 270.35 | 131.04 | 90.73 | 40.31 | 10 | 2 | 0 | Yes |
| 69 | CB_LECTURE_ROOM_2_F1 ZN | 0.0 | 45.11 | 29.57 | 0.00 | 54.25 | 33.68 | 1.98 | 1 | 1 | 1 | 45.11 | 63.40 | 29.57 | 37.80 | 0.00 | 3.96 | 3.96 | 596.35 | TARP | TARP | 150.50 | 105.07 | 72.75 | 32.32 | 10 | 2 | 0 | Yes |
| 70 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.0 | 18.29 | 45.11 | 0.00 | 9.14 | 47.47 | 1.98 | 1 | 1 | 1 | 0.00 | 18.29 | 40.08 | 54.86 | 0.00 | 3.96 | 3.96 | 1071.23 | TARP | TARP | 270.35 | 131.04 | 90.80 | 40.24 | 10 | 2 | 0 | Yes |
| 71 | CB_MAIN_STAIRS_F1 ZN | 0.0 | 27.43 | 29.57 | 0.00 | 28.96 | 32.61 | 1.98 | 1 | 1 | 1 | 27.43 | 30.48 | 29.57 | 35.66 | 0.00 | 3.96 | 3.96 | 73.62 | TARP | TARP | 18.58 | 12.08 | 8.39 | 3.69 | 6 | 1 | 0 | Yes |
| 72 | CB_MAIN_STAIRS_F2 ZN | 0.0 | 27.43 | 29.57 | 3.96 | 28.96 | 32.61 | 5.94 | 1 | 1 | 1 | 27.43 | 30.48 | 29.57 | 35.66 | 3.96 | 7.92 | 3.96 | 73.62 | TARP | TARP | 18.58 | 12.08 | 8.42 | 3.66 | 6 | 1 | 0 | Yes |
| 73 | CB_MAIN_STAIRS_F3 ZN | 0.0 | 30.48 | 29.57 | 7.92 | 28.96 | 32.61 | 9.91 | 1 | 1 | 1 | 27.43 | 30.48 | 29.57 | 35.66 | 7.92 | 11.89 | 3.96 | 73.62 | TARP | TARP | 18.58 | 12.08 | 8.37 | 3.71 | 6 | 1 | 0 | Yes |
| 74 | CB_MAIN_STAIRS_F4 ZN | 0.0 | 27.43 | 29.57 | 11.89 | 28.96 | 32.61 | 13.87 | 1 | 1 | 1 | 27.43 | 30.48 | 29.57 | 35.66 | 11.89 | 15.85 | 3.96 | 73.62 | TARP | TARP | 18.58 | 12.08 | 8.42 | 3.66 | 6 | 1 | 0 | Yes |
| 75 | CB_OFFICES_ENCLOSED_1_F1 ZN | 0.0 | 45.11 | 51.21 | 0.00 | 43.43 | 53.04 | 1.98 | 1 | 1 | 1 | 41.76 | 45.11 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 76 | CB_OFFICES_ENCLOSED_2_F1 ZN | 0.0 | 38.40 | 54.86 | 0.00 | 40.08 | 53.04 | 1.98 | 1 | 1 | 1 | 38.40 | 41.76 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 77 | CB_OFFICES_ENCLOSED_3_F1 ZN | 0.0 | 38.40 | 51.21 | 0.00 | 36.73 | 53.04 | 1.98 | 1 | 1 | 1 | 35.05 | 38.40 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 78 | CB_OFFICES_ENCLOSED_4_F1 ZN | 0.0 | 31.70 | 54.86 | 0.00 | 33.38 | 53.04 | 1.98 | 1 | 1 | 1 | 31.70 | 35.05 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 79 | CB_OFFICES_ENCLOSED_5_F1 ZN | 0.0 | 31.70 | 51.21 | 0.00 | 30.02 | 53.04 | 1.98 | 1 | 1 | 1 | 28.35 | 31.70 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 80 | CB_OFFICES_ENCLOSED_6_F1 ZN | 0.0 | 24.99 | 54.86 | 0.00 | 26.67 | 53.04 | 1.98 | 1 | 1 | 1 | 24.99 | 28.35 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 81 | CB_OFFICES_ENCLOSED_7_F1 ZN | 0.0 | 24.99 | 51.21 | 0.00 | 23.32 | 53.04 | 1.98 | 1 | 1 | 1 | 21.64 | 24.99 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.20 | 4.08 | 6 | 1 | 0 | Yes |
| 82 | CB_OFFICES_ENCLOSED_8_F1 ZN | 0.0 | 18.29 | 54.86 | 0.00 | 19.96 | 53.04 | 1.98 | 1 | 1 | 1 | 18.29 | 21.64 | 51.21 | 54.86 | 0.00 | 3.96 | 3.96 | 48.59 | TARP | TARP | 12.26 | 13.29 | 9.21 | 4.07 | 6 | 1 | 0 | Yes |
| 83 | CB_OFFICES_OPEN_F1 ZN | 0.0 | 18.29 | 45.11 | 0.00 | 31.29 | 46.09 | 1.98 | 1 | 1 | 1 | 18.29 | 45.11 | 40.08 | 51.21 | 0.00 | 3.96 | 3.96 | 769.37 | TARP | TARP | 194.17 | 0.00 | 0.00 | 0.00 | 22 | 0 | 0 | Yes |
| 84 | CB_OFFICES_OPEN_F2 ZN | 0.0 | 37.49 | 45.11 | 3.96 | 30.86 | 45.92 | 5.94 | 1 | 1 | 1 | 18.29 | 45.11 | 40.08 | 51.21 | 3.96 | 7.92 | 3.96 | 830.11 | TARP | TARP | 209.50 | 0.00 | 0.00 | 0.00 | 21 | 0 | 0 | Yes |
| 85 | CB_OFFICES_OPEN_F3 ZN | 0.0 | 18.29 | 45.11 | 7.92 | 30.75 | 45.98 | 9.91 | 1 | 1 | 1 | 18.29 | 45.11 | 40.08 | 51.21 | 7.92 | 11.89 | 3.96 | 830.11 | TARP | TARP | 209.50 | 0.00 | 0.00 | 0.00 | 20 | 0 | 0 | Yes |
| 86 | CB_OFFICES_OPEN_F4 ZN | 0.0 | 18.29 | 45.11 | 11.89 | 30.75 | 45.98 | 13.87 | 1 | 1 | 1 | 18.29 | 45.11 | 40.08 | 51.21 | 11.89 | 15.85 | 3.96 | 830.11 | TARP | TARP | 209.50 | 0.00 | 0.00 | 0.00 | 20 | 0 | 0 | Yes |
| 87 | CB_PUBLIC_ELEVATORS_F1 ZN | 0.0 | 33.53 | 29.57 | 0.00 | 34.75 | 32.00 | 1.98 | 1 | 1 | 1 | 33.53 | 35.97 | 29.57 | 34.44 | 0.00 | 3.96 | 3.96 | 47.12 | TARP | TARP | 11.89 | 9.66 | 6.72 | 2.94 | 6 | 1 | 0 | Yes |
| 88 | CB_PUBLIC_ELEVATORS_F2 ZN | 0.0 | 33.53 | 29.57 | 3.96 | 34.75 | 32.00 | 5.94 | 1 | 1 | 1 | 33.53 | 35.97 | 29.57 | 34.44 | 3.96 | 7.92 | 3.96 | 47.12 | TARP | TARP | 11.89 | 9.66 | 6.72 | 2.94 | 6 | 1 | 0 | Yes |
| 89 | CB_PUBLIC_ELEVATORS_F3 ZN | 0.0 | 33.94 | 34.44 | 7.92 | 34.75 | 32.00 | 9.91 | 1 | 1 | 1 | 33.53 | 35.97 | 29.57 | 34.44 | 7.92 | 11.89 | 3.96 | 47.12 | TARP | TARP | 11.89 | 9.66 | 6.70 | 2.97 | 6 | 1 | 0 | Yes |
| 90 | CB_PUBLIC_ELEVATORS_F4 ZN | 0.0 | 33.53 | 29.57 | 11.89 | 34.75 | 32.00 | 13.87 | 1 | 1 | 1 | 33.53 | 35.97 | 29.57 | 34.44 | 11.89 | 15.85 | 3.96 | 47.12 | TARP | TARP | 11.89 | 9.66 | 6.72 | 2.94 | 6 | 1 | 0 | Yes |
| 91 | CB_SECONDARY_STAIRS_1_F1 ZN | 0.0 | 0.00 | 40.08 | 0.00 | 2.74 | 38.94 | 1.98 | 1 | 1 | 1 | 0.00 | 5.49 | 37.80 | 40.08 | 0.00 | 3.96 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.33 | 2.73 | 6 | 1 | 0 | Yes |
| 92 | CB_SECONDARY_STAIRS_1_F2 ZN | 0.0 | 5.78E-015 | 40.08 | 3.96 | 2.74 | 38.94 | 5.94 | 1 | 1 | 1 | 5.78E-015 | 5.49 | 37.80 | 40.08 | 3.96 | 7.92 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.33 | 2.72 | 6 | 1 | 0 | Yes |
| 93 | CB_SECONDARY_STAIRS_1_F3 ZN | 0.0 | 5.49 | 37.80 | 7.92 | 2.74 | 38.94 | 9.91 | 1 | 1 | 1 | 0.00 | 5.49 | 37.80 | 40.08 | 7.92 | 11.89 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.27 | 2.78 | 6 | 1 | 0 | Yes |
| 94 | CB_SECONDARY_STAIRS_1_F4 ZN | 0.0 | 0.00 | 40.08 | 11.89 | 2.74 | 38.94 | 13.87 | 1 | 1 | 1 | 0.00 | 5.49 | 37.80 | 40.08 | 11.89 | 15.85 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.33 | 2.73 | 6 | 1 | 0 | Yes |
| 95 | CB_SECONDARY_STAIRS_2_F1 ZN | 0.0 | 63.40 | 37.80 | 0.00 | 60.66 | 38.94 | 1.98 | 1 | 1 | 1 | 57.91 | 63.40 | 37.80 | 40.08 | 0.00 | 3.96 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.27 | 2.78 | 6 | 1 | 0 | Yes |
| 96 | CB_SECONDARY_STAIRS_2_F2 ZN | 0.0 | 63.40 | 37.80 | 3.96 | 60.66 | 38.94 | 5.94 | 1 | 1 | 1 | 57.91 | 63.40 | 37.80 | 40.08 | 3.96 | 7.92 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.30 | 2.75 | 6 | 1 | 0 | Yes |
| 97 | CB_SECONDARY_STAIRS_2_F3 ZN | 0.0 | 63.40 | 40.08 | 7.92 | 60.66 | 38.94 | 9.91 | 1 | 1 | 1 | 57.91 | 63.40 | 37.80 | 40.08 | 7.92 | 11.89 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.27 | 2.79 | 6 | 1 | 0 | Yes |
| 98 | CB_SECONDARY_STAIRS_2_F4 ZN | 0.0 | 63.40 | 37.80 | 11.89 | 60.66 | 38.94 | 13.87 | 1 | 1 | 1 | 57.91 | 63.40 | 37.80 | 40.08 | 11.89 | 15.85 | 3.96 | 49.70 | TARP | TARP | 12.54 | 9.06 | 6.28 | 2.78 | 6 | 1 | 0 | Yes |
| 99 | CB_STAFF_RESTROOMS_1_F1 ZN | 0.0 | 37.49 | 45.11 | 0.00 | 35.51 | 43.85 | 1.98 | 1 | 1 | 1 | 33.53 | 37.49 | 42.60 | 45.11 | 0.00 | 3.96 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 7 | 0 | 0 | Yes |
| 100 | CB_STAFF_RESTROOMS_2_F1 ZN | 0.0 | 33.53 | 40.08 | 0.00 | 35.51 | 41.34 | 1.98 | 1 | 1 | 1 | 33.53 | 37.49 | 40.08 | 42.60 | 0.00 | 3.96 | 3.96 | 39.48 | TARP | TARP | 9.96 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 101 | CB_STORAGE_F1 ZN | 0.0 | 45.11 | 29.57 | 0.00 | 40.54 | 33.68 | 1.98 | 1 | 1 | 1 | 35.97 | 45.11 | 29.57 | 37.80 | 0.00 | 3.96 | 3.96 | 298.18 | TARP | TARP | 75.25 | 36.23 | 25.10 | 11.13 | 8 | 1 | 0 | Yes |
| 102 | CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.0 | 37.49 | 45.11 | 0.00 | 39.40 | 42.60 | 1.98 | 1 | 1 | 1 | 37.49 | 41.30 | 40.08 | 45.11 | 0.00 | 3.96 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 7 | 0 | 0 | Yes |
| 103 | CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.0 | 37.49 | 45.11 | 3.96 | 39.40 | 42.60 | 5.94 | 1 | 1 | 1 | 37.49 | 41.30 | 40.08 | 45.11 | 3.96 | 7.92 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 7 | 0 | 0 | Yes |
| 104 | CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.0 | 41.30 | 40.08 | 7.92 | 39.40 | 42.60 | 9.91 | 1 | 1 | 1 | 37.49 | 41.30 | 40.08 | 45.11 | 7.92 | 11.89 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 7 | 0 | 0 | Yes |
| 105 | CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.0 | 37.49 | 45.11 | 11.89 | 39.40 | 42.60 | 13.87 | 1 | 1 | 1 | 37.49 | 41.30 | 40.08 | 45.11 | 11.89 | 15.85 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 7 | 0 | 0 | Yes |
| 106 | CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.0 | 45.11 | 40.08 | 0.00 | 43.21 | 42.60 | 1.98 | 1 | 1 | 1 | 41.30 | 45.11 | 40.08 | 45.11 | 0.00 | 3.96 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 107 | CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.0 | 45.11 | 40.08 | 3.96 | 43.21 | 42.60 | 5.94 | 1 | 1 | 1 | 41.30 | 45.11 | 40.08 | 45.11 | 3.96 | 7.92 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 108 | CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.0 | 41.30 | 45.11 | 7.92 | 43.21 | 42.60 | 9.91 | 1 | 1 | 1 | 41.30 | 45.11 | 40.08 | 45.11 | 7.92 | 11.89 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 109 | CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.0 | 45.11 | 40.08 | 11.89 | 43.21 | 42.60 | 13.87 | 1 | 1 | 1 | 41.30 | 45.11 | 40.08 | 45.11 | 11.89 | 15.85 | 3.96 | 75.92 | TARP | TARP | 19.16 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 110 | CB_STUDIO_1_F2 ZN | 0.0 | 5.49 | 37.80 | 3.96 | 8.88 | 45.78 | 5.94 | 1 | 1 | 1 | 0.00 | 18.29 | 37.80 | 54.86 | 3.96 | 7.92 | 3.96 | 1187.18 | TARP | TARP | 299.61 | 131.04 | 90.83 | 40.20 | 16 | 2 | 0 | Yes |
| 111 | CB_STUDIO_1_F3 ZN | 0.0 | 45.11 | 54.86 | 7.92 | 54.52 | 45.78 | 9.91 | 1 | 1 | 1 | 45.11 | 63.40 | 37.80 | 54.86 | 7.92 | 11.89 | 3.96 | 1187.18 | TARP | TARP | 299.61 | 131.04 | 90.73 | 40.31 | 15 | 2 | 0 | Yes |
| 112 | CB_STUDIO_2_F2 ZN | 0.0 | 45.11 | 37.80 | 3.96 | 54.52 | 45.78 | 5.94 | 1 | 1 | 1 | 45.11 | 63.40 | 37.80 | 54.86 | 3.96 | 7.92 | 3.96 | 1187.18 | TARP | TARP | 299.61 | 131.04 | 90.78 | 40.26 | 15 | 2 | 0 | Yes |
| 113 | CB_STUDIO_2_F3 ZN | 0.0 | 18.29 | 40.08 | 7.92 | 8.88 | 45.78 | 9.91 | 1 | 1 | 1 | 0.00 | 18.29 | 37.80 | 54.86 | 7.92 | 11.89 | 3.96 | 1187.18 | TARP | TARP | 299.61 | 131.04 | 90.75 | 40.29 | 15 | 2 | 0 | Yes |
| 114 | CB_UTILITY_F1 ZN | 0.0 | 35.97 | 37.80 | 0.00 | 34.75 | 36.12 | 1.98 | 1 | 1 | 1 | 33.53 | 35.97 | 34.44 | 37.80 | 0.00 | 3.96 | 3.96 | 32.39 | TARP | TARP | 8.18 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 115 | CB_UTILITY_F2 ZN | 0.0 | 35.97 | 37.80 | 3.96 | 34.75 | 36.12 | 5.94 | 1 | 1 | 1 | 33.53 | 35.97 | 34.44 | 37.80 | 3.96 | 7.92 | 3.96 | 32.39 | TARP | TARP | 8.18 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 116 | CB_UTILITY_F3 ZN | 0.0 | 35.97 | 37.80 | 7.92 | 34.75 | 36.12 | 9.91 | 1 | 1 | 1 | 33.53 | 35.97 | 34.44 | 37.80 | 7.92 | 11.89 | 3.96 | 32.39 | TARP | TARP | 8.18 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| 117 | CB_UTILITY_F4 ZN | 0.0 | 35.97 | 37.80 | 11.89 | 34.75 | 36.12 | 13.87 | 1 | 1 | 1 | 33.53 | 35.97 | 34.44 | 37.80 | 11.89 | 15.85 | 3.96 | 32.39 | TARP | TARP | 8.18 | 0.00 | 0.00 | 0.00 | 6 | 0 | 0 | Yes |
| Zone Name | Floor Area {m2} | # Occupants | Area per Occupant {m2/person} | Occupant per Area {person/m2} | Interior Lighting {W/m2} | Electric Load {W/m2} | Gas Load {W/m2} | Other Load {W/m2} | Hot Water Eq {W/m2} | Steam Equipment {W/m2} | Sum Loads per Area {W/m2} | Outdoor Controlled Baseboard Heat | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | 48.4 | 3.716 | 0.269 | 6.351 | 76.962 | 0.000 | 0.000 | 0.000 | 0.000 | 83.313 | No |
| 2 | CB_CLASSROOM_1_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 3 | CB_CLASSROOM_1_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 4 | CB_CLASSROOM_1_F4 ZN | 75.25 | 52.7 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 5 | CB_CLASSROOM_2_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 6 | CB_CLASSROOM_2_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 7 | CB_CLASSROOM_2_F4 ZN | 75.25 | 52.7 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 8 | CB_CLASSROOM_3_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 9 | CB_CLASSROOM_3_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 10 | CB_CLASSROOM_3_F4 ZN | 75.25 | 52.7 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 11 | CB_CLASSROOM_4_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 12 | CB_CLASSROOM_4_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 13 | CB_CLASSROOM_4_F4 ZN | 75.25 | 52.6 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 14 | CB_CLASSROOM_5_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 15 | CB_CLASSROOM_5_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 16 | CB_CLASSROOM_5_F4 ZN | 75.25 | 52.7 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 17 | CB_CLASSROOM_6_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 18 | CB_CLASSROOM_6_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 19 | CB_CLASSROOM_6_F4 ZN | 75.25 | 52.7 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 20 | CB_CLASSROOM_7_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 21 | CB_CLASSROOM_7_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 22 | CB_CLASSROOM_8_F2 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 23 | CB_CLASSROOM_8_F3 ZN | 56.44 | 39.5 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 24 | CB_CONFERENCE_ROOM_F1 ZN | 45.99 | 24.8 | 1.858 | 0.538 | 10.441 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 21.205 | No |
| 25 | CB_CONFERENCE_ROOM_F2 ZN | 30.66 | 16.5 | 1.858 | 0.538 | 10.441 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 21.205 | No |
| 26 | CB_CONFERENCE_ROOM_F3 ZN | 30.66 | 16.5 | 1.858 | 0.538 | 10.441 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 21.205 | No |
| 27 | CB_CONFERENCE_ROOM_F4 ZN | 30.66 | 16.5 | 1.858 | 0.538 | 10.441 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 21.205 | No |
| 28 | CB_CORRIDOR_1_F3 ZN | 31.59 | 0.0 | N/A | 0.000 | 4.413 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.396 | No |
| 29 | CB_CORRIDOR_2_F3 ZN | 61.32 | 0.0 | N/A | 0.000 | 4.413 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.396 | No |
| 30 | CB_CORRIDOR_F1 ZN | 122.17 | 0.0 | N/A | 0.000 | 4.413 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.396 | No |
| 31 | CB_CORRIDOR_F2 ZN | 92.90 | 0.0 | N/A | 0.000 | 4.413 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.396 | No |
| 32 | CB_CORRIDOR_F4 ZN | 151.43 | 0.0 | N/A | 0.000 | 4.413 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.396 | No |
| 33 | CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | 8.1 | 9.290 | 0.108 | 0.000 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 3.983 | No |
| 34 | CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 35 | CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 36 | CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 37 | CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 38 | CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 39 | CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 40 | CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 41 | CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 42 | CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 43 | CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 44 | CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 45 | CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 46 | CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 47 | CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 48 | CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 49 | CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 50 | CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 51 | CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 52 | CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 53 | CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 54 | CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 55 | CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 56 | CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 57 | CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 58 | CB_FACULTY_RESTROOMS_1_F2 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 59 | CB_FACULTY_RESTROOMS_1_F3 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 60 | CB_FACULTY_RESTROOMS_1_F4 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 61 | CB_FACULTY_RESTROOMS_2_F2 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 62 | CB_FACULTY_RESTROOMS_2_F3 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 63 | CB_FACULTY_RESTROOMS_2_F4 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 64 | CB_LAB_1_F4 ZN | 135.17 | 36.4 | 3.716 | 0.269 | 14.316 | 43.056 | 0.000 | 0.000 | 0.000 | 0.000 | 57.372 | No |
| 65 | CB_LAB_2_F4 ZN | 135.17 | 36.4 | 3.716 | 0.269 | 14.316 | 43.056 | 0.000 | 0.000 | 0.000 | 0.000 | 57.372 | No |
| 66 | CB_LAB_3_F4 ZN | 135.17 | 36.4 | 3.716 | 0.269 | 14.316 | 43.056 | 0.000 | 0.000 | 0.000 | 0.000 | 57.372 | No |
| 67 | CB_LAB_4_F4 ZN | 135.17 | 36.4 | 3.716 | 0.269 | 14.316 | 43.056 | 0.000 | 0.000 | 0.000 | 0.000 | 57.372 | No |
| 68 | CB_LECTURE_ROOM_1_F1 ZN | 270.35 | 189.2 | 1.429 | 0.700 | 6.566 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 16.566 | No |
| 69 | CB_LECTURE_ROOM_2_F1 ZN | 150.50 | 105.3 | 1.429 | 0.700 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 70 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | 29.1 | 9.290 | 0.108 | 8.934 | 10.010 | 0.000 | 0.000 | 0.000 | 0.000 | 18.944 | No |
| 71 | CB_MAIN_STAIRS_F1 ZN | 18.58 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 72 | CB_MAIN_STAIRS_F2 ZN | 18.58 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 73 | CB_MAIN_STAIRS_F3 ZN | 18.58 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 74 | CB_MAIN_STAIRS_F4 ZN | 18.58 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 75 | CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 76 | CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 77 | CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 78 | CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 79 | CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 80 | CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 81 | CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 82 | CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | 0.7 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 83 | CB_OFFICES_OPEN_F1 ZN | 194.17 | 10.5 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 84 | CB_OFFICES_OPEN_F2 ZN | 209.50 | 11.3 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 85 | CB_OFFICES_OPEN_F3 ZN | 209.50 | 11.3 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 86 | CB_OFFICES_OPEN_F4 ZN | 209.50 | 11.3 | 18.581 | 5.382E-002 | 7.965 | 10.764 | 0.000 | 0.000 | 0.000 | 0.000 | 18.729 | No |
| 87 | CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | 0.0 | N/A | 0.000 | 0.000 | 2710.875 | 0.000 | 0.000 | 0.000 | 0.000 | 2710.875 | No |
| 88 | CB_PUBLIC_ELEVATORS_F2 ZN | 11.89 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
| 89 | CB_PUBLIC_ELEVATORS_F3 ZN | 11.89 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
| 90 | CB_PUBLIC_ELEVATORS_F4 ZN | 11.89 | 0.0 | N/A | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | No |
| 91 | CB_SECONDARY_STAIRS_1_F1 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 92 | CB_SECONDARY_STAIRS_1_F2 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 93 | CB_SECONDARY_STAIRS_1_F3 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 94 | CB_SECONDARY_STAIRS_1_F4 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 95 | CB_SECONDARY_STAIRS_2_F1 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 96 | CB_SECONDARY_STAIRS_2_F2 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 97 | CB_SECONDARY_STAIRS_2_F3 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 98 | CB_SECONDARY_STAIRS_2_F4 ZN | 12.54 | 0.0 | N/A | 0.000 | 5.274 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 5.274 | No |
| 99 | CB_STAFF_RESTROOMS_1_F1 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 100 | CB_STAFF_RESTROOMS_2_F1 ZN | 9.96 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 101 | CB_STORAGE_F1 ZN | 75.25 | 0.0 | N/A | 0.000 | 4.090 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 4.090 | No |
| 102 | CB_STUDENTS_RESTROOMS_1_F1 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 103 | CB_STUDENTS_RESTROOMS_1_F2 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 104 | CB_STUDENTS_RESTROOMS_1_F3 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 105 | CB_STUDENTS_RESTROOMS_1_F4 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 106 | CB_STUDENTS_RESTROOMS_2_F1 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 107 | CB_STUDENTS_RESTROOMS_2_F2 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 108 | CB_STUDENTS_RESTROOMS_2_F3 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 109 | CB_STUDENTS_RESTROOMS_2_F4 ZN | 19.16 | 0.0 | N/A | 0.000 | 6.781 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 10.764 | No |
| 110 | CB_STUDIO_1_F2 ZN | 299.61 | 64.5 | 4.645 | 0.215 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 111 | CB_STUDIO_1_F3 ZN | 299.61 | 64.5 | 4.645 | 0.215 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 112 | CB_STUDIO_2_F2 ZN | 299.61 | 64.5 | 4.645 | 0.215 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 113 | CB_STUDIO_2_F3 ZN | 299.61 | 64.5 | 4.645 | 0.215 | 7.642 | 10.000 | 0.000 | 0.000 | 0.000 | 0.000 | 17.642 | No |
| 114 | CB_UTILITY_F1 ZN | 8.18 | 0.0 | N/A | 0.000 | 4.628 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.611 | No |
| 115 | CB_UTILITY_F2 ZN | 8.18 | 0.0 | N/A | 0.000 | 4.628 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.611 | No |
| 116 | CB_UTILITY_F3 ZN | 8.18 | 0.0 | N/A | 0.000 | 4.628 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.611 | No |
| 117 | CB_UTILITY_F4 ZN | 8.18 | 0.0 | N/A | 0.000 | 4.628 | 3.983 | 0.000 | 0.000 | 0.000 | 0.000 | 8.611 | No |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Number of People {} | People/Floor Area {person/m2} | Floor Area per person {m2/person} | Fraction Radiant | Fraction Convected | Sensible Fraction Calculation | Activity level | ASHRAE 55 Warnings | Carbon Dioxide Generation Rate | Nominal Minimum Number of People | Nominal Maximum Number of People | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 COLLEGE - LOUNGE PEOPLE | COLLEGE BLDG_CAFE_OCC_SCH | CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | 48.4 | 48.4 | 0.269 | 3.716 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 46 |
| 2 | CB_CLASSROOM_1_F4 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_1_F4 ZN | 75.25 | 52.7 | 52.7 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 |
| 3 | CB_CLASSROOM_2_F4 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_2_F4 ZN | 75.25 | 52.7 | 52.7 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 |
| 4 | CB_CLASSROOM_3_F4 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_3_F4 ZN | 75.25 | 52.7 | 52.7 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 |
| 5 | CB_CLASSROOM_5_F4 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_5_F4 ZN | 75.25 | 52.7 | 52.7 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 |
| 6 | CB_CLASSROOM_6_F4 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_6_F4 ZN | 75.25 | 52.7 | 52.7 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 |
| 7 | CB_CLASSROOM_7_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_7_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 8 | CB_CLASSROOM_6_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_6_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 9 | CB_CLASSROOM_5_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_5_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 10 | CB_CLASSROOM_4_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_4_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 11 | CB_CLASSROOM_3_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_3_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 12 | CB_CLASSROOM_5_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_5_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 13 | CB_CLASSROOM_1_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_1_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 14 | CB_CLASSROOM_2_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_2_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 15 | CB_CLASSROOM_8_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_8_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 16 | CB_CLASSROOM_6_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_6_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 17 | CB_CLASSROOM_7_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_7_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 18 | CB_CLASSROOM_8_F3 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_8_F3 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 19 | CB_CLASSROOM_4_F4 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_4_F4 ZN | 75.25 | 52.6 | 52.6 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 22 |
| 20 | CB_CLASSROOM_4_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_4_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 21 | CB_LECTURE_ROOM_2_F1 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_LECTURE_ROOM_2_F1 ZN | 150.50 | 105.3 | 105.3 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 44 |
| 22 | CB_CLASSROOM_2_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_2_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 23 | CB_CLASSROOM_1_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_1_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 24 | CB_CLASSROOM_3_F2 COLLEGE - CLASSROOM PEOPLE | COLLEGE BLDG_CLASS_OCC_SCH | CB_CLASSROOM_3_F2 ZN | 56.44 | 39.5 | 39.5 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 17 |
| 25 | CB_CONFERENCE_ROOM_F4 COLLEGE - CONFERENCE PEOPLE | COLLEGE BLDG_OCC_SCH | CB_CONFERENCE_ROOM_F4 ZN | 30.66 | 16.5 | 16.5 | 0.538 | 1.858 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 16 |
| 26 | CB_CONFERENCE_ROOM_F3 COLLEGE - CONFERENCE PEOPLE | COLLEGE BLDG_OCC_SCH | CB_CONFERENCE_ROOM_F3 ZN | 30.66 | 16.5 | 16.5 | 0.538 | 1.858 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 16 |
| 27 | CB_CONFERENCE_ROOM_F1 COLLEGE - CONFERENCE PEOPLE | COLLEGE BLDG_OCC_SCH | CB_CONFERENCE_ROOM_F1 ZN | 45.99 | 24.8 | 24.8 | 0.538 | 1.858 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 |
| 28 | CB_CONFERENCE_ROOM_F2 COLLEGE - CONFERENCE PEOPLE | COLLEGE BLDG_OCC_SCH | CB_CONFERENCE_ROOM_F2 ZN | 30.66 | 16.5 | 16.5 | 0.538 | 1.858 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 16 |
| 29 | CB_ENTRANCE_LOBBY_F1 COLLEGE - ENTRANCE LOBBY PEOPLE | COLLEGE BLDG_OCC_SCH | CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | 8.1 | 8.1 | 0.108 | 9.290 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 8 |
| 30 | CB_OFFICES_ENCLOSED_8_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 31 | CB_OFFICES_ENCLOSED_7_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 32 | CB_OFFICES_ENCLOSED_5_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 33 | CB_OFFICES_ENCLOSED_4_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 34 | CB_OFFICES_ENCLOSED_6_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 35 | CB_OFFICES_OPEN_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_OPEN_F4 ZN | 209.50 | 11.3 | 11.3 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 |
| 36 | CB_OFFICES_OPEN_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_OPEN_F1 ZN | 194.17 | 10.5 | 10.5 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 10 |
| 37 | CB_FACULTY_OFFICE_6_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 38 | CB_FACULTY_OFFICE_5_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 39 | CB_FACULTY_OFFICE_4_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 40 | CB_FACULTY_OFFICE_3_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 41 | CB_FACULTY_OFFICE_2_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 42 | CB_OFFICES_ENCLOSED_1_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 43 | CB_FACULTY_OFFICE_1_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 44 | CB_FACULTY_OFFICE_1_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 45 | CB_FACULTY_OFFICE_3_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 46 | CB_FACULTY_OFFICE_5_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 47 | CB_FACULTY_OFFICE_4_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 48 | CB_FACULTY_OFFICE_2_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 49 | CB_OFFICES_ENCLOSED_2_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 50 | CB_FACULTY_OFFICE_3_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 51 | CB_FACULTY_OFFICE_8_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 52 | CB_FACULTY_OFFICE_8_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 53 | CB_FACULTY_OFFICE_7_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 54 | CB_OFFICES_ENCLOSED_3_F1 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 55 | CB_FACULTY_OFFICE_6_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 56 | CB_FACULTY_OFFICE_6_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 57 | CB_FACULTY_OFFICE_7_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 58 | CB_FACULTY_OFFICE_7_F4 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 59 | CB_FACULTY_OFFICE_8_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 60 | CB_FACULTY_OFFICE_2_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 61 | CB_OFFICES_OPEN_F3 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_OPEN_F3 ZN | 209.50 | 11.3 | 11.3 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 |
| 62 | CB_FACULTY_OFFICE_4_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 63 | CB_OFFICES_OPEN_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_OFFICES_OPEN_F2 ZN | 209.50 | 11.3 | 11.3 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 11 |
| 64 | CB_FACULTY_OFFICE_5_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 65 | CB_FACULTY_OFFICE_1_F2 COLLEGE - OFFICE PEOPLE | COLLEGE BLDG_OCC_SCH_OFFICES | CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | 0.7 | 0.7 | 5.382E-002 | 18.581 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 1 |
| 66 | CB_LAB_3_F4 COLLEGE - LABORATORY PEOPLE | COLLEGE BLDG_LAB_OCC_SCH | CB_LAB_3_F4 ZN | 135.17 | 36.4 | 36.4 | 0.269 | 3.716 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 9 |
| 67 | CB_LAB_4_F4 COLLEGE - LABORATORY PEOPLE | COLLEGE BLDG_LAB_OCC_SCH | CB_LAB_4_F4 ZN | 135.17 | 36.4 | 36.4 | 0.269 | 3.716 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 9 |
| 68 | CB_LAB_1_F4 COLLEGE - LABORATORY PEOPLE | COLLEGE BLDG_LAB_OCC_SCH | CB_LAB_1_F4 ZN | 135.17 | 36.4 | 36.4 | 0.269 | 3.716 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 9 |
| 69 | CB_LAB_2_F4 COLLEGE - LABORATORY PEOPLE | COLLEGE BLDG_LAB_OCC_SCH | CB_LAB_2_F4 ZN | 135.17 | 36.4 | 36.4 | 0.269 | 3.716 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 9 |
| 70 | CB_LECTURE_ROOM_1_F1 COLLEGE - LECTURE HALL PEOPLE | COLLEGE BLDG_LECTURE_OCC_SCH | CB_LECTURE_ROOM_1_F1 ZN | 270.35 | 189.2 | 189.2 | 0.700 | 1.429 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 76 |
| 71 | CB_LIBRARY_MEDIA_CENTER_F1 COLLEGE - MEDIA CENTER PEOPLE | COLLEGE BLDG_LECTURE_OCC_SCH | CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | 29.1 | 29.1 | 0.108 | 9.290 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 12 |
| 72 | CB_STUDIO_1_F2 COLLEGE - ART CLASSROOM PEOPLE | COLLEGE BLDG_STUDIO_OCC_SCH | CB_STUDIO_1_F2 ZN | 299.61 | 64.5 | 64.5 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 |
| 73 | CB_STUDIO_1_F3 COLLEGE - ART CLASSROOM PEOPLE | COLLEGE BLDG_STUDIO_OCC_SCH | CB_STUDIO_1_F3 ZN | 299.61 | 64.5 | 64.5 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 |
| 74 | CB_STUDIO_2_F2 COLLEGE - ART CLASSROOM PEOPLE | COLLEGE BLDG_STUDIO_OCC_SCH | CB_STUDIO_2_F2 ZN | 299.61 | 64.5 | 64.5 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 |
| 75 | CB_STUDIO_2_F3 COLLEGE - ART CLASSROOM PEOPLE | COLLEGE BLDG_STUDIO_OCC_SCH | CB_STUDIO_2_F3 ZN | 299.61 | 64.5 | 64.5 | 0.215 | 4.645 | 0.300 | 0.700 | AutoCalculate | COLLEGE ACTIVITY_SCH | No | 3.8200E-008 | 0 | 24 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Lighting Level {W} | Lights/Floor Area {W/m2} | Lights per person {W/person} | Fraction Return Air | Fraction Radiant | Fraction Short Wave | Fraction Convected | Fraction Replaceable | End-Use Category | Nominal Minimum Lighting Level {W} | Nominal Maximum Lighting Level {W} | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 COLLEGE - LOUNGE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | 48.4 | 1141.650 | 6.351 | 23.600 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 202.415 | 1027.485 |
| 2 | CB_CLASSROOM_1_F4 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_1_F4 ZN | 75.25 | 52.7 | 575.100 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 101.965 | 517.590 |
| 3 | CB_CLASSROOM_2_F4 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_2_F4 ZN | 75.25 | 52.7 | 575.100 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 101.965 | 517.590 |
| 4 | CB_CLASSROOM_3_F4 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_3_F4 ZN | 75.25 | 52.7 | 575.100 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 101.965 | 517.590 |
| 5 | CB_CLASSROOM_5_F4 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_5_F4 ZN | 75.25 | 52.7 | 575.100 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 101.965 | 517.590 |
| 6 | CB_CLASSROOM_6_F4 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_6_F4 ZN | 75.25 | 52.7 | 575.100 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 101.965 | 517.590 |
| 7 | CB_CLASSROOM_7_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_7_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 8 | CB_CLASSROOM_6_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_6_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 9 | CB_CLASSROOM_5_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_5_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 10 | CB_CLASSROOM_4_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_4_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 11 | CB_CLASSROOM_3_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_3_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 12 | CB_CLASSROOM_5_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_5_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 13 | CB_CLASSROOM_1_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_1_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 14 | CB_CLASSROOM_2_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_2_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 15 | CB_CLASSROOM_8_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_8_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 16 | CB_CLASSROOM_6_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_6_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 17 | CB_CLASSROOM_7_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_7_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 18 | CB_CLASSROOM_8_F3 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_8_F3 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 19 | CB_CLASSROOM_4_F4 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_4_F4 ZN | 75.25 | 52.6 | 575.100 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 101.965 | 517.590 |
| 20 | CB_CLASSROOM_4_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_4_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 21 | CB_LECTURE_ROOM_2_F1 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LECTURE_ROOM_2_F1 ZN | 150.50 | 105.3 | 1150.200 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 203.930 | 1035.180 |
| 22 | CB_CLASSROOM_2_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_2_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 23 | CB_CLASSROOM_1_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_1_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.192 |
| 24 | CB_CLASSROOM_3_F2 COLLEGE - CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CLASSROOM_3_F2 ZN | 56.44 | 39.5 | 431.325 | 7.642 | 10.923 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 76.474 | 388.193 |
| 25 | CB_CONFERENCE_ROOM_F4 COLLEGE - CONFERENCE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CONFERENCE_ROOM_F4 ZN | 30.66 | 16.5 | 320.100 | 10.441 | 19.400 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 56.754 | 288.090 |
| 26 | CB_CONFERENCE_ROOM_F3 COLLEGE - CONFERENCE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CONFERENCE_ROOM_F3 ZN | 30.66 | 16.5 | 320.100 | 10.441 | 19.400 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 56.754 | 288.090 |
| 27 | CB_CONFERENCE_ROOM_F1 COLLEGE - CONFERENCE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CONFERENCE_ROOM_F1 ZN | 45.99 | 24.8 | 480.150 | 10.441 | 19.400 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 85.131 | 432.135 |
| 28 | CB_CONFERENCE_ROOM_F2 COLLEGE - CONFERENCE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CONFERENCE_ROOM_F2 ZN | 30.66 | 16.5 | 320.100 | 10.441 | 19.400 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 56.754 | 288.090 |
| 29 | CB_CORRIDOR_F1 COLLEGE - CORRIDOR LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CORRIDOR_F1 ZN | 122.17 | 0.0 | 539.150 | 4.413 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 95.591 | 485.235 |
| 30 | CB_CORRIDOR_F4 COLLEGE - CORRIDOR LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CORRIDOR_F4 ZN | 151.43 | 0.0 | 668.300 | 4.413 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 118.490 | 601.470 |
| 31 | CB_CORRIDOR_F2 COLLEGE - CORRIDOR LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CORRIDOR_F2 ZN | 92.90 | 0.0 | 410.000 | 4.413 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 72.693 | 369.000 |
| 32 | CB_CORRIDOR_2_F3 COLLEGE - CORRIDOR LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CORRIDOR_2_F3 ZN | 61.32 | 0.0 | 270.600 | 4.413 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 47.977 | 243.540 |
| 33 | CB_CORRIDOR_1_F3 COLLEGE - CORRIDOR LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_CORRIDOR_1_F3 ZN | 31.59 | 0.0 | 139.400 | 4.413 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 24.716 | 125.460 |
| 34 | CB_OFFICES_ENCLOSED_8_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 35 | CB_OFFICES_ENCLOSED_7_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 36 | CB_OFFICES_ENCLOSED_5_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 37 | CB_OFFICES_ENCLOSED_4_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 38 | CB_OFFICES_ENCLOSED_6_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 39 | CB_OFFICES_OPEN_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_OPEN_F4 ZN | 209.50 | 11.3 | 1668.700 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 295.861 | 1501.830 |
| 40 | CB_OFFICES_OPEN_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_OPEN_F1 ZN | 194.17 | 10.5 | 1546.600 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 274.212 | 1391.940 |
| 41 | CB_FACULTY_OFFICE_6_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 42 | CB_FACULTY_OFFICE_5_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 43 | CB_FACULTY_OFFICE_4_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 44 | CB_FACULTY_OFFICE_3_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 45 | CB_FACULTY_OFFICE_2_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 46 | CB_OFFICES_ENCLOSED_1_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 47 | CB_FACULTY_OFFICE_1_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 48 | CB_FACULTY_OFFICE_1_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 49 | CB_FACULTY_OFFICE_3_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 50 | CB_FACULTY_OFFICE_5_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 51 | CB_FACULTY_OFFICE_4_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 52 | CB_FACULTY_OFFICE_2_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 53 | CB_OFFICES_ENCLOSED_2_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 54 | CB_FACULTY_OFFICE_3_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 55 | CB_FACULTY_OFFICE_8_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 56 | CB_FACULTY_OFFICE_8_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 57 | CB_FACULTY_OFFICE_7_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 58 | CB_OFFICES_ENCLOSED_3_F1 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 59 | CB_FACULTY_OFFICE_6_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 60 | CB_FACULTY_OFFICE_6_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 61 | CB_FACULTY_OFFICE_7_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 62 | CB_FACULTY_OFFICE_7_F4 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 63 | CB_FACULTY_OFFICE_8_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 64 | CB_FACULTY_OFFICE_2_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 65 | CB_OFFICES_OPEN_F3 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_OPEN_F3 ZN | 209.50 | 11.3 | 1668.700 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 295.861 | 1501.830 |
| 66 | CB_FACULTY_OFFICE_4_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 67 | CB_OFFICES_OPEN_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_OFFICES_OPEN_F2 ZN | 209.50 | 11.3 | 1668.700 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 295.861 | 1501.830 |
| 68 | CB_FACULTY_OFFICE_5_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 69 | CB_FACULTY_OFFICE_1_F2 COLLEGE - OFFICE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | 0.7 | 97.680 | 7.965 | 148.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.319 | 87.912 |
| 70 | CB_STUDENTS_RESTROOMS_1_F1 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_1_F1 ZN | 19.16 | 0.0 | 129.938 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 71 | CB_STAFF_RESTROOMS_1_F1 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STAFF_RESTROOMS_1_F1 ZN | 9.96 | 0.0 | 67.568 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 72 | CB_FACULTY_RESTROOMS_2_F4 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_RESTROOMS_2_F4 ZN | 9.96 | 0.0 | 67.568 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 73 | CB_STUDENTS_RESTROOMS_1_F4 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_1_F4 ZN | 19.16 | 0.0 | 129.938 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 74 | CB_STUDENTS_RESTROOMS_2_F4 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_2_F4 ZN | 19.16 | 0.0 | 129.938 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 75 | CB_FACULTY_RESTROOMS_1_F4 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_RESTROOMS_1_F4 ZN | 9.96 | 0.0 | 67.568 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 76 | CB_STUDENTS_RESTROOMS_1_F3 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_1_F3 ZN | 19.16 | 0.0 | 129.937 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 77 | CB_FACULTY_RESTROOMS_1_F3 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_RESTROOMS_1_F3 ZN | 9.96 | 0.0 | 67.567 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 78 | CB_STUDENTS_RESTROOMS_2_F3 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_2_F3 ZN | 19.16 | 0.0 | 129.937 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 79 | CB_FACULTY_RESTROOMS_2_F3 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_RESTROOMS_2_F3 ZN | 9.96 | 0.0 | 67.567 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 80 | CB_STAFF_RESTROOMS_2_F1 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STAFF_RESTROOMS_2_F1 ZN | 9.96 | 0.0 | 67.568 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 81 | CB_FACULTY_RESTROOMS_2_F2 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_RESTROOMS_2_F2 ZN | 9.96 | 0.0 | 67.568 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 82 | CB_FACULTY_RESTROOMS_1_F2 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_FACULTY_RESTROOMS_1_F2 ZN | 9.96 | 0.0 | 67.568 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.980 | 60.811 |
| 83 | CB_STUDENTS_RESTROOMS_2_F1 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_2_F1 ZN | 19.16 | 0.0 | 129.938 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 84 | CB_STUDENTS_RESTROOMS_2_F2 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_2_F2 ZN | 19.16 | 0.0 | 129.938 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 85 | CB_STUDENTS_RESTROOMS_1_F2 COLLEGE - RESTROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDENTS_RESTROOMS_1_F2 ZN | 19.16 | 0.0 | 129.938 | 6.781 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 23.038 | 116.944 |
| 86 | CB_LAB_3_F4 COLLEGE - LABORATORY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LAB_3_F4 ZN | 135.17 | 36.4 | 1935.150 | 14.316 | 53.200 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 343.102 | 1741.635 |
| 87 | CB_LAB_4_F4 COLLEGE - LABORATORY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LAB_4_F4 ZN | 135.17 | 36.4 | 1935.150 | 14.316 | 53.200 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 343.102 | 1741.635 |
| 88 | CB_LAB_1_F4 COLLEGE - LABORATORY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LAB_1_F4 ZN | 135.17 | 36.4 | 1935.150 | 14.316 | 53.200 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 343.102 | 1741.635 |
| 89 | CB_LAB_2_F4 COLLEGE - LABORATORY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LAB_2_F4 ZN | 135.17 | 36.4 | 1935.150 | 14.316 | 53.200 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 343.102 | 1741.635 |
| 90 | CB_LECTURE_ROOM_1_F1 COLLEGE - LECTURE HALL LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LECTURE_ROOM_1_F1 ZN | 270.35 | 189.2 | 1775.100 | 6.566 | 9.385 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 314.725 | 1597.590 |
| 91 | CB_LIBRARY_MEDIA_CENTER_F1 COLLEGE - MEDIA CENTER LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | 29.1 | 2415.300 | 8.934 | 83.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 428.233 | 2173.770 |
| 92 | CB_MAIN_STAIRS_F4 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_MAIN_STAIRS_F4 ZN | 18.58 | 0.0 | 98.000 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.375 | 88.200 |
| 93 | CB_SECONDARY_STAIRS_2_F4 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_2_F4 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 94 | CB_SECONDARY_STAIRS_2_F1 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_2_F1 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 95 | CB_SECONDARY_STAIRS_1_F4 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_1_F4 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 96 | CB_MAIN_STAIRS_F3 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_MAIN_STAIRS_F3 ZN | 18.58 | 0.0 | 98.000 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.375 | 88.200 |
| 97 | CB_MAIN_STAIRS_F2 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_MAIN_STAIRS_F2 ZN | 18.58 | 0.0 | 98.000 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.375 | 88.200 |
| 98 | CB_SECONDARY_STAIRS_2_F2 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_2_F2 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 99 | CB_SECONDARY_STAIRS_2_F3 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_2_F3 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 100 | CB_SECONDARY_STAIRS_1_F1 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_1_F1 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 101 | CB_SECONDARY_STAIRS_1_F3 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_1_F3 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 102 | CB_SECONDARY_STAIRS_1_F2 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_SECONDARY_STAIRS_1_F2 ZN | 12.54 | 0.0 | 66.150 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 11.728 | 59.535 |
| 103 | CB_MAIN_STAIRS_F1 COLLEGE - STAIRS LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_MAIN_STAIRS_F1 ZN | 18.58 | 0.0 | 98.000 | 5.274 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 17.375 | 88.200 |
| 104 | CB_STORAGE_F1 COLLEGE - STORAGE LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STORAGE_F1 ZN | 75.25 | 0.0 | 307.800 | 4.090 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 54.573 | 277.020 |
| 105 | CB_STUDIO_1_F2 COLLEGE - ART CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDIO_1_F2 ZN | 299.61 | 64.5 | 2289.750 | 7.642 | 35.500 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 405.973 | 2060.775 |
| 106 | CB_STUDIO_1_F3 COLLEGE - ART CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDIO_1_F3 ZN | 299.61 | 64.5 | 2289.750 | 7.642 | 35.500 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 405.973 | 2060.775 |
| 107 | CB_STUDIO_2_F2 COLLEGE - ART CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDIO_2_F2 ZN | 299.61 | 64.5 | 2289.750 | 7.642 | 35.500 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 405.973 | 2060.775 |
| 108 | CB_STUDIO_2_F3 COLLEGE - ART CLASSROOM LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_STUDIO_2_F3 ZN | 299.61 | 64.5 | 2289.750 | 7.642 | 35.500 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 405.973 | 2060.775 |
| 109 | CB_UTILITY_F1 COLLEGE - UTILITY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_UTILITY_F1 ZN | 8.18 | 0.0 | 37.840 | 4.628 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 6.709 | 34.056 |
| 110 | CB_UTILITY_F4 COLLEGE - UTILITY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_UTILITY_F4 ZN | 8.18 | 0.0 | 37.840 | 4.628 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 6.709 | 34.056 |
| 111 | CB_UTILITY_F3 COLLEGE - UTILITY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_UTILITY_F3 ZN | 8.18 | 0.0 | 37.840 | 4.628 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 6.709 | 34.056 |
| 112 | CB_UTILITY_F2 COLLEGE - UTILITY LIGHTS | COLLEGE BLDG_LIGHT_SCH | CB_UTILITY_F2 ZN | 8.18 | 0.0 | 37.840 | 4.628 | N/A | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | General | 6.709 | 34.056 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Equipment Level {W} | Equipment/Floor Area {W/m2} | Equipment per person {W/person} | Fraction Latent | Fraction Radiant | Fraction Lost | Fraction Convected | End-Use SubCategory | Nominal Minimum Equipment Level {W} | Nominal Maximum Equipment Level {W} | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 COLLEGE - LOUNGE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | 48.4 | 13835.250 | 76.962 | 286.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 4150.575 | 13835.250 |
| 2 | CB_CLASSROOM_1_F4 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_1_F4 ZN | 75.25 | 52.7 | 752.490 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 225.747 | 752.490 |
| 3 | CB_CLASSROOM_2_F4 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_2_F4 ZN | 75.25 | 52.7 | 752.490 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 225.747 | 752.490 |
| 4 | CB_CLASSROOM_3_F4 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_3_F4 ZN | 75.25 | 52.7 | 752.490 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 225.747 | 752.490 |
| 5 | CB_CLASSROOM_5_F4 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_5_F4 ZN | 75.25 | 52.7 | 752.490 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 225.747 | 752.490 |
| 6 | CB_CLASSROOM_6_F4 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_6_F4 ZN | 75.25 | 52.7 | 752.490 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 225.747 | 752.490 |
| 7 | CB_CLASSROOM_7_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_7_F2 ZN | 56.44 | 39.5 | 564.367 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.367 |
| 8 | CB_CLASSROOM_6_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_6_F2 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 9 | CB_CLASSROOM_5_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_5_F2 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 10 | CB_CLASSROOM_4_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_4_F3 ZN | 56.44 | 39.5 | 564.367 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.367 |
| 11 | CB_CLASSROOM_3_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_3_F3 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 12 | CB_CLASSROOM_5_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_5_F3 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 13 | CB_CLASSROOM_1_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_1_F3 ZN | 56.44 | 39.5 | 564.367 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.367 |
| 14 | CB_CLASSROOM_2_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_2_F3 ZN | 56.44 | 39.5 | 564.367 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.367 |
| 15 | CB_CLASSROOM_8_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_8_F2 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 16 | CB_CLASSROOM_6_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_6_F3 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 17 | CB_CLASSROOM_7_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_7_F3 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 18 | CB_CLASSROOM_8_F3 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_8_F3 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 19 | CB_CLASSROOM_4_F4 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_4_F4 ZN | 75.25 | 52.6 | 752.490 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 225.747 | 752.490 |
| 20 | CB_CLASSROOM_4_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_4_F2 ZN | 56.44 | 39.5 | 564.367 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.367 |
| 21 | CB_LECTURE_ROOM_2_F1 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LECTURE_ROOM_2_F1 ZN | 150.50 | 105.3 | 1504.980 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 451.494 | 1504.980 |
| 22 | CB_CLASSROOM_2_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_2_F2 ZN | 56.44 | 39.5 | 564.367 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.367 |
| 23 | CB_CLASSROOM_1_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_1_F2 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 24 | CB_CLASSROOM_3_F2 COLLEGE - CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CLASSROOM_3_F2 ZN | 56.44 | 39.5 | 564.368 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 169.310 | 564.368 |
| 25 | CB_CONFERENCE_ROOM_F4 COLLEGE - CONFERENCE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CONFERENCE_ROOM_F4 ZN | 30.66 | 16.5 | 330.000 | 10.764 | 20.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 99.000 | 330.000 |
| 26 | CB_CONFERENCE_ROOM_F3 COLLEGE - CONFERENCE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CONFERENCE_ROOM_F3 ZN | 30.66 | 16.5 | 330.000 | 10.764 | 20.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 99.000 | 330.000 |
| 27 | CB_CONFERENCE_ROOM_F1 COLLEGE - CONFERENCE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CONFERENCE_ROOM_F1 ZN | 45.99 | 24.8 | 495.000 | 10.764 | 20.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 148.500 | 495.000 |
| 28 | CB_CONFERENCE_ROOM_F2 COLLEGE - CONFERENCE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CONFERENCE_ROOM_F2 ZN | 30.66 | 16.5 | 330.000 | 10.764 | 20.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 99.000 | 330.000 |
| 29 | CB_CORRIDOR_F1 COLLEGE - CORRIDOR ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CORRIDOR_F1 ZN | 122.17 | 0.0 | 486.550 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 145.965 | 486.550 |
| 30 | CB_CORRIDOR_F4 COLLEGE - CORRIDOR ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CORRIDOR_F4 ZN | 151.43 | 0.0 | 603.100 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 180.930 | 603.100 |
| 31 | CB_CORRIDOR_F2 COLLEGE - CORRIDOR ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CORRIDOR_F2 ZN | 92.90 | 0.0 | 370.000 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 111.000 | 370.000 |
| 32 | CB_CORRIDOR_2_F3 COLLEGE - CORRIDOR ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CORRIDOR_2_F3 ZN | 61.32 | 0.0 | 244.200 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 73.260 | 244.200 |
| 33 | CB_CORRIDOR_1_F3 COLLEGE - CORRIDOR ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_CORRIDOR_1_F3 ZN | 31.59 | 0.0 | 125.800 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 37.740 | 125.800 |
| 34 | CB_ENTRANCE_LOBBY_F1 COLLEGE - ENTRANCE LOBBY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | 8.1 | 299.700 | 3.983 | 37.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 89.910 | 299.700 |
| 35 | CB_OFFICES_ENCLOSED_8_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 36 | CB_OFFICES_ENCLOSED_7_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 37 | CB_OFFICES_ENCLOSED_5_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 38 | CB_OFFICES_ENCLOSED_4_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 39 | CB_OFFICES_ENCLOSED_6_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 40 | CB_OFFICES_OPEN_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_OPEN_F4 ZN | 209.50 | 11.3 | 2255.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 676.500 | 2255.000 |
| 41 | CB_OFFICES_OPEN_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_OPEN_F1 ZN | 194.17 | 10.5 | 2090.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 627.000 | 2090.000 |
| 42 | CB_FACULTY_OFFICE_6_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 43 | CB_FACULTY_OFFICE_5_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 44 | CB_FACULTY_OFFICE_4_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 45 | CB_FACULTY_OFFICE_3_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 46 | CB_FACULTY_OFFICE_2_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 47 | CB_OFFICES_ENCLOSED_1_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 48 | CB_FACULTY_OFFICE_1_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 49 | CB_FACULTY_OFFICE_1_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 50 | CB_FACULTY_OFFICE_3_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 51 | CB_FACULTY_OFFICE_5_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 52 | CB_FACULTY_OFFICE_4_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 53 | CB_FACULTY_OFFICE_2_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 54 | CB_OFFICES_ENCLOSED_2_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 55 | CB_FACULTY_OFFICE_3_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 56 | CB_FACULTY_OFFICE_8_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 57 | CB_FACULTY_OFFICE_8_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 58 | CB_FACULTY_OFFICE_7_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 59 | CB_OFFICES_ENCLOSED_3_F1 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 60 | CB_FACULTY_OFFICE_6_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 61 | CB_FACULTY_OFFICE_6_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 62 | CB_FACULTY_OFFICE_7_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 63 | CB_FACULTY_OFFICE_7_F4 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 64 | CB_FACULTY_OFFICE_8_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 65 | CB_FACULTY_OFFICE_2_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 66 | CB_OFFICES_OPEN_F3 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_OPEN_F3 ZN | 209.50 | 11.3 | 2255.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 676.500 | 2255.000 |
| 67 | CB_FACULTY_OFFICE_4_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 68 | CB_OFFICES_OPEN_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_OFFICES_OPEN_F2 ZN | 209.50 | 11.3 | 2255.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 676.500 | 2255.000 |
| 69 | CB_FACULTY_OFFICE_5_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 70 | CB_FACULTY_OFFICE_1_F2 COLLEGE - OFFICE ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | 0.7 | 132.000 | 10.764 | 200.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 39.600 | 132.000 |
| 71 | CB_STUDENTS_RESTROOMS_1_F1 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_1_F1 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 72 | CB_STAFF_RESTROOMS_1_F1 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STAFF_RESTROOMS_1_F1 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 73 | CB_FACULTY_RESTROOMS_2_F4 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_RESTROOMS_2_F4 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 74 | CB_STUDENTS_RESTROOMS_1_F4 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_1_F4 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 75 | CB_STUDENTS_RESTROOMS_2_F4 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_2_F4 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 76 | CB_FACULTY_RESTROOMS_1_F4 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_RESTROOMS_1_F4 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 77 | CB_STUDENTS_RESTROOMS_1_F3 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_1_F3 ZN | 19.16 | 0.0 | 76.312 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.312 |
| 78 | CB_FACULTY_RESTROOMS_1_F3 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_RESTROOMS_1_F3 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 79 | CB_STUDENTS_RESTROOMS_2_F3 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_2_F3 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 80 | CB_FACULTY_RESTROOMS_2_F3 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_RESTROOMS_2_F3 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 81 | CB_STAFF_RESTROOMS_2_F1 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STAFF_RESTROOMS_2_F1 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 82 | CB_FACULTY_RESTROOMS_2_F2 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_RESTROOMS_2_F2 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 83 | CB_FACULTY_RESTROOMS_1_F2 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_FACULTY_RESTROOMS_1_F2 ZN | 9.96 | 0.0 | 39.683 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 11.905 | 39.683 |
| 84 | CB_STUDENTS_RESTROOMS_2_F1 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_2_F1 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 85 | CB_STUDENTS_RESTROOMS_2_F2 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_2_F2 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 86 | CB_STUDENTS_RESTROOMS_1_F2 COLLEGE - RESTROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDENTS_RESTROOMS_1_F2 ZN | 19.16 | 0.0 | 76.313 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 22.894 | 76.313 |
| 87 | CB_LAB_3_F4 COLLEGE - LABORATORY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LAB_3_F4 ZN | 135.17 | 36.4 | 5820.000 | 43.056 | 160.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 1746.000 | 5820.000 |
| 88 | CB_LAB_4_F4 COLLEGE - LABORATORY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LAB_4_F4 ZN | 135.17 | 36.4 | 5820.000 | 43.056 | 160.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 1746.000 | 5820.000 |
| 89 | CB_LAB_1_F4 COLLEGE - LABORATORY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LAB_1_F4 ZN | 135.17 | 36.4 | 5820.000 | 43.056 | 160.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 1746.000 | 5820.000 |
| 90 | CB_LAB_2_F4 COLLEGE - LABORATORY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LAB_2_F4 ZN | 135.17 | 36.4 | 5820.000 | 43.056 | 160.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 1746.000 | 5820.000 |
| 91 | CB_LECTURE_ROOM_1_F1 COLLEGE - LECTURE HALL ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LECTURE_ROOM_1_F1 ZN | 270.35 | 189.2 | 2703.390 | 10.000 | 14.292 | 0.000 | 0.500 | 0.000 | 0.500 | General | 811.017 | 2703.390 |
| 92 | CB_LIBRARY_MEDIA_CENTER_F1 COLLEGE - MEDIA CENTER ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | 29.1 | 2706.300 | 10.010 | 93.000 | 0.000 | 0.500 | 0.000 | 0.500 | General | 811.890 | 2706.300 |
| 93 | 2 ELEVATOR FANS | COLLEGE ELEV_LIGHT_FAN_SCH_24_7 | CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | 0.0 | 61.915 | 5.207 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | Elevators | 61.915 | 61.915 |
| 94 | 2 ELEVATOR LIFT MOTORS | COLLEGE BLDG_ELEVATORS | CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | 0.0 | 32110.000 | 2700.228 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | Elevators | 0.000 | 9633.000 |
| 95 | 2 ELEVATOR LIGHTS | COLLEGE ELEV_LIGHT_FAN_SCH_24_7 | CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | 0.0 | 64.697 | 5.441 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | Elevators | 64.697 | 64.697 |
| 96 | CB_STUDIO_1_F2 COLLEGE - ART CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDIO_1_F2 ZN | 299.61 | 64.5 | 2996.025 | 10.000 | 46.450 | 0.000 | 0.500 | 0.000 | 0.500 | General | 898.808 | 2996.025 |
| 97 | CB_STUDIO_1_F3 COLLEGE - ART CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDIO_1_F3 ZN | 299.61 | 64.5 | 2996.025 | 10.000 | 46.450 | 0.000 | 0.500 | 0.000 | 0.500 | General | 898.807 | 2996.025 |
| 98 | CB_STUDIO_2_F2 COLLEGE - ART CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDIO_2_F2 ZN | 299.61 | 64.5 | 2996.025 | 10.000 | 46.450 | 0.000 | 0.500 | 0.000 | 0.500 | General | 898.808 | 2996.025 |
| 99 | CB_STUDIO_2_F3 COLLEGE - ART CLASSROOM ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_STUDIO_2_F3 ZN | 299.61 | 64.5 | 2996.025 | 10.000 | 46.450 | 0.000 | 0.500 | 0.000 | 0.500 | General | 898.808 | 2996.025 |
| 100 | CB_UTILITY_F1 COLLEGE - UTILITY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_UTILITY_F1 ZN | 8.18 | 0.0 | 32.560 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 9.768 | 32.560 |
| 101 | CB_UTILITY_F4 COLLEGE - UTILITY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_UTILITY_F4 ZN | 8.18 | 0.0 | 32.560 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 9.768 | 32.560 |
| 102 | CB_UTILITY_F3 COLLEGE - UTILITY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_UTILITY_F3 ZN | 8.18 | 0.0 | 32.560 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 9.768 | 32.560 |
| 103 | CB_UTILITY_F2 COLLEGE - UTILITY ELEC EQUIP | COLLEGE BLDG_EQUIP_SCH_BASE | CB_UTILITY_F2 ZN | 8.18 | 0.0 | 32.560 | 3.983 | N/A | 0.000 | 0.500 | 0.000 | 0.500 | General | 9.768 | 32.560 |
| Shading Calculation Method | Shading Calculation Update Frequency Method | Shading Calculation Update Frequency {days} | Maximum Figures in Shadow Overlap Calculations {} | Polygon Clipping Algorithm | Pixel Counting Resolution | Sky Diffuse Modeling Algorithm | Output External Shading Calculation Results | Disable Self-Shading Within Shading Zone Groups | Disable Self-Shading From Shading Zone Groups to Other Zones | |
| 1 | PolygonClipping | Periodic | 20 | 15000 | SutherlandHodgman | 512 | SimpleSkyDiffuseModeling | No | No | No |
| Enclosure Name | Number of Exterior Windows | Number of Exterior Windows in Adjacent Enclosures | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 | 2 | 0 |
| 2 | CB_CLASSROOM_1_F2 | 2 | 0 |
| 3 | CB_CLASSROOM_1_F3 | 2 | 0 |
| 4 | CB_CLASSROOM_1_F4 | 2 | 0 |
| 5 | CB_CLASSROOM_2_F4 | 1 | 0 |
| 6 | CB_CLASSROOM_3_F4 | 1 | 0 |
| 7 | CB_CLASSROOM_4_F4 | 1 | 0 |
| 8 | CB_CLASSROOM_5_F4 | 1 | 0 |
| 9 | CB_CLASSROOM_6_F4 | 2 | 0 |
| 10 | CB_CLASSROOM_8_F2 | 2 | 0 |
| 11 | CB_CLASSROOM_8_F3 | 2 | 0 |
| 12 | CB_LAB_1_F4 | 2 | 0 |
| 13 | CB_LAB_2_F4 | 1 | 0 |
| 14 | CB_LAB_3_F4 | 1 | 0 |
| 15 | CB_LAB_4_F4 | 2 | 0 |
| 16 | CB_LECTURE_ROOM_1_F1 | 2 | 0 |
| 17 | CB_LECTURE_ROOM_2_F1 | 2 | 0 |
| 18 | CB_LIBRARY_MEDIA_CENTER_F1 | 2 | 0 |
| 19 | CB_STUDIO_1_F2 | 2 | 0 |
| 20 | CB_STUDIO_1_F3 | 2 | 0 |
| 21 | CB_STUDIO_2_F2 | 2 | 0 |
| 22 | CB_STUDIO_2_F3 | 2 | 0 |
| Enclosure Name | Number of Adjacent Enclosures with Windows | Adjacent Enclosure Names - 1st 100 (max) | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 | 0 | |
| 2 | CB_CLASSROOM_1_F2 | 0 | |
| 3 | CB_CLASSROOM_1_F3 | 0 | |
| 4 | CB_CLASSROOM_1_F4 | 0 | |
| 5 | CB_CLASSROOM_2_F4 | 0 | |
| 6 | CB_CLASSROOM_3_F4 | 0 | |
| 7 | CB_CLASSROOM_4_F4 | 0 | |
| 8 | CB_CLASSROOM_5_F4 | 0 | |
| 9 | CB_CLASSROOM_6_F4 | 0 | |
| 10 | CB_CLASSROOM_8_F2 | 0 | |
| 11 | CB_CLASSROOM_8_F3 | 0 | |
| 12 | CB_LAB_1_F4 | 0 | |
| 13 | CB_LAB_2_F4 | 0 | |
| 14 | CB_LAB_3_F4 | 0 | |
| 15 | CB_LAB_4_F4 | 0 | |
| 16 | CB_LECTURE_ROOM_1_F1 | 0 | |
| 17 | CB_LECTURE_ROOM_2_F1 | 0 | |
| 18 | CB_LIBRARY_MEDIA_CENTER_F1 | 0 | |
| 19 | CB_STUDIO_1_F2 | 0 | |
| 20 | CB_STUDIO_1_F3 | 0 | |
| 21 | CB_STUDIO_2_F2 | 0 | |
| 22 | CB_STUDIO_2_F3 | 0 |
| Type | Name | Volume {m3} | Maximum Capacity {W} | Standard Rated Recovery Efficiency | Standard Rated Energy Factor | |
| 1 | WaterHeater:Mixed | 300GAL NATURAL GAS WATER HEATER - 300KBTU/HR 0.804 THERM EFF | 1.1356 | 87921.3 | 0.481 | 5.5005E-002 |
| Name | Schedule Name | Zone Name | Zone Floor Area {m2} | # Zone Occupants | Design Volume Flow Rate {m3/s} | Volume Flow Rate/Floor Area {m3/s-m2} | Volume Flow Rate/Exterior Surface Area {m3/s-m2} | ACH - Air Changes per Hour | Equation A - Constant Term Coefficient {} | Equation B - Temperature Term Coefficient {1/C} | Equation C - Velocity Term Coefficient {s/m} | Equation D - Velocity Squared Term Coefficient {s2/m2} | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | 48.4 | 5.985E-002 | 3.329E-004 | 5.696E-004 | 0.302 | 0.000 | 0.000 | 0.224 | 0.000 |
| 2 | CB_CLASSROOM_1_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_1_F2 ZN | 56.44 | 39.5 | 3.405E-002 | 6.033E-004 | 5.696E-004 | 0.548 | 0.000 | 0.000 | 0.224 | 0.000 |
| 3 | CB_CLASSROOM_1_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_1_F3 ZN | 56.44 | 39.5 | 3.405E-002 | 6.033E-004 | 5.696E-004 | 0.548 | 0.000 | 0.000 | 0.224 | 0.000 |
| 4 | CB_CLASSROOM_1_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_1_F4 ZN | 75.25 | 52.7 | 3.921E-002 | 5.211E-004 | 2.721E-004 | 0.473 | 0.000 | 0.000 | 0.224 | 0.000 |
| 5 | CB_CLASSROOM_2_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_2_F2 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 6 | CB_CLASSROOM_2_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_2_F3 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 7 | CB_CLASSROOM_2_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_2_F4 ZN | 75.25 | 52.7 | 2.064E-002 | 2.742E-004 | 1.851E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 8 | CB_CLASSROOM_3_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_3_F2 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 9 | CB_CLASSROOM_3_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_3_F3 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 10 | CB_CLASSROOM_3_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_3_F4 ZN | 75.25 | 52.7 | 2.064E-002 | 2.742E-004 | 1.851E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 11 | CB_CLASSROOM_4_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_4_F2 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 12 | CB_CLASSROOM_4_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_4_F3 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 13 | CB_CLASSROOM_4_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_4_F4 ZN | 75.25 | 52.6 | 2.064E-002 | 2.742E-004 | 1.851E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 14 | CB_CLASSROOM_5_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_5_F2 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 15 | CB_CLASSROOM_5_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_5_F3 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 16 | CB_CLASSROOM_5_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_5_F4 ZN | 75.25 | 52.7 | 2.064E-002 | 2.742E-004 | 1.851E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 17 | CB_CLASSROOM_6_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_6_F2 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 18 | CB_CLASSROOM_6_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_6_F3 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 19 | CB_CLASSROOM_6_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_6_F4 ZN | 75.25 | 52.7 | 3.921E-002 | 5.211E-004 | 2.721E-004 | 0.473 | 0.000 | 0.000 | 0.224 | 0.000 |
| 20 | CB_CLASSROOM_7_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_7_F2 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 21 | CB_CLASSROOM_7_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_7_F3 ZN | 56.44 | 39.5 | 1.548E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 22 | CB_CLASSROOM_8_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_8_F2 ZN | 56.44 | 39.5 | 3.405E-002 | 6.033E-004 | 5.696E-004 | 0.548 | 0.000 | 0.000 | 0.224 | 0.000 |
| 23 | CB_CLASSROOM_8_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CLASSROOM_8_F3 ZN | 56.44 | 39.5 | 3.405E-002 | 6.033E-004 | 5.696E-004 | 0.548 | 0.000 | 0.000 | 0.224 | 0.000 |
| 24 | CB_CORRIDOR_1_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CORRIDOR_1_F3 ZN | 31.59 | 0.0 | 6.879E-003 | 2.178E-004 | 5.696E-004 | 0.198 | 0.000 | 0.000 | 0.224 | 0.000 |
| 25 | CB_CORRIDOR_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CORRIDOR_F1 ZN | 122.17 | 0.0 | 6.879E-003 | 5.631E-005 | 5.696E-004 | 3.877E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 26 | CB_CORRIDOR_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CORRIDOR_F2 ZN | 92.90 | 0.0 | 6.879E-003 | 7.404E-005 | 5.696E-004 | 6.727E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 27 | CB_CORRIDOR_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_CORRIDOR_F4 ZN | 151.43 | 0.0 | 6.879E-003 | 4.543E-005 | 4.207E-005 | 4.127E-002 | 0.000 | 0.000 | 0.224 | 0.000 |
| 28 | CB_ENTRANCE_LOBBY_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | 8.1 | 2.064E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 29 | ENTRY DOOR INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | 8.1 | 0.000 | 0.000 | 0.000 | 0.000 | 1.000 | 0.000 | 0.000 | 0.000 |
| 30 | CB_FACULTY_OFFICE_1_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 31 | CB_FACULTY_OFFICE_1_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 32 | CB_FACULTY_OFFICE_1_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 33 | CB_FACULTY_OFFICE_2_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 34 | CB_FACULTY_OFFICE_2_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 35 | CB_FACULTY_OFFICE_2_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 36 | CB_FACULTY_OFFICE_3_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 37 | CB_FACULTY_OFFICE_3_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 38 | CB_FACULTY_OFFICE_3_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 39 | CB_FACULTY_OFFICE_4_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 40 | CB_FACULTY_OFFICE_4_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 41 | CB_FACULTY_OFFICE_4_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 42 | CB_FACULTY_OFFICE_5_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 43 | CB_FACULTY_OFFICE_5_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 44 | CB_FACULTY_OFFICE_5_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 45 | CB_FACULTY_OFFICE_6_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 46 | CB_FACULTY_OFFICE_6_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 47 | CB_FACULTY_OFFICE_6_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 48 | CB_FACULTY_OFFICE_7_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 49 | CB_FACULTY_OFFICE_7_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 50 | CB_FACULTY_OFFICE_7_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 51 | CB_FACULTY_OFFICE_8_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 52 | CB_FACULTY_OFFICE_8_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 53 | CB_FACULTY_OFFICE_8_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 2.962E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 54 | CB_LAB_1_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LAB_1_F4 ZN | 135.17 | 36.4 | 5.400E-002 | 3.995E-004 | 2.348E-004 | 0.363 | 0.000 | 0.000 | 0.224 | 0.000 |
| 55 | CB_LAB_2_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LAB_2_F4 ZN | 135.17 | 36.4 | 2.064E-002 | 1.527E-004 | 1.204E-004 | 0.139 | 0.000 | 0.000 | 0.224 | 0.000 |
| 56 | CB_LAB_3_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LAB_3_F4 ZN | 135.17 | 36.4 | 2.064E-002 | 1.527E-004 | 1.204E-004 | 0.139 | 0.000 | 0.000 | 0.224 | 0.000 |
| 57 | CB_LAB_4_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LAB_4_F4 ZN | 135.17 | 36.4 | 5.400E-002 | 3.995E-004 | 2.348E-004 | 0.363 | 0.000 | 0.000 | 0.224 | 0.000 |
| 58 | CB_LECTURE_ROOM_1_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LECTURE_ROOM_1_F1 ZN | 270.35 | 189.2 | 7.464E-002 | 2.761E-004 | 5.696E-004 | 0.251 | 0.000 | 0.000 | 0.224 | 0.000 |
| 59 | CB_LECTURE_ROOM_2_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LECTURE_ROOM_2_F1 ZN | 150.50 | 105.3 | 5.985E-002 | 3.976E-004 | 5.696E-004 | 0.361 | 0.000 | 0.000 | 0.224 | 0.000 |
| 60 | CB_LIBRARY_MEDIA_CENTER_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | 29.1 | 7.464E-002 | 2.761E-004 | 5.696E-004 | 0.251 | 0.000 | 0.000 | 0.224 | 0.000 |
| 61 | CB_MAIN_STAIRS_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_MAIN_STAIRS_F1 ZN | 18.58 | 0.0 | 6.879E-003 | 3.702E-004 | 5.696E-004 | 0.336 | 0.000 | 0.000 | 0.224 | 0.000 |
| 62 | CB_MAIN_STAIRS_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_MAIN_STAIRS_F2 ZN | 18.58 | 0.0 | 6.879E-003 | 3.702E-004 | 5.696E-004 | 0.336 | 0.000 | 0.000 | 0.224 | 0.000 |
| 63 | CB_MAIN_STAIRS_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_MAIN_STAIRS_F3 ZN | 18.58 | 0.0 | 6.879E-003 | 3.702E-004 | 5.696E-004 | 0.336 | 0.000 | 0.000 | 0.224 | 0.000 |
| 64 | CB_MAIN_STAIRS_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_MAIN_STAIRS_F4 ZN | 18.58 | 0.0 | 6.879E-003 | 3.702E-004 | 2.244E-004 | 0.336 | 0.000 | 0.000 | 0.224 | 0.000 |
| 65 | CB_OFFICES_ENCLOSED_1_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 66 | CB_OFFICES_ENCLOSED_2_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 67 | CB_OFFICES_ENCLOSED_3_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 68 | CB_OFFICES_ENCLOSED_4_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 69 | CB_OFFICES_ENCLOSED_5_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 70 | CB_OFFICES_ENCLOSED_6_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 71 | CB_OFFICES_ENCLOSED_7_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 72 | CB_OFFICES_ENCLOSED_8_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | 0.7 | 7.567E-003 | 6.170E-004 | 5.696E-004 | 0.561 | 0.000 | 0.000 | 0.224 | 0.000 |
| 73 | CB_PUBLIC_ELEVATORS_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | 0.0 | 5.503E-003 | 4.628E-004 | 5.696E-004 | 0.420 | 0.000 | 0.000 | 0.224 | 0.000 |
| 74 | CB_PUBLIC_ELEVATORS_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_PUBLIC_ELEVATORS_F2 ZN | 11.89 | 0.0 | 5.503E-003 | 4.628E-004 | 5.696E-004 | 0.420 | 0.000 | 0.000 | 0.224 | 0.000 |
| 75 | CB_PUBLIC_ELEVATORS_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_PUBLIC_ELEVATORS_F3 ZN | 11.89 | 0.0 | 5.503E-003 | 4.628E-004 | 5.696E-004 | 0.420 | 0.000 | 0.000 | 0.224 | 0.000 |
| 76 | CB_PUBLIC_ELEVATORS_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_PUBLIC_ELEVATORS_F4 ZN | 11.89 | 0.0 | 5.503E-003 | 4.628E-004 | 2.553E-004 | 0.420 | 0.000 | 0.000 | 0.224 | 0.000 |
| 77 | CB_SECONDARY_STAIRS_1_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_1_F1 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 5.696E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 78 | CB_SECONDARY_STAIRS_1_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_1_F2 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 5.696E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 79 | CB_SECONDARY_STAIRS_1_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_1_F3 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 5.696E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 80 | CB_SECONDARY_STAIRS_1_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_1_F4 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 2.389E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 81 | CB_SECONDARY_STAIRS_2_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_2_F1 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 5.696E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 82 | CB_SECONDARY_STAIRS_2_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_2_F2 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 5.696E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 83 | CB_SECONDARY_STAIRS_2_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_2_F3 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 5.696E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 84 | CB_SECONDARY_STAIRS_2_F4 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_SECONDARY_STAIRS_2_F4 ZN | 12.54 | 0.0 | 5.159E-003 | 4.114E-004 | 2.389E-004 | 0.374 | 0.000 | 0.000 | 0.224 | 0.000 |
| 85 | CB_STORAGE_F1 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_STORAGE_F1 ZN | 75.25 | 0.0 | 2.064E-002 | 2.742E-004 | 5.696E-004 | 0.249 | 0.000 | 0.000 | 0.224 | 0.000 |
| 86 | CB_STUDIO_1_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_STUDIO_1_F2 ZN | 299.61 | 64.5 | 7.464E-002 | 2.491E-004 | 5.696E-004 | 0.226 | 0.000 | 0.000 | 0.224 | 0.000 |
| 87 | CB_STUDIO_1_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_STUDIO_1_F3 ZN | 299.61 | 64.5 | 7.464E-002 | 2.491E-004 | 5.696E-004 | 0.226 | 0.000 | 0.000 | 0.224 | 0.000 |
| 88 | CB_STUDIO_2_F2 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_STUDIO_2_F2 ZN | 299.61 | 64.5 | 7.464E-002 | 2.491E-004 | 5.696E-004 | 0.226 | 0.000 | 0.000 | 0.224 | 0.000 |
| 89 | CB_STUDIO_2_F3 INFILTRATION | COLLEGE INFIL_SCH_PNNL | CB_STUDIO_2_F3 ZN | 299.61 | 64.5 | 7.464E-002 | 2.491E-004 | 5.696E-004 | 0.226 | 0.000 | 0.000 | 0.224 | 0.000 |
| Simple | |
| 1 | Simple |
| Zone Name | Mixing/Mundt/UCSDDV/UCSDCV/UCSDUFI/UCSDUFE/User Defined | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 ZN | Mixing/Well-Stirred |
| 2 | CB_CLASSROOM_1_F2 ZN | Mixing/Well-Stirred |
| 3 | CB_CLASSROOM_1_F3 ZN | Mixing/Well-Stirred |
| 4 | CB_CLASSROOM_1_F4 ZN | Mixing/Well-Stirred |
| 5 | CB_CLASSROOM_2_F2 ZN | Mixing/Well-Stirred |
| 6 | CB_CLASSROOM_2_F3 ZN | Mixing/Well-Stirred |
| 7 | CB_CLASSROOM_2_F4 ZN | Mixing/Well-Stirred |
| 8 | CB_CLASSROOM_3_F2 ZN | Mixing/Well-Stirred |
| 9 | CB_CLASSROOM_3_F3 ZN | Mixing/Well-Stirred |
| 10 | CB_CLASSROOM_3_F4 ZN | Mixing/Well-Stirred |
| 11 | CB_CLASSROOM_4_F2 ZN | Mixing/Well-Stirred |
| 12 | CB_CLASSROOM_4_F3 ZN | Mixing/Well-Stirred |
| 13 | CB_CLASSROOM_4_F4 ZN | Mixing/Well-Stirred |
| 14 | CB_CLASSROOM_5_F2 ZN | Mixing/Well-Stirred |
| 15 | CB_CLASSROOM_5_F3 ZN | Mixing/Well-Stirred |
| 16 | CB_CLASSROOM_5_F4 ZN | Mixing/Well-Stirred |
| 17 | CB_CLASSROOM_6_F2 ZN | Mixing/Well-Stirred |
| 18 | CB_CLASSROOM_6_F3 ZN | Mixing/Well-Stirred |
| 19 | CB_CLASSROOM_6_F4 ZN | Mixing/Well-Stirred |
| 20 | CB_CLASSROOM_7_F2 ZN | Mixing/Well-Stirred |
| 21 | CB_CLASSROOM_7_F3 ZN | Mixing/Well-Stirred |
| 22 | CB_CLASSROOM_8_F2 ZN | Mixing/Well-Stirred |
| 23 | CB_CLASSROOM_8_F3 ZN | Mixing/Well-Stirred |
| 24 | CB_CONFERENCE_ROOM_F1 ZN | Mixing/Well-Stirred |
| 25 | CB_CONFERENCE_ROOM_F2 ZN | Mixing/Well-Stirred |
| 26 | CB_CONFERENCE_ROOM_F3 ZN | Mixing/Well-Stirred |
| 27 | CB_CONFERENCE_ROOM_F4 ZN | Mixing/Well-Stirred |
| 28 | CB_CORRIDOR_1_F3 ZN | Mixing/Well-Stirred |
| 29 | CB_CORRIDOR_2_F3 ZN | Mixing/Well-Stirred |
| 30 | CB_CORRIDOR_F1 ZN | Mixing/Well-Stirred |
| 31 | CB_CORRIDOR_F2 ZN | Mixing/Well-Stirred |
| 32 | CB_CORRIDOR_F4 ZN | Mixing/Well-Stirred |
| 33 | CB_ENTRANCE_LOBBY_F1 ZN | Mixing/Well-Stirred |
| 34 | CB_FACULTY_OFFICE_1_F2 ZN | Mixing/Well-Stirred |
| 35 | CB_FACULTY_OFFICE_1_F3 ZN | Mixing/Well-Stirred |
| 36 | CB_FACULTY_OFFICE_1_F4 ZN | Mixing/Well-Stirred |
| 37 | CB_FACULTY_OFFICE_2_F2 ZN | Mixing/Well-Stirred |
| 38 | CB_FACULTY_OFFICE_2_F3 ZN | Mixing/Well-Stirred |
| 39 | CB_FACULTY_OFFICE_2_F4 ZN | Mixing/Well-Stirred |
| 40 | CB_FACULTY_OFFICE_3_F2 ZN | Mixing/Well-Stirred |
| 41 | CB_FACULTY_OFFICE_3_F3 ZN | Mixing/Well-Stirred |
| 42 | CB_FACULTY_OFFICE_3_F4 ZN | Mixing/Well-Stirred |
| 43 | CB_FACULTY_OFFICE_4_F2 ZN | Mixing/Well-Stirred |
| 44 | CB_FACULTY_OFFICE_4_F3 ZN | Mixing/Well-Stirred |
| 45 | CB_FACULTY_OFFICE_4_F4 ZN | Mixing/Well-Stirred |
| 46 | CB_FACULTY_OFFICE_5_F2 ZN | Mixing/Well-Stirred |
| 47 | CB_FACULTY_OFFICE_5_F3 ZN | Mixing/Well-Stirred |
| 48 | CB_FACULTY_OFFICE_5_F4 ZN | Mixing/Well-Stirred |
| 49 | CB_FACULTY_OFFICE_6_F2 ZN | Mixing/Well-Stirred |
| 50 | CB_FACULTY_OFFICE_6_F3 ZN | Mixing/Well-Stirred |
| 51 | CB_FACULTY_OFFICE_6_F4 ZN | Mixing/Well-Stirred |
| 52 | CB_FACULTY_OFFICE_7_F2 ZN | Mixing/Well-Stirred |
| 53 | CB_FACULTY_OFFICE_7_F3 ZN | Mixing/Well-Stirred |
| 54 | CB_FACULTY_OFFICE_7_F4 ZN | Mixing/Well-Stirred |
| 55 | CB_FACULTY_OFFICE_8_F2 ZN | Mixing/Well-Stirred |
| 56 | CB_FACULTY_OFFICE_8_F3 ZN | Mixing/Well-Stirred |
| 57 | CB_FACULTY_OFFICE_8_F4 ZN | Mixing/Well-Stirred |
| 58 | CB_FACULTY_RESTROOMS_1_F2 ZN | Mixing/Well-Stirred |
| 59 | CB_FACULTY_RESTROOMS_1_F3 ZN | Mixing/Well-Stirred |
| 60 | CB_FACULTY_RESTROOMS_1_F4 ZN | Mixing/Well-Stirred |
| 61 | CB_FACULTY_RESTROOMS_2_F2 ZN | Mixing/Well-Stirred |
| 62 | CB_FACULTY_RESTROOMS_2_F3 ZN | Mixing/Well-Stirred |
| 63 | CB_FACULTY_RESTROOMS_2_F4 ZN | Mixing/Well-Stirred |
| 64 | CB_LAB_1_F4 ZN | Mixing/Well-Stirred |
| 65 | CB_LAB_2_F4 ZN | Mixing/Well-Stirred |
| 66 | CB_LAB_3_F4 ZN | Mixing/Well-Stirred |
| 67 | CB_LAB_4_F4 ZN | Mixing/Well-Stirred |
| 68 | CB_LECTURE_ROOM_1_F1 ZN | Mixing/Well-Stirred |
| 69 | CB_LECTURE_ROOM_2_F1 ZN | Mixing/Well-Stirred |
| 70 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | Mixing/Well-Stirred |
| 71 | CB_MAIN_STAIRS_F1 ZN | Mixing/Well-Stirred |
| 72 | CB_MAIN_STAIRS_F2 ZN | Mixing/Well-Stirred |
| 73 | CB_MAIN_STAIRS_F3 ZN | Mixing/Well-Stirred |
| 74 | CB_MAIN_STAIRS_F4 ZN | Mixing/Well-Stirred |
| 75 | CB_OFFICES_ENCLOSED_1_F1 ZN | Mixing/Well-Stirred |
| 76 | CB_OFFICES_ENCLOSED_2_F1 ZN | Mixing/Well-Stirred |
| 77 | CB_OFFICES_ENCLOSED_3_F1 ZN | Mixing/Well-Stirred |
| 78 | CB_OFFICES_ENCLOSED_4_F1 ZN | Mixing/Well-Stirred |
| 79 | CB_OFFICES_ENCLOSED_5_F1 ZN | Mixing/Well-Stirred |
| 80 | CB_OFFICES_ENCLOSED_6_F1 ZN | Mixing/Well-Stirred |
| 81 | CB_OFFICES_ENCLOSED_7_F1 ZN | Mixing/Well-Stirred |
| 82 | CB_OFFICES_ENCLOSED_8_F1 ZN | Mixing/Well-Stirred |
| 83 | CB_OFFICES_OPEN_F1 ZN | Mixing/Well-Stirred |
| 84 | CB_OFFICES_OPEN_F2 ZN | Mixing/Well-Stirred |
| 85 | CB_OFFICES_OPEN_F3 ZN | Mixing/Well-Stirred |
| 86 | CB_OFFICES_OPEN_F4 ZN | Mixing/Well-Stirred |
| 87 | CB_PUBLIC_ELEVATORS_F1 ZN | Mixing/Well-Stirred |
| 88 | CB_PUBLIC_ELEVATORS_F2 ZN | Mixing/Well-Stirred |
| 89 | CB_PUBLIC_ELEVATORS_F3 ZN | Mixing/Well-Stirred |
| 90 | CB_PUBLIC_ELEVATORS_F4 ZN | Mixing/Well-Stirred |
| 91 | CB_SECONDARY_STAIRS_1_F1 ZN | Mixing/Well-Stirred |
| 92 | CB_SECONDARY_STAIRS_1_F2 ZN | Mixing/Well-Stirred |
| 93 | CB_SECONDARY_STAIRS_1_F3 ZN | Mixing/Well-Stirred |
| 94 | CB_SECONDARY_STAIRS_1_F4 ZN | Mixing/Well-Stirred |
| 95 | CB_SECONDARY_STAIRS_2_F1 ZN | Mixing/Well-Stirred |
| 96 | CB_SECONDARY_STAIRS_2_F2 ZN | Mixing/Well-Stirred |
| 97 | CB_SECONDARY_STAIRS_2_F3 ZN | Mixing/Well-Stirred |
| 98 | CB_SECONDARY_STAIRS_2_F4 ZN | Mixing/Well-Stirred |
| 99 | CB_STAFF_RESTROOMS_1_F1 ZN | Mixing/Well-Stirred |
| 100 | CB_STAFF_RESTROOMS_2_F1 ZN | Mixing/Well-Stirred |
| 101 | CB_STORAGE_F1 ZN | Mixing/Well-Stirred |
| 102 | CB_STUDENTS_RESTROOMS_1_F1 ZN | Mixing/Well-Stirred |
| 103 | CB_STUDENTS_RESTROOMS_1_F2 ZN | Mixing/Well-Stirred |
| 104 | CB_STUDENTS_RESTROOMS_1_F3 ZN | Mixing/Well-Stirred |
| 105 | CB_STUDENTS_RESTROOMS_1_F4 ZN | Mixing/Well-Stirred |
| 106 | CB_STUDENTS_RESTROOMS_2_F1 ZN | Mixing/Well-Stirred |
| 107 | CB_STUDENTS_RESTROOMS_2_F2 ZN | Mixing/Well-Stirred |
| 108 | CB_STUDENTS_RESTROOMS_2_F3 ZN | Mixing/Well-Stirred |
| 109 | CB_STUDENTS_RESTROOMS_2_F4 ZN | Mixing/Well-Stirred |
| 110 | CB_STUDIO_1_F2 ZN | Mixing/Well-Stirred |
| 111 | CB_STUDIO_1_F3 ZN | Mixing/Well-Stirred |
| 112 | CB_STUDIO_2_F2 ZN | Mixing/Well-Stirred |
| 113 | CB_STUDIO_2_F3 ZN | Mixing/Well-Stirred |
| 114 | CB_UTILITY_F1 ZN | Mixing/Well-Stirred |
| 115 | CB_UTILITY_F2 ZN | Mixing/Well-Stirred |
| 116 | CB_UTILITY_F3 ZN | Mixing/Well-Stirred |
| 117 | CB_UTILITY_F4 ZN | Mixing/Well-Stirred |
| No Multizone or Distribution/Multizone with Distribution/Multizone without Distribution/Multizone with Distribution only during Fan Operation | |
| 1 | NoMultizoneOrDistribution |
| Sensible Heat Capacity Multiplier | Moisture Capacity Multiplier | Carbon Dioxide Capacity Multiplier | Generic Contaminant Capacity Multiplier | |
| 1 | 1.000 | 1.000 | 1.000 | 1.000 |
| Value | |
| 1 | 6 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.2500 |
| 2 | Zone CB_CAFE_STUDY_LOUNGE_F1 ZN | 1.2500 |
| 3 | Zone CB_CLASSROOM_1_F2 ZN | 1.2500 |
| 4 | Zone CB_CLASSROOM_1_F3 ZN | 1.2500 |
| 5 | Zone CB_CLASSROOM_1_F4 ZN | 1.2500 |
| 6 | Zone CB_CLASSROOM_2_F2 ZN | 1.2500 |
| 7 | Zone CB_CLASSROOM_2_F3 ZN | 1.2500 |
| 8 | Zone CB_CLASSROOM_2_F4 ZN | 1.2500 |
| 9 | Zone CB_CLASSROOM_3_F2 ZN | 1.2500 |
| 10 | Zone CB_CLASSROOM_3_F3 ZN | 1.2500 |
| 11 | Zone CB_CLASSROOM_3_F4 ZN | 1.2500 |
| 12 | Zone CB_CLASSROOM_4_F2 ZN | 1.2500 |
| 13 | Zone CB_CLASSROOM_4_F3 ZN | 1.2500 |
| 14 | Zone CB_CLASSROOM_4_F4 ZN | 1.2500 |
| 15 | Zone CB_CLASSROOM_5_F2 ZN | 1.2500 |
| 16 | Zone CB_CLASSROOM_5_F3 ZN | 1.2500 |
| 17 | Zone CB_CLASSROOM_5_F4 ZN | 1.2500 |
| 18 | Zone CB_CLASSROOM_6_F2 ZN | 1.2500 |
| 19 | Zone CB_CLASSROOM_6_F3 ZN | 1.2500 |
| 20 | Zone CB_CLASSROOM_6_F4 ZN | 1.2500 |
| 21 | Zone CB_CLASSROOM_7_F2 ZN | 1.2500 |
| 22 | Zone CB_CLASSROOM_7_F3 ZN | 1.2500 |
| 23 | Zone CB_CLASSROOM_8_F2 ZN | 1.2500 |
| 24 | Zone CB_CLASSROOM_8_F3 ZN | 1.2500 |
| 25 | Zone CB_CONFERENCE_ROOM_F1 ZN | 1.2500 |
| 26 | Zone CB_CONFERENCE_ROOM_F2 ZN | 1.2500 |
| 27 | Zone CB_CONFERENCE_ROOM_F3 ZN | 1.2500 |
| 28 | Zone CB_CONFERENCE_ROOM_F4 ZN | 1.2500 |
| 29 | Zone CB_CORRIDOR_1_F3 ZN | 1.2500 |
| 30 | Zone CB_CORRIDOR_2_F3 ZN | 1.2500 |
| 31 | Zone CB_CORRIDOR_F1 ZN | 1.2500 |
| 32 | Zone CB_CORRIDOR_F2 ZN | 1.2500 |
| 33 | Zone CB_CORRIDOR_F4 ZN | 1.2500 |
| 34 | Zone CB_ENTRANCE_LOBBY_F1 ZN | 1.2500 |
| 35 | Zone CB_FACULTY_OFFICE_1_F2 ZN | 1.2500 |
| 36 | Zone CB_FACULTY_OFFICE_1_F3 ZN | 1.2500 |
| 37 | Zone CB_FACULTY_OFFICE_1_F4 ZN | 1.2500 |
| 38 | Zone CB_FACULTY_OFFICE_2_F2 ZN | 1.2500 |
| 39 | Zone CB_FACULTY_OFFICE_2_F3 ZN | 1.2500 |
| 40 | Zone CB_FACULTY_OFFICE_2_F4 ZN | 1.2500 |
| 41 | Zone CB_FACULTY_OFFICE_3_F2 ZN | 1.2500 |
| 42 | Zone CB_FACULTY_OFFICE_3_F3 ZN | 1.2500 |
| 43 | Zone CB_FACULTY_OFFICE_3_F4 ZN | 1.2500 |
| 44 | Zone CB_FACULTY_OFFICE_4_F2 ZN | 1.2500 |
| 45 | Zone CB_FACULTY_OFFICE_4_F3 ZN | 1.2500 |
| 46 | Zone CB_FACULTY_OFFICE_4_F4 ZN | 1.2500 |
| 47 | Zone CB_FACULTY_OFFICE_5_F2 ZN | 1.2500 |
| 48 | Zone CB_FACULTY_OFFICE_5_F3 ZN | 1.2500 |
| 49 | Zone CB_FACULTY_OFFICE_5_F4 ZN | 1.2500 |
| 50 | Zone CB_FACULTY_OFFICE_6_F2 ZN | 1.2500 |
| 51 | Zone CB_FACULTY_OFFICE_6_F3 ZN | 1.2500 |
| 52 | Zone CB_FACULTY_OFFICE_6_F4 ZN | 1.2500 |
| 53 | Zone CB_FACULTY_OFFICE_7_F2 ZN | 1.2500 |
| 54 | Zone CB_FACULTY_OFFICE_7_F3 ZN | 1.2500 |
| 55 | Zone CB_FACULTY_OFFICE_7_F4 ZN | 1.2500 |
| 56 | Zone CB_FACULTY_OFFICE_8_F2 ZN | 1.2500 |
| 57 | Zone CB_FACULTY_OFFICE_8_F3 ZN | 1.2500 |
| 58 | Zone CB_FACULTY_OFFICE_8_F4 ZN | 1.2500 |
| 59 | Zone CB_FACULTY_RESTROOMS_1_F2 ZN | 1.2500 |
| 60 | Zone CB_FACULTY_RESTROOMS_1_F3 ZN | 1.2500 |
| 61 | Zone CB_FACULTY_RESTROOMS_1_F4 ZN | 1.2500 |
| 62 | Zone CB_FACULTY_RESTROOMS_2_F2 ZN | 1.2500 |
| 63 | Zone CB_FACULTY_RESTROOMS_2_F3 ZN | 1.2500 |
| 64 | Zone CB_FACULTY_RESTROOMS_2_F4 ZN | 1.2500 |
| 65 | Zone CB_LAB_1_F4 ZN | 1.2500 |
| 66 | Zone CB_LAB_2_F4 ZN | 1.2500 |
| 67 | Zone CB_LAB_3_F4 ZN | 1.2500 |
| 68 | Zone CB_LAB_4_F4 ZN | 1.2500 |
| 69 | Zone CB_LECTURE_ROOM_1_F1 ZN | 1.2500 |
| 70 | Zone CB_LECTURE_ROOM_2_F1 ZN | 1.2500 |
| 71 | Zone CB_LIBRARY_MEDIA_CENTER_F1 ZN | 1.2500 |
| 72 | Zone CB_MAIN_STAIRS_F1 ZN | 1.2500 |
| 73 | Zone CB_MAIN_STAIRS_F2 ZN | 1.2500 |
| 74 | Zone CB_MAIN_STAIRS_F3 ZN | 1.2500 |
| 75 | Zone CB_MAIN_STAIRS_F4 ZN | 1.2500 |
| 76 | Zone CB_OFFICES_ENCLOSED_1_F1 ZN | 1.2500 |
| 77 | Zone CB_OFFICES_ENCLOSED_2_F1 ZN | 1.2500 |
| 78 | Zone CB_OFFICES_ENCLOSED_3_F1 ZN | 1.2500 |
| 79 | Zone CB_OFFICES_ENCLOSED_4_F1 ZN | 1.2500 |
| 80 | Zone CB_OFFICES_ENCLOSED_5_F1 ZN | 1.2500 |
| 81 | Zone CB_OFFICES_ENCLOSED_6_F1 ZN | 1.2500 |
| 82 | Zone CB_OFFICES_ENCLOSED_7_F1 ZN | 1.2500 |
| 83 | Zone CB_OFFICES_ENCLOSED_8_F1 ZN | 1.2500 |
| 84 | Zone CB_OFFICES_OPEN_F1 ZN | 1.2500 |
| 85 | Zone CB_OFFICES_OPEN_F2 ZN | 1.2500 |
| 86 | Zone CB_OFFICES_OPEN_F3 ZN | 1.2500 |
| 87 | Zone CB_OFFICES_OPEN_F4 ZN | 1.2500 |
| 88 | Zone CB_SECONDARY_STAIRS_1_F1 ZN | 1.2500 |
| 89 | Zone CB_SECONDARY_STAIRS_1_F2 ZN | 1.2500 |
| 90 | Zone CB_SECONDARY_STAIRS_1_F3 ZN | 1.2500 |
| 91 | Zone CB_SECONDARY_STAIRS_1_F4 ZN | 1.2500 |
| 92 | Zone CB_SECONDARY_STAIRS_2_F1 ZN | 1.2500 |
| 93 | Zone CB_SECONDARY_STAIRS_2_F2 ZN | 1.2500 |
| 94 | Zone CB_SECONDARY_STAIRS_2_F3 ZN | 1.2500 |
| 95 | Zone CB_SECONDARY_STAIRS_2_F4 ZN | 1.2500 |
| 96 | Zone CB_STAFF_RESTROOMS_1_F1 ZN | 1.2500 |
| 97 | Zone CB_STAFF_RESTROOMS_2_F1 ZN | 1.2500 |
| 98 | Zone CB_STORAGE_F1 ZN | 1.2500 |
| 99 | Zone CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.2500 |
| 100 | Zone CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.2500 |
| 101 | Zone CB_STUDENTS_RESTROOMS_1_F3 ZN | 1.2500 |
| 102 | Zone CB_STUDENTS_RESTROOMS_1_F4 ZN | 1.2500 |
| 103 | Zone CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.2500 |
| 104 | Zone CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.2500 |
| 105 | Zone CB_STUDENTS_RESTROOMS_2_F3 ZN | 1.2500 |
| 106 | Zone CB_STUDENTS_RESTROOMS_2_F4 ZN | 1.2500 |
| 107 | Zone CB_STUDIO_1_F2 ZN | 1.2500 |
| 108 | Zone CB_STUDIO_1_F3 ZN | 1.2500 |
| 109 | Zone CB_STUDIO_2_F2 ZN | 1.2500 |
| 110 | Zone CB_STUDIO_2_F3 ZN | 1.2500 |
| 111 | Zone CB_UTILITY_F1 ZN | 1.2500 |
| 112 | Zone CB_UTILITY_F2 ZN | 1.2500 |
| 113 | Zone CB_UTILITY_F3 ZN | 1.2500 |
| 114 | Zone CB_UTILITY_F4 ZN | 1.2500 |
| Sizing Factor ID | Value | |
| 1 | Global | 1.1500 |
| 2 | Zone CB_CAFE_STUDY_LOUNGE_F1 ZN | 1.1500 |
| 3 | Zone CB_CLASSROOM_1_F2 ZN | 1.1500 |
| 4 | Zone CB_CLASSROOM_1_F3 ZN | 1.1500 |
| 5 | Zone CB_CLASSROOM_1_F4 ZN | 1.1500 |
| 6 | Zone CB_CLASSROOM_2_F2 ZN | 1.1500 |
| 7 | Zone CB_CLASSROOM_2_F3 ZN | 1.1500 |
| 8 | Zone CB_CLASSROOM_2_F4 ZN | 1.1500 |
| 9 | Zone CB_CLASSROOM_3_F2 ZN | 1.1500 |
| 10 | Zone CB_CLASSROOM_3_F3 ZN | 1.1500 |
| 11 | Zone CB_CLASSROOM_3_F4 ZN | 1.1500 |
| 12 | Zone CB_CLASSROOM_4_F2 ZN | 1.1500 |
| 13 | Zone CB_CLASSROOM_4_F3 ZN | 1.1500 |
| 14 | Zone CB_CLASSROOM_4_F4 ZN | 1.1500 |
| 15 | Zone CB_CLASSROOM_5_F2 ZN | 1.1500 |
| 16 | Zone CB_CLASSROOM_5_F3 ZN | 1.1500 |
| 17 | Zone CB_CLASSROOM_5_F4 ZN | 1.1500 |
| 18 | Zone CB_CLASSROOM_6_F2 ZN | 1.1500 |
| 19 | Zone CB_CLASSROOM_6_F3 ZN | 1.1500 |
| 20 | Zone CB_CLASSROOM_6_F4 ZN | 1.1500 |
| 21 | Zone CB_CLASSROOM_7_F2 ZN | 1.1500 |
| 22 | Zone CB_CLASSROOM_7_F3 ZN | 1.1500 |
| 23 | Zone CB_CLASSROOM_8_F2 ZN | 1.1500 |
| 24 | Zone CB_CLASSROOM_8_F3 ZN | 1.1500 |
| 25 | Zone CB_CONFERENCE_ROOM_F1 ZN | 1.1500 |
| 26 | Zone CB_CONFERENCE_ROOM_F2 ZN | 1.1500 |
| 27 | Zone CB_CONFERENCE_ROOM_F3 ZN | 1.1500 |
| 28 | Zone CB_CONFERENCE_ROOM_F4 ZN | 1.1500 |
| 29 | Zone CB_CORRIDOR_1_F3 ZN | 1.1500 |
| 30 | Zone CB_CORRIDOR_2_F3 ZN | 1.1500 |
| 31 | Zone CB_CORRIDOR_F1 ZN | 1.1500 |
| 32 | Zone CB_CORRIDOR_F2 ZN | 1.1500 |
| 33 | Zone CB_CORRIDOR_F4 ZN | 1.1500 |
| 34 | Zone CB_ENTRANCE_LOBBY_F1 ZN | 1.1500 |
| 35 | Zone CB_FACULTY_OFFICE_1_F2 ZN | 1.1500 |
| 36 | Zone CB_FACULTY_OFFICE_1_F3 ZN | 1.1500 |
| 37 | Zone CB_FACULTY_OFFICE_1_F4 ZN | 1.1500 |
| 38 | Zone CB_FACULTY_OFFICE_2_F2 ZN | 1.1500 |
| 39 | Zone CB_FACULTY_OFFICE_2_F3 ZN | 1.1500 |
| 40 | Zone CB_FACULTY_OFFICE_2_F4 ZN | 1.1500 |
| 41 | Zone CB_FACULTY_OFFICE_3_F2 ZN | 1.1500 |
| 42 | Zone CB_FACULTY_OFFICE_3_F3 ZN | 1.1500 |
| 43 | Zone CB_FACULTY_OFFICE_3_F4 ZN | 1.1500 |
| 44 | Zone CB_FACULTY_OFFICE_4_F2 ZN | 1.1500 |
| 45 | Zone CB_FACULTY_OFFICE_4_F3 ZN | 1.1500 |
| 46 | Zone CB_FACULTY_OFFICE_4_F4 ZN | 1.1500 |
| 47 | Zone CB_FACULTY_OFFICE_5_F2 ZN | 1.1500 |
| 48 | Zone CB_FACULTY_OFFICE_5_F3 ZN | 1.1500 |
| 49 | Zone CB_FACULTY_OFFICE_5_F4 ZN | 1.1500 |
| 50 | Zone CB_FACULTY_OFFICE_6_F2 ZN | 1.1500 |
| 51 | Zone CB_FACULTY_OFFICE_6_F3 ZN | 1.1500 |
| 52 | Zone CB_FACULTY_OFFICE_6_F4 ZN | 1.1500 |
| 53 | Zone CB_FACULTY_OFFICE_7_F2 ZN | 1.1500 |
| 54 | Zone CB_FACULTY_OFFICE_7_F3 ZN | 1.1500 |
| 55 | Zone CB_FACULTY_OFFICE_7_F4 ZN | 1.1500 |
| 56 | Zone CB_FACULTY_OFFICE_8_F2 ZN | 1.1500 |
| 57 | Zone CB_FACULTY_OFFICE_8_F3 ZN | 1.1500 |
| 58 | Zone CB_FACULTY_OFFICE_8_F4 ZN | 1.1500 |
| 59 | Zone CB_FACULTY_RESTROOMS_1_F2 ZN | 1.1500 |
| 60 | Zone CB_FACULTY_RESTROOMS_1_F3 ZN | 1.1500 |
| 61 | Zone CB_FACULTY_RESTROOMS_1_F4 ZN | 1.1500 |
| 62 | Zone CB_FACULTY_RESTROOMS_2_F2 ZN | 1.1500 |
| 63 | Zone CB_FACULTY_RESTROOMS_2_F3 ZN | 1.1500 |
| 64 | Zone CB_FACULTY_RESTROOMS_2_F4 ZN | 1.1500 |
| 65 | Zone CB_LAB_1_F4 ZN | 1.1500 |
| 66 | Zone CB_LAB_2_F4 ZN | 1.1500 |
| 67 | Zone CB_LAB_3_F4 ZN | 1.1500 |
| 68 | Zone CB_LAB_4_F4 ZN | 1.1500 |
| 69 | Zone CB_LECTURE_ROOM_1_F1 ZN | 1.1500 |
| 70 | Zone CB_LECTURE_ROOM_2_F1 ZN | 1.1500 |
| 71 | Zone CB_LIBRARY_MEDIA_CENTER_F1 ZN | 1.1500 |
| 72 | Zone CB_MAIN_STAIRS_F1 ZN | 1.1500 |
| 73 | Zone CB_MAIN_STAIRS_F2 ZN | 1.1500 |
| 74 | Zone CB_MAIN_STAIRS_F3 ZN | 1.1500 |
| 75 | Zone CB_MAIN_STAIRS_F4 ZN | 1.1500 |
| 76 | Zone CB_OFFICES_ENCLOSED_1_F1 ZN | 1.1500 |
| 77 | Zone CB_OFFICES_ENCLOSED_2_F1 ZN | 1.1500 |
| 78 | Zone CB_OFFICES_ENCLOSED_3_F1 ZN | 1.1500 |
| 79 | Zone CB_OFFICES_ENCLOSED_4_F1 ZN | 1.1500 |
| 80 | Zone CB_OFFICES_ENCLOSED_5_F1 ZN | 1.1500 |
| 81 | Zone CB_OFFICES_ENCLOSED_6_F1 ZN | 1.1500 |
| 82 | Zone CB_OFFICES_ENCLOSED_7_F1 ZN | 1.1500 |
| 83 | Zone CB_OFFICES_ENCLOSED_8_F1 ZN | 1.1500 |
| 84 | Zone CB_OFFICES_OPEN_F1 ZN | 1.1500 |
| 85 | Zone CB_OFFICES_OPEN_F2 ZN | 1.1500 |
| 86 | Zone CB_OFFICES_OPEN_F3 ZN | 1.1500 |
| 87 | Zone CB_OFFICES_OPEN_F4 ZN | 1.1500 |
| 88 | Zone CB_SECONDARY_STAIRS_1_F1 ZN | 1.1500 |
| 89 | Zone CB_SECONDARY_STAIRS_1_F2 ZN | 1.1500 |
| 90 | Zone CB_SECONDARY_STAIRS_1_F3 ZN | 1.1500 |
| 91 | Zone CB_SECONDARY_STAIRS_1_F4 ZN | 1.1500 |
| 92 | Zone CB_SECONDARY_STAIRS_2_F1 ZN | 1.1500 |
| 93 | Zone CB_SECONDARY_STAIRS_2_F2 ZN | 1.1500 |
| 94 | Zone CB_SECONDARY_STAIRS_2_F3 ZN | 1.1500 |
| 95 | Zone CB_SECONDARY_STAIRS_2_F4 ZN | 1.1500 |
| 96 | Zone CB_STAFF_RESTROOMS_1_F1 ZN | 1.1500 |
| 97 | Zone CB_STAFF_RESTROOMS_2_F1 ZN | 1.1500 |
| 98 | Zone CB_STORAGE_F1 ZN | 1.1500 |
| 99 | Zone CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.1500 |
| 100 | Zone CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.1500 |
| 101 | Zone CB_STUDENTS_RESTROOMS_1_F3 ZN | 1.1500 |
| 102 | Zone CB_STUDENTS_RESTROOMS_1_F4 ZN | 1.1500 |
| 103 | Zone CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.1500 |
| 104 | Zone CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.1500 |
| 105 | Zone CB_STUDENTS_RESTROOMS_2_F3 ZN | 1.1500 |
| 106 | Zone CB_STUDENTS_RESTROOMS_2_F4 ZN | 1.1500 |
| 107 | Zone CB_STUDIO_1_F2 ZN | 1.1500 |
| 108 | Zone CB_STUDIO_1_F3 ZN | 1.1500 |
| 109 | Zone CB_STUDIO_2_F2 ZN | 1.1500 |
| 110 | Zone CB_STUDIO_2_F3 ZN | 1.1500 |
| 111 | Zone CB_UTILITY_F1 ZN | 1.1500 |
| 112 | Zone CB_UTILITY_F2 ZN | 1.1500 |
| 113 | Zone CB_UTILITY_F3 ZN | 1.1500 |
| 114 | Zone CB_UTILITY_F4 ZN | 1.1500 |
| Sky Type | MonthAndDay | Daylighting Control Name | Enclosure Name | Window Name | Reference Point | Daylight Factor | |
| 1 | Clear Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 9.7631E-003 |
| 2 | Clear Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 5.2264E-003 |
| 3 | Clear Turbid Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 8.2957E-003 |
| 4 | Clear Turbid Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 4.3264E-003 |
| 5 | Intermediate Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 6.4316E-003 |
| 6 | Intermediate Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 2.7637E-003 |
| 7 | Overcast Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 1.1909E-002 |
| 8 | Overcast Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 58 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 4.7269E-003 |
| 9 | Clear Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 9.4739E-004 |
| 10 | Clear Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 9.7814E-004 |
| 11 | Clear Turbid Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 7.8870E-004 |
| 12 | Clear Turbid Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 8.1135E-004 |
| 13 | Intermediate Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 5.1116E-004 |
| 14 | Intermediate Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 5.1717E-004 |
| 15 | Overcast Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | 8.1527E-004 |
| 16 | Overcast Sky | 08/21 | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | CB_CAFE_STUDY_LOUNGE_F1 | SUB SURFACE 12 | CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | 8.3314E-004 |
| 17 | Clear Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 9.2840E-003 |
| 18 | Clear Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 4.4897E-003 |
| 19 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 7.9011E-003 |
| 20 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 3.7308E-003 |
| 21 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 6.2061E-003 |
| 22 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 2.4494E-003 |
| 23 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 1.1561E-002 |
| 24 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 23 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 4.2357E-003 |
| 25 | Clear Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 6.1166E-003 |
| 26 | Clear Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 6.6059E-003 |
| 27 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 5.6361E-003 |
| 28 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 6.0508E-003 |
| 29 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 4.1028E-003 |
| 30 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 4.3790E-003 |
| 31 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | 3.9242E-003 |
| 32 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F2 | SUB SURFACE 40 | CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | 4.2898E-003 |
| 33 | Clear Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 6.1354E-003 |
| 34 | Clear Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 6.6231E-003 |
| 35 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 5.6534E-003 |
| 36 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 6.0667E-003 |
| 37 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 4.1159E-003 |
| 38 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 4.3910E-003 |
| 39 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 3.9374E-003 |
| 40 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 100 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 4.3018E-003 |
| 41 | Clear Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 9.3035E-003 |
| 42 | Clear Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 4.5106E-003 |
| 43 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 7.9178E-003 |
| 44 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 3.7484E-003 |
| 45 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 6.2180E-003 |
| 46 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 2.4614E-003 |
| 47 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | 1.1579E-002 |
| 48 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F3 | SUB SURFACE 97 | CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | 4.2540E-003 |
| 49 | Clear Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 33 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 9.5470E-003 |
| 50 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 33 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 8.1206E-003 |
| 51 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 33 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 6.3382E-003 |
| 52 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 33 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 1.1760E-002 |
| 53 | Clear Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 10 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 2.7017E-003 |
| 54 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 10 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 2.2318E-003 |
| 55 | Intermediate Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 10 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 1.4049E-003 |
| 56 | Overcast Sky | 08/21 | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_1_F4 | SUB SURFACE 10 | CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | 2.3899E-003 |
| 57 | Clear Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 1 | 1.0036E-002 |
| 58 | Clear Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 2 | 5.3220E-003 |
| 59 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 1 | 8.5498E-003 |
| 60 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 2 | 4.4397E-003 |
| 61 | Intermediate Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 1 | 6.6782E-003 |
| 62 | Intermediate Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 2 | 2.9431E-003 |
| 63 | Overcast Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 1 | 1.2252E-002 |
| 64 | Overcast Sky | 08/21 | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_2_F4 | SUB SURFACE 34 | CB_CLASSROOM_2_F4 DAYLT SENSOR 2 | 4.9694E-003 |
| 65 | Clear Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 1 | 1.0033E-002 |
| 66 | Clear Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 2 | 5.3187E-003 |
| 67 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 1 | 8.5472E-003 |
| 68 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 2 | 4.4368E-003 |
| 69 | Intermediate Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 1 | 6.6763E-003 |
| 70 | Intermediate Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 2 | 2.9411E-003 |
| 71 | Overcast Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 1 | 1.2249E-002 |
| 72 | Overcast Sky | 08/21 | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_3_F4 | SUB SURFACE 35 | CB_CLASSROOM_3_F4 DAYLT SENSOR 2 | 4.9664E-003 |
| 73 | Clear Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 1 | 1.0032E-002 |
| 74 | Clear Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 2 | 5.3182E-003 |
| 75 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 1 | 8.5469E-003 |
| 76 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 2 | 4.4364E-003 |
| 77 | Intermediate Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 1 | 6.6761E-003 |
| 78 | Intermediate Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 2 | 2.9408E-003 |
| 79 | Overcast Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 1 | 1.2249E-002 |
| 80 | Overcast Sky | 08/21 | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_4_F4 | SUB SURFACE 36 | CB_CLASSROOM_4_F4 DAYLT SENSOR 2 | 4.9660E-003 |
| 81 | Clear Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 1 | 1.0036E-002 |
| 82 | Clear Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 2 | 5.3228E-003 |
| 83 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 1 | 8.5504E-003 |
| 84 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 2 | 4.4403E-003 |
| 85 | Intermediate Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 1 | 6.6786E-003 |
| 86 | Intermediate Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 2 | 2.9436E-003 |
| 87 | Overcast Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 1 | 1.2252E-002 |
| 88 | Overcast Sky | 08/21 | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_5_F4 | SUB SURFACE 37 | CB_CLASSROOM_5_F4 DAYLT SENSOR 2 | 4.9700E-003 |
| 89 | Clear Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 9.5496E-003 |
| 90 | Clear Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 4.8362E-003 |
| 91 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 8.1229E-003 |
| 92 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 4.0130E-003 |
| 93 | Intermediate Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 6.3399E-003 |
| 94 | Intermediate Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 2.6050E-003 |
| 95 | Overcast Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 1.1763E-002 |
| 96 | Overcast Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 38 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 4.4808E-003 |
| 97 | Clear Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 3.9195E-003 |
| 98 | Clear Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 4.1989E-003 |
| 99 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 3.5935E-003 |
| 100 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 3.8283E-003 |
| 101 | Intermediate Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 2.5718E-003 |
| 102 | Intermediate Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 2.7207E-003 |
| 103 | Overcast Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | 2.3920E-003 |
| 104 | Overcast Sky | 08/21 | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_6_F4 | SUB SURFACE 66 | CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | 2.5791E-003 |
| 105 | Clear Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 9.2851E-003 |
| 106 | Clear Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 4.4909E-003 |
| 107 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 7.9020E-003 |
| 108 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 3.7318E-003 |
| 109 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 6.2068E-003 |
| 110 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 2.4501E-003 |
| 111 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 1.1562E-002 |
| 112 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 13 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 4.2368E-003 |
| 113 | Clear Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 4.1153E-003 |
| 114 | Clear Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 4.5027E-003 |
| 115 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 3.4029E-003 |
| 116 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 3.7027E-003 |
| 117 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 2.1972E-003 |
| 118 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 2.3358E-003 |
| 119 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | 3.9379E-003 |
| 120 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F2 | SUB SURFACE 9 | CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | 4.3035E-003 |
| 121 | Clear Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 9.3036E-003 |
| 122 | Clear Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 4.5107E-003 |
| 123 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 7.9178E-003 |
| 124 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 3.7485E-003 |
| 125 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 6.2180E-003 |
| 126 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 2.4615E-003 |
| 127 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 1.1579E-002 |
| 128 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 70 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 4.2541E-003 |
| 129 | Clear Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 4.1161E-003 |
| 130 | Clear Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 4.5022E-003 |
| 131 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 3.4037E-003 |
| 132 | Clear Turbid Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 3.7024E-003 |
| 133 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 2.1976E-003 |
| 134 | Intermediate Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 2.3357E-003 |
| 135 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | 3.9374E-003 |
| 136 | Overcast Sky | 08/21 | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | CB_CLASSROOM_8_F3 | SUB SURFACE 67 | CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | 4.3013E-003 |
| 137 | Clear Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 1 | 1.7340E-003 |
| 138 | Clear Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 2 | 1.8122E-003 |
| 139 | Clear Turbid Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 1 | 1.5636E-003 |
| 140 | Clear Turbid Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 2 | 1.6255E-003 |
| 141 | Intermediate Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 1 | 1.1208E-003 |
| 142 | Intermediate Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 2 | 1.1539E-003 |
| 143 | Overcast Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 1 | 1.1021E-003 |
| 144 | Overcast Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 56 | CB_LAB_1_F4 DAYLT SENSOR 2 | 1.1507E-003 |
| 145 | Clear Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 1 | 8.9742E-003 |
| 146 | Clear Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 2 | 4.7808E-003 |
| 147 | Clear Turbid Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 1 | 7.4906E-003 |
| 148 | Clear Turbid Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 2 | 3.8984E-003 |
| 149 | Intermediate Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 1 | 5.6221E-003 |
| 150 | Intermediate Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 2 | 2.3667E-003 |
| 151 | Overcast Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 1 | 1.1699E-002 |
| 152 | Overcast Sky | 08/21 | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_1_F4 | SUB SURFACE 2 | CB_LAB_1_F4 DAYLT SENSOR 2 | 4.4994E-003 |
| 153 | Clear Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 1 | 1.3133E-002 |
| 154 | Clear Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 2 | 5.8661E-003 |
| 155 | Clear Turbid Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 1 | 1.2241E-002 |
| 156 | Clear Turbid Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 2 | 5.2255E-003 |
| 157 | Intermediate Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 1 | 1.0009E-002 |
| 158 | Intermediate Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 2 | 3.7029E-003 |
| 159 | Overcast Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 1 | 1.1437E-002 |
| 160 | Overcast Sky | 08/21 | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_2_F4 | SUB SURFACE 55 | CB_LAB_2_F4 DAYLT SENSOR 2 | 4.1551E-003 |
| 161 | Clear Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 1 | 1.3133E-002 |
| 162 | Clear Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 2 | 5.8663E-003 |
| 163 | Clear Turbid Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 1 | 1.2242E-002 |
| 164 | Clear Turbid Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 2 | 5.2257E-003 |
| 165 | Intermediate Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 1 | 1.0009E-002 |
| 166 | Intermediate Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 2 | 3.7030E-003 |
| 167 | Overcast Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 1 | 1.1438E-002 |
| 168 | Overcast Sky | 08/21 | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_3_F4 | SUB SURFACE 54 | CB_LAB_3_F4 DAYLT SENSOR 2 | 4.1552E-003 |
| 169 | Clear Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.6479E-003 |
| 170 | Clear Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 2 | 1.7641E-003 |
| 171 | Clear Turbid Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.4734E-003 |
| 172 | Clear Turbid Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 2 | 1.5761E-003 |
| 173 | Intermediate Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.0571E-003 |
| 174 | Intermediate Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 2 | 1.1193E-003 |
| 175 | Overcast Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.0957E-003 |
| 176 | Overcast Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 53 | CB_LAB_4_F4 DAYLT SENSOR 2 | 1.1441E-003 |
| 177 | Clear Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.4984E-002 |
| 178 | Clear Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 2 | 6.9565E-003 |
| 179 | Clear Turbid Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.4284E-002 |
| 180 | Clear Turbid Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 2 | 6.3146E-003 |
| 181 | Intermediate Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.1564E-002 |
| 182 | Intermediate Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 2 | 4.4732E-003 |
| 183 | Overcast Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 1 | 1.1704E-002 |
| 184 | Overcast Sky | 08/21 | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | CB_LAB_4_F4 | SUB SURFACE 72 | CB_LAB_4_F4 DAYLT SENSOR 2 | 4.5042E-003 |
| 185 | Clear Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.4298E-002 |
| 186 | Clear Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 6.2704E-003 |
| 187 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.3627E-002 |
| 188 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 5.6574E-003 |
| 189 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.1019E-002 |
| 190 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 3.9286E-003 |
| 191 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.1199E-002 |
| 192 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 74 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 3.9990E-003 |
| 193 | Clear Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.9249E-003 |
| 194 | Clear Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 2.0849E-003 |
| 195 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.7198E-003 |
| 196 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 1.8575E-003 |
| 197 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.2309E-003 |
| 198 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 1.3103E-003 |
| 199 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | 1.2814E-003 |
| 200 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_1_F1 | SUB SURFACE 77 | CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | 1.3522E-003 |
| 201 | Clear Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 1.4732E-003 |
| 202 | Clear Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 1.5056E-003 |
| 203 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 1.3640E-003 |
| 204 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 1.3900E-003 |
| 205 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 1.0118E-003 |
| 206 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 1.0262E-003 |
| 207 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 9.1091E-004 |
| 208 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 68 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 9.2871E-004 |
| 209 | Clear Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 9.9773E-003 |
| 210 | Clear Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 5.4407E-003 |
| 211 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 8.4832E-003 |
| 212 | Clear Turbid Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 4.5140E-003 |
| 213 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 6.5792E-003 |
| 214 | Intermediate Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 2.9114E-003 |
| 215 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | 1.2124E-002 |
| 216 | Overcast Sky | 08/21 | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | CB_LECTURE_ROOM_2_F1 | SUB SURFACE 65 | CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | 4.9423E-003 |
| 217 | Clear Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 8.4916E-003 |
| 218 | Clear Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 4.2982E-003 |
| 219 | Clear Turbid Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 7.0675E-003 |
| 220 | Clear Turbid Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 3.4754E-003 |
| 221 | Intermediate Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 5.2867E-003 |
| 222 | Intermediate Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 2.0313E-003 |
| 223 | Overcast Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 1.1196E-002 |
| 224 | Overcast Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 4 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 3.9958E-003 |
| 225 | Clear Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 2.0299E-003 |
| 226 | Clear Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 2.1666E-003 |
| 227 | Clear Turbid Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 1.8319E-003 |
| 228 | Clear Turbid Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 1.9445E-003 |
| 229 | Intermediate Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 1.3123E-003 |
| 230 | Intermediate Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 1.3739E-003 |
| 231 | Overcast Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | 1.2838E-003 |
| 232 | Overcast Sky | 08/21 | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | CB_LIBRARY_MEDIA_CENTER_F1 | SUB SURFACE 104 | CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | 1.3551E-003 |
| 233 | Clear Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 8.3222E-003 |
| 234 | Clear Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 4.1288E-003 |
| 235 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 6.9243E-003 |
| 236 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 3.3322E-003 |
| 237 | Intermediate Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 5.1821E-003 |
| 238 | Intermediate Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 1.9267E-003 |
| 239 | Overcast Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 1.1017E-002 |
| 240 | Overcast Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 1 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 3.8171E-003 |
| 241 | Clear Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 1.7284E-003 |
| 242 | Clear Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 1.8659E-003 |
| 243 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 1.5511E-003 |
| 244 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 1.6645E-003 |
| 245 | Intermediate Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 1.0885E-003 |
| 246 | Intermediate Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 1.1505E-003 |
| 247 | Overcast Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 1 | 1.0570E-003 |
| 248 | Overcast Sky | 08/21 | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F2 | SUB SURFACE 52 | CB_STUDIO_1_F2 DAYLT SENSOR 2 | 1.1288E-003 |
| 249 | Clear Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.6276E-003 |
| 250 | Clear Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 1.7876E-003 |
| 251 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.4427E-003 |
| 252 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 1.5804E-003 |
| 253 | Intermediate Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.0095E-003 |
| 254 | Intermediate Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 1.0889E-003 |
| 255 | Overcast Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.0572E-003 |
| 256 | Overcast Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 3 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 1.1281E-003 |
| 257 | Clear Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.4039E-002 |
| 258 | Clear Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 6.0115E-003 |
| 259 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.3381E-002 |
| 260 | Clear Turbid Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 5.4113E-003 |
| 261 | Intermediate Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.0823E-002 |
| 262 | Intermediate Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 3.7320E-003 |
| 263 | Overcast Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 1 | 1.1019E-002 |
| 264 | Overcast Sky | 08/21 | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_1_F3 | SUB SURFACE 103 | CB_STUDIO_1_F3 DAYLT SENSOR 2 | 3.8198E-003 |
| 265 | Clear Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.6242E-003 |
| 266 | Clear Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 1.7848E-003 |
| 267 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.4397E-003 |
| 268 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 1.5779E-003 |
| 269 | Intermediate Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.0075E-003 |
| 270 | Intermediate Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 1.0872E-003 |
| 271 | Overcast Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.0553E-003 |
| 272 | Overcast Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 43 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 1.1265E-003 |
| 273 | Clear Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.4038E-002 |
| 274 | Clear Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 6.0106E-003 |
| 275 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.3380E-002 |
| 276 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 5.4104E-003 |
| 277 | Intermediate Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.0822E-002 |
| 278 | Intermediate Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 3.7313E-003 |
| 279 | Overcast Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 1 | 1.1019E-002 |
| 280 | Overcast Sky | 08/21 | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F2 | SUB SURFACE 42 | CB_STUDIO_2_F2 DAYLT SENSOR 2 | 3.8192E-003 |
| 281 | Clear Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 8.3237E-003 |
| 282 | Clear Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 4.1307E-003 |
| 283 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 6.9256E-003 |
| 284 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 3.3338E-003 |
| 285 | Intermediate Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 5.1830E-003 |
| 286 | Intermediate Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 1.9278E-003 |
| 287 | Overcast Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 1.1018E-002 |
| 288 | Overcast Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 63 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 3.8187E-003 |
| 289 | Clear Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 1.7254E-003 |
| 290 | Clear Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 1.8608E-003 |
| 291 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 1.5486E-003 |
| 292 | Clear Turbid Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 1.6601E-003 |
| 293 | Intermediate Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 1.0873E-003 |
| 294 | Intermediate Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 1.1482E-003 |
| 295 | Overcast Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 1 | 1.0560E-003 |
| 296 | Overcast Sky | 08/21 | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | CB_STUDIO_2_F3 | SUB SURFACE 61 | CB_STUDIO_2_F3 DAYLT SENSOR 2 | 1.1265E-003 |
| Zone Name | Load Type | Calc Des Load {W} | User Des Load {W} | Calc Des Air Flow Rate {m3/s} | User Des Air Flow Rate {m3/s} | Design Day Name | Date/Time of Peak | Temperature at Peak {C} | Humidity Ratio at Peak {kgWater/kgDryAir} | Floor Area {m2} | # Occupants | Calc Outdoor Air Flow Rate {m3/s} | Calc DOAS Heat Addition Rate {W} | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 ZN | Cooling | 16697.11461 | 19201.68180 | 1.22538 | 1.40918 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 33.90000 | 1.65364E-002 | 179.76738 | 48.37500 | 0.00000 | 0.00000 |
| 2 | CB_CLASSROOM_1_F2 ZN | Cooling | 3324.27161 | 3822.91235 | 0.24399 | 0.28058 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 30.89800 | 1.65307E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 3 | CB_CLASSROOM_1_F2 ZN | Heating | 1303.93313 | 1629.91641 | 5.42876E-002 | 6.78595E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 4 | CB_CLASSROOM_1_F3 ZN | Cooling | 3325.91794 | 3824.80563 | 0.24411 | 0.28072 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:10:00 | 31.09550 | 1.65311E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 5 | CB_CLASSROOM_1_F3 ZN | Heating | 1387.06796 | 1733.83495 | 5.76701E-002 | 7.20876E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 6 | CB_CLASSROOM_1_F4 ZN | Cooling | 5063.46487 | 5822.98460 | 0.37163 | 0.42737 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 7 | CB_CLASSROOM_1_F4 ZN | Heating | 1966.36535 | 2457.95669 | 8.13106E-002 | 0.10164 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 8 | CB_CLASSROOM_2_F2 ZN | Cooling | 2500.39611 | 2875.45552 | 0.18351 | 0.21104 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 9 | CB_CLASSROOM_2_F2 ZN | Heating | 538.22357 | 672.77946 | 2.27158E-002 | 2.83947E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 10 | CB_CLASSROOM_2_F3 ZN | Cooling | 2499.42382 | 2874.33740 | 0.18344 | 0.21096 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 11 | CB_CLASSROOM_2_F3 ZN | Heating | 582.24057 | 727.80071 | 2.45533E-002 | 3.06916E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 12 | CB_CLASSROOM_2_F4 ZN | Cooling | 3717.28091 | 4274.87305 | 0.27282 | 0.31375 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 13 | CB_CLASSROOM_2_F4 ZN | Heating | 1070.69816 | 1338.37270 | 4.48060E-002 | 5.60075E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 14 | CB_CLASSROOM_3_F2 ZN | Cooling | 2495.02170 | 2869.27496 | 0.18312 | 0.21059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 15 | CB_CLASSROOM_3_F2 ZN | Heating | 473.82753 | 592.28441 | 2.00468E-002 | 2.50585E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 16 | CB_CLASSROOM_3_F3 ZN | Cooling | 2439.31233 | 2805.20918 | 0.17903 | 0.20588 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 17 | CB_CLASSROOM_3_F3 ZN | Heating | 502.63723 | 628.29653 | 2.12473E-002 | 2.65591E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 18 | CB_CLASSROOM_3_F4 ZN | Cooling | 3619.41627 | 4162.32871 | 0.26564 | 0.30549 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 19 | CB_CLASSROOM_3_F4 ZN | Heating | 1017.16367 | 1271.45458 | 4.26164E-002 | 5.32705E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 20 | CB_CLASSROOM_4_F2 ZN | Cooling | 2784.82155 | 3202.54479 | 0.20438 | 0.23504 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 21 | CB_CLASSROOM_4_F2 ZN | Heating | 482.08250 | 602.60312 | 2.04023E-002 | 2.55029E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 22 | CB_CLASSROOM_4_F3 ZN | Cooling | 2459.25455 | 2828.14274 | 0.18049 | 0.20757 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 23 | CB_CLASSROOM_4_F3 ZN | Heating | 524.80385 | 656.00482 | 2.21832E-002 | 2.77290E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 24 | CB_CLASSROOM_4_F4 ZN | Cooling | 3697.59614 | 4252.23556 | 0.27138 | 0.31209 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 25 | CB_CLASSROOM_4_F4 ZN | Heating | 1091.80940 | 1364.76175 | 4.57086E-002 | 5.71357E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 26 | CB_CLASSROOM_5_F2 ZN | Cooling | 2339.83284 | 2690.80776 | 0.17173 | 0.19749 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 27 | CB_CLASSROOM_5_F2 ZN | Heating | 387.92634 | 484.90793 | 1.64594E-002 | 2.05743E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 28 | CB_CLASSROOM_5_F3 ZN | Cooling | 2349.39509 | 2701.80436 | 0.17243 | 0.19830 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 29 | CB_CLASSROOM_5_F3 ZN | Heating | 462.17593 | 577.71991 | 1.95615E-002 | 2.44518E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 30 | CB_CLASSROOM_5_F4 ZN | Cooling | 3712.55631 | 4269.43975 | 0.27248 | 0.31335 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 31 | CB_CLASSROOM_5_F4 ZN | Heating | 1082.59738 | 1353.24672 | 4.52921E-002 | 5.66151E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 32 | CB_CLASSROOM_6_F2 ZN | Cooling | 2512.93612 | 2889.87654 | 0.18443 | 0.21210 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 33 | CB_CLASSROOM_6_F2 ZN | Heating | 213.32324 | 266.65405 | 9.12799E-003 | 1.14100E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 34 | CB_CLASSROOM_6_F3 ZN | Cooling | 2433.78390 | 2798.85149 | 0.17862 | 0.20542 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 35 | CB_CLASSROOM_6_F3 ZN | Heating | 466.17490 | 582.71863 | 1.97287E-002 | 2.46609E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 36 | CB_CLASSROOM_6_F4 ZN | Cooling | 4512.65235 | 5189.55020 | 0.33117 | 0.38085 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 33.50500 | 1.65356E-002 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 37 | CB_CLASSROOM_6_F4 ZN | Heating | 1992.34470 | 2490.43087 | 8.23510E-002 | 0.10294 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 52.65000 | 0.00000 | 0.00000 |
| 38 | CB_CLASSROOM_7_F2 ZN | Cooling | 2637.09610 | 3032.66051 | 0.19354 | 0.22258 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 39 | CB_CLASSROOM_7_F2 ZN | Heating | 166.49011 | 208.11264 | 7.13825E-003 | 8.92281E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 40 | CB_CLASSROOM_7_F3 ZN | Cooling | 2516.31057 | 2893.75716 | 0.18468 | 0.21238 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 41 | CB_CLASSROOM_7_F3 ZN | Heating | 537.18771 | 671.48464 | 2.26849E-002 | 2.83561E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 42 | CB_CLASSROOM_8_F2 ZN | Cooling | 3772.17708 | 4338.00365 | 0.27685 | 0.31838 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 43 | CB_CLASSROOM_8_F2 ZN | Heating | 889.98557 | 1112.48196 | 3.74678E-002 | 4.68348E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 44 | CB_CLASSROOM_8_F3 ZN | Cooling | 3660.19165 | 4209.22039 | 0.26864 | 0.30893 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 45 | CB_CLASSROOM_8_F3 ZN | Heating | 1327.97758 | 1659.97198 | 5.52826E-002 | 6.91033E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 56.43860 | 39.48750 | 0.00000 | 0.00000 |
| 46 | CB_CONFERENCE_ROOM_F1 ZN | Cooling | 2329.14543 | 2678.51724 | 0.17100 | 0.19665 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 45.98700 | 24.75000 | 8.17649E-002 | 0.00000 |
| 47 | CB_CONFERENCE_ROOM_F1 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 8.17649E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 45.98700 | 24.75000 | 8.17649E-002 | 0.00000 | |
| 48 | CB_CONFERENCE_ROOM_F2 ZN | Cooling | 1570.02398 | 1805.52758 | 0.11527 | 0.13256 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 30.65800 | 16.50000 | 5.45099E-002 | 0.00000 |
| 49 | CB_CONFERENCE_ROOM_F2 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 5.45099E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 30.65800 | 16.50000 | 5.45099E-002 | 0.00000 | |
| 50 | CB_CONFERENCE_ROOM_F3 ZN | Cooling | 1567.11506 | 1802.18232 | 0.11505 | 0.13231 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 30.65800 | 16.50000 | 5.45099E-002 | 0.00000 |
| 51 | CB_CONFERENCE_ROOM_F3 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 5.45099E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 30.65800 | 16.50000 | 5.45099E-002 | 0.00000 | |
| 52 | CB_CONFERENCE_ROOM_F4 ZN | Cooling | 1791.41688 | 2060.12942 | 0.13152 | 0.15124 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 30.65800 | 16.50000 | 5.45099E-002 | 0.00000 |
| 53 | CB_CONFERENCE_ROOM_F4 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 5.45099E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 30.65800 | 16.50000 | 5.45099E-002 | 0.00000 | |
| 54 | CB_CORRIDOR_1_F3 ZN | Cooling | 561.84059 | 646.11668 | 4.12168E-002 | 4.73993E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 33.50500 | 1.65356E-002 | 31.58703 | 0.00000 | 3.20924E-003 | 0.00000 |
| 55 | CB_CORRIDOR_1_F3 ZN | Heating | 314.40886 | 393.01107 | 1.33166E-002 | 1.66457E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 31.58703 | 0.00000 | 3.20924E-003 | 0.00000 |
| 56 | CB_CORRIDOR_2_F3 ZN | Cooling | 782.43911 | 899.80498 | 5.73992E-002 | 6.60091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 61.31601 | 0.00000 | 6.22971E-003 | 0.00000 |
| 57 | CB_CORRIDOR_2_F3 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 6.22971E-003 | 00:10:00 | 27.34300 | 1.65240E-002 | 61.31601 | 0.00000 | 6.22971E-003 | 0.00000 | |
| 58 | CB_CORRIDOR_F1 ZN | Cooling | 4153.67728 | 4776.72888 | 0.30471 | 0.35042 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 122.16750 | 0.00000 | 1.24122E-002 | 0.00000 |
| 59 | CB_CORRIDOR_F1 ZN | Heating | 8.78338 | 10.97923 | 3.79091E-004 | 1.24122E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 06:20:00 | 4.60000 | 5.25715E-003 | 122.16750 | 0.00000 | 1.24122E-002 | 0.00000 |
| 60 | CB_CORRIDOR_F2 ZN | Cooling | 1607.41048 | 1848.52205 | 0.11792 | 0.13561 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 92.90304 | 0.00000 | 9.43895E-003 | 0.00000 |
| 61 | CB_CORRIDOR_F2 ZN | Heating | 45.96355 | 57.45443 | 1.97904E-003 | 9.43895E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 92.90304 | 0.00000 | 9.43895E-003 | 0.00000 |
| 62 | CB_CORRIDOR_F4 ZN | Cooling | 3269.65130 | 3760.09899 | 0.23986 | 0.27584 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 151.43196 | 0.00000 | 1.53855E-002 | 0.00000 |
| 63 | CB_CORRIDOR_F4 ZN | Heating | 888.93342 | 1111.16677 | 3.77966E-002 | 4.72457E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 151.43196 | 0.00000 | 1.53855E-002 | 0.00000 |
| 64 | CB_ENTRANCE_LOBBY_F1 ZN | Cooling | 1538.61421 | 1769.40634 | 0.11289 | 0.12983 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 33.50500 | 1.65356E-002 | 75.25146 | 8.10000 | 0.00000 | 0.00000 |
| 65 | CB_ENTRANCE_LOBBY_F1 ZN | Heating | 520.39290 | 650.49112 | 2.20887E-002 | 2.76109E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 8.10000 | 0.00000 | 0.00000 |
| 66 | CB_FACULTY_OFFICE_1_F2 ZN | Cooling | 595.14840 | 684.42066 | 4.36638E-002 | 5.02134E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 67 | CB_FACULTY_OFFICE_1_F2 ZN | Heating | 215.98086 | 269.97607 | 9.11657E-003 | 1.13957E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 68 | CB_FACULTY_OFFICE_1_F3 ZN | Cooling | 599.93200 | 689.92180 | 4.40149E-002 | 5.06172E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 69 | CB_FACULTY_OFFICE_1_F3 ZN | Heating | 232.28775 | 290.35969 | 9.79395E-003 | 1.22424E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 70 | CB_FACULTY_OFFICE_1_F4 ZN | Cooling | 716.37433 | 823.83048 | 5.25579E-002 | 6.04415E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 71 | CB_FACULTY_OFFICE_1_F4 ZN | Heating | 267.34159 | 334.17699 | 1.12364E-002 | 1.40456E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 72 | CB_FACULTY_OFFICE_2_F2 ZN | Cooling | 596.68529 | 686.18809 | 4.37765E-002 | 5.03430E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 73 | CB_FACULTY_OFFICE_2_F2 ZN | Heating | 223.13345 | 278.91682 | 9.41038E-003 | 1.17630E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 74 | CB_FACULTY_OFFICE_2_F3 ZN | Cooling | 600.12517 | 690.14395 | 4.40291E-002 | 5.06335E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 75 | CB_FACULTY_OFFICE_2_F3 ZN | Heating | 245.58741 | 306.98426 | 1.03416E-002 | 1.29270E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 76 | CB_FACULTY_OFFICE_2_F4 ZN | Cooling | 699.05037 | 803.90792 | 5.12869E-002 | 5.89799E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 77 | CB_FACULTY_OFFICE_2_F4 ZN | Heating | 330.18116 | 412.72645 | 1.37980E-002 | 1.72475E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 78 | CB_FACULTY_OFFICE_3_F2 ZN | Cooling | 596.10770 | 685.52386 | 4.37342E-002 | 5.02943E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 79 | CB_FACULTY_OFFICE_3_F2 ZN | Heating | 223.54588 | 279.43235 | 9.42702E-003 | 1.17838E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 80 | CB_FACULTY_OFFICE_3_F3 ZN | Cooling | 599.73115 | 689.69082 | 4.40002E-002 | 5.06002E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 81 | CB_FACULTY_OFFICE_3_F3 ZN | Heating | 247.18956 | 308.98695 | 1.04073E-002 | 1.30091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 82 | CB_FACULTY_OFFICE_3_F4 ZN | Cooling | 697.51245 | 802.13932 | 5.11741E-002 | 5.88502E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 83 | CB_FACULTY_OFFICE_3_F4 ZN | Heating | 337.29542 | 421.61928 | 1.40839E-002 | 1.76049E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 84 | CB_FACULTY_OFFICE_4_F2 ZN | Cooling | 595.69245 | 685.04631 | 4.37037E-002 | 5.02593E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 85 | CB_FACULTY_OFFICE_4_F2 ZN | Heating | 223.31965 | 279.14956 | 9.41756E-003 | 1.17719E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 86 | CB_FACULTY_OFFICE_4_F3 ZN | Cooling | 599.74154 | 689.70278 | 4.40009E-002 | 5.06011E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 87 | CB_FACULTY_OFFICE_4_F3 ZN | Heating | 247.44898 | 309.31123 | 1.04180E-002 | 1.30224E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 88 | CB_FACULTY_OFFICE_4_F4 ZN | Cooling | 697.38917 | 801.99754 | 5.11650E-002 | 5.88398E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 89 | CB_FACULTY_OFFICE_4_F4 ZN | Heating | 338.09996 | 422.62495 | 1.41159E-002 | 1.76449E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 90 | CB_FACULTY_OFFICE_5_F2 ZN | Cooling | 595.62272 | 684.96613 | 4.36986E-002 | 5.02534E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 91 | CB_FACULTY_OFFICE_5_F2 ZN | Heating | 223.26116 | 279.07645 | 9.41514E-003 | 1.17689E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 92 | CB_FACULTY_OFFICE_5_F3 ZN | Cooling | 599.82938 | 689.80378 | 4.40074E-002 | 5.06085E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 93 | CB_FACULTY_OFFICE_5_F3 ZN | Heating | 247.52217 | 309.40272 | 1.04210E-002 | 1.30262E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 94 | CB_FACULTY_OFFICE_5_F4 ZN | Cooling | 697.44690 | 802.06394 | 5.11693E-002 | 5.88446E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 95 | CB_FACULTY_OFFICE_5_F4 ZN | Heating | 338.14459 | 422.68074 | 1.41177E-002 | 1.76471E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 96 | CB_FACULTY_OFFICE_6_F2 ZN | Cooling | 596.20489 | 685.63562 | 4.37413E-002 | 5.03025E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 97 | CB_FACULTY_OFFICE_6_F2 ZN | Heating | 223.58734 | 279.48418 | 9.42880E-003 | 1.17860E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 98 | CB_FACULTY_OFFICE_6_F3 ZN | Cooling | 599.83039 | 689.80495 | 4.40075E-002 | 5.06086E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 99 | CB_FACULTY_OFFICE_6_F3 ZN | Heating | 247.25975 | 309.07468 | 1.04102E-002 | 1.30128E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 100 | CB_FACULTY_OFFICE_6_F4 ZN | Cooling | 697.57112 | 802.20678 | 5.11784E-002 | 5.88551E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 101 | CB_FACULTY_OFFICE_6_F4 ZN | Heating | 337.32825 | 421.66032 | 1.40852E-002 | 1.76066E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 102 | CB_FACULTY_OFFICE_7_F2 ZN | Cooling | 596.00182 | 685.40209 | 4.37264E-002 | 5.02854E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 103 | CB_FACULTY_OFFICE_7_F2 ZN | Heating | 222.27756 | 277.84695 | 9.37501E-003 | 1.17188E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 104 | CB_FACULTY_OFFICE_7_F3 ZN | Cooling | 600.01954 | 690.02248 | 4.40213E-002 | 5.06245E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 105 | CB_FACULTY_OFFICE_7_F3 ZN | Heating | 245.38465 | 306.73081 | 1.03332E-002 | 1.29166E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 106 | CB_FACULTY_OFFICE_7_F4 ZN | Cooling | 699.15658 | 804.03007 | 5.12947E-002 | 5.89889E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 107 | CB_FACULTY_OFFICE_7_F4 ZN | Heating | 330.12476 | 412.65595 | 1.37957E-002 | 1.72446E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 108 | CB_FACULTY_OFFICE_8_F2 ZN | Cooling | 595.17634 | 684.45280 | 4.36658E-002 | 5.02157E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 33.50500 | 1.65356E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 109 | CB_FACULTY_OFFICE_8_F2 ZN | Heating | 212.70779 | 265.88474 | 8.98148E-003 | 1.12268E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 110 | CB_FACULTY_OFFICE_8_F3 ZN | Cooling | 600.86678 | 690.99679 | 4.40835E-002 | 5.06960E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 33.50500 | 1.65356E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 111 | CB_FACULTY_OFFICE_8_F3 ZN | Heating | 231.24530 | 289.05663 | 9.75099E-003 | 1.21887E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 112 | CB_FACULTY_OFFICE_8_F4 ZN | Cooling | 717.10315 | 824.66863 | 5.26113E-002 | 6.05030E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 113 | CB_FACULTY_OFFICE_8_F4 ZN | Heating | 266.57124 | 333.21405 | 1.12047E-002 | 1.40058E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 114 | CB_FACULTY_RESTROOMS_1_F2 ZN | Cooling | 127.76310 | 146.92756 | 9.37262E-003 | 1.07785E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 115 | CB_FACULTY_RESTROOMS_1_F3 ZN | Cooling | 122.92823 | 141.36747 | 9.01794E-003 | 1.03706E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 116 | CB_FACULTY_RESTROOMS_1_F4 ZN | Cooling | 185.18716 | 212.96523 | 1.35852E-002 | 1.56230E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 33.90000 | 1.65364E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 117 | CB_FACULTY_RESTROOMS_2_F2 ZN | Cooling | 126.72378 | 145.73235 | 9.29638E-003 | 1.06908E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 118 | CB_FACULTY_RESTROOMS_2_F3 ZN | Cooling | 127.93112 | 147.12079 | 9.38495E-003 | 1.07927E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 119 | CB_FACULTY_RESTROOMS_2_F4 ZN | Cooling | 180.61662 | 207.70911 | 1.32499E-002 | 1.52374E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 33.90000 | 1.65364E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 120 | CB_LAB_1_F4 ZN | Cooling | 11873.97455 | 13655.07073 | 0.87114 | 1.00181 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 135.17392 | 36.37500 | 0.00000 | 0.00000 |
| 121 | CB_LAB_1_F4 ZN | Heating | 325.09127 | 406.36409 | 1.39625E-002 | 1.74531E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 135.17392 | 36.37500 | 0.00000 | 0.00000 |
| 122 | CB_LAB_2_F4 ZN | Cooling | 9186.03621 | 10563.94164 | 0.67396 | 0.77505 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 33.90000 | 1.65364E-002 | 135.17392 | 36.37500 | 0.00000 | 0.00000 |
| 123 | CB_LAB_3_F4 ZN | Cooling | 9186.51441 | 10564.49157 | 0.67399 | 0.77509 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 33.90000 | 1.65364E-002 | 135.17392 | 36.37500 | 0.00000 | 0.00000 |
| 124 | CB_LAB_4_F4 ZN | Cooling | 11135.14260 | 12805.41399 | 0.81697 | 0.93951 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:30:00 | 32.47800 | 1.65337E-002 | 135.17392 | 36.37500 | 0.00000 | 0.00000 |
| 125 | CB_LAB_4_F4 ZN | Heating | 368.89055 | 461.11318 | 1.58330E-002 | 1.97912E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 135.17392 | 36.37500 | 0.00000 | 0.00000 |
| 126 | CB_LECTURE_ROOM_1_F1 ZN | Cooling | 11687.71472 | 13440.87193 | 0.85781 | 0.98648 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | 32.60967 | 1.65339E-002 | 270.34785 | 189.15000 | 0.00000 | 0.00000 |
| 127 | CB_LECTURE_ROOM_1_F1 ZN | Heating | 1746.55360 | 2183.19200 | 7.40636E-002 | 9.25795E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 270.34785 | 189.15000 | 0.00000 | 0.00000 |
| 128 | CB_LECTURE_ROOM_2_F1 ZN | Cooling | 6973.20740 | 8019.18851 | 0.51179 | 0.58856 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 150.50292 | 105.30000 | 0.00000 | 0.00000 |
| 129 | CB_LECTURE_ROOM_2_F1 ZN | Heating | 1836.77320 | 2295.96650 | 7.72333E-002 | 9.65416E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 150.50292 | 105.30000 | 0.00000 | 0.00000 |
| 130 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | Cooling | 9378.83429 | 10785.65943 | 0.68807 | 0.79128 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 270.34785 | 29.10000 | 6.86684E-002 | 0.00000 |
| 131 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | Heating | 1071.28866 | 1339.11083 | 4.57549E-002 | 6.86684E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 270.34785 | 29.10000 | 6.86684E-002 | 0.00000 |
| 132 | CB_MAIN_STAIRS_F1 ZN | Cooling | 363.59963 | 418.13957 | 2.66737E-002 | 3.06748E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 133 | CB_MAIN_STAIRS_F1 ZN | Heating | 229.78070 | 287.22587 | 9.73374E-003 | 1.21672E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 134 | CB_MAIN_STAIRS_F2 ZN | Cooling | 338.87321 | 389.70419 | 2.48599E-002 | 2.85889E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 135 | CB_MAIN_STAIRS_F2 ZN | Heating | 263.13456 | 328.91820 | 1.11142E-002 | 1.38928E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 136 | CB_MAIN_STAIRS_F3 ZN | Cooling | 339.19314 | 390.07211 | 2.48835E-002 | 2.86160E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 137 | CB_MAIN_STAIRS_F3 ZN | Heating | 315.02350 | 393.77937 | 1.32531E-002 | 1.65664E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 138 | CB_MAIN_STAIRS_F4 ZN | Cooling | 453.20711 | 521.18818 | 3.32477E-002 | 3.82348E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 139 | CB_MAIN_STAIRS_F4 ZN | Heating | 393.42484 | 491.78105 | 1.64623E-002 | 2.05779E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 18.58061 | 0.00000 | 1.88779E-003 | 0.00000 |
| 140 | CB_OFFICES_ENCLOSED_1_F1 ZN | Cooling | 581.62465 | 668.86834 | 4.26713E-002 | 4.90720E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 141 | CB_OFFICES_ENCLOSED_1_F1 ZN | Heating | 184.22302 | 230.27878 | 7.80451E-003 | 9.75564E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 142 | CB_OFFICES_ENCLOSED_2_F1 ZN | Cooling | 579.18590 | 666.06378 | 4.24924E-002 | 4.88663E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 143 | CB_OFFICES_ENCLOSED_2_F1 ZN | Heating | 188.65471 | 235.81839 | 7.98844E-003 | 9.98555E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 144 | CB_OFFICES_ENCLOSED_3_F1 ZN | Cooling | 578.78206 | 665.59937 | 4.24628E-002 | 4.88322E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 145 | CB_OFFICES_ENCLOSED_3_F1 ZN | Heating | 189.10213 | 236.37766 | 8.00696E-003 | 1.00087E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 146 | CB_OFFICES_ENCLOSED_4_F1 ZN | Cooling | 578.74788 | 665.56006 | 4.24603E-002 | 4.88293E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 147 | CB_OFFICES_ENCLOSED_4_F1 ZN | Heating | 189.16206 | 236.45258 | 8.00944E-003 | 1.00118E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 148 | CB_OFFICES_ENCLOSED_5_F1 ZN | Cooling | 578.69471 | 665.49892 | 4.24564E-002 | 4.88248E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 149 | CB_OFFICES_ENCLOSED_5_F1 ZN | Heating | 189.11081 | 236.38852 | 8.00730E-003 | 1.00091E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 150 | CB_OFFICES_ENCLOSED_6_F1 ZN | Cooling | 578.65958 | 665.45852 | 4.24538E-002 | 4.88219E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 151 | CB_OFFICES_ENCLOSED_6_F1 ZN | Heating | 188.96637 | 236.20796 | 8.00132E-003 | 1.00016E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 152 | CB_OFFICES_ENCLOSED_7_F1 ZN | Cooling | 578.72903 | 665.53838 | 4.24589E-002 | 4.88277E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 153 | CB_OFFICES_ENCLOSED_7_F1 ZN | Heating | 188.07647 | 235.09559 | 7.96448E-003 | 9.95560E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 154 | CB_OFFICES_ENCLOSED_8_F1 ZN | Cooling | 577.68285 | 664.33528 | 4.23821E-002 | 4.87395E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 33.50500 | 1.65356E-002 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 155 | CB_OFFICES_ENCLOSED_8_F1 ZN | Heating | 179.47768 | 224.34710 | 7.60758E-003 | 9.50947E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.26320 | 0.66000 | 1.55743E-003 | 0.00000 |
| 156 | CB_OFFICES_OPEN_F1 ZN | Cooling | 4162.12185 | 4786.44013 | 0.30536 | 0.35116 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:50:00 | 32.89933 | 1.65345E-002 | 194.16735 | 10.45000 | 2.46593E-002 | 0.00000 |
| 157 | CB_OFFICES_OPEN_F1 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 2.46593E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 194.16735 | 10.45000 | 2.46593E-002 | 0.00000 | |
| 158 | CB_OFFICES_OPEN_F2 ZN | Cooling | 4508.28223 | 5184.52457 | 0.33076 | 0.38037 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 209.49636 | 11.27500 | 2.66060E-002 | 0.00000 |
| 159 | CB_OFFICES_OPEN_F2 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 2.66060E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 209.49636 | 11.27500 | 2.66060E-002 | 0.00000 | |
| 160 | CB_OFFICES_OPEN_F3 ZN | Cooling | 4548.64425 | 5230.94088 | 0.33372 | 0.38377 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 209.49636 | 11.27500 | 2.66060E-002 | 0.00000 |
| 161 | CB_OFFICES_OPEN_F3 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 2.66060E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 209.49636 | 11.27500 | 2.66060E-002 | 0.00000 | |
| 162 | CB_OFFICES_OPEN_F4 ZN | Cooling | 5747.33306 | 6609.43302 | 0.42166 | 0.48491 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 209.49636 | 11.27500 | 2.66060E-002 | 0.00000 |
| 163 | CB_OFFICES_OPEN_F4 ZN | Heating | 0.00000 | 0.00000 | 0.00000 | 2.66060E-002 | 00:10:00 | 27.34300 | 1.65240E-002 | 209.49636 | 11.27500 | 2.66060E-002 | 0.00000 | |
| 164 | CB_SECONDARY_STAIRS_1_F1 ZN | Cooling | 615.50247 | 707.82784 | 4.51534E-002 | 5.19264E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 32.66233 | 1.65340E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 165 | CB_SECONDARY_STAIRS_1_F1 ZN | Heating | 7.43159 | 9.28949 | 3.20686E-004 | 1.27426E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 166 | CB_SECONDARY_STAIRS_1_F2 ZN | Cooling | 586.37830 | 674.33505 | 4.30170E-002 | 4.94696E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:20:00 | 32.53067 | 1.65338E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 167 | CB_SECONDARY_STAIRS_1_F2 ZN | Heating | 214.85154 | 268.56443 | 9.06375E-003 | 1.13297E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 168 | CB_SECONDARY_STAIRS_1_F3 ZN | Cooling | 590.57331 | 679.15931 | 4.33249E-002 | 4.98236E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:20:00 | 32.53067 | 1.65338E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 169 | CB_SECONDARY_STAIRS_1_F3 ZN | Heating | 253.31738 | 316.64673 | 1.06515E-002 | 1.33144E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 170 | CB_SECONDARY_STAIRS_1_F4 ZN | Cooling | 722.54161 | 830.92285 | 5.30063E-002 | 6.09572E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 32.66233 | 1.65340E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 171 | CB_SECONDARY_STAIRS_1_F4 ZN | Heating | 308.98094 | 386.22618 | 1.29260E-002 | 1.61576E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 172 | CB_SECONDARY_STAIRS_2_F1 ZN | Cooling | 482.29848 | 554.64325 | 3.53815E-002 | 4.06888E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:50:00 | 31.88550 | 1.65326E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 173 | CB_SECONDARY_STAIRS_2_F1 ZN | Heating | 213.49231 | 266.86539 | 9.01832E-003 | 1.12729E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 174 | CB_SECONDARY_STAIRS_2_F2 ZN | Cooling | 518.92199 | 596.76028 | 3.80684E-002 | 4.37787E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:50:00 | 31.88550 | 1.65326E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 175 | CB_SECONDARY_STAIRS_2_F2 ZN | Heating | 254.70729 | 318.38411 | 1.07058E-002 | 1.33823E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 176 | CB_SECONDARY_STAIRS_2_F3 ZN | Cooling | 524.16125 | 602.78544 | 3.84529E-002 | 4.42209E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:50:00 | 31.88550 | 1.65326E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 177 | CB_SECONDARY_STAIRS_2_F3 ZN | Heating | 263.60451 | 329.50564 | 1.10756E-002 | 1.38445E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 178 | CB_SECONDARY_STAIRS_2_F4 ZN | Cooling | 650.46454 | 748.03422 | 4.77187E-002 | 5.48765E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:00:00 | 32.08300 | 1.65329E-002 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 179 | CB_SECONDARY_STAIRS_2_F4 ZN | Heating | 315.66809 | 394.58511 | 1.31964E-002 | 1.64955E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 12.54191 | 0.00000 | 1.27426E-003 | 0.00000 |
| 180 | CB_STAFF_RESTROOMS_1_F1 ZN | Cooling | 127.61229 | 146.75413 | 9.36156E-003 | 1.07658E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 181 | CB_STAFF_RESTROOMS_2_F1 ZN | Cooling | 142.48049 | 163.85256 | 1.04523E-002 | 1.20201E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 9.96385 | 0.00000 | 0.00000 | 0.00000 |
| 182 | CB_STORAGE_F1 ZN | Cooling | 4076.96206 | 4688.50637 | 0.29909 | 0.34395 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 75.25146 | 0.00000 | 0.00000 | 0.00000 |
| 183 | CB_STORAGE_F1 ZN | Heating | 332.63264 | 415.79080 | 1.42500E-002 | 1.78125E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 75.25146 | 0.00000 | 0.00000 | 0.00000 |
| 184 | CB_STUDENTS_RESTROOMS_1_F1 ZN | Cooling | 243.86868 | 280.44898 | 1.78901E-002 | 2.05736E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 185 | CB_STUDENTS_RESTROOMS_1_F2 ZN | Cooling | 228.34105 | 262.59221 | 1.67510E-002 | 1.92636E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 186 | CB_STUDENTS_RESTROOMS_1_F3 ZN | Cooling | 224.81789 | 258.54057 | 1.64925E-002 | 1.89664E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 187 | CB_STUDENTS_RESTROOMS_1_F4 ZN | Cooling | 326.49390 | 375.46799 | 2.39514E-002 | 2.75441E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 33.90000 | 1.65364E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 188 | CB_STUDENTS_RESTROOMS_2_F1 ZN | Cooling | 278.21097 | 319.94261 | 2.04094E-002 | 2.34708E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 189 | CB_STUDENTS_RESTROOMS_2_F2 ZN | Cooling | 260.25166 | 299.28941 | 1.90919E-002 | 2.19557E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 190 | CB_STUDENTS_RESTROOMS_2_F3 ZN | Cooling | 259.43492 | 298.35016 | 1.90320E-002 | 2.18868E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 191 | CB_STUDENTS_RESTROOMS_2_F4 ZN | Cooling | 388.99636 | 447.34581 | 2.85365E-002 | 3.28170E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 33.82100 | 1.65362E-002 | 19.16125 | 0.00000 | 0.00000 | 0.00000 |
| 192 | CB_STUDIO_1_F2 ZN | Cooling | 10844.78486 | 12471.50259 | 0.79568 | 0.91503 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 193 | CB_STUDIO_1_F2 ZN | Heating | 1544.81491 | 1931.01864 | 6.56809E-002 | 8.21012E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 194 | CB_STUDIO_1_F3 ZN | Cooling | 9816.67777 | 11289.17943 | 0.72025 | 0.82829 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 33.58400 | 1.65358E-002 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 195 | CB_STUDIO_1_F3 ZN | Heating | 1726.56707 | 2158.20884 | 7.31626E-002 | 9.14532E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 196 | CB_STUDIO_2_F2 ZN | Cooling | 9555.92216 | 10989.31048 | 0.70112 | 0.80628 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 33.66300 | 1.65359E-002 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 197 | CB_STUDIO_2_F2 ZN | Heating | 1879.24045 | 2349.05056 | 7.96450E-002 | 9.95562E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 198 | CB_STUDIO_2_F3 ZN | Cooling | 11057.87328 | 12716.55427 | 0.81132 | 0.93301 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 32.79400 | 1.65343E-002 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 199 | CB_STUDIO_2_F3 ZN | Heating | 1612.16276 | 2015.20345 | 6.83776E-002 | 8.54719E-002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 299.61230 | 64.50000 | 0.00000 | 0.00000 |
| 200 | CB_UTILITY_F1 ZN | Cooling | 1259.05613 | 1447.91455 | 9.23636E-002 | 0.10622 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 33.11000 | 1.65349E-002 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 201 | CB_UTILITY_F1 ZN | Heating | 14.26727 | 17.83409 | 6.14205E-004 | 8.30628E-004 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 202 | CB_UTILITY_F2 ZN | Cooling | 284.07600 | 326.68740 | 2.08396E-002 | 2.39656E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 203 | CB_UTILITY_F2 ZN | Heating | 25.37175 | 31.71468 | 1.08891E-003 | 1.36114E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 204 | CB_UTILITY_F3 ZN | Cooling | 148.98382 | 171.33140 | 1.09294E-002 | 1.25688E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 33.42600 | 1.65355E-002 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 205 | CB_UTILITY_F3 ZN | Heating | 39.71242 | 49.64053 | 1.69934E-003 | 2.12418E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 206 | CB_UTILITY_F4 ZN | Cooling | 193.45741 | 222.47602 | 1.41919E-002 | 1.63207E-002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 33.74200 | 1.65361E-002 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| 207 | CB_UTILITY_F4 ZN | Heating | 82.01553 | 102.51941 | 3.47987E-003 | 4.34984E-003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4.60000 | 5.25715E-003 | 8.17547 | 0.00000 | 8.30628E-004 | 0.00000 |
| System Name | Load Type | Peak Load Kind | User Design Capacity | Calc Des Air Flow Rate [m3/s] | User Des Air Flow Rate [m3/s] | Design Day Name | Date/Time of Peak | |
| 1 | VAV_1 | Cooling | Sensible | 78629.19 | 5.61359 | 5.61359 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
| 2 | VAV_1 | Heating | Sensible | 2694.64 | 0.52683 | 0.52683 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 |
| 3 | VAV_2 | Cooling | Sensible | 65989.84 | 4.79433 | 4.79433 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
| 4 | VAV_2 | Heating | Sensible | 1479.88 | 0.63995 | 0.63995 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 |
| 5 | VAV_3 | Cooling | Sensible | 65399.06 | 4.75031 | 4.75031 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
| 6 | VAV_3 | Heating | Sensible | 1508.28 | 0.73275 | 0.73275 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 |
| 7 | VAV_4 | Cooling | Sensible | 96036.61 | 7.02443 | 7.02443 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 00:00:00 |
| 8 | VAV_4 | Heating | Sensible | 1540.47 | 0.78384 | 0.78384 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 |
| Component Type | Component Name | Input Field Description | Value | |
| 1 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.40918 |
| 2 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 9.72073E-002 |
| 3 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 4 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.40918E-002 |
| 5 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
| 6 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 7 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.91946E-003 |
| 8 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.04945E-006 |
| 9 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.40918E-002 |
| 10 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 11 | AirTerminal:SingleDuct:VAV:Reheat | CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 12 | Coil:Heating:Water | CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 47.97952 |
| 13 | Coil:Heating:Water | CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.04945E-006 |
| 14 | Coil:Heating:Water | CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.77768 |
| 15 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.28058 |
| 16 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.15327 |
| 17 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 18 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.80583E-003 |
| 19 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.50458 |
| 20 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 21 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.48574E-003 |
| 22 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.07979E-005 |
| 23 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 6.78595E-002 |
| 24 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 25 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 26 | Coil:Heating:Water | CB_CLASSROOM_1_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 2322.41741 |
| 27 | Coil:Heating:Water | CB_CLASSROOM_1_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.07979E-005 |
| 28 | Coil:Heating:Water | CB_CLASSROOM_1_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 48.59919 |
| 29 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.28072 |
| 30 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.15320 |
| 31 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 32 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.80721E-003 |
| 33 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.50433 |
| 34 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 35 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.48696E-003 |
| 36 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.40131E-005 |
| 37 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 7.20876E-002 |
| 38 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 39 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 40 | Coil:Heating:Water | CB_CLASSROOM_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 2469.41353 |
| 41 | Coil:Heating:Water | CB_CLASSROOM_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.40131E-005 |
| 42 | Coil:Heating:Water | CB_CLASSROOM_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 51.69023 |
| 43 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.42737 |
| 44 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.13417 |
| 45 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 46 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 4.27369E-003 |
| 47 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.35780 |
| 48 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 49 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.83961E-003 |
| 50 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.64484E-005 |
| 51 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.10164 |
| 52 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 53 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 54 | Coil:Heating:Water | CB_CLASSROOM_1_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 3495.12769 |
| 55 | Coil:Heating:Water | CB_CLASSROOM_1_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.64484E-005 |
| 56 | Coil:Heating:Water | CB_CLASSROOM_1_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 73.24896 |
| 57 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.21104 |
| 58 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20378 |
| 59 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 60 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.11039E-003 |
| 61 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.67085 |
| 62 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 63 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.86963E-003 |
| 64 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.10538E-005 |
| 65 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.83947E-002 |
| 66 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 67 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 68 | Coil:Heating:Water | CB_CLASSROOM_2_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 962.55600 |
| 69 | Coil:Heating:Water | CB_CLASSROOM_2_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.10538E-005 |
| 70 | Coil:Heating:Water | CB_CLASSROOM_2_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 20.08330 |
| 71 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.21096 |
| 72 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20386 |
| 73 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 74 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.10958E-003 |
| 75 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.67111 |
| 76 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 77 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.86891E-003 |
| 78 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.27694E-005 |
| 79 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 3.06916E-002 |
| 80 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 81 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 82 | Coil:Heating:Water | CB_CLASSROOM_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1040.99078 |
| 83 | Coil:Heating:Water | CB_CLASSROOM_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.27694E-005 |
| 84 | Coil:Heating:Water | CB_CLASSROOM_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 21.72347 |
| 85 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.31375 |
| 86 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.18276 |
| 87 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 88 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.13747E-003 |
| 89 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.48737 |
| 90 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 91 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.08466E-003 |
| 92 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.17761E-005 |
| 93 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.60075E-002 |
| 94 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 95 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 96 | Coil:Heating:Water | CB_CLASSROOM_2_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1909.95363 |
| 97 | Coil:Heating:Water | CB_CLASSROOM_2_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.17761E-005 |
| 98 | Coil:Heating:Water | CB_CLASSROOM_2_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 39.92355 |
| 99 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.21059 |
| 100 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20422 |
| 101 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 102 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.10586E-003 |
| 103 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.67230 |
| 104 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 105 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.86562E-003 |
| 106 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.85481E-005 |
| 107 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.50585E-002 |
| 108 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 109 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 110 | Coil:Heating:Water | CB_CLASSROOM_3_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 847.99524 |
| 111 | Coil:Heating:Water | CB_CLASSROOM_3_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.85481E-005 |
| 112 | Coil:Heating:Water | CB_CLASSROOM_3_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 17.68368 |
| 113 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.20588 |
| 114 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20889 |
| 115 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 116 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.05885E-003 |
| 117 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.68765 |
| 118 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 119 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.82397E-003 |
| 120 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.96701E-005 |
| 121 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.65591E-002 |
| 122 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 123 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 124 | Coil:Heating:Water | CB_CLASSROOM_3_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 899.29209 |
| 125 | Coil:Heating:Water | CB_CLASSROOM_3_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.96701E-005 |
| 126 | Coil:Heating:Water | CB_CLASSROOM_3_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 18.75669 |
| 127 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.30549 |
| 128 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.18771 |
| 129 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 130 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.05488E-003 |
| 131 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.50055 |
| 132 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 133 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.02978E-003 |
| 134 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.97011E-005 |
| 135 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.32705E-002 |
| 136 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 137 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 138 | Coil:Heating:Water | CB_CLASSROOM_3_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1815.08612 |
| 139 | Coil:Heating:Water | CB_CLASSROOM_3_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.97011E-005 |
| 140 | Coil:Heating:Water | CB_CLASSROOM_3_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 37.93066 |
| 141 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.23504 |
| 142 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.18297 |
| 143 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 144 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.35043E-003 |
| 145 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.60234 |
| 146 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 147 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.08229E-003 |
| 148 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.88730E-005 |
| 149 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.55029E-002 |
| 150 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 151 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 152 | Coil:Heating:Water | CB_CLASSROOM_4_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 862.85199 |
| 153 | Coil:Heating:Water | CB_CLASSROOM_4_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.88730E-005 |
| 154 | Coil:Heating:Water | CB_CLASSROOM_4_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 17.99234 |
| 155 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.20757 |
| 156 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20719 |
| 157 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 158 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.07568E-003 |
| 159 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.68207 |
| 160 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 161 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.83888E-003 |
| 162 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.05374E-005 |
| 163 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.77290E-002 |
| 164 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 165 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 166 | Coil:Heating:Water | CB_CLASSROOM_4_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 938.94606 |
| 167 | Coil:Heating:Water | CB_CLASSROOM_4_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.05374E-005 |
| 168 | Coil:Heating:Water | CB_CLASSROOM_4_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 19.58403 |
| 169 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.31209 |
| 170 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.18374 |
| 171 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 172 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.12085E-003 |
| 173 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.48997 |
| 174 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 175 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.07362E-003 |
| 176 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.26054E-005 |
| 177 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.71357E-002 |
| 178 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 179 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 180 | Coil:Heating:Water | CB_CLASSROOM_4_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1947.86857 |
| 181 | Coil:Heating:Water | CB_CLASSROOM_4_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.26054E-005 |
| 182 | Coil:Heating:Water | CB_CLASSROOM_4_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 40.71246 |
| 183 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.19749 |
| 184 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.21777 |
| 185 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 186 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.97489E-003 |
| 187 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.71688 |
| 188 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 189 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.74959E-003 |
| 190 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.51978E-005 |
| 191 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.05743E-002 |
| 192 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 193 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 194 | Coil:Heating:Water | CB_CLASSROOM_5_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 694.82653 |
| 195 | Coil:Heating:Water | CB_CLASSROOM_5_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.51978E-005 |
| 196 | Coil:Heating:Water | CB_CLASSROOM_5_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 14.48056 |
| 197 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.19830 |
| 198 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.21688 |
| 199 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 200 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.98296E-003 |
| 201 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.71396 |
| 202 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 203 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.75674E-003 |
| 204 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.80931E-005 |
| 205 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.44518E-002 |
| 206 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 207 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 208 | Coil:Heating:Water | CB_CLASSROOM_5_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 827.19672 |
| 209 | Coil:Heating:Water | CB_CLASSROOM_5_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.80931E-005 |
| 210 | Coil:Heating:Water | CB_CLASSROOM_5_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 17.24825 |
| 211 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.31335 |
| 212 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.18300 |
| 213 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 214 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.13348E-003 |
| 215 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.48799 |
| 216 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 217 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.08201E-003 |
| 218 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.22372E-005 |
| 219 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 5.66151E-002 |
| 220 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 221 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_5_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 222 | Coil:Heating:Water | CB_CLASSROOM_5_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1931.03273 |
| 223 | Coil:Heating:Water | CB_CLASSROOM_5_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.22372E-005 |
| 224 | Coil:Heating:Water | CB_CLASSROOM_5_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 40.36649 |
| 225 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.21210 |
| 226 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20277 |
| 227 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 228 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.12098E-003 |
| 229 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.66751 |
| 230 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 231 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.87901E-003 |
| 232 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.37749E-006 |
| 233 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.14100E-002 |
| 234 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 235 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 236 | Coil:Heating:Water | CB_CLASSROOM_6_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 383.00862 |
| 237 | Coil:Heating:Water | CB_CLASSROOM_6_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.37749E-006 |
| 238 | Coil:Heating:Water | CB_CLASSROOM_6_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.96749 |
| 239 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.20542 |
| 240 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20936 |
| 241 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 242 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.05418E-003 |
| 243 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.68921 |
| 244 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 245 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.81984E-003 |
| 246 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.82492E-005 |
| 247 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.46609E-002 |
| 248 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 249 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 250 | Coil:Heating:Water | CB_CLASSROOM_6_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 834.33136 |
| 251 | Coil:Heating:Water | CB_CLASSROOM_6_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.82492E-005 |
| 252 | Coil:Heating:Water | CB_CLASSROOM_6_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 17.39742 |
| 253 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.38085 |
| 254 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.15056 |
| 255 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 256 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.80847E-003 |
| 257 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.40150 |
| 258 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 259 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.53050E-003 |
| 260 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.74492E-005 |
| 261 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.10294 |
| 262 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 263 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_6_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 264 | Coil:Heating:Water | CB_CLASSROOM_6_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 3540.88232 |
| 265 | Coil:Heating:Water | CB_CLASSROOM_6_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.74492E-005 |
| 266 | Coil:Heating:Water | CB_CLASSROOM_6_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 74.21467 |
| 267 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.22258 |
| 268 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.19322 |
| 269 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 270 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.22576E-003 |
| 271 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.63608 |
| 272 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 273 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.97184E-003 |
| 274 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.54162E-006 |
| 275 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 8.92281E-003 |
| 276 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 277 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 278 | Coil:Heating:Water | CB_CLASSROOM_7_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 299.07507 |
| 279 | Coil:Heating:Water | CB_CLASSROOM_7_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.54162E-006 |
| 280 | Coil:Heating:Water | CB_CLASSROOM_7_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 6.21869 |
| 281 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.21238 |
| 282 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20249 |
| 283 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 284 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.12383E-003 |
| 285 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.66661 |
| 286 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 287 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.88154E-003 |
| 288 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.10160E-005 |
| 289 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.83561E-002 |
| 290 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 291 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_7_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 292 | Coil:Heating:Water | CB_CLASSROOM_7_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 960.82548 |
| 293 | Coil:Heating:Water | CB_CLASSROOM_7_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.10160E-005 |
| 294 | Coil:Heating:Water | CB_CLASSROOM_7_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 20.04449 |
| 295 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.31838 |
| 296 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.13508 |
| 297 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 298 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.18380E-003 |
| 299 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.44468 |
| 300 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 301 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.82059E-003 |
| 302 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.47844E-005 |
| 303 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 4.68348E-002 |
| 304 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 305 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 306 | Coil:Heating:Water | CB_CLASSROOM_8_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1590.29978 |
| 307 | Coil:Heating:Water | CB_CLASSROOM_8_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.47844E-005 |
| 308 | Coil:Heating:Water | CB_CLASSROOM_8_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 33.19782 |
| 309 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.30893 |
| 310 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.13921 |
| 311 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 312 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.08931E-003 |
| 313 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.45828 |
| 314 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 315 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.73688E-003 |
| 316 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.17310E-005 |
| 317 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 6.91033E-002 |
| 318 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 319 | AirTerminal:SingleDuct:VAV:Reheat | CB_CLASSROOM_8_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 320 | Coil:Heating:Water | CB_CLASSROOM_8_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 2365.07715 |
| 321 | Coil:Heating:Water | CB_CLASSROOM_8_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.17310E-005 |
| 322 | Coil:Heating:Water | CB_CLASSROOM_8_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 49.49249 |
| 323 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.19665 |
| 324 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.71993 |
| 325 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 326 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.13813E-003 |
| 327 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 328 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 329 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 330 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 331 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 332 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 333 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 334 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.13256 |
| 335 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 336 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 337 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.16186E-003 |
| 338 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 339 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 340 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 341 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 342 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 343 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 344 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 345 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.13231 |
| 346 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 347 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 348 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.15786E-003 |
| 349 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 350 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 351 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 352 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 353 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 354 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 355 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 356 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.15124 |
| 357 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.93608 |
| 358 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 359 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.46661E-003 |
| 360 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 361 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 362 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 363 | AirTerminal:SingleDuct:VAV:Reheat | CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 364 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 365 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 366 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 367 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.73993E-002 |
| 368 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.50780 |
| 369 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 8.00000E-002 |
| 370 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.79194E-003 |
| 371 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 372 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 373 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.50296E-004 |
| 374 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.23122E-005 |
| 375 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.66457E-002 |
| 376 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 377 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 378 | Coil:Heating:Water | CB_CORRIDOR_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 562.89749 |
| 379 | Coil:Heating:Water | CB_CORRIDOR_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.23122E-005 |
| 380 | Coil:Heating:Water | CB_CORRIDOR_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 11.73583 |
| 381 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 6.60091E-002 |
| 382 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.70782 |
| 383 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 0.13500 |
| 384 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 8.91123E-003 |
| 385 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 386 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 387 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.38270E-004 |
| 388 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.63639E-007 |
| 389 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 8.91123E-003 |
| 390 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 391 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 392 | Coil:Heating:Water | CB_CORRIDOR_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 30.34076 |
| 393 | Coil:Heating:Water | CB_CORRIDOR_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.63639E-007 |
| 394 | Coil:Heating:Water | CB_CORRIDOR_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.49178 |
| 395 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.35042 |
| 396 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.26566 |
| 397 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 5.10000E-002 |
| 398 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.78713E-002 |
| 399 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.70842 |
| 400 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 401 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.43417E-003 |
| 402 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.21376E-006 |
| 403 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.78713E-002 |
| 404 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 405 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 406 | Coil:Heating:Water | CB_CORRIDOR_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 192.64821 |
| 407 | Coil:Heating:Water | CB_CORRIDOR_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.21376E-006 |
| 408 | Coil:Heating:Water | CB_CORRIDOR_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 3.36789 |
| 409 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.13561 |
| 410 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.52204 |
| 411 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 9.50000E-002 |
| 412 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.28827E-002 |
| 413 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 414 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 415 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.29830E-004 |
| 416 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 4.12399E-006 |
| 417 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.28827E-002 |
| 418 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 419 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 420 | Coil:Heating:Water | CB_CORRIDOR_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 188.54381 |
| 421 | Coil:Heating:Water | CB_CORRIDOR_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.12399E-006 |
| 422 | Coil:Heating:Water | CB_CORRIDOR_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 3.41737 |
| 423 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.27584 |
| 424 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.41833 |
| 425 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 7.80000E-002 |
| 426 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.15155E-002 |
| 427 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 428 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 429 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.10770E-004 |
| 430 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.48559E-005 |
| 431 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 4.72457E-002 |
| 432 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 433 | AirTerminal:SingleDuct:VAV:Reheat | CB_CORRIDOR_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 434 | Coil:Heating:Water | CB_CORRIDOR_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1593.57012 |
| 435 | Coil:Heating:Water | CB_CORRIDOR_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.48559E-005 |
| 436 | Coil:Heating:Water | CB_CORRIDOR_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 33.19824 |
| 437 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.12983 |
| 438 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.44168 |
| 439 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 440 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.29825E-003 |
| 441 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 442 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 443 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 8.62609E-004 |
| 444 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.03916E-005 |
| 445 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.76109E-002 |
| 446 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 447 | AirTerminal:SingleDuct:VAV:Reheat | CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 448 | Coil:Heating:Water | CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 932.28087 |
| 449 | Coil:Heating:Water | CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.03916E-005 |
| 450 | Coil:Heating:Water | CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 19.42808 |
| 451 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.02134E-002 |
| 452 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 453 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 454 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.04732E-003 |
| 455 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.44830E-006 |
| 456 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.13957E-002 |
| 457 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 458 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 459 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 386.24625 |
| 460 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.44830E-006 |
| 461 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.05848 |
| 462 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06172E-002 |
| 463 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 464 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 465 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06378E-003 |
| 466 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.08283E-006 |
| 467 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.22424E-002 |
| 468 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 469 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 470 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 415.25624 |
| 471 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.08283E-006 |
| 472 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.66572 |
| 473 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 6.04415E-002 |
| 474 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 475 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 476 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.46435E-003 |
| 477 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.04436E-005 |
| 478 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.40456E-002 |
| 479 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 480 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 481 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 477.46838 |
| 482 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.04436E-005 |
| 483 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.97074 |
| 484 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.03430E-002 |
| 485 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 486 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 487 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.05261E-003 |
| 488 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.72588E-006 |
| 489 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.17630E-002 |
| 490 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 491 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 492 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 398.93671 |
| 493 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.72588E-006 |
| 494 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.32480 |
| 495 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06335E-002 |
| 496 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 497 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 498 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06445E-003 |
| 499 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.59933E-006 |
| 500 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.29270E-002 |
| 501 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 502 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 503 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 438.86993 |
| 504 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.59933E-006 |
| 505 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.16103 |
| 506 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.89799E-002 |
| 507 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 508 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 509 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.40475E-003 |
| 510 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.28768E-005 |
| 511 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.72475E-002 |
| 512 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 513 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 514 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 588.71128 |
| 515 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.28768E-005 |
| 516 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.30928 |
| 517 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.02943E-002 |
| 518 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 519 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 520 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.05062E-003 |
| 521 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.74180E-006 |
| 522 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.17838E-002 |
| 523 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 524 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 525 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 399.66462 |
| 526 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.74180E-006 |
| 527 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.34013 |
| 528 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06002E-002 |
| 529 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 530 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 531 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06309E-003 |
| 532 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.66148E-006 |
| 533 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.30091E-002 |
| 534 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 535 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 536 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 441.71133 |
| 537 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.66148E-006 |
| 538 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.22068 |
| 539 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.88502E-002 |
| 540 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 541 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 542 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.39946E-003 |
| 543 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.31511E-005 |
| 544 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.76049E-002 |
| 545 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 546 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 547 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 601.25336 |
| 548 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.31511E-005 |
| 549 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.57375 |
| 550 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.02593E-002 |
| 551 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 552 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 553 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.04919E-003 |
| 554 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.73297E-006 |
| 555 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.17719E-002 |
| 556 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 557 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 558 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 399.26101 |
| 559 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.73297E-006 |
| 560 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.33169 |
| 561 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06011E-002 |
| 562 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 563 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 564 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06313E-003 |
| 565 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.67155E-006 |
| 566 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.30224E-002 |
| 567 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 568 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 569 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 442.17161 |
| 570 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.67155E-006 |
| 571 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.23034 |
| 572 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.88398E-002 |
| 573 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 574 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 575 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.39904E-003 |
| 576 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.31820E-005 |
| 577 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.76449E-002 |
| 578 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 579 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 580 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 602.66730 |
| 581 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.31820E-005 |
| 582 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.60363 |
| 583 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.02534E-002 |
| 584 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 585 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 586 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.04895E-003 |
| 587 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.73070E-006 |
| 588 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.17689E-002 |
| 589 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 590 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 591 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 399.15697 |
| 592 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.73070E-006 |
| 593 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.32952 |
| 594 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06085E-002 |
| 595 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 596 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 597 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06343E-003 |
| 598 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.67440E-006 |
| 599 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.30262E-002 |
| 600 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 601 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 602 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 442.30183 |
| 603 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.67440E-006 |
| 604 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.23307 |
| 605 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.88446E-002 |
| 606 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 607 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 608 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.39924E-003 |
| 609 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.31838E-005 |
| 610 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.76471E-002 |
| 611 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 612 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 613 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 602.74638 |
| 614 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.31838E-005 |
| 615 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.60529 |
| 616 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.03025E-002 |
| 617 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 618 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 619 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.05095E-003 |
| 620 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.74343E-006 |
| 621 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.17860E-002 |
| 622 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 623 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 624 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 399.73910 |
| 625 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.74343E-006 |
| 626 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.34168 |
| 627 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06086E-002 |
| 628 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 629 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 630 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06343E-003 |
| 631 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.66422E-006 |
| 632 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.30128E-002 |
| 633 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 634 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 635 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 441.83631 |
| 636 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.66422E-006 |
| 637 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.22330 |
| 638 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.88551E-002 |
| 639 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 640 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 641 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.39966E-003 |
| 642 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.31524E-005 |
| 643 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.76066E-002 |
| 644 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 645 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 646 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 601.31153 |
| 647 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.31524E-005 |
| 648 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.57497 |
| 649 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.02854E-002 |
| 650 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 651 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 652 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.05025E-003 |
| 653 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.69260E-006 |
| 654 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.17188E-002 |
| 655 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 656 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 657 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 397.41534 |
| 658 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.69260E-006 |
| 659 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.29291 |
| 660 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06245E-002 |
| 661 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 662 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 663 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06408E-003 |
| 664 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.59146E-006 |
| 665 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.29166E-002 |
| 666 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 667 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 668 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 438.51000 |
| 669 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.59146E-006 |
| 670 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.15348 |
| 671 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.89889E-002 |
| 672 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 673 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 674 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.40512E-003 |
| 675 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.28746E-005 |
| 676 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.72446E-002 |
| 677 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 678 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 679 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 588.61166 |
| 680 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.28746E-005 |
| 681 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.30718 |
| 682 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.02157E-002 |
| 683 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 684 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 685 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.04741E-003 |
| 686 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.32110E-006 |
| 687 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.12268E-002 |
| 688 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 689 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 690 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 380.43067 |
| 691 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.32110E-006 |
| 692 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.93656 |
| 693 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.06960E-002 |
| 694 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 695 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 696 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.06700E-003 |
| 697 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.04234E-006 |
| 698 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.21887E-002 |
| 699 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 700 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 701 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 413.40500 |
| 702 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.04234E-006 |
| 703 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.62690 |
| 704 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 6.05030E-002 |
| 705 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 706 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 707 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.46685E-003 |
| 708 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.04137E-005 |
| 709 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.40058E-002 |
| 710 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 711 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 712 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 476.09975 |
| 713 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.04137E-005 |
| 714 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.94205 |
| 715 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.07785E-002 |
| 716 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.70441 |
| 717 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 718 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.07785E-004 |
| 719 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 720 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 721 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.40881E-004 |
| 722 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 723 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.07785E-004 |
| 724 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 725 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 726 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 727 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 728 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 729 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.03706E-002 |
| 730 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.73211 |
| 731 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 732 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.03706E-004 |
| 733 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 734 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 735 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.20413E-004 |
| 736 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 737 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.03706E-004 |
| 738 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 739 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 740 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 741 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 742 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 743 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.56230E-002 |
| 744 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.48598 |
| 745 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 746 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.56230E-004 |
| 747 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 748 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 749 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.83984E-004 |
| 750 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 751 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.56230E-004 |
| 752 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 753 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 754 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 755 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 756 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 757 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.06908E-002 |
| 758 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.71018 |
| 759 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 760 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.06908E-004 |
| 761 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 762 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 763 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.36481E-004 |
| 764 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 765 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.06908E-004 |
| 766 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 767 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 768 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 769 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 770 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 771 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.07927E-002 |
| 772 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.70348 |
| 773 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 774 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.07927E-004 |
| 775 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 776 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 777 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.41592E-004 |
| 778 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 779 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.07927E-004 |
| 780 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 781 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 782 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 783 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 784 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 785 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.52374E-002 |
| 786 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.49828 |
| 787 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 788 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.52374E-004 |
| 789 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 790 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 791 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.64635E-004 |
| 792 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 793 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.52374E-004 |
| 794 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 795 | AirTerminal:SingleDuct:VAV:Reheat | CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 796 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 797 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 798 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 799 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.00181 |
| 800 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.10282 |
| 801 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 802 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.00181E-002 |
| 803 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
| 804 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 805 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.70564E-003 |
| 806 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.27754E-005 |
| 807 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.74531E-002 |
| 808 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 809 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 810 | Coil:Heating:Water | CB_LAB_1_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 584.07682 |
| 811 | Coil:Heating:Water | CB_LAB_1_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.27754E-005 |
| 812 | Coil:Heating:Water | CB_LAB_1_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.13903 |
| 813 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.77505 |
| 814 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.13290 |
| 815 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 816 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 7.75050E-003 |
| 817 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.35439 |
| 818 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 819 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.86686E-003 |
| 820 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.77197E-007 |
| 821 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 7.75050E-003 |
| 822 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 823 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 824 | Coil:Heating:Water | CB_LAB_2_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 26.38874 |
| 825 | Coil:Heating:Water | CB_LAB_2_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.77197E-007 |
| 826 | Coil:Heating:Water | CB_LAB_2_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.42773 |
| 827 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.77509 |
| 828 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.13289 |
| 829 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 830 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 7.75091E-003 |
| 831 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.35438 |
| 832 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 833 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.86701E-003 |
| 834 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.77227E-007 |
| 835 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 7.75091E-003 |
| 836 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 837 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_3_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 838 | Coil:Heating:Water | CB_LAB_3_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 26.39011 |
| 839 | Coil:Heating:Water | CB_LAB_3_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.77227E-007 |
| 840 | Coil:Heating:Water | CB_LAB_3_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.42775 |
| 841 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.93951 |
| 842 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.10963 |
| 843 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 844 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 9.39512E-003 |
| 845 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.30000 |
| 846 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 847 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 3.47520E-003 |
| 848 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.44943E-005 |
| 849 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.97912E-002 |
| 850 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 851 | AirTerminal:SingleDuct:VAV:Reheat | CB_LAB_4_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 852 | Coil:Heating:Water | CB_LAB_4_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 662.66418 |
| 853 | Coil:Heating:Water | CB_LAB_4_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.44943E-005 |
| 854 | Coil:Heating:Water | CB_LAB_4_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 13.77447 |
| 855 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.98648 |
| 856 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.20883 |
| 857 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 858 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 9.86479E-003 |
| 859 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.55688 |
| 860 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 861 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.82446E-003 |
| 862 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.84186E-005 |
| 863 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.25795E-002 |
| 864 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 865 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 866 | Coil:Heating:Water | CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 3128.01532 |
| 867 | Coil:Heating:Water | CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.84186E-005 |
| 868 | Coil:Heating:Water | CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 65.19879 |
| 869 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.58856 |
| 870 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.19485 |
| 871 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 872 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 5.88563E-003 |
| 873 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.51961 |
| 874 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 875 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.95532E-003 |
| 876 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.17722E-005 |
| 877 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.65416E-002 |
| 878 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 879 | AirTerminal:SingleDuct:VAV:Reheat | CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 880 | Coil:Heating:Water | CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 3281.33856 |
| 881 | Coil:Heating:Water | CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.17722E-005 |
| 882 | Coil:Heating:Water | CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 68.51927 |
| 883 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.79128 |
| 884 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.26035 |
| 885 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 0.13700 |
| 886 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 0.10840 |
| 887 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.69425 |
| 888 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 889 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.46344E-003 |
| 890 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 5.34798E-005 |
| 891 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.10840 |
| 892 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 893 | AirTerminal:SingleDuct:VAV:Reheat | CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 894 | Coil:Heating:Water | CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 2445.03443 |
| 895 | Coil:Heating:Water | CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 5.34798E-005 |
| 896 | Coil:Heating:Water | CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 46.57983 |
| 897 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 3.06748E-002 |
| 898 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.46157 |
| 899 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 7.10000E-002 |
| 900 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.17791E-003 |
| 901 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 902 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 903 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 8.25452E-004 |
| 904 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.99894E-006 |
| 905 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.21672E-002 |
| 906 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 907 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 908 | Coil:Heating:Water | CB_MAIN_STAIRS_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 411.42067 |
| 909 | Coil:Heating:Water | CB_MAIN_STAIRS_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.99894E-006 |
| 910 | Coil:Heating:Water | CB_MAIN_STAIRS_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.57751 |
| 911 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.85889E-002 |
| 912 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.49524 |
| 913 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 7.30000E-002 |
| 914 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.08699E-003 |
| 915 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 916 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 917 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.69322E-004 |
| 918 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.02956E-005 |
| 919 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.38928E-002 |
| 920 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 921 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 922 | Coil:Heating:Water | CB_MAIN_STAIRS_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 470.70250 |
| 923 | Coil:Heating:Water | CB_MAIN_STAIRS_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.02956E-005 |
| 924 | Coil:Heating:Water | CB_MAIN_STAIRS_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.81940 |
| 925 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.86160E-002 |
| 926 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.49477 |
| 927 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 7.30000E-002 |
| 928 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.08897E-003 |
| 929 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 930 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 931 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.70050E-004 |
| 932 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.23110E-005 |
| 933 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.65664E-002 |
| 934 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 935 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 936 | Coil:Heating:Water | CB_MAIN_STAIRS_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 562.84642 |
| 937 | Coil:Heating:Water | CB_MAIN_STAIRS_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.23110E-005 |
| 938 | Coil:Heating:Water | CB_MAIN_STAIRS_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 11.75163 |
| 939 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 3.82348E-002 |
| 940 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.37030 |
| 941 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 5.70000E-002 |
| 942 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.17939E-003 |
| 943 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 944 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 945 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.02889E-003 |
| 946 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.53503E-005 |
| 947 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.05779E-002 |
| 948 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 949 | AirTerminal:SingleDuct:VAV:Reheat | CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 950 | Coil:Heating:Water | CB_MAIN_STAIRS_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 701.79647 |
| 951 | Coil:Heating:Water | CB_MAIN_STAIRS_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.53503E-005 |
| 952 | Coil:Heating:Water | CB_MAIN_STAIRS_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 14.66993 |
| 953 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.90720E-002 |
| 954 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 955 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 956 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.00078E-003 |
| 957 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.21444E-006 |
| 958 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.75564E-003 |
| 959 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 960 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 961 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 329.83552 |
| 962 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.21444E-006 |
| 963 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 6.87631 |
| 964 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.88663E-002 |
| 965 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 966 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 967 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99239E-003 |
| 968 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.38695E-006 |
| 969 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.98555E-003 |
| 970 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 971 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 972 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 337.72269 |
| 973 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.38695E-006 |
| 974 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.04147 |
| 975 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.88322E-002 |
| 976 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 977 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 978 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99101E-003 |
| 979 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.40436E-006 |
| 980 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.00087E-002 |
| 981 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 982 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 983 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 338.51827 |
| 984 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.40436E-006 |
| 985 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.05814 |
| 986 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.88293E-002 |
| 987 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 988 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 989 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99089E-003 |
| 990 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.40669E-006 |
| 991 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.00118E-002 |
| 992 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 993 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 994 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 338.62483 |
| 995 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.40669E-006 |
| 996 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.06037 |
| 997 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.88248E-002 |
| 998 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 999 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1000 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99070E-003 |
| 1001 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.40469E-006 |
| 1002 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.00091E-002 |
| 1003 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1004 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1005 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 338.53351 |
| 1006 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.40469E-006 |
| 1007 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.05846 |
| 1008 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.88219E-002 |
| 1009 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1010 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1011 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99058E-003 |
| 1012 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.39907E-006 |
| 1013 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.00016E-002 |
| 1014 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1015 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1016 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 338.27658 |
| 1017 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.39907E-006 |
| 1018 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.05308 |
| 1019 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.88277E-002 |
| 1020 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1021 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1022 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.99082E-003 |
| 1023 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.36446E-006 |
| 1024 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.95560E-003 |
| 1025 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1026 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1027 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 336.69406 |
| 1028 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.36446E-006 |
| 1029 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.01992 |
| 1030 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.87395E-002 |
| 1031 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1032 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1033 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.98722E-003 |
| 1034 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.02971E-006 |
| 1035 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.50947E-003 |
| 1036 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1037 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1038 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 321.39009 |
| 1039 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.02971E-006 |
| 1040 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 6.69947 |
| 1041 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.35116 |
| 1042 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1043 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1044 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.04279E-004 |
| 1045 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1046 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 1047 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1048 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1049 | Coil:Heating:Water | CB_OFFICES_OPEN_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1050 | Coil:Heating:Water | CB_OFFICES_OPEN_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1051 | Coil:Heating:Water | CB_OFFICES_OPEN_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1052 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.38037 |
| 1053 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1054 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1055 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.07818E-004 |
| 1056 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1057 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 1058 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1059 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1060 | Coil:Heating:Water | CB_OFFICES_OPEN_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1061 | Coil:Heating:Water | CB_OFFICES_OPEN_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1062 | Coil:Heating:Water | CB_OFFICES_OPEN_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1063 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.38377 |
| 1064 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1065 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1066 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.15945E-004 |
| 1067 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1068 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 1069 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1070 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1071 | Coil:Heating:Water | CB_OFFICES_OPEN_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1072 | Coil:Heating:Water | CB_OFFICES_OPEN_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1073 | Coil:Heating:Water | CB_OFFICES_OPEN_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1074 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.48491 |
| 1075 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.87789 |
| 1076 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1077 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.15732E-003 |
| 1078 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1079 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 0.00000 |
| 1080 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1081 | AirTerminal:SingleDuct:VAV:Reheat | CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1082 | Coil:Heating:Water | CB_OFFICES_OPEN_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1083 | Coil:Heating:Water | CB_OFFICES_OPEN_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1084 | Coil:Heating:Water | CB_OFFICES_OPEN_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1085 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.19264E-002 |
| 1086 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.18405 |
| 1087 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 3.50000E-002 |
| 1088 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.81742E-003 |
| 1089 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1090 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1091 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.07011E-003 |
| 1092 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.07663E-007 |
| 1093 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.81742E-003 |
| 1094 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1095 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1096 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 27.78162 |
| 1097 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.07663E-007 |
| 1098 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.50536 |
| 1099 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.94696E-002 |
| 1100 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.19319 |
| 1101 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 3.70000E-002 |
| 1102 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.83037E-003 |
| 1103 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1104 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1105 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.97217E-003 |
| 1106 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.40346E-006 |
| 1107 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.13297E-002 |
| 1108 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1109 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1110 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 384.19591 |
| 1111 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.40346E-006 |
| 1112 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 8.01690 |
| 1113 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.98236E-002 |
| 1114 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.19182 |
| 1115 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 3.70000E-002 |
| 1116 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.84347E-003 |
| 1117 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1118 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1119 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.98629E-003 |
| 1120 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.89814E-006 |
| 1121 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.33144E-002 |
| 1122 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1123 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1124 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 452.53106 |
| 1125 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.89814E-006 |
| 1126 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.44947 |
| 1127 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 6.09572E-002 |
| 1128 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.15678 |
| 1129 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 3.00000E-002 |
| 1130 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.82872E-003 |
| 1131 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1132 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1133 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.43014E-003 |
| 1134 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.20548E-005 |
| 1135 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.61576E-002 |
| 1136 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1137 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1138 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 551.13274 |
| 1139 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.20548E-005 |
| 1140 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 11.52112 |
| 1141 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.06888E-002 |
| 1142 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.23488 |
| 1143 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 4.60000E-002 |
| 1144 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.87168E-003 |
| 1145 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1146 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1147 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.62211E-003 |
| 1148 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 8.35419E-006 |
| 1149 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.12729E-002 |
| 1150 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1151 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1152 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 381.94341 |
| 1153 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 8.35419E-006 |
| 1154 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 7.96781 |
| 1155 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.37787E-002 |
| 1156 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.21830 |
| 1157 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 4.20000E-002 |
| 1158 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.83871E-003 |
| 1159 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1160 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1161 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.74530E-003 |
| 1162 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.95164E-006 |
| 1163 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.33823E-002 |
| 1164 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1165 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1166 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 454.97726 |
| 1167 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.95164E-006 |
| 1168 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.50144 |
| 1169 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 4.42209E-002 |
| 1170 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.21612 |
| 1171 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 4.20000E-002 |
| 1172 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.85728E-003 |
| 1173 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1174 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1175 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.76292E-003 |
| 1176 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.02978E-005 |
| 1177 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.38445E-002 |
| 1178 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1179 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1180 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 470.80353 |
| 1181 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.02978E-005 |
| 1182 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 9.83266 |
| 1183 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 5.48765E-002 |
| 1184 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.17415 |
| 1185 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 3.50000E-002 |
| 1186 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.92068E-003 |
| 1187 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1188 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1189 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.18772E-003 |
| 1190 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.23132E-005 |
| 1191 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.64955E-002 |
| 1192 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1193 | AirTerminal:SingleDuct:VAV:Reheat | CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1194 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 562.94293 |
| 1195 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.23132E-005 |
| 1196 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 11.76985 |
| 1197 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.07658E-002 |
| 1198 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.70524 |
| 1199 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1200 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.07658E-004 |
| 1201 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1202 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1203 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.40242E-004 |
| 1204 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1205 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.07658E-004 |
| 1206 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1207 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1208 | Coil:Heating:Water | CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1209 | Coil:Heating:Water | CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1210 | Coil:Heating:Water | CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1211 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.20201E-002 |
| 1212 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.63165 |
| 1213 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1214 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.20201E-004 |
| 1215 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1216 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1217 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.03187E-004 |
| 1218 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1219 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.20201E-004 |
| 1220 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1221 | AirTerminal:SingleDuct:VAV:Reheat | CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1222 | Coil:Heating:Water | CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1223 | Coil:Heating:Water | CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1224 | Coil:Heating:Water | CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1225 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.34395 |
| 1226 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.16672 |
| 1227 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1228 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.43949E-003 |
| 1229 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.44457 |
| 1230 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1231 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 2.28533E-003 |
| 1232 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.30697E-005 |
| 1233 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.78125E-002 |
| 1234 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1235 | AirTerminal:SingleDuct:VAV:Reheat | CB_STORAGE_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1236 | Coil:Heating:Water | CB_STORAGE_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 597.53057 |
| 1237 | Coil:Heating:Water | CB_STORAGE_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.30697E-005 |
| 1238 | Coil:Heating:Water | CB_STORAGE_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 12.42756 |
| 1239 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.05736E-002 |
| 1240 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.70969 |
| 1241 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1242 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.05736E-004 |
| 1243 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1244 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1245 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.36853E-004 |
| 1246 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1247 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.05736E-004 |
| 1248 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1249 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1250 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1251 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1252 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1253 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.92636E-002 |
| 1254 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.75795 |
| 1255 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1256 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.92636E-004 |
| 1257 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1258 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1259 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.02671E-004 |
| 1260 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1261 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.92636E-004 |
| 1262 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1263 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1264 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1265 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1266 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1267 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.89664E-002 |
| 1268 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.76983 |
| 1269 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1270 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.89664E-004 |
| 1271 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1272 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1273 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 4.94915E-004 |
| 1274 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1275 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.89664E-004 |
| 1276 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1277 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1278 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1279 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1280 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1281 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.75441E-002 |
| 1282 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.53009 |
| 1283 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1284 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.75441E-004 |
| 1285 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1286 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1287 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.18745E-004 |
| 1288 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1289 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.75441E-004 |
| 1290 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1291 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1292 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1293 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1294 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1295 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.34708E-002 |
| 1296 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.62209 |
| 1297 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1298 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.34708E-004 |
| 1299 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1300 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1301 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.12455E-004 |
| 1302 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1303 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.34708E-004 |
| 1304 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1305 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1306 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1307 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1308 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1309 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.19557E-002 |
| 1310 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.66502 |
| 1311 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1312 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.19557E-004 |
| 1313 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1314 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1315 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.72919E-004 |
| 1316 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1317 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.19557E-004 |
| 1318 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1319 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1320 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1321 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1322 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1323 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.18868E-002 |
| 1324 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.66711 |
| 1325 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1326 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 2.18868E-004 |
| 1327 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1328 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1329 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 5.71121E-004 |
| 1330 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 0.00000 |
| 1331 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.18868E-004 |
| 1332 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1333 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1334 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 0.00000 |
| 1335 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 0.00000 |
| 1336 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1337 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 3.28170E-002 |
| 1338 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.44492 |
| 1339 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1340 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 3.28170E-004 |
| 1341 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1342 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1343 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 8.56338E-004 |
| 1344 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 2.44395E-008 |
| 1345 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 3.28170E-004 |
| 1346 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1347 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1348 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 1.11735 |
| 1349 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 2.44395E-008 |
| 1350 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.00000 |
| 1351 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.91503 |
| 1352 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.24950 |
| 1353 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1354 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 9.15034E-003 |
| 1355 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.66534 |
| 1356 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1357 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.52703E-003 |
| 1358 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.05565E-005 |
| 1359 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 8.21012E-002 |
| 1360 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1361 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1362 | Coil:Heating:Water | CB_STUDIO_1_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 2768.57165 |
| 1363 | Coil:Heating:Water | CB_STUDIO_1_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.05565E-005 |
| 1364 | Coil:Heating:Water | CB_STUDIO_1_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 57.67246 |
| 1365 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.82829 |
| 1366 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.27563 |
| 1367 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1368 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 8.28287E-003 |
| 1369 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.73503 |
| 1370 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1371 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.38226E-003 |
| 1372 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.76109E-005 |
| 1373 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.14532E-002 |
| 1374 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1375 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_1_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1376 | Coil:Heating:Water | CB_STUDIO_1_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 3091.08993 |
| 1377 | Coil:Heating:Water | CB_STUDIO_1_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.76109E-005 |
| 1378 | Coil:Heating:Water | CB_STUDIO_1_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 64.43630 |
| 1379 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.80628 |
| 1380 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.28316 |
| 1381 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1382 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 8.06285E-003 |
| 1383 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.75508 |
| 1384 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1385 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.34555E-003 |
| 1386 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 7.35985E-005 |
| 1387 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 9.95562E-002 |
| 1388 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1389 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1390 | Coil:Heating:Water | CB_STUDIO_2_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 3364.83292 |
| 1391 | Coil:Heating:Water | CB_STUDIO_2_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.35985E-005 |
| 1392 | Coil:Heating:Water | CB_STUDIO_2_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 70.14183 |
| 1393 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.93301 |
| 1394 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.24470 |
| 1395 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.00000E-002 |
| 1396 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 9.33015E-003 |
| 1397 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 0.65252 |
| 1398 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1399 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.55704E-003 |
| 1400 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.31473E-005 |
| 1401 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 8.54719E-002 |
| 1402 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1403 | AirTerminal:SingleDuct:VAV:Reheat | CB_STUDIO_2_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1404 | Coil:Heating:Water | CB_STUDIO_2_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 2887.01826 |
| 1405 | Coil:Heating:Water | CB_STUDIO_2_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.31473E-005 |
| 1406 | Coil:Heating:Water | CB_STUDIO_2_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 60.17015 |
| 1407 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 0.10622 |
| 1408 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 5.86501E-002 |
| 1409 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 1.20000E-002 |
| 1410 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.27462E-003 |
| 1411 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1412 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1413 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 6.49615E-003 |
| 1414 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 6.74822E-007 |
| 1415 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.27462E-003 |
| 1416 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1417 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F1 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1418 | Coil:Heating:Water | CB_UTILITY_F1 ZN REHEAT COIL | Design Size Rated Capacity [W] | 30.85203 |
| 1419 | Coil:Heating:Water | CB_UTILITY_F1 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 6.74822E-007 |
| 1420 | Coil:Heating:Water | CB_UTILITY_F1 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.59479 |
| 1421 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 2.39656E-002 |
| 1422 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.25994 |
| 1423 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 4.80000E-002 |
| 1424 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.15035E-003 |
| 1425 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1426 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1427 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 1.46570E-003 |
| 1428 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 9.97792E-007 |
| 1429 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 1.36114E-003 |
| 1430 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1431 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F2 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1432 | Coil:Heating:Water | CB_UTILITY_F2 ZN REHEAT COIL | Design Size Rated Capacity [W] | 45.61784 |
| 1433 | Coil:Heating:Water | CB_UTILITY_F2 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.97792E-007 |
| 1434 | Coil:Heating:Water | CB_UTILITY_F2 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 0.94850 |
| 1435 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.25688E-002 |
| 1436 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.49565 |
| 1437 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 8.90000E-002 |
| 1438 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.11862E-003 |
| 1439 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1440 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1441 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 7.68688E-004 |
| 1442 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 1.56036E-006 |
| 1443 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 2.12418E-003 |
| 1444 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1445 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F3 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1446 | Coil:Heating:Water | CB_UTILITY_F3 ZN REHEAT COIL | Design Size Rated Capacity [W] | 71.33759 |
| 1447 | Coil:Heating:Water | CB_UTILITY_F3 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 1.56036E-006 |
| 1448 | Coil:Heating:Water | CB_UTILITY_F3 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 1.48420 |
| 1449 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Maximum Air Flow Rate [m3/s] | 1.63207E-002 |
| 1450 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Constant Minimum Air Flow Fraction | 0.38171 |
| 1451 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | User-Specified Constant Minimum Air Flow Fraction | 6.90000E-002 |
| 1452 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Minimum Air Flow Rate [m3/s] | 1.12613E-003 |
| 1453 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Maximum Flow Fraction during Reheat [] | 1.00000 |
| 1454 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | User-Specified Maximum Flow Fraction during Reheat [] | 0.50000 |
| 1455 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Maximum Flow per Zone Floor Area during Reheat [m3/s-m2] | 9.98151E-004 |
| 1456 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Maximum Reheat Water Flow Rate [m3/s] | 3.21422E-006 |
| 1457 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Air Volume Flow Rate [m3/s] | 4.34984E-003 |
| 1458 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Temperature [C] | 12.77778 |
| 1459 | AirTerminal:SingleDuct:VAV:Reheat | CB_UTILITY_F4 ZN VAV TERMINAL | Design Size Reheat Coil Sizing Inlet Air Humidity Ratio [kgWater/kgDryAir] | 8.00000E-003 |
| 1460 | Coil:Heating:Water | CB_UTILITY_F4 ZN REHEAT COIL | Design Size Rated Capacity [W] | 146.95007 |
| 1461 | Coil:Heating:Water | CB_UTILITY_F4 ZN REHEAT COIL | Design Size Maximum Water Flow Rate [m3/s] | 3.21422E-006 |
| 1462 | Coil:Heating:Water | CB_UTILITY_F4 ZN REHEAT COIL | Design Size U-Factor Times Area Value [W/K] | 3.06283 |
| 1463 | AirLoopHVAC | VAV_1 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.94211 |
| 1464 | AirLoopHVAC | VAV_1 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.35260 |
| 1465 | AirLoopHVAC | VAV_1 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 5.83466 |
| 1466 | AirLoopHVAC | VAV_1 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.52683 |
| 1467 | AirLoopHVAC | VAV_1 | Adjusted Cooling Design Air Flow Rate [m3/s] | 5.61359 |
| 1468 | AirLoopHVAC | VAV_1 | Adjusted Main Design Air Flow Rate [m3/s] | 5.61359 |
| 1469 | AirLoopHVAC | VAV_1 | User Heating Air Flow Ratio [] | 0.30000 |
| 1470 | AirLoopHVAC | VAV_1 | Calculated Heating Air Flow Ratio [] | 9.38494E-002 |
| 1471 | AirLoopHVAC | VAV_2 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.44993 |
| 1472 | AirLoopHVAC | VAV_2 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.20258 |
| 1473 | AirLoopHVAC | VAV_2 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 4.86830 |
| 1474 | AirLoopHVAC | VAV_2 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.63995 |
| 1475 | AirLoopHVAC | VAV_2 | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.79433 |
| 1476 | AirLoopHVAC | VAV_2 | Adjusted Main Design Air Flow Rate [m3/s] | 4.79433 |
| 1477 | AirLoopHVAC | VAV_2 | User Heating Air Flow Ratio [] | 0.30000 |
| 1478 | AirLoopHVAC | VAV_2 | Calculated Heating Air Flow Ratio [] | 0.13348 |
| 1479 | AirLoopHVAC | VAV_3 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 2.42734 |
| 1480 | AirLoopHVAC | VAV_3 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.20212 |
| 1481 | AirLoopHVAC | VAV_3 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 4.82319 |
| 1482 | AirLoopHVAC | VAV_3 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.73275 |
| 1483 | AirLoopHVAC | VAV_3 | Adjusted Cooling Design Air Flow Rate [m3/s] | 4.75031 |
| 1484 | AirLoopHVAC | VAV_3 | Adjusted Main Design Air Flow Rate [m3/s] | 4.75031 |
| 1485 | AirLoopHVAC | VAV_3 | User Heating Air Flow Ratio [] | 0.30000 |
| 1486 | AirLoopHVAC | VAV_3 | Calculated Heating Air Flow Ratio [] | 0.15425 |
| 1487 | AirLoopHVAC | VAV_4 | Sum of Air Terminal Maximum Heating Flow Rates [m3/s] | 3.60293 |
| 1488 | AirLoopHVAC | VAV_4 | Sum of Air Terminal Minimum Heating Flow Rates [m3/s] | 0.23108 |
| 1489 | AirLoopHVAC | VAV_4 | Sum of Air Terminal Maximum Flow Rates [m3/s] | 7.19225 |
| 1490 | AirLoopHVAC | VAV_4 | Adjusted Heating Design Air Flow Rate [m3/s] | 0.78384 |
| 1491 | AirLoopHVAC | VAV_4 | Adjusted Cooling Design Air Flow Rate [m3/s] | 7.02443 |
| 1492 | AirLoopHVAC | VAV_4 | Adjusted Main Design Air Flow Rate [m3/s] | 7.02443 |
| 1493 | AirLoopHVAC | VAV_4 | User Heating Air Flow Ratio [] | 0.30000 |
| 1494 | AirLoopHVAC | VAV_4 | Calculated Heating Air Flow Ratio [] | 0.11159 |
| 1495 | AirLoopHVAC | VAV_1 | Design Supply Air Flow Rate [m3/s] | 5.61359 |
| 1496 | AirLoopHVAC | VAV_2 | Design Supply Air Flow Rate [m3/s] | 4.79433 |
| 1497 | AirLoopHVAC | VAV_3 | Design Supply Air Flow Rate [m3/s] | 4.75031 |
| 1498 | AirLoopHVAC | VAV_4 | Design Supply Air Flow Rate [m3/s] | 7.02443 |
| 1499 | Controller:OutdoorAir | VAV_1 OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 5.61359 |
| 1500 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Inlet Air Temperature [C] | 24.37422 |
| 1501 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Inlet Water Temperature [C] | 6.66667 |
| 1502 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Outlet Air Temperature [C] | 10.90719 |
| 1503 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.54677E-003 |
| 1504 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
| 1505 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Coil Load [W] | 110731.59671 |
| 1506 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Water Flow Rate [m3/s] | 4.70145E-003 |
| 1507 | Coil:Cooling:Water | VAV_1 CLG COIL | Design Size Design Air Flow Rate [m3/s] | 5.61359 |
| 1508 | Coil:Heating:Water | VAV_1 MAIN HTG COIL | Design Size Rated Capacity [W] | 1836.25976 |
| 1509 | Coil:Heating:Water | VAV_1 MAIN HTG COIL | Design Size Maximum Water Flow Rate [m3/s] | 4.01642E-005 |
| 1510 | Coil:Heating:Water | VAV_1 MAIN HTG COIL | Design Size U-Factor Times Area Value [W/K] | 28.69425 |
| 1511 | Fan:VariableVolume | VAV_1 FAN | Design Size Maximum Flow Rate [m3/s] | 5.61359 |
| 1512 | Controller:WaterCoil | VAV_1 CLG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 4.70145E-003 |
| 1513 | Controller:WaterCoil | VAV_1 CLG COIL CONTROLLER | Controller Convergence Tolerance | 1.01286E-004 |
| 1514 | Controller:WaterCoil | VAV_1 MAIN HTG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 4.01642E-005 |
| 1515 | Controller:OutdoorAir | VAV_2 OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.79433 |
| 1516 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Inlet Air Temperature [C] | 24.17320 |
| 1517 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Inlet Water Temperature [C] | 6.66667 |
| 1518 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Outlet Air Temperature [C] | 10.89519 |
| 1519 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.59068E-003 |
| 1520 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
| 1521 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Coil Load [W] | 94101.46455 |
| 1522 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Water Flow Rate [m3/s] | 3.99537E-003 |
| 1523 | Coil:Cooling:Water | VAV_2 CLG COIL | Design Size Design Air Flow Rate [m3/s] | 4.79433 |
| 1524 | Coil:Heating:Water | VAV_2 MAIN HTG COIL | Design Size Rated Capacity [W] | 4167.51176 |
| 1525 | Coil:Heating:Water | VAV_2 MAIN HTG COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.11553E-005 |
| 1526 | Coil:Heating:Water | VAV_2 MAIN HTG COIL | Design Size U-Factor Times Area Value [W/K] | 64.72500 |
| 1527 | Fan:VariableVolume | VAV_2 FAN | Design Size Maximum Flow Rate [m3/s] | 4.79433 |
| 1528 | Controller:WaterCoil | VAV_2 CLG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 3.99537E-003 |
| 1529 | Controller:WaterCoil | VAV_2 CLG COIL CONTROLLER | Controller Convergence Tolerance | 1.19186E-004 |
| 1530 | Controller:WaterCoil | VAV_2 MAIN HTG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 9.11553E-005 |
| 1531 | Controller:OutdoorAir | VAV_3 OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 4.75031 |
| 1532 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Inlet Air Temperature [C] | 24.17584 |
| 1533 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Inlet Water Temperature [C] | 6.66667 |
| 1534 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Outlet Air Temperature [C] | 10.89525 |
| 1535 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.60807E-003 |
| 1536 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
| 1537 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Coil Load [W] | 93505.24839 |
| 1538 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Water Flow Rate [m3/s] | 3.97005E-003 |
| 1539 | Coil:Cooling:Water | VAV_3 CLG COIL | Design Size Design Air Flow Rate [m3/s] | 4.75031 |
| 1540 | Coil:Heating:Water | VAV_3 MAIN HTG COIL | Design Size Rated Capacity [W] | 4357.77485 |
| 1541 | Coil:Heating:Water | VAV_3 MAIN HTG COIL | Design Size Maximum Water Flow Rate [m3/s] | 9.53169E-005 |
| 1542 | Coil:Heating:Water | VAV_3 MAIN HTG COIL | Design Size U-Factor Times Area Value [W/K] | 67.64383 |
| 1543 | Fan:VariableVolume | VAV_3 FAN | Design Size Maximum Flow Rate [m3/s] | 4.75031 |
| 1544 | Controller:WaterCoil | VAV_3 CLG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 3.97005E-003 |
| 1545 | Controller:WaterCoil | VAV_3 CLG COIL CONTROLLER | Controller Convergence Tolerance | 1.19946E-004 |
| 1546 | Controller:WaterCoil | VAV_3 MAIN HTG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 9.53169E-005 |
| 1547 | Controller:OutdoorAir | VAV_4 OA CONTROLLER | Maximum Outdoor Air Flow Rate [m3/s] | 7.02443 |
| 1548 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Inlet Air Temperature [C] | 24.09675 |
| 1549 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Inlet Water Temperature [C] | 6.66667 |
| 1550 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Outlet Air Temperature [C] | 10.91803 |
| 1551 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Inlet Air Humidity Ratio [kgWater/kgDryAir] | 9.20791E-003 |
| 1552 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Outlet Air Humidity Ratio [kgWater/kgDryAir] | 8.50000E-003 |
| 1553 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Coil Load [W] | 128788.38239 |
| 1554 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Water Flow Rate [m3/s] | 5.46811E-003 |
| 1555 | Coil:Cooling:Water | VAV_4 CLG COIL | Design Size Design Air Flow Rate [m3/s] | 7.02443 |
| 1556 | Coil:Heating:Water | VAV_4 MAIN HTG COIL | Design Size Rated Capacity [W] | 3631.29969 |
| 1557 | Coil:Heating:Water | VAV_4 MAIN HTG COIL | Design Size Maximum Water Flow Rate [m3/s] | 7.94268E-005 |
| 1558 | Coil:Heating:Water | VAV_4 MAIN HTG COIL | Design Size U-Factor Times Area Value [W/K] | 56.62046 |
| 1559 | Fan:VariableVolume | VAV_4 FAN | Design Size Maximum Flow Rate [m3/s] | 7.02443 |
| 1560 | Controller:WaterCoil | VAV_4 CLG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 5.46811E-003 |
| 1561 | Controller:WaterCoil | VAV_4 CLG COIL CONTROLLER | Controller Convergence Tolerance | 8.70851E-005 |
| 1562 | Controller:WaterCoil | VAV_4 MAIN HTG COIL CONTROLLER | Maximum Actuated Flow [m3/s] | 7.94268E-005 |
| 1563 | Pump:VariableSpeed | CHILLED WATER LOOP SECONDARY PUMP | Initial Design Flow Rate [m3/s] | 1.81350E-002 |
| 1564 | Pump:VariableSpeed | CHILLED WATER LOOP SECONDARY PUMP | Initial Design Power Consumption [W] | 3456.17966 |
| 1565 | PlantLoop | CHILLED WATER LOOP | Initial Maximum Loop Flow Rate [m3/s] | 1.81350E-002 |
| 1566 | PlantLoop | CHILLED WATER LOOP | Initial Plant Loop Volume [m3] | 2.17620 |
| 1567 | Pump:ConstantSpeed | CHILLED WATER LOOP PRIMARY PUMP | Initial Design Flow Rate [m3/s] | 1.81350E-002 |
| 1568 | Pump:ConstantSpeed | CHILLED WATER LOOP PRIMARY PUMP | Initial Design Power Consumption [W] | 1192.01572 |
| 1569 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Initial Design Size Reference Chilled Water Flow Rate [m3/s] | 1.81350E-002 |
| 1570 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Initial Design Size Reference Capacity [W] | 427126.69203 |
| 1571 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Initial Design Size Reference Condenser Fluid Flow Rate [m3/s] | 2.15854E-002 |
| 1572 | PlantLoop | CONDENSER WATER LOOP | Initial Maximum Loop Flow Rate [m3/s] | 2.15854E-002 |
| 1573 | PlantLoop | CONDENSER WATER LOOP | Initial Plant Loop Volume [m3] | 2.59024 |
| 1574 | Pump:ConstantSpeed | CONDENSER WATER LOOP CONSTANT PUMP | Initial Design Flow Rate [m3/s] | 2.15854E-002 |
| 1575 | Pump:ConstantSpeed | CONDENSER WATER LOOP CONSTANT PUMP | Initial Design Power Consumption [W] | 4434.41433 |
| 1576 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Initial Design Water Flow Rate [m3/s] | 2.15854E-002 |
| 1577 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Initial Design Air Flow Rate [m3/s] | 36.45484 |
| 1578 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Initial Nominal Capacity [W] | 498252.51265 |
| 1579 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Initial Air Flow Rate in free convection regime [m3/s] | 7.29097 |
| 1580 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Initial Tower capacity in free convection regime at design conditions [W] | 62281.56408 |
| 1581 | PlantLoop | HOT WATER LOOP | Initial Maximum Loop Flow Rate [m3/s] | 2.03254E-003 |
| 1582 | PlantLoop | HOT WATER LOOP | Initial Plant Loop Volume [m3] | 0.24391 |
| 1583 | Pump:VariableSpeed | HOT WATER LOOP PUMP | Initial Design Flow Rate [m3/s] | 2.03254E-003 |
| 1584 | Pump:VariableSpeed | HOT WATER LOOP PUMP | Initial Design Power Consumption [W] | 534.39801 |
| 1585 | Boiler:HotWater | BOILER 551KBTU/HR 0.8 THERMAL EFF | Initial Design Size Nominal Capacity [W] | 92925.44072 |
| 1586 | Boiler:HotWater | BOILER 551KBTU/HR 0.8 THERMAL EFF | Initial Design Size Design Water Flow Rate [m3/s] | 2.03254E-003 |
| 1587 | PlantLoop | MAIN SERVICE WATER LOOP | Initial Maximum Loop Flow Rate [m3/s] | 3.65923E-005 |
| 1588 | PlantLoop | MAIN SERVICE WATER LOOP | Initial Plant Loop Volume [m3] | 4.39108E-003 |
| 1589 | Pump:ConstantSpeed | MAIN SERVICE WATER LOOP CIRCULATOR PUMP | Initial Design Flow Rate [m3/s] | 3.65923E-005 |
| 1590 | Pump:ConstantSpeed | MAIN SERVICE WATER LOOP CIRCULATOR PUMP | Initial Design Power Consumption [W] | 2.00326 |
| 1591 | WaterHeater:Mixed | 300GAL NATURAL GAS WATER HEATER - 300KBTU/HR 0.804 THERM EFF | Initial Use Side Design Flow Rate [m3/s] | 3.65923E-005 |
| 1592 | PlantLoop | CHILLED WATER LOOP | Maximum Loop Flow Rate [m3/s] | 1.81350E-002 |
| 1593 | PlantLoop | CHILLED WATER LOOP | Plant Loop Volume [m3] | 2.17620 |
| 1594 | PlantLoop | CONDENSER WATER LOOP | Maximum Loop Flow Rate [m3/s] | 2.48232E-002 |
| 1595 | PlantLoop | CONDENSER WATER LOOP | Plant Loop Volume [m3] | 2.97878 |
| 1596 | PlantLoop | HOT WATER LOOP | Maximum Loop Flow Rate [m3/s] | 2.03254E-003 |
| 1597 | PlantLoop | HOT WATER LOOP | Plant Loop Volume [m3] | 0.24391 |
| 1598 | PlantLoop | MAIN SERVICE WATER LOOP | Maximum Loop Flow Rate [m3/s] | 3.65923E-005 |
| 1599 | PlantLoop | MAIN SERVICE WATER LOOP | Plant Loop Volume [m3] | 4.39108E-003 |
| 1600 | Pump:VariableSpeed | CHILLED WATER LOOP SECONDARY PUMP | Design Flow Rate [m3/s] | 1.81350E-002 |
| 1601 | Pump:VariableSpeed | CHILLED WATER LOOP SECONDARY PUMP | Design Power Consumption [W] | 3456.17966 |
| 1602 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Design Size Reference Chilled Water Flow Rate [m3/s] | 1.81350E-002 |
| 1603 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Design Size Reference Capacity [W] | 427126.69203 |
| 1604 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Design Size Reference Condenser Fluid Flow Rate [m3/s] | 2.15854E-002 |
| 1605 | Pump:ConstantSpeed | CHILLED WATER LOOP PRIMARY PUMP | Design Flow Rate [m3/s] | 1.81350E-002 |
| 1606 | Pump:ConstantSpeed | CHILLED WATER LOOP PRIMARY PUMP | Design Power Consumption [W] | 1192.01572 |
| 1607 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Design Water Flow Rate [m3/s] | 2.48232E-002 |
| 1608 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Design Air Flow Rate [m3/s] | 36.45484 |
| 1609 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Nominal Capacity [W] | 572990.38955 |
| 1610 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Air Flow Rate in free convection regime [m3/s] | 7.29097 |
| 1611 | CoolingTower:VariableSpeed | CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | Tower capacity in free convection regime at design conditions [W] | 71623.79869 |
| 1612 | Pump:ConstantSpeed | CONDENSER WATER LOOP CONSTANT PUMP | Design Flow Rate [m3/s] | 2.48232E-002 |
| 1613 | Pump:ConstantSpeed | CONDENSER WATER LOOP CONSTANT PUMP | Design Power Consumption [W] | 5099.57648 |
| 1614 | Boiler:HotWater | BOILER 551KBTU/HR 0.8 THERMAL EFF | Design Size Nominal Capacity [W] | 92925.44072 |
| 1615 | Boiler:HotWater | BOILER 551KBTU/HR 0.8 THERMAL EFF | Design Size Design Water Flow Rate [m3/s] | 2.03254E-003 |
| 1616 | Pump:VariableSpeed | HOT WATER LOOP PUMP | Design Flow Rate [m3/s] | 2.03254E-003 |
| 1617 | Pump:VariableSpeed | HOT WATER LOOP PUMP | Design Power Consumption [W] | 534.39801 |
| 1618 | WaterHeater:Mixed | 300GAL NATURAL GAS WATER HEATER - 300KBTU/HR 0.804 THERM EFF | Use Side Design Flow Rate [m3/s] | 3.65923E-005 |
| 1619 | Pump:ConstantSpeed | MAIN SERVICE WATER LOOP CIRCULATOR PUMP | Design Flow Rate [m3/s] | 3.65923E-005 |
| 1620 | Pump:ConstantSpeed | MAIN SERVICE WATER LOOP CIRCULATOR PUMP | Design Power Consumption [W] | 2.00326 |
| Component Type | Name | Nominal Total Capacity {W} | |
| 1 | Coil:Heating:Water | CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | 45.38 |
| 2 | Coil:Heating:Water | CB_CLASSROOM_1_F2 ZN REHEAT COIL | 2195.70 |
| 3 | Coil:Heating:Water | CB_CLASSROOM_1_F3 ZN REHEAT COIL | 2334.67 |
| 4 | Coil:Heating:Water | CB_CLASSROOM_1_F4 ZN REHEAT COIL | 3304.41 |
| 5 | Coil:Heating:Water | CB_CLASSROOM_2_F2 ZN REHEAT COIL | 910.04 |
| 6 | Coil:Heating:Water | CB_CLASSROOM_2_F3 ZN REHEAT COIL | 984.20 |
| 7 | Coil:Heating:Water | CB_CLASSROOM_2_F4 ZN REHEAT COIL | 1805.74 |
| 8 | Coil:Heating:Water | CB_CLASSROOM_3_F2 ZN REHEAT COIL | 801.73 |
| 9 | Coil:Heating:Water | CB_CLASSROOM_3_F3 ZN REHEAT COIL | 850.23 |
| 10 | Coil:Heating:Water | CB_CLASSROOM_3_F4 ZN REHEAT COIL | 1716.05 |
| 11 | Coil:Heating:Water | CB_CLASSROOM_4_F2 ZN REHEAT COIL | 815.78 |
| 12 | Coil:Heating:Water | CB_CLASSROOM_4_F3 ZN REHEAT COIL | 887.72 |
| 13 | Coil:Heating:Water | CB_CLASSROOM_4_F4 ZN REHEAT COIL | 1841.59 |
| 14 | Coil:Heating:Water | CB_CLASSROOM_5_F2 ZN REHEAT COIL | 656.92 |
| 15 | Coil:Heating:Water | CB_CLASSROOM_5_F3 ZN REHEAT COIL | 782.07 |
| 16 | Coil:Heating:Water | CB_CLASSROOM_5_F4 ZN REHEAT COIL | 1825.67 |
| 17 | Coil:Heating:Water | CB_CLASSROOM_6_F2 ZN REHEAT COIL | 362.12 |
| 18 | Coil:Heating:Water | CB_CLASSROOM_6_F3 ZN REHEAT COIL | 788.81 |
| 19 | Coil:Heating:Water | CB_CLASSROOM_6_F4 ZN REHEAT COIL | 3347.67 |
| 20 | Coil:Heating:Water | CB_CLASSROOM_7_F2 ZN REHEAT COIL | 282.76 |
| 21 | Coil:Heating:Water | CB_CLASSROOM_7_F3 ZN REHEAT COIL | 908.41 |
| 22 | Coil:Heating:Water | CB_CLASSROOM_8_F2 ZN REHEAT COIL | 1503.54 |
| 23 | Coil:Heating:Water | CB_CLASSROOM_8_F3 ZN REHEAT COIL | 2236.03 |
| 24 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | 0.00 |
| 25 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | 0.00 |
| 26 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | 0.00 |
| 27 | Coil:Heating:Water | CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | 0.00 |
| 28 | Coil:Heating:Water | CB_CORRIDOR_1_F3 ZN REHEAT COIL | 532.19 |
| 29 | Coil:Heating:Water | CB_CORRIDOR_2_F3 ZN REHEAT COIL | 28.70 |
| 30 | Coil:Heating:Water | CB_CORRIDOR_F1 ZN REHEAT COIL | 182.12 |
| 31 | Coil:Heating:Water | CB_CORRIDOR_F2 ZN REHEAT COIL | 178.43 |
| 32 | Coil:Heating:Water | CB_CORRIDOR_F4 ZN REHEAT COIL | 1506.64 |
| 33 | Coil:Heating:Water | CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | 881.42 |
| 34 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | 365.17 |
| 35 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | 392.60 |
| 36 | Coil:Heating:Water | CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | 451.42 |
| 37 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | 377.17 |
| 38 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | 414.93 |
| 39 | Coil:Heating:Water | CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | 556.59 |
| 40 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | 377.86 |
| 41 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | 417.61 |
| 42 | Coil:Heating:Water | CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | 568.45 |
| 43 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | 377.48 |
| 44 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | 418.05 |
| 45 | Coil:Heating:Water | CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | 569.78 |
| 46 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | 377.38 |
| 47 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | 418.17 |
| 48 | Coil:Heating:Water | CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | 569.86 |
| 49 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | 377.93 |
| 50 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | 417.73 |
| 51 | Coil:Heating:Water | CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | 568.50 |
| 52 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | 375.73 |
| 53 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | 414.59 |
| 54 | Coil:Heating:Water | CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | 556.50 |
| 55 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | 359.68 |
| 56 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | 390.85 |
| 57 | Coil:Heating:Water | CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | 450.12 |
| 58 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | 0.00 |
| 59 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | 0.00 |
| 60 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | 0.00 |
| 61 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | 0.00 |
| 62 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | 0.00 |
| 63 | Coil:Heating:Water | CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | 0.00 |
| 64 | Coil:Heating:Water | CB_LAB_1_F4 ZN REHEAT COIL | 552.22 |
| 65 | Coil:Heating:Water | CB_LAB_2_F4 ZN REHEAT COIL | 24.96 |
| 66 | Coil:Heating:Water | CB_LAB_3_F4 ZN REHEAT COIL | 24.96 |
| 67 | Coil:Heating:Water | CB_LAB_4_F4 ZN REHEAT COIL | 626.52 |
| 68 | Coil:Heating:Water | CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | 2957.37 |
| 69 | Coil:Heating:Water | CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | 3102.31 |
| 70 | Coil:Heating:Water | CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | 2312.88 |
| 71 | Coil:Heating:Water | CB_MAIN_STAIRS_F1 ZN REHEAT COIL | 388.98 |
| 72 | Coil:Heating:Water | CB_MAIN_STAIRS_F2 ZN REHEAT COIL | 445.02 |
| 73 | Coil:Heating:Water | CB_MAIN_STAIRS_F3 ZN REHEAT COIL | 532.14 |
| 74 | Coil:Heating:Water | CB_MAIN_STAIRS_F4 ZN REHEAT COIL | 663.51 |
| 75 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | 311.84 |
| 76 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | 319.30 |
| 77 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | 320.05 |
| 78 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | 320.15 |
| 79 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | 320.06 |
| 80 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | 319.82 |
| 81 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | 318.33 |
| 82 | Coil:Heating:Water | CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | 303.86 |
| 83 | Coil:Heating:Water | CB_OFFICES_OPEN_F1 ZN REHEAT COIL | 0.00 |
| 84 | Coil:Heating:Water | CB_OFFICES_OPEN_F2 ZN REHEAT COIL | 0.00 |
| 85 | Coil:Heating:Water | CB_OFFICES_OPEN_F3 ZN REHEAT COIL | 0.00 |
| 86 | Coil:Heating:Water | CB_OFFICES_OPEN_F4 ZN REHEAT COIL | 0.00 |
| 87 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | 26.29 |
| 88 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | 363.24 |
| 89 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | 427.84 |
| 90 | Coil:Heating:Water | CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | 521.06 |
| 91 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | 361.11 |
| 92 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | 430.15 |
| 93 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | 445.12 |
| 94 | Coil:Heating:Water | CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | 532.23 |
| 95 | Coil:Heating:Water | CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | 0.00 |
| 96 | Coil:Heating:Water | CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | 0.00 |
| 97 | Coil:Heating:Water | CB_STORAGE_F1 ZN REHEAT COIL | 564.94 |
| 98 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | 0.00 |
| 99 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | 0.00 |
| 100 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | 0.00 |
| 101 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | 0.00 |
| 102 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | 0.00 |
| 103 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | 0.00 |
| 104 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | 0.00 |
| 105 | Coil:Heating:Water | CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | 6.69 |
| 106 | Coil:Heating:Water | CB_STUDIO_1_F2 ZN REHEAT COIL | 2617.54 |
| 107 | Coil:Heating:Water | CB_STUDIO_1_F3 ZN REHEAT COIL | 2922.46 |
| 108 | Coil:Heating:Water | CB_STUDIO_2_F2 ZN REHEAT COIL | 3181.27 |
| 109 | Coil:Heating:Water | CB_STUDIO_2_F3 ZN REHEAT COIL | 2729.52 |
| 110 | Coil:Heating:Water | CB_UTILITY_F1 ZN REHEAT COIL | 29.18 |
| 111 | Coil:Heating:Water | CB_UTILITY_F2 ZN REHEAT COIL | 43.13 |
| 112 | Coil:Heating:Water | CB_UTILITY_F3 ZN REHEAT COIL | 67.45 |
| 113 | Coil:Heating:Water | CB_UTILITY_F4 ZN REHEAT COIL | 138.93 |
| 114 | Coil:Heating:Water | VAV_1 MAIN HTG COIL | 1714.72 |
| 115 | Coil:Heating:Water | VAV_2 MAIN HTG COIL | 3810.34 |
| 116 | Coil:Heating:Water | VAV_3 MAIN HTG COIL | 3976.92 |
| 117 | Coil:Heating:Water | VAV_4 MAIN HTG COIL | 3365.78 |
| Component Type | Name | Nominal Total Capacity {W} | Nominal Sensible Capacity {W} | Nominal Latent Capacity {W} | Nominal Sensible Heat Ratio | Nominal Coil UA Value {W/C} | Nominal Coil Surface Area {m2} | |
| 1 | Coil:Cooling:Water | VAV_1 CLG COIL | 135114.39 | 94979.12 | 40135.27 | 0.70 | 14097.27 | 142.98 |
| 2 | Coil:Cooling:Water | VAV_2 CLG COIL | 115284.02 | 81080.24 | 34203.78 | 0.70 | 12055.28 | 122.27 |
| 3 | Coil:Cooling:Water | VAV_3 CLG COIL | 114382.59 | 80409.87 | 33972.72 | 0.70 | 11961.27 | 121.32 |
| 4 | Coil:Cooling:Water | VAV_4 CLG COIL | 163314.48 | 116149.84 | 47164.64 | 0.71 | 17072.45 | 173.16 |
| Environment Name | Environment Type | Start Date | End Date | Start DayOfWeek | Duration {#days} | Source:Start DayOfWeek | Use Daylight Saving | Use Holidays | Apply Weekend Holiday Rule | Use Rain Values | Use Snow Values | Sky Temperature Model | |
| 1 | RUN PERIOD 1 | WeatherFileRunPeriod | 01/01/2006 | 12/31/2006 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
| 2 | RUN PERIOD 1 | WeatherFileRunPeriod | 01/01/2006 | 12/31/2006 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
| 3 | RUN PERIOD 1 | WeatherFileRunPeriod | 01/01/2006 | 12/31/2006 | Sunday | 365 | Use RunPeriod Specified Day | No | No | No | Yes | Yes | Clark and Allen |
| Daylight Saving Indicator | Source | Start Date | End Date | |
| 1 | Yes | InputFile | 03/12 | 11/05 |
| 2 | Yes | InputFile | 03/12 | 11/05 |
| NumberofWarmupDays | |
| 1 | 6 |
| 2 | 13 |
| 3 | 13 |
| Max Dry-Bulb Temp {C} | Temp Range {dC} | Temp Range Ind Type | Hum Ind Type | Hum Ind Value at Max Temp | Hum Ind Units | Pressure {Pa} | Wind Direction {deg CW from N} | Wind Speed {m/s} | Clearness | Rain | Snow | |
| 1 | 33.90 | 7.90 | DefaultMultipliers | Wetbulb | 25.10 | {C} | 101229 | 270 | 3.1 | 0.00 | No | No |
| 2 | 4.60 | 0.00 | DefaultMultipliers | Wetbulb | 4.60 | {C} | 101229 | 10 | 2.5 | 0.00 | No | No |
| 3 | 33.90 | 7.90 | DefaultMultipliers | Wetbulb | 25.10 | {C} | 101229 | 270 | 3.1 | 0.00 | No | No |
| 4 | 4.60 | 0.00 | DefaultMultipliers | Wetbulb | 4.60 | {C} | 101229 | 10 | 2.5 | 0.00 | No | No |
| 5 | 33.90 | 7.90 | DefaultMultipliers | Wetbulb | 25.10 | {C} | 101229 | 270 | 3.1 | 0.00 | No | No |
| 6 | 4.60 | 0.00 | DefaultMultipliers | Wetbulb | 4.60 | {C} | 101229 | 10 | 2.5 | 0.00 | No | No |
| DayOfYear | ASHRAE A Coeff | ASHRAE B Coeff | ASHRAE C Coeff | Solar Constant-Annual Variation | Eq of Time {minutes} | Solar Declination Angle {deg} | Solar Model | |
| 1 | 233 | 1106.3 | 0.2000 | 0.1216 | 1.0 | -3.33 | 12.4 | ASHRAETau |
| 2 | 21 | 1229.0 | 0.1415 | 5.7310E-002 | 1.0 | -11.15 | -20.1 | ASHRAEClearSky |
| 3 | 233 | 1106.3 | 0.2000 | 0.1216 | 1.0 | -3.33 | 12.4 | ASHRAETau |
| 4 | 21 | 1229.0 | 0.1415 | 5.7310E-002 | 1.0 | -11.15 | -20.1 | ASHRAEClearSky |
| 5 | 233 | 1106.3 | 0.2000 | 0.1216 | 1.0 | -3.33 | 12.4 | ASHRAETau |
| 6 | 21 | 1229.0 | 0.1415 | 5.7310E-002 | 1.0 | -11.15 | -20.1 | ASHRAEClearSky |
| Style | Unit Conversion | |
| 1 | HTML | None |
| Zone Name | Environment Type/Name | Average Warmup Temperature Difference {deltaC} | Std Dev Warmup Temperature Difference {deltaC} | Max Temperature Pass/Fail Convergence | Min Temperature Pass/Fail Convergence | Average Warmup Load Difference {W} | Std Dev Warmup Load Difference {W} | Heating Load Pass/Fail Convergence | Cooling Load Pass/Fail Convergence | |
| 1 | CB_CAFE_STUDY_LOUNGE_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.3078302924 | 0.6311419405 | Pass | Pass | 0.2329385351 | 0.4193874891 | Pass | Pass |
| 2 | CB_CLASSROOM_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1171259609 | 0.2382838875 | Pass | Pass | 0.2568250391 | 0.4584748516 | Pass | Pass |
| 3 | CB_CLASSROOM_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1194893124 | 0.2414713418 | Pass | Pass | 0.2572384771 | 0.4582300787 | Pass | Pass |
| 4 | CB_CLASSROOM_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1102457549 | 0.2240869595 | Pass | Pass | 0.2553890433 | 0.4482531321 | Pass | Pass |
| 5 | CB_CLASSROOM_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.9291144592E-002 | 0.2024338657 | Pass | Pass | 0.2600609515 | 0.4683801668 | Pass | Pass |
| 6 | CB_CLASSROOM_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.8777821230E-002 | 0.2002365580 | Pass | Pass | 0.2588448519 | 0.4632677740 | Pass | Pass |
| 7 | CB_CLASSROOM_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.8620599252E-002 | 0.1790439665 | Pass | Pass | 0.2530010920 | 0.4457118105 | Pass | Pass |
| 8 | CB_CLASSROOM_3_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1033794604 | 0.2095825857 | Pass | Pass | 0.2539811817 | 0.4523623177 | Pass | Pass |
| 9 | CB_CLASSROOM_3_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.5372284166E-002 | 0.1935110688 | Pass | Pass | 0.2624747505 | 0.4725435708 | Pass | Pass |
| 10 | CB_CLASSROOM_3_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.4557664018E-002 | 0.1707744601 | Pass | Pass | 0.2520349252 | 0.4434726388 | Pass | Pass |
| 11 | CB_CLASSROOM_4_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1453643629 | 0.2923422495 | Pass | Pass | 0.2444685252 | 0.4354445899 | Pass | Pass |
| 12 | CB_CLASSROOM_4_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1000630169 | 0.2018772535 | Pass | Pass | 0.2498084838 | 0.4402973685 | Pass | Pass |
| 13 | CB_CLASSROOM_4_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.7804208970E-002 | 0.1774041874 | Pass | Pass | 0.2524869389 | 0.4445887946 | Pass | Pass |
| 14 | CB_CLASSROOM_5_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.7512516464E-002 | 0.1790446188 | Pass | Pass | 0.2549484693 | 0.4539471480 | Pass | Pass |
| 15 | CB_CLASSROOM_5_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.7782711244E-002 | 0.1783334297 | Pass | Pass | 0.2550901362 | 0.4531566440 | Pass | Pass |
| 16 | CB_CLASSROOM_5_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.8340473965E-002 | 0.1784107341 | Pass | Pass | 0.2537762533 | 0.4477581676 | Pass | Pass |
| 17 | CB_CLASSROOM_6_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1047193228 | 0.2123593388 | Pass | Pass | 0.2547473388 | 0.4547586898 | Pass | Pass |
| 18 | CB_CLASSROOM_6_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.4861288638E-002 | 0.1923892520 | Pass | Pass | 0.2574775757 | 0.4592730684 | Pass | Pass |
| 19 | CB_CLASSROOM_6_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1023885657 | 0.2076622539 | Pass | Pass | 0.2531748195 | 0.4457508423 | Pass | Pass |
| 20 | CB_CLASSROOM_7_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1157704123 | 0.2342587563 | Pass | Pass | 0.2524497532 | 0.4499688035 | Pass | Pass |
| 21 | CB_CLASSROOM_7_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1016030496 | 0.2055729945 | Pass | Pass | 0.2561099858 | 0.4559342615 | Pass | Pass |
| 22 | CB_CLASSROOM_8_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1406470422 | 0.2876405350 | Pass | Pass | 0.2526266216 | 0.4461202795 | Pass | Pass |
| 23 | CB_CLASSROOM_8_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1318432839 | 0.2667530102 | Pass | Pass | 0.2570154437 | 0.4546595436 | Pass | Pass |
| 24 | CB_CONFERENCE_ROOM_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.2402897369 | 0.4035385429 | Pass | Pass | 0.1936699693 | 0.3841864462 | Pass | Pass |
| 25 | CB_CONFERENCE_ROOM_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.2433724914 | 0.3930781447 | Pass | Pass | 0.1941166400 | 0.3789503451 | Pass | Pass |
| 26 | CB_CONFERENCE_ROOM_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.2455406911 | 0.3928207450 | Pass | Pass | 0.1945197518 | 0.3783901868 | Pass | Pass |
| 27 | CB_CONFERENCE_ROOM_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.2419599257 | 0.3830425206 | Pass | Pass | 0.1959531692 | 0.3770808013 | Pass | Pass |
| 28 | CB_CORRIDOR_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 6.5267442549E-002 | 0.1301587001 | Pass | Pass | 0.2467705708 | 0.4472672548 | Pass | Pass |
| 29 | CB_CORRIDOR_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.8574656979E-002 | 9.6528720503E-002 | Pass | Pass | 0.2284158185 | 0.4063558537 | Pass | Pass |
| 30 | CB_CORRIDOR_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1698088516 | 0.3227813583 | Pass | Pass | 0.2211738728 | 0.4275127590 | Pass | Pass |
| 31 | CB_CORRIDOR_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 7.9026167659E-002 | 0.1523460909 | Pass | Pass | 0.2296950328 | 0.4089264533 | Pass | Pass |
| 32 | CB_CORRIDOR_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.5396088443E-002 | 0.1126842512 | Pass | Pass | 0.2321064007 | 0.3979370042 | Pass | Pass |
| 33 | CB_ENTRANCE_LOBBY_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 7.1808240339E-002 | 0.1471159587 | Pass | Pass | 0.2257496303 | 0.4018605231 | Pass | Pass |
| 34 | CB_FACULTY_OFFICE_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1084049855 | 0.2214071201 | Pass | Pass | 0.2600555375 | 0.4721367109 | Pass | Pass |
| 35 | CB_FACULTY_OFFICE_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1113718956 | 0.2257665420 | Pass | Pass | 0.2640021597 | 0.4806128124 | Pass | Pass |
| 36 | CB_FACULTY_OFFICE_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1102896584 | 0.2215953972 | Pass | Pass | 0.2569956928 | 0.4567498994 | Pass | Pass |
| 37 | CB_FACULTY_OFFICE_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1068129083 | 0.2180155541 | Pass | Pass | 0.2566831639 | 0.4626117890 | Pass | Pass |
| 38 | CB_FACULTY_OFFICE_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1089799612 | 0.2207946055 | Pass | Pass | 0.2592751659 | 0.4673651869 | Pass | Pass |
| 39 | CB_FACULTY_OFFICE_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1028386123 | 0.2063681217 | Pass | Pass | 0.2513923686 | 0.4421423842 | Pass | Pass |
| 40 | CB_FACULTY_OFFICE_3_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1066058372 | 0.2175843942 | Pass | Pass | 0.2565086710 | 0.4621407511 | Pass | Pass |
| 41 | CB_FACULTY_OFFICE_3_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1086877991 | 0.2201852105 | Pass | Pass | 0.2589939989 | 0.4665304225 | Pass | Pass |
| 42 | CB_FACULTY_OFFICE_3_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1019415856 | 0.2046388512 | Pass | Pass | 0.2505024583 | 0.4397600036 | Pass | Pass |
| 43 | CB_FACULTY_OFFICE_4_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1065582724 | 0.2174929155 | Pass | Pass | 0.2565087226 | 0.4621465060 | Pass | Pass |
| 44 | CB_FACULTY_OFFICE_4_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1086553291 | 0.2201139443 | Pass | Pass | 0.2589938249 | 0.4665164365 | Pass | Pass |
| 45 | CB_FACULTY_OFFICE_4_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1018424911 | 0.2044473750 | Pass | Pass | 0.2504287902 | 0.4395627850 | Pass | Pass |
| 46 | CB_FACULTY_OFFICE_5_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1065546845 | 0.2174870136 | Pass | Pass | 0.2565138342 | 0.4621612613 | Pass | Pass |
| 47 | CB_FACULTY_OFFICE_5_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1086624527 | 0.2201257974 | Pass | Pass | 0.2590024541 | 0.4665367932 | Pass | Pass |
| 48 | CB_FACULTY_OFFICE_5_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1018457498 | 0.2044537202 | Pass | Pass | 0.2504302672 | 0.4395665522 | Pass | Pass |
| 49 | CB_FACULTY_OFFICE_6_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1066135158 | 0.2175981119 | Pass | Pass | 0.2565065195 | 0.4621329382 | Pass | Pass |
| 50 | CB_FACULTY_OFFICE_6_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1087008460 | 0.2202095933 | Pass | Pass | 0.2589975737 | 0.4665386755 | Pass | Pass |
| 51 | CB_FACULTY_OFFICE_6_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1019457331 | 0.2046471912 | Pass | Pass | 0.2505040678 | 0.4397644498 | Pass | Pass |
| 52 | CB_FACULTY_OFFICE_7_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1068070339 | 0.2180204856 | Pass | Pass | 0.2567752759 | 0.4628640429 | Pass | Pass |
| 53 | CB_FACULTY_OFFICE_7_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1090173475 | 0.2208761111 | Pass | Pass | 0.2593528941 | 0.4675779936 | Pass | Pass |
| 54 | CB_FACULTY_OFFICE_7_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1028419137 | 0.2063769919 | Pass | Pass | 0.2513817517 | 0.4421114535 | Pass | Pass |
| 55 | CB_FACULTY_OFFICE_8_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1088643309 | 0.2223675862 | Pass | Pass | 0.2610788131 | 0.4749544238 | Pass | Pass |
| 56 | CB_FACULTY_OFFICE_8_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1118955053 | 0.2268475173 | Pass | Pass | 0.2649923810 | 0.4832894723 | Pass | Pass |
| 57 | CB_FACULTY_OFFICE_8_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1103002643 | 0.2215984548 | Pass | Pass | 0.2570647508 | 0.4569150371 | Pass | Pass |
| 58 | CB_FACULTY_RESTROOMS_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.7070871895E-002 | 9.4647159720E-002 | Pass | Pass | 0.2428168769 | 0.4408071483 | Pass | Pass |
| 59 | CB_FACULTY_RESTROOMS_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.3543924487E-002 | 8.6900229259E-002 | Pass | Pass | 0.2463008292 | 0.4471940213 | Pass | Pass |
| 60 | CB_FACULTY_RESTROOMS_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.4433284419E-002 | 8.9965100119E-002 | Pass | Pass | 0.2506102851 | 0.4421394493 | Pass | Pass |
| 61 | CB_FACULTY_RESTROOMS_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.4672042704E-002 | 8.9916761544E-002 | Pass | Pass | 0.2453343979 | 0.4461524498 | Pass | Pass |
| 62 | CB_FACULTY_RESTROOMS_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.5365924313E-002 | 9.0410584511E-002 | Pass | Pass | 0.2424112687 | 0.4370599453 | Pass | Pass |
| 63 | CB_FACULTY_RESTROOMS_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.3500975551E-002 | 8.8092649472E-002 | Pass | Pass | 0.2511978239 | 0.4441232057 | Pass | Pass |
| 64 | CB_LAB_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.2093190702 | 0.4237793020 | Pass | Pass | 0.2353835660 | 0.4097969047 | Pass | Pass |
| 65 | CB_LAB_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1890892906 | 0.3801109714 | Pass | Pass | 0.2217311287 | 0.3862303780 | Pass | Pass |
| 66 | CB_LAB_3_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1903090618 | 0.3825205918 | Pass | Pass | 0.2223697334 | 0.3873204177 | Pass | Pass |
| 67 | CB_LAB_4_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.2028206875 | 0.4097279917 | Pass | Pass | 0.2308298800 | 0.4012354958 | Pass | Pass |
| 68 | CB_LECTURE_ROOM_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1033653297 | 0.2144317260 | Pass | Pass | 0.2424105605 | 0.4326092032 | Pass | Pass |
| 69 | CB_LECTURE_ROOM_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1158937196 | 0.2401000722 | Pass | Pass | 0.2447997756 | 0.4358669950 | Pass | Pass |
| 70 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1082119909 | 0.2282931176 | Pass | Pass | 0.2488082089 | 0.4566455760 | Pass | Pass |
| 71 | CB_MAIN_STAIRS_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 7.3443653494E-002 | 0.1499456529 | Pass | Pass | 0.2312188213 | 0.4148719327 | Pass | Pass |
| 72 | CB_MAIN_STAIRS_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.6158123400E-002 | 0.1139278166 | Pass | Pass | 0.2372864663 | 0.4196536281 | Pass | Pass |
| 73 | CB_MAIN_STAIRS_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.4519885773E-002 | 0.1100604944 | Pass | Pass | 0.2426544621 | 0.4299508173 | Pass | Pass |
| 74 | CB_MAIN_STAIRS_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.1062689843E-002 | 0.1034064372 | Pass | Pass | 0.2535170102 | 0.4464049467 | Pass | Pass |
| 75 | CB_OFFICES_ENCLOSED_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1135071112 | 0.2369200334 | Pass | Pass | 0.2582870597 | 0.4741651072 | Pass | Pass |
| 76 | CB_OFFICES_ENCLOSED_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1111751478 | 0.2323698203 | Pass | Pass | 0.2543877218 | 0.4630419756 | Pass | Pass |
| 77 | CB_OFFICES_ENCLOSED_3_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1109207384 | 0.2318739851 | Pass | Pass | 0.2541166822 | 0.4622849356 | Pass | Pass |
| 78 | CB_OFFICES_ENCLOSED_4_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1108897845 | 0.2318142100 | Pass | Pass | 0.2540901235 | 0.4622107255 | Pass | Pass |
| 79 | CB_OFFICES_ENCLOSED_5_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1108847508 | 0.2318024781 | Pass | Pass | 0.2540885228 | 0.4622078249 | Pass | Pass |
| 80 | CB_OFFICES_ENCLOSED_6_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1109096042 | 0.2318478538 | Pass | Pass | 0.2541083147 | 0.4622658131 | Pass | Pass |
| 81 | CB_OFFICES_ENCLOSED_7_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1111339948 | 0.2322727062 | Pass | Pass | 0.2543567892 | 0.4629663836 | Pass | Pass |
| 82 | CB_OFFICES_ENCLOSED_8_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1134173151 | 0.2366428997 | Pass | Pass | 0.2585761436 | 0.4750757826 | Pass | Pass |
| 83 | CB_OFFICES_OPEN_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 6.8370683981E-002 | 0.1439140433 | Pass | Pass | 0.2569601741 | 0.4823309352 | Pass | Pass |
| 84 | CB_OFFICES_OPEN_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 6.6656917076E-002 | 0.1371825558 | Pass | Pass | 0.2610549771 | 0.4884228594 | Pass | Pass |
| 85 | CB_OFFICES_OPEN_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 6.8441869226E-002 | 0.1394950954 | Pass | Pass | 0.2583917591 | 0.4820683184 | Pass | Pass |
| 86 | CB_OFFICES_OPEN_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 6.5854351726E-002 | 0.1340456632 | Pass | Pass | 0.2397715947 | 0.4183456289 | Pass | Pass |
| 87 | CB_PUBLIC_ELEVATORS_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 7.6109153781E-002 | 0.1118901848 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 88 | CB_PUBLIC_ELEVATORS_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 3.1303019804E-002 | 2.3222775698E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 89 | CB_PUBLIC_ELEVATORS_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 2.4727933211E-002 | 1.0889461521E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 90 | CB_PUBLIC_ELEVATORS_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 3.9802104290E-002 | 2.7693054882E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 91 | CB_SECONDARY_STAIRS_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1261956196 | 0.2617118666 | Pass | Pass | 0.2539220434 | 0.4591252737 | Pass | Pass |
| 92 | CB_SECONDARY_STAIRS_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.5664575018E-002 | 0.1949987900 | Pass | Pass | 0.2539563741 | 0.4479754550 | Pass | Pass |
| 93 | CB_SECONDARY_STAIRS_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.6008875987E-002 | 0.1939628530 | Pass | Pass | 0.2559296946 | 0.4509987275 | Pass | Pass |
| 94 | CB_SECONDARY_STAIRS_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.1591856407E-002 | 0.1857164665 | Pass | Pass | 0.2527635298 | 0.4348339345 | Pass | Pass |
| 95 | CB_SECONDARY_STAIRS_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.7100360377E-002 | 0.1819168520 | Pass | Pass | 0.2490469825 | 0.4453826729 | Pass | Pass |
| 96 | CB_SECONDARY_STAIRS_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.1058515849E-002 | 0.1642903833 | Pass | Pass | 0.2513163998 | 0.4438134047 | Pass | Pass |
| 97 | CB_SECONDARY_STAIRS_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.4039410273E-002 | 0.1694003756 | Pass | Pass | 0.2522050648 | 0.4448288378 | Pass | Pass |
| 98 | CB_SECONDARY_STAIRS_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 8.2276180071E-002 | 0.1660899093 | Pass | Pass | 0.2499407901 | 0.4337856705 | Pass | Pass |
| 99 | CB_STAFF_RESTROOMS_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.6768956651E-002 | 9.6966961760E-002 | Pass | Pass | 0.2603160672 | 0.4941846279 | Pass | Pass |
| 100 | CB_STAFF_RESTROOMS_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.9442409346E-002 | 0.1186350977 | Pass | Pass | 0.2340947325 | 0.4233398648 | Pass | Pass |
| 101 | CB_STORAGE_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.3638305924 | 0.6871522475 | Pass | Pass | 0.2028576347 | 0.4017068639 | Pass | Pass |
| 102 | CB_STUDENTS_RESTROOMS_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.1455423056E-002 | 0.1040243177 | Pass | Pass | 0.2526000007 | 0.4712505576 | Pass | Pass |
| 103 | CB_STUDENTS_RESTROOMS_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.3867606655E-002 | 8.8715068443E-002 | Pass | Pass | 0.2535900843 | 0.4692400407 | Pass | Pass |
| 104 | CB_STUDENTS_RESTROOMS_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.2295193403E-002 | 8.4854198056E-002 | Pass | Pass | 0.2585242501 | 0.4803608110 | Pass | Pass |
| 105 | CB_STUDENTS_RESTROOMS_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 4.2365159748E-002 | 8.5816056012E-002 | Pass | Pass | 0.2547420966 | 0.4540538375 | Pass | Pass |
| 106 | CB_STUDENTS_RESTROOMS_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.9572893515E-002 | 0.1195343362 | Pass | Pass | 0.2394907600 | 0.4362756289 | Pass | Pass |
| 107 | CB_STUDENTS_RESTROOMS_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.1649583746E-002 | 0.1034473342 | Pass | Pass | 0.2427710504 | 0.4402359982 | Pass | Pass |
| 108 | CB_STUDENTS_RESTROOMS_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.1108677826E-002 | 0.1018805576 | Pass | Pass | 0.2479237913 | 0.4518714872 | Pass | Pass |
| 109 | CB_STUDENTS_RESTROOMS_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.4291749860E-002 | 0.1096124677 | Pass | Pass | 0.2403848807 | 0.4180509634 | Pass | Pass |
| 110 | CB_STUDIO_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1001370962 | 0.2026310370 | Pass | Pass | 0.2403725961 | 0.4221336169 | Pass | Pass |
| 111 | CB_STUDIO_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1023066358 | 0.2045914427 | Pass | Pass | 0.2411282957 | 0.4260754231 | Pass | Pass |
| 112 | CB_STUDIO_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 9.6161935193E-002 | 0.1941242006 | Pass | Pass | 0.2402697955 | 0.4245263089 | Pass | Pass |
| 113 | CB_STUDIO_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1055357082 | 0.2119586186 | Pass | Pass | 0.2421273933 | 0.4245907050 | Pass | Pass |
| 114 | CB_UTILITY_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.8466842899 | 1.6167037640 | Pass | Pass | 0.1833975834 | 0.3798069182 | Pass | Pass |
| 115 | CB_UTILITY_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 0.1909403801 | 0.3549019140 | Pass | Pass | 0.2023342413 | 0.3683946153 | Pass | Pass |
| 116 | CB_UTILITY_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 7.7802005494E-002 | 0.1503734136 | Pass | Pass | 0.2411731827 | 0.4372506947 | Pass | Pass |
| 117 | CB_UTILITY_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 5.7567360034E-002 | 0.1173295600 | Pass | Pass | 0.2557580691 | 0.4553768927 | Pass | Pass |
| 118 | CB_CAFE_STUDY_LOUNGE_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 9.0617625132E-003 | 1.5154762810E-002 | Pass | Pass | 0.1597208119 | 0.3658426177 | Pass | Pass |
| 119 | CB_CLASSROOM_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1769751409 | 0.3410320046 | Pass | Pass | 0.3312424744 | 1.1386898633 | Pass | Pass |
| 120 | CB_CLASSROOM_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1864920799 | 0.3598555253 | Pass | Pass | 0.3336856490 | 1.1868576848 | Pass | Pass |
| 121 | CB_CLASSROOM_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1951907245 | 0.3744094235 | Pass | Pass | 0.3016510365 | 0.9765043307 | Pass | Pass |
| 122 | CB_CLASSROOM_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.4503351196E-002 | 0.1485591894 | Pass | Pass | 0.2089336863 | 0.4655622783 | Pass | Pass |
| 123 | CB_CLASSROOM_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.9403214695E-002 | 0.1612834557 | Pass | Pass | 0.3416408734 | 1.0614462602 | Pass | Pass |
| 124 | CB_CLASSROOM_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1168769369 | 0.2143527049 | Pass | Pass | 0.3125689475 | 0.9367404013 | Pass | Pass |
| 125 | CB_CLASSROOM_3_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.5486429314E-002 | 0.1380486373 | Pass | Pass | 0.1707362196 | 0.3708425814 | Pass | Pass |
| 126 | CB_CLASSROOM_3_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.4776652892E-002 | 0.1443010933 | Pass | Pass | 0.2042292637 | 0.4514632555 | Pass | Pass |
| 127 | CB_CLASSROOM_3_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1137087458 | 0.2074934812 | Pass | Pass | 0.3299913154 | 1.0202814263 | Pass | Pass |
| 128 | CB_CLASSROOM_4_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.7808662226E-002 | 0.1439259824 | Pass | Pass | 0.1695334111 | 0.3725972699 | Pass | Pass |
| 129 | CB_CLASSROOM_4_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 9.9138550940E-002 | 0.1637438001 | Pass | Pass | 0.1716267607 | 0.3676928192 | Pass | Pass |
| 130 | CB_CLASSROOM_4_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1206962800 | 0.2218575543 | Pass | Pass | 0.3260110491 | 1.0178704532 | Pass | Pass |
| 131 | CB_CLASSROOM_5_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.8870888016E-002 | 0.1102256718 | Pass | Pass | 0.1699065203 | 0.3731820786 | Pass | Pass |
| 132 | CB_CLASSROOM_5_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.7101075065E-002 | 0.1385264196 | Pass | Pass | 0.1713803399 | 0.3691702798 | Pass | Pass |
| 133 | CB_CLASSROOM_5_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1163060935 | 0.2143172257 | Pass | Pass | 0.3025601732 | 0.8874352948 | Pass | Pass |
| 134 | CB_CLASSROOM_6_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 9.0033476510E-003 | 1.3890686549E-002 | Pass | Pass | 2.1951711818 | 10.9334415745 | Pass | Pass |
| 135 | CB_CLASSROOM_6_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.7276285833E-002 | 0.1385142775 | Pass | Pass | 0.1764199279 | 0.3715030392 | Pass | Pass |
| 136 | CB_CLASSROOM_6_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1965155528 | 0.3763926551 | Pass | Pass | 0.3127644023 | 1.0877471749 | Pass | Pass |
| 137 | CB_CLASSROOM_7_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.5566119795E-002 | 4.3769734244E-002 | Pass | Pass | 0.1616679729 | 0.3441004785 | Pass | Pass |
| 138 | CB_CLASSROOM_7_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 9.7590405284E-002 | 0.1629043778 | Pass | Pass | 0.1780639532 | 0.3731434660 | Pass | Pass |
| 139 | CB_CLASSROOM_8_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1453410911 | 0.2630761163 | Pass | Pass | 0.2955127703 | 0.8363965117 | Pass | Pass |
| 140 | CB_CLASSROOM_8_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1834880794 | 0.3525982011 | Pass | Pass | 0.3428232281 | 1.1928440055 | Pass | Pass |
| 141 | CB_CONFERENCE_ROOM_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1218382435 | 0.2114238128 | Pass | Pass | 0.1666975224 | 0.3663123417 | Pass | Pass |
| 142 | CB_CONFERENCE_ROOM_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1220930179 | 0.2162724121 | Pass | Pass | 0.1663321382 | 0.3638439918 | Pass | Pass |
| 143 | CB_CONFERENCE_ROOM_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1214226026 | 0.2117160300 | Pass | Pass | 0.1659139752 | 0.3638285216 | Pass | Pass |
| 144 | CB_CONFERENCE_ROOM_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1154441902 | 0.1988071562 | Pass | Pass | 0.1647385914 | 0.3669727960 | Pass | Pass |
| 145 | CB_CORRIDOR_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1111895663 | 0.1897134340 | Pass | Pass | 0.1645615068 | 0.3676320153 | Pass | Pass |
| 146 | CB_CORRIDOR_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 3.1610176830E-002 | 5.0808197578E-002 | Pass | Pass | 0.1595348754 | 0.3584974289 | Pass | Pass |
| 147 | CB_CORRIDOR_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 4.4496688635E-002 | 7.3428670350E-002 | Pass | Pass | 0.1608550463 | 0.3605953967 | Pass | Pass |
| 148 | CB_CORRIDOR_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.5737267053E-002 | 2.5031770057E-002 | Pass | Pass | 0.1601846048 | 0.3485836244 | Pass | Pass |
| 149 | CB_CORRIDOR_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 7.3071132161E-002 | 0.1152819783 | Pass | Pass | 0.1639202915 | 0.3661051115 | Pass | Pass |
| 150 | CB_ENTRANCE_LOBBY_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 8.7807240570E-002 | 0.1447965814 | Pass | Pass | 0.1667850386 | 0.3694293556 | Pass | Pass |
| 151 | CB_FACULTY_OFFICE_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1798422721 | 0.3279446947 | Pass | Pass | 0.4209890870 | 1.2110089596 | Pass | Pass |
| 152 | CB_FACULTY_OFFICE_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1902840675 | 0.3448280807 | Pass | Pass | 0.3405286677 | 0.9611523318 | Pass | Pass |
| 153 | CB_FACULTY_OFFICE_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2104412304 | 0.3755099197 | Pass | Pass | 0.2495601908 | 0.6446410347 | Pass | Pass |
| 154 | CB_FACULTY_OFFICE_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1850900139 | 0.3384206241 | Pass | Pass | 0.5486396242 | 1.6134303903 | Pass | Pass |
| 155 | CB_FACULTY_OFFICE_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1951194666 | 0.3568642803 | Pass | Pass | 0.4347363385 | 1.2505438926 | Pass | Pass |
| 156 | CB_FACULTY_OFFICE_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2302861767 | 0.4229670107 | Pass | Pass | 0.3390540202 | 0.9806445479 | Pass | Pass |
| 157 | CB_FACULTY_OFFICE_3_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1854081224 | 0.3391362476 | Pass | Pass | 0.5766444275 | 1.7036401944 | Pass | Pass |
| 158 | CB_FACULTY_OFFICE_3_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1957021544 | 0.3581271695 | Pass | Pass | 0.4466426810 | 1.2870351306 | Pass | Pass |
| 159 | CB_FACULTY_OFFICE_3_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2324173284 | 0.4273646558 | Pass | Pass | 0.3361667322 | 0.9700286887 | Pass | Pass |
| 160 | CB_FACULTY_OFFICE_4_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1853123895 | 0.3389196086 | Pass | Pass | 0.5832098757 | 1.7263947554 | Pass | Pass |
| 161 | CB_FACULTY_OFFICE_4_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1957780309 | 0.3583536286 | Pass | Pass | 0.4474016148 | 1.2887726517 | Pass | Pass |
| 162 | CB_FACULTY_OFFICE_4_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2326762374 | 0.4278833290 | Pass | Pass | 0.3359357928 | 0.9695256036 | Pass | Pass |
| 163 | CB_FACULTY_OFFICE_5_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1852888471 | 0.3388878307 | Pass | Pass | 0.5827291650 | 1.7250592578 | Pass | Pass |
| 164 | CB_FACULTY_OFFICE_5_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1957914643 | 0.3584646303 | Pass | Pass | 0.4472689081 | 1.2883945244 | Pass | Pass |
| 165 | CB_FACULTY_OFFICE_5_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2327029174 | 0.4279319622 | Pass | Pass | 0.3359649870 | 0.9695349041 | Pass | Pass |
| 166 | CB_FACULTY_OFFICE_6_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1856287585 | 0.3394082377 | Pass | Pass | 0.5665722930 | 1.6711876934 | Pass | Pass |
| 167 | CB_FACULTY_OFFICE_6_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1958889692 | 0.3583585910 | Pass | Pass | 0.4470292804 | 1.2882795845 | Pass | Pass |
| 168 | CB_FACULTY_OFFICE_6_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2325104676 | 0.4275429497 | Pass | Pass | 0.3361080519 | 0.9704514661 | Pass | Pass |
| 169 | CB_FACULTY_OFFICE_7_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1855261668 | 0.3393706203 | Pass | Pass | 0.5204780357 | 1.5305925489 | Pass | Pass |
| 170 | CB_FACULTY_OFFICE_7_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1960166753 | 0.3581215863 | Pass | Pass | 0.4373389346 | 1.2644230524 | Pass | Pass |
| 171 | CB_FACULTY_OFFICE_7_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2308887343 | 0.4238708351 | Pass | Pass | 0.3417242549 | 0.9952041702 | Pass | Pass |
| 172 | CB_FACULTY_OFFICE_8_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1807521151 | 0.3347586248 | Pass | Pass | 0.3280104299 | 0.9008602979 | Pass | Pass |
| 173 | CB_FACULTY_OFFICE_8_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1930407473 | 0.3522897436 | Pass | Pass | 0.3253960781 | 0.9167095248 | Pass | Pass |
| 174 | CB_FACULTY_OFFICE_8_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2152715966 | 0.3813343141 | Pass | Pass | 0.2413446396 | 0.6240091301 | Pass | Pass |
| 175 | CB_FACULTY_RESTROOMS_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.5742972943E-003 | 1.9718414068E-003 | Pass | Pass | 0.1594527950 | 0.3638238729 | Pass | Pass |
| 176 | CB_FACULTY_RESTROOMS_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.6351363175E-003 | 2.1557385014E-003 | Pass | Pass | 0.1592837960 | 0.3640227539 | Pass | Pass |
| 177 | CB_FACULTY_RESTROOMS_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.6251347296E-003 | 3.7642312339E-003 | Pass | Pass | 0.1600995313 | 0.3660925274 | Pass | Pass |
| 178 | CB_FACULTY_RESTROOMS_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.5868592646E-003 | 3.2809933354E-003 | Pass | Pass | 0.1594764435 | 0.3637195186 | Pass | Pass |
| 179 | CB_FACULTY_RESTROOMS_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.4153279927E-003 | 3.1005934861E-003 | Pass | Pass | 0.1592786190 | 0.3638976644 | Pass | Pass |
| 180 | CB_FACULTY_RESTROOMS_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.2061813459E-003 | 2.9687495866E-003 | Pass | Pass | 0.1603619256 | 0.3664727844 | Pass | Pass |
| 181 | CB_LAB_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 7.9457594339E-002 | 0.1345587008 | Pass | Pass | 0.1635295014 | 0.3622799471 | Pass | Pass |
| 182 | CB_LAB_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 5.1280101704E-003 | 7.7817991259E-003 | Pass | Pass | 0.1600475027 | 0.3662750193 | Pass | Pass |
| 183 | CB_LAB_3_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 5.2808371982E-003 | 8.2037144512E-003 | Pass | Pass | 0.1600619130 | 0.3663109510 | Pass | Pass |
| 184 | CB_LAB_4_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 7.2501701989E-002 | 0.1224535067 | Pass | Pass | 0.1632417861 | 0.3616265012 | Pass | Pass |
| 185 | CB_LECTURE_ROOM_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.1329742959E-002 | 9.7117327988E-002 | Pass | Pass | 0.1683437221 | 0.3714688863 | Pass | Pass |
| 186 | CB_LECTURE_ROOM_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1180078356 | 0.2124665669 | Pass | Pass | 0.2660886676 | 0.6700884768 | Pass | Pass |
| 187 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 3.4724526989E-002 | 5.7447409316E-002 | Pass | Pass | 0.1744178822 | 0.3778866284 | Pass | Pass |
| 188 | CB_MAIN_STAIRS_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1291335012 | 0.2326479708 | Pass | Pass | 0.1650662559 | 0.3675372309 | Pass | Pass |
| 189 | CB_MAIN_STAIRS_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1367844122 | 0.2498715124 | Pass | Pass | 0.1646799822 | 0.3658011348 | Pass | Pass |
| 190 | CB_MAIN_STAIRS_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1371353744 | 0.2456549907 | Pass | Pass | 0.2625791126 | 0.6910926544 | Pass | Pass |
| 191 | CB_MAIN_STAIRS_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1659615896 | 0.2953185180 | Pass | Pass | 0.4405079196 | 1.4577537334 | Pass | Pass |
| 192 | CB_OFFICES_ENCLOSED_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1569515593 | 0.2944029921 | Pass | Pass | 0.2002748458 | 0.4228382496 | Pass | Pass |
| 193 | CB_OFFICES_ENCLOSED_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1610994726 | 0.3003367324 | Pass | Pass | 0.2280395829 | 0.5157688902 | Pass | Pass |
| 194 | CB_OFFICES_ENCLOSED_3_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1614472378 | 0.3005846504 | Pass | Pass | 0.2311660339 | 0.5269231192 | Pass | Pass |
| 195 | CB_OFFICES_ENCLOSED_4_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1614905669 | 0.3005830444 | Pass | Pass | 0.2314171744 | 0.5277414778 | Pass | Pass |
| 196 | CB_OFFICES_ENCLOSED_5_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1614691644 | 0.3006573473 | Pass | Pass | 0.2313118838 | 0.5274295347 | Pass | Pass |
| 197 | CB_OFFICES_ENCLOSED_6_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1614446944 | 0.3012505661 | Pass | Pass | 0.2314668218 | 0.5280466076 | Pass | Pass |
| 198 | CB_OFFICES_ENCLOSED_7_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1610647236 | 0.3023644680 | Pass | Pass | 0.2167261442 | 0.4758296508 | Pass | Pass |
| 199 | CB_OFFICES_ENCLOSED_8_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1550500676 | 0.2949629121 | Pass | Pass | 0.1694043698 | 0.3691795700 | Pass | Pass |
| 200 | CB_OFFICES_OPEN_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.3245584753E-002 | 0.1028000932 | Pass | Pass | 0.1606394545 | 0.3614113803 | Pass | Pass |
| 201 | CB_OFFICES_OPEN_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.3097960630E-002 | 0.1025114186 | Pass | Pass | 0.1603870482 | 0.3594093399 | Pass | Pass |
| 202 | CB_OFFICES_OPEN_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.1739873296E-002 | 0.1002976624 | Pass | Pass | 0.1600802786 | 0.3596064605 | Pass | Pass |
| 203 | CB_OFFICES_OPEN_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.5732922321E-002 | 0.1083019466 | Pass | Pass | 0.1605944301 | 0.3629327722 | Pass | Pass |
| 204 | CB_PUBLIC_ELEVATORS_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.3978950029E-003 | 3.8616247646E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 205 | CB_PUBLIC_ELEVATORS_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 3.9500834564E-003 | 5.3300304821E-003 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 206 | CB_PUBLIC_ELEVATORS_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.1236290906E-002 | 1.5646943307E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 207 | CB_PUBLIC_ELEVATORS_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.5354238486E-002 | 2.2261053262E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 208 | CB_SECONDARY_STAIRS_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 7.2320955117E-002 | 0.1347270513 | Pass | Pass | 0.1608376814 | 0.3620927089 | Pass | Pass |
| 209 | CB_SECONDARY_STAIRS_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1621019955 | 0.2982890777 | Pass | Pass | 0.5345002767 | 1.6309181474 | Pass | Pass |
| 210 | CB_SECONDARY_STAIRS_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1759791916 | 0.3288427887 | Pass | Pass | 0.4351899828 | 1.3156572188 | Pass | Pass |
| 211 | CB_SECONDARY_STAIRS_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2211263110 | 0.4019298371 | Pass | Pass | 0.3293719550 | 1.1284877057 | Pass | Pass |
| 212 | CB_SECONDARY_STAIRS_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1538390162 | 0.2876447962 | Pass | Pass | 0.4842499284 | 1.4298324038 | Pass | Pass |
| 213 | CB_SECONDARY_STAIRS_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1555608788 | 0.2959756532 | Pass | Pass | 0.3175961989 | 0.8476863339 | Pass | Pass |
| 214 | CB_SECONDARY_STAIRS_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1667892223 | 0.3148452663 | Pass | Pass | 0.3424174619 | 0.9498099410 | Pass | Pass |
| 215 | CB_SECONDARY_STAIRS_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.2171232932 | 0.3980092791 | Pass | Pass | 0.3580851737 | 1.1918064762 | Pass | Pass |
| 216 | CB_STAFF_RESTROOMS_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.5098233051E-003 | 3.0145440459E-003 | Pass | Pass | 0.1597052722 | 0.3653566774 | Pass | Pass |
| 217 | CB_STAFF_RESTROOMS_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 2.3731117618E-003 | 2.9197166219E-003 | Pass | Pass | 0.1596990607 | 0.3653582710 | Pass | Pass |
| 218 | CB_STORAGE_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.0800614160E-002 | 1.5240820471E-002 | Pass | Pass | 0.4198447217 | 2.4882525004 | Pass | Pass |
| 219 | CB_STUDENTS_RESTROOMS_1_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.7745301336E-003 | 2.1210238550E-003 | Pass | Pass | 0.1596844113 | 0.3654494319 | Pass | Pass |
| 220 | CB_STUDENTS_RESTROOMS_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.2685252330E-003 | 1.6509015489E-003 | Pass | Pass | 0.1594520302 | 0.3639176426 | Pass | Pass |
| 221 | CB_STUDENTS_RESTROOMS_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.2859066703E-003 | 1.7345935695E-003 | Pass | Pass | 0.1592924137 | 0.3641016735 | Pass | Pass |
| 222 | CB_STUDENTS_RESTROOMS_1_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.4497309006E-003 | 1.9879711579E-003 | Pass | Pass | 0.1602377947 | 0.3664006684 | Pass | Pass |
| 223 | CB_STUDENTS_RESTROOMS_2_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.3002501333E-003 | 1.6325247788E-003 | Pass | Pass | 0.1596710693 | 0.3655458764 | Pass | Pass |
| 224 | CB_STUDENTS_RESTROOMS_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.1659020752E-003 | 1.7418230739E-003 | Pass | Pass | 0.1594520357 | 0.3640628273 | Pass | Pass |
| 225 | CB_STUDENTS_RESTROOMS_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.0823140959E-003 | 1.5784205481E-003 | Pass | Pass | 0.1593162086 | 0.3642339531 | Pass | Pass |
| 226 | CB_STUDENTS_RESTROOMS_2_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.4888138321E-003 | 2.0784210391E-003 | Pass | Pass | 0.1601818442 | 0.3663430495 | Pass | Pass |
| 227 | CB_STUDIO_1_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 5.1961349932E-002 | 8.1088590314E-002 | Pass | Pass | 0.1704955798 | 0.3740233449 | Pass | Pass |
| 228 | CB_STUDIO_1_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 6.5048830600E-002 | 0.1019135042 | Pass | Pass | 0.1676078283 | 0.3722071136 | Pass | Pass |
| 229 | CB_STUDIO_2_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 7.2715803717E-002 | 0.1130693154 | Pass | Pass | 0.1704206271 | 0.3709710416 | Pass | Pass |
| 230 | CB_STUDIO_2_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 5.7677898698E-002 | 9.0060521956E-002 | Pass | Pass | 0.1686723951 | 0.3734624407 | Pass | Pass |
| 231 | CB_UTILITY_F1 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1408112061 | 0.2815367152 | Pass | Pass | 0.1834968617 | 0.3994472641 | Pass | Pass |
| 232 | CB_UTILITY_F2 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 1.2199754894E-002 | 1.8909818666E-002 | Pass | Pass | 0.5010179441 | 2.7939940200 | Pass | Pass |
| 233 | CB_UTILITY_F3 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 5.5637847595E-002 | 8.9889085274E-002 | Pass | Pass | 0.1652343266 | 0.3671726260 | Pass | Pass |
| 234 | CB_UTILITY_F4 ZN | SizingPeriod: TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 | 0.1005055829 | 0.1694902701 | Pass | Pass | 0.1866256051 | 0.3844118084 | Pass | Pass |
| 235 | CB_CAFE_STUDY_LOUNGE_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.6883282603 | 0.6943168902 | Pass | Pass | 0.5425502346 | 0.5069622881 | Pass | Pass |
| 236 | CB_CLASSROOM_1_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1886225061 | 0.2485723504 | Pass | Pass | 1.5272173095 | 2.6050947347 | Pass | Pass |
| 237 | CB_CLASSROOM_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1833434473 | 0.2482468191 | Pass | Pass | 0.9962347155 | 1.6266756824 | Pass | Pass |
| 238 | CB_CLASSROOM_1_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1860651837 | 0.2908420912 | Pass | Pass | 0.5327101913 | 0.5009869625 | Pass | Pass |
| 239 | CB_CLASSROOM_2_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1999686717 | 0.2010014483 | Pass | Pass | 1.5037735547 | 2.2890503493 | Pass | Pass |
| 240 | CB_CLASSROOM_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1942998960 | 0.2002894909 | Pass | Pass | 1.3207954102 | 1.9155894476 | Pass | Pass |
| 241 | CB_CLASSROOM_2_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1737842799 | 0.2335660662 | Pass | Pass | 0.5850620085 | 0.5408736811 | Pass | Pass |
| 242 | CB_CLASSROOM_3_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1949757878 | 0.1947402646 | Pass | Pass | 1.5011328273 | 2.2837361115 | Pass | Pass |
| 243 | CB_CLASSROOM_3_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1898197302 | 0.1940700536 | Pass | Pass | 1.3195145431 | 1.9190631332 | Pass | Pass |
| 244 | CB_CLASSROOM_3_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1660483211 | 0.2254702430 | Pass | Pass | 0.5791932050 | 0.5309156328 | Pass | Pass |
| 245 | CB_CLASSROOM_4_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1849076069 | 0.1865520197 | Pass | Pass | 1.4522204338 | 2.2237100810 | Pass | Pass |
| 246 | CB_CLASSROOM_4_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1799249441 | 0.1865390891 | Pass | Pass | 1.2479464850 | 1.7932033913 | Pass | Pass |
| 247 | CB_CLASSROOM_4_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1701963883 | 0.2321735133 | Pass | Pass | 0.5796348929 | 0.5302837796 | Pass | Pass |
| 248 | CB_CLASSROOM_5_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1832956319 | 0.1847643445 | Pass | Pass | 1.4315705364 | 2.2049889671 | Pass | Pass |
| 249 | CB_CLASSROOM_5_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1760160275 | 0.1822151617 | Pass | Pass | 1.2497193057 | 1.8051160409 | Pass | Pass |
| 250 | CB_CLASSROOM_5_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1733632775 | 0.2337383967 | Pass | Pass | 0.5825979105 | 0.5379639907 | Pass | Pass |
| 251 | CB_CLASSROOM_6_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.2255668923 | 0.2206120612 | Pass | Pass | 1.5735014772 | 2.5867762426 | Pass | Pass |
| 252 | CB_CLASSROOM_6_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1924564622 | 0.1962593829 | Pass | Pass | 1.3261701681 | 1.9492570277 | Pass | Pass |
| 253 | CB_CLASSROOM_6_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1851469004 | 0.2844278873 | Pass | Pass | 0.5329951165 | 0.5049285836 | Pass | Pass |
| 254 | CB_CLASSROOM_7_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.2463055880 | 0.2398198856 | Pass | Pass | 1.6417713066 | 2.7824787560 | Pass | Pass |
| 255 | CB_CLASSROOM_7_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1991774604 | 0.2040069242 | Pass | Pass | 1.3297754270 | 1.9581146701 | Pass | Pass |
| 256 | CB_CLASSROOM_8_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.2396339720 | 0.2847301831 | Pass | Pass | 1.3628469251 | 2.1089740127 | Pass | Pass |
| 257 | CB_CLASSROOM_8_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1917983243 | 0.2564815446 | Pass | Pass | 0.9943663301 | 1.5878212143 | Pass | Pass |
| 258 | CB_CONFERENCE_ROOM_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.7087248603 | 0.6029217337 | Pass | Pass | 0.5212662405 | 0.6174610882 | Pass | Pass |
| 259 | CB_CONFERENCE_ROOM_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.7819218198 | 0.5700581265 | Pass | Pass | 0.5131023055 | 0.4813649643 | Pass | Pass |
| 260 | CB_CONFERENCE_ROOM_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.8486356124 | 0.6029125715 | Pass | Pass | 0.5091970069 | 0.4785141164 | Pass | Pass |
| 261 | CB_CONFERENCE_ROOM_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.7220184768 | 0.5849317621 | Pass | Pass | 0.5234060168 | 0.5764845098 | Pass | Pass |
| 262 | CB_CORRIDOR_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1101627416 | 0.1107034762 | Pass | Pass | 0.6792834787 | 0.8064743578 | Pass | Pass |
| 263 | CB_CORRIDOR_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 7.5753551566E-002 | 4.8314831413E-002 | Pass | Pass | 0.5939217336 | 0.6949607825 | Pass | Pass |
| 264 | CB_CORRIDOR_F1 ZN | RunPeriod: RUN PERIOD 1 | 5.6032012362E-002 | 4.2309662306E-002 | Pass | Pass | 0.4927056210 | 0.4931584495 | Pass | Pass |
| 265 | CB_CORRIDOR_F2 ZN | RunPeriod: RUN PERIOD 1 | 7.9808918136E-002 | 6.0128926620E-002 | Pass | Pass | 0.5148772271 | 0.4808229632 | Pass | Pass |
| 266 | CB_CORRIDOR_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1073106652 | 0.1154362931 | Pass | Pass | 0.5312100581 | 0.5038323466 | Pass | Pass |
| 267 | CB_ENTRANCE_LOBBY_F1 ZN | RunPeriod: RUN PERIOD 1 | 9.4736237582E-002 | 0.1241345784 | Pass | Pass | 0.6218287217 | 0.6426843185 | Pass | Pass |
| 268 | CB_FACULTY_OFFICE_1_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1510603721 | 0.1432200703 | Pass | Pass | 0.5532137578 | 0.5315520580 | Pass | Pass |
| 269 | CB_FACULTY_OFFICE_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1648161097 | 0.1473870276 | Pass | Pass | 0.5603056195 | 0.5465321033 | Pass | Pass |
| 270 | CB_FACULTY_OFFICE_1_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1707505480 | 0.1997424022 | Pass | Pass | 0.5208406014 | 0.5160419844 | Pass | Pass |
| 271 | CB_FACULTY_OFFICE_2_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1443923054 | 0.1325949211 | Pass | Pass | 0.5428030667 | 0.5165991856 | Pass | Pass |
| 272 | CB_FACULTY_OFFICE_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1572751961 | 0.1341146879 | Pass | Pass | 0.5436540332 | 0.5194906588 | Pass | Pass |
| 273 | CB_FACULTY_OFFICE_2_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1603059360 | 0.1780591908 | Pass | Pass | 0.5324788108 | 0.5359479992 | Pass | Pass |
| 274 | CB_FACULTY_OFFICE_3_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1428361798 | 0.1291269772 | Pass | Pass | 0.5409335715 | 0.5130321142 | Pass | Pass |
| 275 | CB_FACULTY_OFFICE_3_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1550794644 | 0.1298110867 | Pass | Pass | 0.5411088476 | 0.5140697808 | Pass | Pass |
| 276 | CB_FACULTY_OFFICE_3_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1566425974 | 0.1725217156 | Pass | Pass | 0.5260001590 | 0.5242699264 | Pass | Pass |
| 277 | CB_FACULTY_OFFICE_4_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1423967179 | 0.1281548841 | Pass | Pass | 0.5404999733 | 0.5117401526 | Pass | Pass |
| 278 | CB_FACULTY_OFFICE_4_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1545335870 | 0.1286987600 | Pass | Pass | 0.5404853331 | 0.5131343112 | Pass | Pass |
| 279 | CB_FACULTY_OFFICE_4_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1558770956 | 0.1713165161 | Pass | Pass | 0.5254651381 | 0.5223369526 | Pass | Pass |
| 280 | CB_FACULTY_OFFICE_5_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1423559480 | 0.1280779891 | Pass | Pass | 0.5404667469 | 0.5116755450 | Pass | Pass |
| 281 | CB_FACULTY_OFFICE_5_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1545346290 | 0.1286810716 | Pass | Pass | 0.5404651505 | 0.5131049870 | Pass | Pass |
| 282 | CB_FACULTY_OFFICE_5_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1558720827 | 0.1713042870 | Pass | Pass | 0.5254493087 | 0.5223113061 | Pass | Pass |
| 283 | CB_FACULTY_OFFICE_6_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1427221751 | 0.1288517133 | Pass | Pass | 0.5408703626 | 0.5125515846 | Pass | Pass |
| 284 | CB_FACULTY_OFFICE_6_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1550214262 | 0.1296618459 | Pass | Pass | 0.5410165870 | 0.5139172261 | Pass | Pass |
| 285 | CB_FACULTY_OFFICE_6_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1565829101 | 0.1724103126 | Pass | Pass | 0.5259466392 | 0.5240660814 | Pass | Pass |
| 286 | CB_FACULTY_OFFICE_7_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1436998995 | 0.1313418864 | Pass | Pass | 0.5424336714 | 0.5152811431 | Pass | Pass |
| 287 | CB_FACULTY_OFFICE_7_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1569188261 | 0.1334552444 | Pass | Pass | 0.5434292126 | 0.5186232659 | Pass | Pass |
| 288 | CB_FACULTY_OFFICE_7_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1599869465 | 0.1774627568 | Pass | Pass | 0.5315204416 | 0.5339868009 | Pass | Pass |
| 289 | CB_FACULTY_OFFICE_8_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1485995431 | 0.1389957132 | Pass | Pass | 0.5498057297 | 0.5252324612 | Pass | Pass |
| 290 | CB_FACULTY_OFFICE_8_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1632126692 | 0.1449627792 | Pass | Pass | 0.5565336612 | 0.5406889257 | Pass | Pass |
| 291 | CB_FACULTY_OFFICE_8_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1692631717 | 0.1975081262 | Pass | Pass | 0.5231532107 | 0.5135827153 | Pass | Pass |
| 292 | CB_FACULTY_RESTROOMS_1_F2 ZN | RunPeriod: RUN PERIOD 1 | 8.2815967916E-002 | 7.4888971870E-002 | Pass | Pass | 1.4101947539 | 2.4855640432 | Pass | Pass |
| 293 | CB_FACULTY_RESTROOMS_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 8.7383994857E-002 | 7.7600333851E-002 | Pass | Pass | 1.3636391878 | 3.1742926182 | Pass | Pass |
| 294 | CB_FACULTY_RESTROOMS_1_F4 ZN | RunPeriod: RUN PERIOD 1 | 7.7089697504E-002 | 8.6465454947E-002 | Pass | Pass | 0.5947553688 | 0.5033905492 | Pass | Pass |
| 295 | CB_FACULTY_RESTROOMS_2_F2 ZN | RunPeriod: RUN PERIOD 1 | 8.2514351551E-002 | 7.4686308349E-002 | Pass | Pass | 1.3733405828 | 2.3940845747 | Pass | Pass |
| 296 | CB_FACULTY_RESTROOMS_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 9.0477092591E-002 | 8.0384781415E-002 | Pass | Pass | 1.3978034075 | 3.2477297796 | Pass | Pass |
| 297 | CB_FACULTY_RESTROOMS_2_F4 ZN | RunPeriod: RUN PERIOD 1 | 7.7311478284E-002 | 8.8427277936E-002 | Pass | Pass | 0.5922453196 | 0.5003146155 | Pass | Pass |
| 298 | CB_LAB_1_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.4483559616 | 0.4719795958 | Pass | Pass | 0.5677060149 | 0.4998799345 | Pass | Pass |
| 299 | CB_LAB_2_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.4163675337 | 0.4203625153 | Pass | Pass | 0.5826415696 | 0.5192093167 | Pass | Pass |
| 300 | CB_LAB_3_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.4374521676 | 0.4407331099 | Pass | Pass | 0.5747593277 | 0.5137581423 | Pass | Pass |
| 301 | CB_LAB_4_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.4510869170 | 0.4726692846 | Pass | Pass | 0.5634930366 | 0.4990228182 | Pass | Pass |
| 302 | CB_LECTURE_ROOM_1_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1308721366 | 0.1330242573 | Pass | Pass | 0.6301268007 | 0.6969482811 | Pass | Pass |
| 303 | CB_LECTURE_ROOM_2_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1645289503 | 0.1886434954 | Pass | Pass | 0.6064680488 | 0.6629046869 | Pass | Pass |
| 304 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1794336776 | 0.1242971415 | Pass | Pass | 0.4926057146 | 0.4927040789 | Pass | Pass |
| 305 | CB_MAIN_STAIRS_F1 ZN | RunPeriod: RUN PERIOD 1 | 9.1575530863E-002 | 0.1061901897 | Pass | Pass | 0.5246035282 | 0.5112808702 | Pass | Pass |
| 306 | CB_MAIN_STAIRS_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1010945313 | 0.1223132741 | Pass | Pass | 0.6066765215 | 0.6371629110 | Pass | Pass |
| 307 | CB_MAIN_STAIRS_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1111547300 | 0.1304803974 | Pass | Pass | 0.6472360398 | 0.7285500173 | Pass | Pass |
| 308 | CB_MAIN_STAIRS_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1240355792 | 0.1712554619 | Pass | Pass | 0.5226009296 | 0.4974933049 | Pass | Pass |
| 309 | CB_OFFICES_ENCLOSED_1_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1293578273 | 0.1207269223 | Pass | Pass | 0.5040895788 | 0.4926710431 | Pass | Pass |
| 310 | CB_OFFICES_ENCLOSED_2_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1246417946 | 0.1123754845 | Pass | Pass | 0.5036393450 | 0.4935531148 | Pass | Pass |
| 311 | CB_OFFICES_ENCLOSED_3_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1233932604 | 0.1092517009 | Pass | Pass | 0.5029444096 | 0.4923741112 | Pass | Pass |
| 312 | CB_OFFICES_ENCLOSED_4_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1230900093 | 0.1085474473 | Pass | Pass | 0.5027371785 | 0.4924401709 | Pass | Pass |
| 313 | CB_OFFICES_ENCLOSED_5_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1230442850 | 0.1084519520 | Pass | Pass | 0.5027145816 | 0.4924532473 | Pass | Pass |
| 314 | CB_OFFICES_ENCLOSED_6_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1231710870 | 0.1087558874 | Pass | Pass | 0.5027910972 | 0.4923739901 | Pass | Pass |
| 315 | CB_OFFICES_ENCLOSED_7_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1236606123 | 0.1099750735 | Pass | Pass | 0.5031143140 | 0.4922838847 | Pass | Pass |
| 316 | CB_OFFICES_ENCLOSED_8_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1220613517 | 0.1114151355 | Pass | Pass | 0.5012090469 | 0.4921949594 | Pass | Pass |
| 317 | CB_OFFICES_OPEN_F1 ZN | RunPeriod: RUN PERIOD 1 | 9.2962457257E-002 | 6.8632393159E-002 | Pass | Pass | 0.4931259019 | 0.4933986834 | Pass | Pass |
| 318 | CB_OFFICES_OPEN_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1265223355 | 0.1143793765 | Pass | Pass | 1.0652059459 | 1.8994851539 | Pass | Pass |
| 319 | CB_OFFICES_OPEN_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1497047161 | 0.1256969331 | Pass | Pass | 0.7549443399 | 1.4591741381 | Pass | Pass |
| 320 | CB_OFFICES_OPEN_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1299892693 | 0.1241381236 | Pass | Pass | 0.5306386220 | 0.5039176511 | Pass | Pass |
| 321 | CB_PUBLIC_ELEVATORS_F1 ZN | RunPeriod: RUN PERIOD 1 | 2.1031527614E-002 | 1.5992545528E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 322 | CB_PUBLIC_ELEVATORS_F2 ZN | RunPeriod: RUN PERIOD 1 | 2.8521662202E-002 | 2.1796167004E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 323 | CB_PUBLIC_ELEVATORS_F3 ZN | RunPeriod: RUN PERIOD 1 | 3.0642150660E-002 | 2.2683903391E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 324 | CB_PUBLIC_ELEVATORS_F4 ZN | RunPeriod: RUN PERIOD 1 | 4.7802470894E-002 | 3.8679009932E-002 | Pass | Pass | 0.0000000000 | 0.0000000000 | Pass | Pass |
| 325 | CB_SECONDARY_STAIRS_1_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1548810225 | 0.1845125378 | Pass | Pass | 0.5193201081 | 0.4723173478 | Pass | Pass |
| 326 | CB_SECONDARY_STAIRS_1_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1273061440 | 0.1529104067 | Pass | Pass | 0.6210847831 | 0.6742457031 | Pass | Pass |
| 327 | CB_SECONDARY_STAIRS_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1310344820 | 0.1477767853 | Pass | Pass | 0.6664505899 | 0.7623162520 | Pass | Pass |
| 328 | CB_SECONDARY_STAIRS_1_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1508097656 | 0.2120930270 | Pass | Pass | 0.5149655034 | 0.4924092912 | Pass | Pass |
| 329 | CB_SECONDARY_STAIRS_2_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1035521398 | 0.1065832568 | Pass | Pass | 0.5690003316 | 0.5826542223 | Pass | Pass |
| 330 | CB_SECONDARY_STAIRS_2_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1210759990 | 0.1332661459 | Pass | Pass | 0.6525229371 | 0.7387770726 | Pass | Pass |
| 331 | CB_SECONDARY_STAIRS_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1305489394 | 0.1374690030 | Pass | Pass | 0.6500842073 | 0.7187691984 | Pass | Pass |
| 332 | CB_SECONDARY_STAIRS_2_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1530499189 | 0.1995784969 | Pass | Pass | 0.5065623971 | 0.4901864319 | Pass | Pass |
| 333 | CB_STAFF_RESTROOMS_1_F1 ZN | RunPeriod: RUN PERIOD 1 | 6.7935637568E-002 | 6.5849360799E-002 | Pass | Pass | 0.6307397046 | 0.5288002418 | Pass | Pass |
| 334 | CB_STAFF_RESTROOMS_2_F1 ZN | RunPeriod: RUN PERIOD 1 | 6.9723782689E-002 | 6.7556285380E-002 | Pass | Pass | 0.6269316374 | 0.5211231347 | Pass | Pass |
| 335 | CB_STORAGE_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1933218847 | 0.2014241740 | Pass | Pass | 0.6185261248 | 0.5195346555 | Pass | Pass |
| 336 | CB_STUDENTS_RESTROOMS_1_F1 ZN | RunPeriod: RUN PERIOD 1 | 7.3616648497E-002 | 7.0796626308E-002 | Pass | Pass | 0.6106585527 | 0.5045782717 | Pass | Pass |
| 337 | CB_STUDENTS_RESTROOMS_1_F2 ZN | RunPeriod: RUN PERIOD 1 | 8.5192055128E-002 | 7.6924722781E-002 | Pass | Pass | 1.2099587643 | 2.0015977959 | Pass | Pass |
| 338 | CB_STUDENTS_RESTROOMS_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 9.2848275193E-002 | 8.2143790946E-002 | Pass | Pass | 0.8866182046 | 1.7073912973 | Pass | Pass |
| 339 | CB_STUDENTS_RESTROOMS_1_F4 ZN | RunPeriod: RUN PERIOD 1 | 8.1650932987E-002 | 8.8889930571E-002 | Pass | Pass | 0.5840337578 | 0.4982906039 | Pass | Pass |
| 340 | CB_STUDENTS_RESTROOMS_2_F1 ZN | RunPeriod: RUN PERIOD 1 | 8.0804158147E-002 | 7.7556462256E-002 | Pass | Pass | 0.5918949985 | 0.4983756491 | Pass | Pass |
| 341 | CB_STUDENTS_RESTROOMS_2_F2 ZN | RunPeriod: RUN PERIOD 1 | 9.5384065320E-002 | 8.5889836366E-002 | Pass | Pass | 1.4541819572 | 2.5839315864 | Pass | Pass |
| 342 | CB_STUDENTS_RESTROOMS_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1049722767 | 9.2702883360E-002 | Pass | Pass | 1.3705902317 | 3.0587243257 | Pass | Pass |
| 343 | CB_STUDENTS_RESTROOMS_2_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1073433791 | 0.1141835666 | Pass | Pass | 0.5640845531 | 0.4791445796 | Pass | Pass |
| 344 | CB_STUDIO_1_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1508651512 | 0.1417083671 | Pass | Pass | 1.5721457896 | 2.5143472426 | Pass | Pass |
| 345 | CB_STUDIO_1_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1775939440 | 0.1663424518 | Pass | Pass | 1.5206387444 | 2.4158956197 | Pass | Pass |
| 346 | CB_STUDIO_2_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1651178802 | 0.1533434686 | Pass | Pass | 1.5519625150 | 2.3734791342 | Pass | Pass |
| 347 | CB_STUDIO_2_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1656092143 | 0.1567675236 | Pass | Pass | 1.4010371804 | 2.0855905825 | Pass | Pass |
| 348 | CB_UTILITY_F1 ZN | RunPeriod: RUN PERIOD 1 | 0.1146964346 | 0.1018012055 | Pass | Pass | 0.5578665504 | 0.5283017519 | Pass | Pass |
| 349 | CB_UTILITY_F2 ZN | RunPeriod: RUN PERIOD 1 | 0.1108890290 | 9.8458785005E-002 | Pass | Pass | 1.0499772281 | 1.6676551640 | Pass | Pass |
| 350 | CB_UTILITY_F3 ZN | RunPeriod: RUN PERIOD 1 | 0.1126811835 | 9.9996618003E-002 | Pass | Pass | 0.8102952053 | 1.3299363115 | Pass | Pass |
| 351 | CB_UTILITY_F4 ZN | RunPeriod: RUN PERIOD 1 | 0.1159292472 | 0.1312257019 | Pass | Pass | 0.5387432662 | 0.5389296379 | Pass | Pass |
| Plant Loop Name | Sizing Pass {#} | Measured Mass Flow{kg/s} | Measured Demand {W} | Demand Calculated Mass Flow{kg/s} | Sizes Changed {Yes/No} | Previous Volume Flow Rate {m3/s} | New Volume Flow Rate {m3/s} | Demand Check Applied {Yes/No} | Sizing Factor {} | Normalized Change {} | Specific Heat{J/kg-K} | Density {kg/m3} | |
| 1 | CONDENSER WATER LOOP | 1 | 21.5831603 | 433037.08 | 18.5678835 | Yes | 2.158536E-002 | 2.482317E-002 | No | 1.1500 | 0.150000 | 4197.9300 | 999.8980 |
| Component Type | Component Name | IPLV in SI Units {W/W} | IPLV in IP Units {Btu/W-h} | |
| 1 | Chiller:Electric:EIR | 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | 6.51 | 22.34 |
Report: Annual Heat Emissions Report
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Annual Heat Emissions Summary| Envelope Convection | Zone Exfiltration | Zone Exhaust Air | HVAC Relief Air | HVAC Reject Heat | Total | |
| Heat Emissions [GJ] | 3528.07 | -136.8 | 0.00 | -363.1 | 5704.49 | 8732.68 |
Report: Annual Thermal Resilience Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Heat Index Hours| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 3691.00 | 5069.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 5017.50 | 3495.33 | 247.17 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 4946.50 | 3487.67 | 325.83 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 4926.50 | 3799.33 | 34.17 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 5158.67 | 3524.17 | 77.17 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 5114.67 | 3530.67 | 114.67 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 5067.00 | 3686.83 | 6.17 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 5055.00 | 3641.17 | 63.83 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 5154.00 | 3471.83 | 134.17 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 5223.83 | 3523.67 | 12.50 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 4467.67 | 4222.33 | 70.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 5028.00 | 3598.50 | 133.50 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 5035.50 | 3715.50 | 9.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 5413.17 | 3285.83 | 61.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 5431.83 | 3176.50 | 151.67 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 5067.50 | 3686.33 | 6.17 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 4621.50 | 4077.00 | 61.50 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 5146.67 | 3490.67 | 122.67 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 4985.00 | 3731.67 | 43.33 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 4310.83 | 4396.17 | 53.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 4974.83 | 3663.67 | 121.50 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 4267.17 | 4287.00 | 205.83 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 4788.00 | 3692.17 | 279.83 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 8760.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 7496.17 | 1263.83 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 7053.83 | 1706.17 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 7975.17 | 784.83 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 6017.00 | 2743.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 6178.50 | 2581.50 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 7323.50 | 1436.50 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 6015.33 | 2744.67 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 5938.33 | 2821.67 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 6228.00 | 2532.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 5592.67 | 3082.33 | 85.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 5364.50 | 3201.50 | 194.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 4646.33 | 4109.17 | 4.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 5704.50 | 2973.83 | 81.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 5558.17 | 3027.67 | 174.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 5602.00 | 3155.17 | 2.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 5730.83 | 2947.00 | 82.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 5603.50 | 2986.00 | 170.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 5762.83 | 2994.67 | 2.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 5736.17 | 2941.50 | 82.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 5612.00 | 2978.33 | 169.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 5792.67 | 2964.83 | 2.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 5736.67 | 2940.83 | 82.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 5612.17 | 2978.33 | 169.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 5793.33 | 2964.17 | 2.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 5733.33 | 2944.33 | 82.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 5604.67 | 2984.83 | 170.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 5765.00 | 2992.50 | 2.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 5714.00 | 2964.00 | 82.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 5565.17 | 3021.33 | 173.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 5611.33 | 3145.83 | 2.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 5619.00 | 3056.00 | 85.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 5388.50 | 3178.17 | 193.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 4681.83 | 4073.67 | 4.50 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 2010.17 | 6749.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 1824.67 | 6935.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 1744.33 | 7015.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 1961.67 | 6798.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 1691.17 | 7068.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 1934.50 | 6825.50 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 3763.67 | 4975.00 | 21.33 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 3778.00 | 4982.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 3773.17 | 4986.83 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 3764.50 | 4975.67 | 19.83 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 5620.33 | 3139.67 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 5414.83 | 3337.83 | 7.33 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 7271.67 | 1488.33 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 7254.00 | 1506.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 6233.67 | 2526.00 | 0.33 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 6203.83 | 2538.50 | 17.67 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 6335.00 | 2424.50 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 6642.17 | 2117.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 6749.17 | 2010.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 6767.83 | 1992.17 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 6772.83 | 1987.17 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 6773.17 | 1986.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 6771.33 | 1988.67 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 6763.50 | 1996.50 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 6719.50 | 2040.50 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 7818.67 | 941.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 5715.83 | 3044.17 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 5506.50 | 3253.50 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 5049.17 | 3710.83 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 1.50 | 3273.00 | 3257.50 | 2228.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 1593.17 | 7153.67 | 13.17 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 79.33 | 6565.33 | 2115.33 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 819.00 | 5703.50 | 2237.50 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 5559.50 | 3200.50 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 6077.50 | 2642.00 | 40.50 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 6072.67 | 2569.83 | 117.50 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 5198.67 | 3559.00 | 2.33 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 6796.50 | 1963.50 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 6176.50 | 2555.33 | 28.17 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 6047.67 | 2591.50 | 120.83 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 5294.17 | 3461.33 | 4.50 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 2725.83 | 6034.17 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 2406.83 | 6353.17 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 3824.83 | 4935.17 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 1039.83 | 7720.17 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 985.50 | 7774.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 905.50 | 7854.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 891.00 | 7869.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 1803.50 | 6956.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 1578.83 | 7181.17 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 1138.67 | 7621.33 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 671.50 | 8088.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 4992.83 | 3716.83 | 50.33 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 4446.83 | 4222.50 | 90.67 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 5010.67 | 3686.33 | 63.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 4501.33 | 4179.50 | 79.17 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 4.17 | 8755.83 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 1677.00 | 7083.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 4749.83 | 4010.17 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 5367.33 | 3392.67 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | 8755.83 | 7153.67 | 3257.50 | 2228.00 |
| Average | 4793.86 | 3749.22 | 169.92 | 27.95 | 19.04 |
| Sum | 560881.50 | 438658.83 | 19881.00 | 3270.67 | 2228.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 78377.18 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 37407.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 37407.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 49876.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 37399.01 | 8.29 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 37385.19 | 22.11 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 49876.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 37396.24 | 11.06 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 37382.42 | 24.88 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 49876.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 37407.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 37385.19 | 22.11 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 49876.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 37379.66 | 27.64 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 37374.13 | 33.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 49876.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 37390.71 | 16.58 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 37376.89 | 30.41 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 49876.40 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 37393.48 | 13.82 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 37382.42 | 24.88 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 37407.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 37407.30 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 43277.85 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 28851.90 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 28851.90 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 28851.90 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 14107.03 | 56.63 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 24353.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 24353.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 24353.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 24353.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 115956.52 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 99752.80 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 17839.46 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 1485.66 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 23437.61 | 85.34 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 25364.99 | 15.03 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 25361.23 | 18.79 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 25380.02 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 51468.10 | 11.93 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 51336.84 | 143.19 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 51392.53 | 87.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 51464.12 | 15.91 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 115956.52 | 143.19 | 0.00 | 0.00 | 0.00 |
| Average | 15415.12 | 5.72 | 0.00 | 0.00 | 0.00 |
| Sum | 1803568.46 | 669.29 | 0.00 | 0.00 | 0.00 |
| Safe (≤ 26.7°C) [hr] | Caution (> 26.7°C, ≤ 32.2°C) [hr] | Extreme Caution (> 32.2°C, ≤ 39.4°C) [hr] | Danger (> 39.4°C, ≤ 51.7°C) [hr] | Extreme Danger (> 51.7°C) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 2860.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 3379.50 | 0.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 3378.67 | 1.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 3379.33 | 0.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 3378.50 | 1.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 3378.67 | 1.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 3378.33 | 1.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 3378.00 | 2.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 3379.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 3378.17 | 1.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 3378.50 | 1.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 3372.50 | 7.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 3574.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 3574.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 3574.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 3574.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 1940.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 1940.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 3371.83 | 8.17 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 3378.67 | 1.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 3378.33 | 1.67 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 3181.50 | 0.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 3176.00 | 6.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 3178.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 3181.33 | 0.67 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 3574.00 | 8.17 | 0.00 | 0.00 | 0.00 |
| Average | 2137.10 | 0.37 | 0.00 | 0.00 | 0.00 |
| Sum | 250040.33 | 43.67 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 3692.67 | 5067.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 4040.33 | 4657.33 | 62.33 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 4003.33 | 4661.50 | 95.17 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 3976.83 | 4782.33 | 0.83 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 4230.00 | 4530.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 4169.50 | 4588.00 | 2.50 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 4110.83 | 4649.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 4180.83 | 4579.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 4159.33 | 4595.50 | 5.17 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 4143.67 | 4616.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 3961.67 | 4798.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 4122.33 | 4637.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 4092.83 | 4667.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 4283.67 | 4476.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 4245.50 | 4514.33 | 0.17 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 4106.83 | 4653.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 4012.83 | 4747.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 4159.17 | 4595.67 | 5.17 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 3987.17 | 4770.00 | 2.83 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 3909.17 | 4850.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 4132.67 | 4623.50 | 3.83 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 3812.17 | 4912.00 | 35.83 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 3968.50 | 4708.33 | 83.17 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 8757.83 | 2.17 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 7652.33 | 1107.67 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 7014.83 | 1745.17 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 7791.00 | 969.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 5145.50 | 3614.50 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 6451.33 | 2308.67 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 7313.00 | 1447.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 5801.83 | 2958.17 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 5829.67 | 2930.33 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 5117.17 | 3642.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 4362.00 | 4382.17 | 15.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 4247.00 | 4468.33 | 44.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 4014.33 | 4745.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 4396.00 | 4347.67 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 4317.00 | 4405.83 | 37.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 4291.33 | 4468.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 4402.50 | 4341.17 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 4326.17 | 4397.00 | 36.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 4333.50 | 4426.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 4404.17 | 4339.50 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 4327.17 | 4396.50 | 36.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 4341.83 | 4418.17 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 4404.00 | 4339.67 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 4327.17 | 4396.50 | 36.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 4341.83 | 4418.17 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 4403.00 | 4340.67 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 4326.33 | 4396.83 | 36.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 4333.83 | 4426.17 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 4398.00 | 4345.67 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 4318.33 | 4403.83 | 37.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 4294.33 | 4465.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 4370.17 | 4373.83 | 16.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 4261.17 | 4452.50 | 46.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 4028.33 | 4731.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 3321.50 | 5438.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 2911.33 | 5848.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 2923.50 | 5836.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 3322.50 | 5437.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 2839.67 | 5920.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 3026.33 | 5733.67 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 3716.33 | 5043.33 | 0.33 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 3768.00 | 4992.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 3763.33 | 4996.67 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 3716.50 | 5043.00 | 0.50 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 4832.83 | 3927.17 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 4333.50 | 4426.50 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 6709.67 | 2050.33 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 5852.17 | 2907.83 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 5062.50 | 3697.50 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 4953.00 | 3807.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 4913.17 | 3846.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 5301.67 | 3458.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 5408.50 | 3351.50 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 5424.67 | 3335.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 5428.50 | 3331.50 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 5428.67 | 3331.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 5426.00 | 3334.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 5416.67 | 3343.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 5345.00 | 3415.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 8260.17 | 499.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 5951.17 | 2808.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 5723.33 | 3036.67 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 5323.67 | 3436.33 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 97.67 | 3628.00 | 2367.67 | 2666.67 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 2886.33 | 5870.50 | 3.17 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 7169.00 | 1591.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 7034.17 | 1725.83 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 4810.33 | 3949.67 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 4863.67 | 3896.33 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 4775.83 | 3979.17 | 5.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 4400.83 | 4359.17 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 5782.83 | 2977.17 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 4976.83 | 3783.17 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 4795.50 | 3956.67 | 7.83 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 4427.50 | 4332.50 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 4180.17 | 4579.83 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 3999.00 | 4761.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 3808.17 | 4951.83 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 2819.33 | 5940.67 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 2343.17 | 6416.83 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 1989.50 | 6770.50 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 2006.17 | 6753.83 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 3237.00 | 5523.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 2747.00 | 6013.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 2198.17 | 6561.83 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 1321.67 | 7438.33 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 4373.33 | 4386.67 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 4097.83 | 4661.50 | 0.67 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 4357.00 | 4403.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 4142.17 | 4617.83 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 52.67 | 8707.33 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 3801.33 | 4958.67 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 5473.50 | 3286.50 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 6028.17 | 2731.83 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 2.17 | 0.00 | 0.00 | 0.00 |
| Max | 8757.83 | 8707.33 | 5870.50 | 2367.67 | 2666.67 |
| Average | 4309.05 | 4291.93 | 115.97 | 20.26 | 22.79 |
| Sum | 504158.33 | 502155.33 | 13568.83 | 2370.83 | 2666.67 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 78377.18 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 34241.32 | 3165.98 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 34264.49 | 3142.81 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 45620.17 | 4256.23 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 34291.21 | 3116.09 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 34181.30 | 3226.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 45926.77 | 3949.63 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 34256.39 | 3150.91 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 33894.16 | 3513.14 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 45720.03 | 4156.37 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 34646.99 | 2760.31 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 33930.36 | 3476.94 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 45816.91 | 4059.49 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 33686.19 | 3721.10 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 33485.93 | 3921.37 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 45894.48 | 3981.92 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 34342.28 | 3065.02 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 33859.48 | 3547.82 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 45488.72 | 4387.68 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 34749.59 | 2657.71 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 34289.63 | 3117.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 34696.09 | 2711.21 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 34422.31 | 2984.99 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 43226.91 | 50.94 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 28820.55 | 31.35 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 28742.17 | 109.72 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 28851.90 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 13706.35 | 457.31 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 1484.83 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 1484.61 | 1.04 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 1484.94 | 0.72 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 1484.78 | 0.88 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 1484.28 | 1.37 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 1484.45 | 1.21 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 1484.78 | 0.88 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 1484.28 | 1.38 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 1484.39 | 1.27 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 1484.78 | 0.88 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 1484.23 | 1.43 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 1484.34 | 1.32 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 1484.78 | 0.88 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 1484.23 | 1.43 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 1484.34 | 1.32 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 1484.78 | 0.88 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 1484.28 | 1.37 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 1484.39 | 1.26 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 1484.78 | 0.88 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 1484.28 | 1.37 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 1484.45 | 1.21 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 1484.83 | 0.82 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 1484.61 | 1.04 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 1484.89 | 0.77 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 24195.86 | 157.93 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 24336.82 | 16.97 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 24339.85 | 13.94 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 24194.65 | 159.14 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 110046.21 | 5910.31 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 91554.14 | 8198.66 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 17836.75 | 2.72 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 1485.33 | 0.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 1485.38 | 0.28 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 1485.38 | 0.28 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 1485.38 | 0.27 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 1485.38 | 0.27 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 1485.38 | 0.27 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 1485.38 | 0.27 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 1485.33 | 0.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 23435.87 | 87.08 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 25327.41 | 52.62 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 25321.77 | 58.25 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 25380.02 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 49873.12 | 1606.91 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 49885.05 | 1594.98 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 49881.08 | 1598.95 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 49956.65 | 1523.38 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 110046.21 | 8198.66 | 0.00 | 0.00 | 0.00 |
| Average | 14585.53 | 835.30 | 0.00 | 0.00 | 0.00 |
| Sum | 1706507.44 | 97730.31 | 0.00 | 0.00 | 0.00 |
| Little to no Discomfort (≤ 29) [hr] | Some Discomfort (> 29, ≤ 40) [hr] | Great Discomfort; Avoid Exertion (> 40, ≤ 45) [hr] | Dangerous (> 45, ≤ 50) [hr] | Heat Stroke Quite Possible (> 50) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 2860.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 3152.17 | 227.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 3153.67 | 226.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 3151.00 | 229.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 3163.17 | 216.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 3156.33 | 223.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 3170.33 | 209.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 3160.50 | 219.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 3137.83 | 242.17 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 3159.33 | 220.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 3185.50 | 194.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 3139.50 | 240.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 3164.33 | 215.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 3124.00 | 256.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 3110.17 | 269.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 3168.67 | 211.33 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 3168.00 | 212.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 3136.00 | 244.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 3144.33 | 235.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 3195.50 | 184.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 3164.00 | 216.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 3184.33 | 195.67 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 3164.83 | 215.17 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 3377.83 | 2.17 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 3378.00 | 2.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 3373.00 | 7.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 3316.50 | 63.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 3377.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 3377.00 | 3.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 3377.83 | 2.17 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 3377.50 | 2.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 3376.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 3376.50 | 3.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 3377.50 | 2.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 3376.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 3376.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 3377.50 | 2.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 3376.17 | 3.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 3376.17 | 3.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 3377.50 | 2.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 3376.17 | 3.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 3376.17 | 3.83 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 3377.50 | 2.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 3376.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 3376.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 3377.50 | 2.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 3376.33 | 3.67 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 3376.50 | 3.50 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 3377.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 3377.00 | 3.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 3377.67 | 2.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 3541.83 | 32.17 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 3568.67 | 5.33 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 3569.00 | 5.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 3541.83 | 32.17 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 1828.83 | 111.17 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 3163.67 | 216.33 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 1939.67 | 0.33 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 3379.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 3379.17 | 0.83 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 3379.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 3371.67 | 8.33 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 3375.33 | 4.67 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 3374.83 | 5.17 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 3380.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 3114.67 | 67.33 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 3115.17 | 66.83 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 3115.00 | 67.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 3118.17 | 63.83 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 3569.00 | 269.83 | 0.00 | 0.00 | 0.00 |
| Average | 2088.34 | 49.13 | 0.00 | 0.00 | 0.00 |
| Sum | 244335.67 | 5748.33 | 0.00 | 0.00 | 0.00 |
| Hours of Safety [hr] | End Time of the Safety Duration | Safe Temperature Exceedance Hours [hr] | Safe Temperature Exceedance OccupantHours [hr] | Safe Temperature Exceedance OccupiedHours [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| Average | 5615.38 | - | 0.00 | 0.00 | 0.00 |
| Sum | 657000.00 | - | 0.00 | 0.00 | 0.00 |
| Hours of Safety [hr] | End Time of the Safety Duration | Safe Temperature Exceedance Hours [hr] | Safe Temperature Exceedance OccupantHours [hr] | Safe Temperature Exceedance OccupiedHours [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.50 | 01-JAN-00:30 | 638.67 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 10.17 | 01-JAN-10:10 | 26.50 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 10.83 | 01-JAN-10:49 | 42.50 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 11.17 | 01-JAN-11:10 | 88.50 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 13.50 | 01-JAN-13:30 | 1.83 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 13.50 | 01-JAN-13:30 | 3.67 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 11.83 | 01-JAN-11:49 | 23.83 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 13.50 | 01-JAN-13:30 | 1.67 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 13.50 | 01-JAN-13:30 | 2.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 11.83 | 01-JAN-11:49 | 16.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 182.33 | 08-JAN-14:20 | 0.83 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 14.17 | 01-JAN-14:10 | 1.50 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 11.83 | 01-JAN-11:49 | 18.67 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 181.67 | 08-JAN-13:40 | 1.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 11.83 | 01-JAN-11:49 | 22.83 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 12.17 | 01-JAN-12:10 | 3.33 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 13.50 | 01-JAN-13:30 | 2.50 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 10.50 | 01-JAN-10:30 | 89.17 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 11.50 | 01-JAN-11:30 | 9.67 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 13.50 | 01-JAN-13:30 | 5.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 10.83 | 01-JAN-10:49 | 67.67 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 11.50 | 01-JAN-11:30 | 55.67 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 2700.83 | 23-APR-12:49 | 15.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 2534.00 | 16-APR-14:00 | 23.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 12.50 | 01-JAN-12:30 | 80.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 2700.83 | 23-APR-12:49 | 16.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 2534.67 | 16-APR-14:40 | 23.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 12.50 | 01-JAN-12:30 | 68.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 2700.83 | 23-APR-12:49 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 2534.67 | 16-APR-14:40 | 23.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 12.50 | 01-JAN-12:30 | 65.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 2700.83 | 23-APR-12:49 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 2534.67 | 16-APR-14:40 | 22.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 12.50 | 01-JAN-12:30 | 65.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 2700.83 | 23-APR-12:49 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 2534.67 | 16-APR-14:40 | 22.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 12.50 | 01-JAN-12:30 | 65.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 2700.83 | 23-APR-12:49 | 16.33 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 2534.67 | 16-APR-14:40 | 23.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 12.50 | 01-JAN-12:30 | 65.50 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 2700.83 | 23-APR-12:49 | 16.17 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 2534.67 | 16-APR-14:40 | 23.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 12.50 | 01-JAN-12:30 | 68.67 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 2700.83 | 23-APR-12:49 | 14.83 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 2534.00 | 16-APR-14:00 | 24.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 12.50 | 01-JAN-12:30 | 79.67 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 0.50 | 01-JAN-00:30 | 504.17 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 0.50 | 01-JAN-00:30 | 484.67 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 0.50 | 01-JAN-00:30 | 516.33 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 0.50 | 01-JAN-00:30 | 513.83 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 3373.67 | 21-MAY-13:40 | 0.50 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 3374.33 | 21-MAY-14:20 | 0.17 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 3370.50 | 21-MAY-10:30 | 1.50 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 8760.00 | - | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 2703.83 | 23-APR-15:49 | 1.33 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | - | 0.00 | 0.00 | 0.00 |
| Max | 8760.00 | - | 638.67 | 0.00 | 0.00 |
| Average | 1769.61 | - | 34.38 | 0.00 | 0.00 |
| Sum | 207044.67 | - | 4022.17 | 0.00 | 0.00 |
| Cooling Setpoint Unmet Degree-Hours [°C·hr] | Cooling Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] | Cooling Setpoint Unmet Occupied Degree-Hours [°C·hr] | Heating Setpoint Unmet Degree-Hours [°C·hr] | Heating Setpoint Unmet Occupant-Weighted Degree-Hours [°C·hr] | Heating Setpoint Unmet Occupied Degree-Hours [°C·hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 1279.89 | 16048.23 | 379.68 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 313.07 | 3610.07 | 236.84 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 403.63 | 4035.50 | 265.45 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 162.17 | 668.11 | 33.09 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 665.09 | 9462.82 | 623.57 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 770.52 | 10184.58 | 675.23 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 293.80 | 4452.56 | 213.70 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 656.26 | 9489.12 | 623.99 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 821.74 | 11290.61 | 749.16 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 306.50 | 5009.61 | 240.73 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 449.14 | 6564.56 | 427.50 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 825.35 | 11753.65 | 779.78 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 321.54 | 5221.22 | 250.83 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 790.99 | 11758.18 | 776.98 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 862.37 | 12414.66 | 826.12 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 300.00 | 4596.83 | 220.75 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 829.16 | 11524.22 | 761.19 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 846.83 | 11505.82 | 763.99 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 238.55 | 2311.73 | 112.07 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 858.50 | 10445.40 | 689.19 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 795.90 | 10020.44 | 664.28 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 353.77 | 1662.70 | 107.15 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 287.53 | 1575.68 | 101.47 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 69.53 | 1631.88 | 69.53 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 267.91 | 4189.00 | 267.91 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 399.76 | 6247.77 | 399.76 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 63.74 | 997.18 | 63.74 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 2412.89 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 3626.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 485.32 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 2206.28 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 850.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 1427.52 | 9232.02 | 1410.61 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 280.38 | 150.36 | 248.15 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 378.14 | 189.78 | 313.68 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 153.70 | 29.44 | 49.16 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 234.38 | 120.25 | 201.07 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 316.59 | 154.49 | 257.58 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 130.45 | 24.88 | 42.43 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 226.26 | 115.26 | 193.29 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 303.80 | 147.79 | 246.92 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 125.63 | 24.01 | 41.07 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 224.75 | 114.43 | 192.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 300.78 | 146.28 | 244.52 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 124.48 | 23.82 | 40.75 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 224.66 | 114.39 | 191.93 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 300.59 | 146.16 | 244.33 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 124.47 | 23.81 | 40.74 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 225.35 | 114.74 | 192.43 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 303.03 | 147.35 | 246.21 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 125.52 | 23.97 | 41.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 230.47 | 118.16 | 197.63 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 312.74 | 152.44 | 254.16 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 129.86 | 24.68 | 42.10 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 253.08 | 134.44 | 222.11 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 349.90 | 173.89 | 287.26 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 149.71 | 28.06 | 46.97 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 1.35 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 1.85 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 5.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 1.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 1.91 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 6.70 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 706.35 | 184.99 | 24.23 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 711.71 | 1046.57 | 124.33 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 813.80 | 1278.13 | 151.17 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 722.73 | 356.48 | 43.85 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 317.21 | 19539.10 | 309.06 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 508.20 | 20246.94 | 499.78 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 237.67 | 2062.17 | 222.66 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 1414.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 1883.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 2016.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 682.05 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 202.48 | 121.21 | 196.70 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 171.69 | 100.90 | 166.16 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 165.85 | 97.10 | 160.42 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 164.57 | 96.27 | 159.16 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 164.40 | 96.17 | 159.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 164.73 | 96.42 | 159.34 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 166.44 | 97.74 | 161.17 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 178.05 | 106.17 | 173.46 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 1657.33 | 15445.20 | 1644.11 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 1836.57 | 18291.73 | 1801.30 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 2054.63 | 20161.64 | 2004.73 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 611.25 | 6273.73 | 581.26 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 210.15 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 104.90 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 130.23 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 110.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 262.52 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 260.86 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 335.01 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 128.51 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 1.02 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 1.04 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 130.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.44 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 2.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 8.75 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.18 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.55 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 3.11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 23.12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 341.71 | 6306.46 | 294.72 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 984.33 | 16150.97 | 792.56 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 733.17 | 13907.02 | 676.49 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 542.91 | 7816.08 | 371.09 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 6.97 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 1.21 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 1.57 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 13.47 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 3626.05 | 20246.94 | 2004.73 | 0.00 | 0.00 | 0.00 |
| Average | 450.29 | 2993.39 | 236.65 | 0.00 | 0.00 | 0.00 |
| Sum | 52684.14 | 350226.24 | 27688.55 | 0.00 | 0.00 | 0.00 |
| Very-cold Exceedance OccupantHours [hr] | Cool Exceedance OccupantHours [hr] | Warm Exceedance OccupantHours [hr] | Very-hot Exceedance OccupantHours [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 |
| Very-cold Exceedance OccupantHours [hr] | Cool Exceedance OccupantHours [hr] | Warm Exceedance OccupantHours [hr] | Very-hot Exceedance OccupantHours [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 0.00 | 0.00 |
| Average | 0.00 | 0.00 | 0.00 | 0.00 |
| Sum | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Climatic Data Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
SizingPeriod:DesignDay| Maximum Dry Bulb [C] | Daily Temperature Range [deltaC] | Humidity Value | Humidity Type | Wind Speed [m/s] | Wind Direction | |
| TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 33.90 | 7.90 | 25.10 | Wetbulb [C] | 3.10 | 270.00 |
| TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 4.60 | 0.00 | 4.60 | Wetbulb [C] | 2.50 | 10.00 |
| Monthly Total Precipitation from .epw [mm] | Monthly Total Hours of Rain from .epw | Monthly Total Precipitation in Site:Precipitation [mm] | Monthly Total Roof Irrigation Depth [mm] | Monthly Total Rain Collection Volume [m3] | |
| Jan | 20.00 | 20 | |||
| Feb | 39.17 | 30 | |||
| Mar | 88.83 | 61 | |||
| Apr | 164.00 | 120 | |||
| May | 54.00 | 54 | |||
| Jun | 112.00 | 89 | |||
| Jul | 98.00 | 72 | |||
| Aug | 94.00 | 67 | |||
| Sep | 136.00 | 98 | |||
| Oct | 104.00 | 93 | |||
| Nov | 132.00 | 114 | |||
| Dec | 200.00 | 137 |
| Value | |
| None |
Report: Envelope Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Opaque Exterior| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| SURFACE 6 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.17 | 180.00 | 90.00 | S |
| SURFACE 7 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.61 | 270.00 | 90.00 | W |
| SURFACE 221 | FOUNDATION F 126 PERIM 2652 AREA 17977 | 1.00 | 0.186 | 0.192 | 179.77 | 179.77 | 0.00 | 180.00 | |
| SURFACE 777 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.88 | 180.00 | 90.00 | S |
| SURFACE 781 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.62 | 90.00 | 90.00 | E |
| SURFACE 960 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.58 | 90.00 | 90.00 | E |
| SURFACE 961 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 451 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.11 | 180.00 | 90.00 | S |
| SURFACE 453 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.59 | 270.00 | 90.00 | W |
| SURFACE 455 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 75.25 | 75.25 | 0.00 | 0.00 | |
| SURFACE 773 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.86 | 180.00 | 90.00 | S |
| SURFACE 785 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 485 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.11 | 180.00 | 90.00 | S |
| SURFACE 44 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 75.25 | 75.25 | 0.00 | 0.00 | |
| SURFACE 764 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.85 | 180.00 | 90.00 | S |
| SURFACE 751 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.81 | 180.00 | 90.00 | S |
| SURFACE 489 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.12 | 180.00 | 90.00 | S |
| SURFACE 494 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 75.25 | 75.25 | 0.00 | 0.00 | |
| SURFACE 759 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.87 | 180.00 | 90.00 | S |
| SURFACE 744 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 519 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.12 | 180.00 | 90.00 | S |
| SURFACE 952 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 75.25 | 75.25 | 0.00 | 0.00 | |
| SURFACE 729 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.87 | 180.00 | 90.00 | S |
| SURFACE 503 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 524 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.11 | 180.00 | 90.00 | S |
| SURFACE 528 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 75.25 | 75.25 | 0.00 | 0.00 | |
| SURFACE 704 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.90 | 180.00 | 90.00 | S |
| SURFACE 297 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 530 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.10 | 180.00 | 90.00 | S |
| SURFACE 534 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.58 | 90.00 | 90.00 | E |
| SURFACE 535 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 75.25 | 75.25 | 0.00 | 0.00 | |
| SURFACE 696 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.92 | 180.00 | 90.00 | S |
| SURFACE 271 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 691 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.88 | 180.00 | 90.00 | S |
| SURFACE 692 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.60 | 270.00 | 90.00 | W |
| SURFACE 264 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 27.17 | 18.82 | 180.00 | 90.00 | S |
| SURFACE 265 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.58 | 270.00 | 90.00 | W |
| SURFACE 96 | FOUNDATION F 126 PERIM 0 AREA 4599 | 1.00 | 0.006 | 0.006 | 45.99 | 45.99 | 0.00 | 180.00 | |
| SURFACE 579 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 30.66 | 30.66 | 0.00 | 0.00 | |
| SURFACE 536 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.36 | 180.00 | 90.00 | S |
| SURFACE 23 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.39 | 180.00 | 90.00 | S |
| SURFACE 26 | FOUNDATION F 126 PERIM 305 AREA 12217 | 1.00 | 0.032 | 0.032 | 122.17 | 122.17 | 0.00 | 180.00 | |
| SURFACE 716 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.39 | 180.00 | 90.00 | S |
| SURFACE 460 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.39 | 180.00 | 90.00 | S |
| SURFACE 481 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 92.90 | 92.90 | 180.00 | 0.00 | |
| SURFACE 949 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 29.26 | 29.26 | 0.00 | 0.00 | |
| SURFACE 950 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 29.26 | 29.26 | 0.00 | 0.00 | |
| SURFACE 227 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.09 | 180.00 | 90.00 | S |
| SURFACE 27 | FOUNDATION F 126 PERIM 914 AREA 7525 | 1.00 | 0.153 | 0.157 | 75.25 | 75.25 | 0.00 | 180.00 | |
| SURFACE 930 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 1110 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 685 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.22 | 0.00 | 90.00 | N |
| SURFACE 687 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 922 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.21 | 0.00 | 90.00 | N |
| SURFACE 1104 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 677 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 681 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 918 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.23 | 0.00 | 90.00 | N |
| SURFACE 1098 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 673 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 675 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 910 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.23 | 0.00 | 90.00 | N |
| SURFACE 1092 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 665 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 669 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 906 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.24 | 0.00 | 90.00 | N |
| SURFACE 1086 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 661 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 663 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 898 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.22 | 0.00 | 90.00 | N |
| SURFACE 1080 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 653 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 657 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 894 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.23 | 0.00 | 90.00 | N |
| SURFACE 1074 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 649 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 651 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 885 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.22 | 0.00 | 90.00 | N |
| SURFACE 1070 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 641 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 645 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 639 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 605 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 560 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.11 | 0.00 | 90.00 | N |
| SURFACE 564 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.62 | 270.00 | 90.00 | W |
| SURFACE 565 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 567 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.11 | 0.00 | 90.00 | N |
| SURFACE 573 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 625 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.11 | 0.00 | 90.00 | N |
| SURFACE 626 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 631 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.15 | 0.00 | 90.00 | N |
| SURFACE 632 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.56 | 90.00 | 90.00 | E |
| SURFACE 633 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 145 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.56 | 90.00 | 90.00 | E |
| SURFACE 151 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.18 | 0.00 | 90.00 | N |
| SURFACE 144 | FOUNDATION F 126 PERIM 3307 AREA 27035 | 1.00 | 0.154 | 0.158 | 270.35 | 270.35 | 0.00 | 180.00 | |
| SURFACE 61 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 32.61 | 22.58 | 90.00 | 90.00 | E |
| SURFACE 62 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.17 | 180.00 | 90.00 | S |
| SURFACE 57 | FOUNDATION F 126 PERIM 2652 AREA 1505 | 1.00 | 0.222 | 0.231 | 150.50 | 150.50 | 0.00 | 180.00 | |
| SURFACE 91 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.62 | 270.00 | 90.00 | W |
| SURFACE 92 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.18 | 0.00 | 90.00 | N |
| SURFACE 87 | FOUNDATION F 126 PERIM 3307 AREA 27035 | 1.00 | 0.154 | 0.158 | 270.35 | 270.35 | 0.00 | 180.00 | |
| SURFACE 33 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.39 | 180.00 | 90.00 | S |
| SURFACE 29 | FOUNDATION F 126 PERIM 305 AREA 1858 | 1.00 | 0.207 | 0.214 | 18.58 | 18.58 | 0.00 | 180.00 | |
| SURFACE 739 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.42 | 180.00 | 90.00 | S |
| SURFACE 510 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.37 | 180.00 | 90.00 | S |
| SURFACE 499 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 12.08 | 8.42 | 180.00 | 90.00 | S |
| SURFACE 500 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 18.58 | 18.58 | 0.00 | 0.00 | |
| SURFACE 205 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 202 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 197 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 196 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 193 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 190 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 185 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 184 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 181 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 178 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 173 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 172 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 169 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.20 | 0.00 | 90.00 | N |
| SURFACE 166 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 161 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 13.29 | 9.21 | 0.00 | 90.00 | N |
| SURFACE 160 | FOUNDATION F 126 PERIM 335 AREA 1226 | 1.00 | 0.345 | 0.365 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 103 | FOUNDATION F 126 PERIM 0 AREA 19417 | 1.00 | 0.006 | 0.006 | 194.17 | 194.17 | 0.00 | 180.00 | |
| SURFACE 599 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 209.50 | 209.50 | 180.00 | 0.00 | |
| SURFACE 37 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.66 | 6.72 | 180.00 | 90.00 | S |
| SURFACE 35 | FOUNDATION F 126 PERIM 244 AREA 1189 | 1.00 | 0.259 | 0.270 | 11.89 | 11.89 | 0.00 | 180.00 | |
| SURFACE 942 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.66 | 6.72 | 180.00 | 90.00 | S |
| SURFACE 211 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.66 | 6.70 | 180.00 | 90.00 | S |
| SURFACE 938 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.66 | 6.72 | 180.00 | 90.00 | S |
| SURFACE 210 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 11.89 | 11.89 | 0.00 | 0.00 | |
| SURFACE 79 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.33 | 270.00 | 90.00 | W |
| SURFACE 75 | FOUNDATION F 126 PERIM 229 AREA 1254 | 1.00 | 0.230 | 0.239 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 812 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.33 | 270.00 | 90.00 | W |
| SURFACE 966 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.27 | 270.00 | 90.00 | W |
| SURFACE 551 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.33 | 270.00 | 90.00 | W |
| SURFACE 552 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 85 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.27 | 90.00 | 90.00 | E |
| SURFACE 81 | FOUNDATION F 126 PERIM 229 AREA 1254 | 1.00 | 0.230 | 0.239 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 831 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.30 | 90.00 | 90.00 | E |
| SURFACE 1011 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.27 | 90.00 | 90.00 | E |
| SURFACE 557 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 9.06 | 6.28 | 90.00 | 90.00 | E |
| SURFACE 558 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 153 | FOUNDATION F 126 PERIM 0 AREA 996 | 1.00 | 0.006 | 0.006 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 125 | FOUNDATION F 126 PERIM 0 AREA 996 | 1.00 | 0.006 | 0.006 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 51 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 36.23 | 25.10 | 180.00 | 90.00 | S |
| SURFACE 50 | FOUNDATION F 126 PERIM 914 AREA 7525 | 1.00 | 0.153 | 0.157 | 75.25 | 75.25 | 0.00 | 180.00 | |
| SURFACE 131 | FOUNDATION F 126 PERIM 0 AREA 1916 | 1.00 | 0.006 | 0.006 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 612 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 138 | FOUNDATION F 126 PERIM 0 AREA 1916 | 1.00 | 0.006 | 0.006 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 618 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 797 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.62 | 270.00 | 90.00 | W |
| SURFACE 798 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.21 | 0.00 | 90.00 | N |
| SURFACE 998 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.17 | 0.00 | 90.00 | N |
| SURFACE 999 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.55 | 90.00 | 90.00 | E |
| SURFACE 819 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.21 | 0.00 | 90.00 | N |
| SURFACE 820 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.57 | 90.00 | 90.00 | E |
| SURFACE 977 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 58.58 | 40.58 | 270.00 | 90.00 | W |
| SURFACE 978 | TYPICAL INSULATED STEEL FRAMED EXTERIOR WALL R-11.9 | 0.30 | 0.477 | 0.514 | 72.46 | 50.17 | 0.00 | 90.00 | N |
| SURFACE 69 | FOUNDATION F 126 PERIM 0 AREA 818 | 1.00 | 0.006 | 0.006 | 8.18 | 8.18 | 0.00 | 180.00 | |
| SURFACE 546 | TYPICAL IEAD ROOF - HIGHLY REFLECTIVE R-25.64 | 0.55 | 0.221 | 0.228 | 8.18 | 8.18 | 0.00 | 0.00 |
| Construction | Reflectance | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Net Area [m2] | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| SURFACE 1137 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 2 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 3 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 4 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 50.73 | 50.73 | 0.00 | 90.00 | N |
| SURFACE 5 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 1129 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 222 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 65 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 66 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 8 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 0.00 | |
| SURFACE 778 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 779 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 0.00 | 90.00 | N |
| SURFACE 780 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 776 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 782 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 958 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 0.00 | 90.00 | N |
| SURFACE 959 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 962 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 957 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 963 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 449 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 0.00 | 90.00 | N |
| SURFACE 450 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 454 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 1122 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 448 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 771 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 772 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 774 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 770 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 954 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 775 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 786 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 787 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 814 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 784 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 1126 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 933 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 483 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 484 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 486 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 46 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 482 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 765 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 766 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 0.00 | 90.00 | N |
| SURFACE 767 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 0.00 | 90.00 | N |
| SURFACE 768 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 45 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 763 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 769 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 752 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 753 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 0.00 | 90.00 | N |
| SURFACE 754 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 0.00 | 90.00 | N |
| SURFACE 755 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 750 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 218 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 783 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 490 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 491 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 492 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 90.00 | 90.00 | E |
| SURFACE 493 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 1118 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 488 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 757 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 758 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 760 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 761 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 756 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 762 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 209 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 41 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 747 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 748 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 208 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 214 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 517 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 518 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 520 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 521 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 217 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 516 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 730 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 731 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 732 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 90.00 | 90.00 | E |
| SURFACE 733 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 728 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 734 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 504 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 505 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 506 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 90.00 | 90.00 | E |
| SURFACE 507 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 502 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 508 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 525 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 526 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 527 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 219 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 523 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 702 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 0.00 | 90.00 | N |
| SURFACE 703 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 705 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 706 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 0.00 | 90.00 | N |
| SURFACE 40 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 701 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 707 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 298 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 299 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 0.00 | 90.00 | N |
| SURFACE 300 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 0.00 | 90.00 | N |
| SURFACE 452 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 296 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 225 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 501 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 531 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 532 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 0.00 | 90.00 | N |
| SURFACE 533 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 1117 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 529 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 697 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 698 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 699 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 42 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 180.00 | |
| SURFACE 43 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 180.00 | |
| SURFACE 700 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 272 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 273 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 0.00 | 90.00 | N |
| SURFACE 274 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 270 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 1 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 275 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 689 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 0.00 | 90.00 | N |
| SURFACE 690 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 693 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 688 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 694 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 266 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 267 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 0.00 | 90.00 | N |
| SURFACE 268 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 263 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 180.00 | |
| SURFACE 269 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 100 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 101 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 0.00 | 90.00 | N |
| SURFACE 97 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 98 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 99 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 102 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 30.66 | 30.66 | 0.00 | 0.00 | |
| SURFACE 68 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 15.33 | 15.33 | 0.00 | 0.00 | |
| SURFACE 854 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 855 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 856 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 857 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 853 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 30.66 | 30.66 | 0.00 | 180.00 | |
| SURFACE 858 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 30.66 | 30.66 | 0.00 | 0.00 | |
| SURFACE 1017 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 1018 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 1019 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 1020 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 1016 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 30.66 | 30.66 | 0.00 | 180.00 | |
| SURFACE 1021 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 30.66 | 30.66 | 90.00 | 0.00 | |
| SURFACE 575 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 576 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 577 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 578 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 574 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 30.66 | 30.66 | 0.00 | 180.00 | |
| SURFACE 537 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 538 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 180.00 | 90.00 | S |
| SURFACE 539 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 270.00 | 90.00 | W |
| SURFACE 540 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 695 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 741 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 515 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 31.59 | 31.59 | 0.00 | 180.00 | |
| SURFACE 742 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 31.59 | 31.59 | 0.00 | 0.00 | |
| SURFACE 232 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 984 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 985 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 180.00 | 90.00 | S |
| SURFACE 986 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 987 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 988 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 989 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 180.00 | 90.00 | S |
| SURFACE 990 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 991 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 992 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 993 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 994 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 995 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 983 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 61.32 | 61.32 | 0.00 | 180.00 | |
| SURFACE 996 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 61.32 | 61.32 | 0.00 | 0.00 | |
| SURFACE 10 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 11 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 12 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 13 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 14 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 15 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 16 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 50.73 | 50.73 | 0.00 | 90.00 | N |
| SURFACE 17 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 18 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 50.73 | 50.73 | 180.00 | 90.00 | S |
| SURFACE 19 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 20 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 21 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 22 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 226 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 90.00 | 90.00 | E |
| SURFACE 24 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 25 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 180.00 | 90.00 | S |
| SURFACE 9 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 1123 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 92.90 | 92.90 | 180.00 | 0.00 | |
| SURFACE 28 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 0.00 | |
| SURFACE 709 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 710 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 711 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 180.00 | 90.00 | S |
| SURFACE 712 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 713 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 714 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 715 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 717 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 718 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 180.00 | 90.00 | S |
| SURFACE 719 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 270.00 | 90.00 | W |
| SURFACE 720 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 721 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 180.00 | 90.00 | S |
| SURFACE 722 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 723 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 724 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 725 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 726 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 708 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 92.90 | 92.90 | 0.00 | 180.00 | |
| SURFACE 1116 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 31.59 | 31.59 | 0.00 | 0.00 | |
| SURFACE 727 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 61.32 | 61.32 | 0.00 | 0.00 | |
| SURFACE 457 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 458 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 459 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 461 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 462 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 180.00 | 90.00 | S |
| SURFACE 463 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 270.00 | 90.00 | W |
| SURFACE 464 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 465 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 466 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 180.00 | 90.00 | S |
| SURFACE 467 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 468 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 0.00 | 90.00 | N |
| SURFACE 469 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 470 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 0.00 | 90.00 | N |
| SURFACE 471 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 472 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 473 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 474 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 475 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 476 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 0.00 | 90.00 | N |
| SURFACE 477 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 478 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 180.00 | 90.00 | S |
| SURFACE 479 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 480 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 1119 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 180.00 | |
| SURFACE 1120 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 31.59 | 31.59 | 0.00 | 180.00 | |
| SURFACE 1121 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 180.00 | |
| SURFACE 456 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 61.32 | 61.32 | 0.00 | 180.00 | |
| SURFACE 1138 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 8.45 | 8.45 | 90.00 | 90.00 | E |
| SURFACE 228 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 229 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 230 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 231 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 67 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 928 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 929 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 931 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 927 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 932 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1111 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1112 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1113 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1109 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1114 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 683 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 684 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 686 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 682 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 923 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 924 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 925 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 921 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 926 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1105 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1106 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1107 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1103 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1108 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 90.00 | 0.00 | |
| SURFACE 678 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 679 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 680 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 676 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 916 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 917 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 919 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 915 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 920 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1099 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1100 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1101 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1097 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1102 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 671 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 672 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 674 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 670 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 911 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 912 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 913 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 909 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 914 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1093 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1094 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1095 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1091 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1096 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 666 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 667 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 668 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 664 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 904 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 905 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 907 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 903 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 908 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1087 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1088 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1089 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1085 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1090 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 90.00 | 0.00 | |
| SURFACE 659 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 660 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 662 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 658 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 899 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 900 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 901 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 897 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 902 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1081 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1082 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1083 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1079 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1084 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 654 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 655 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 656 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 652 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 892 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 893 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 895 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 891 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 896 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1075 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1076 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1077 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1073 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1078 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 90.00 | 0.00 | |
| SURFACE 647 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 648 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 650 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 646 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 886 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 887 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 888 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 11.63 | 11.63 | 270.00 | 90.00 | W |
| SURFACE 889 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 2.86 | 2.86 | 270.00 | 90.00 | W |
| SURFACE 884 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 890 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 1068 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 1069 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 1071 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 1067 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 1072 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 90.00 | 0.00 | |
| SURFACE 642 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 643 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 644 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 640 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 180.00 | |
| SURFACE 860 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 861 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 862 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 863 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 859 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 864 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 1043 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 1044 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 1045 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 1046 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 1042 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 1047 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 635 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 636 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 637 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 638 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 634 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 879 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 880 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 881 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 882 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 878 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 883 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 1062 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 1063 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 1064 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 1065 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 1061 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 1066 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 601 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 602 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 603 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 604 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 600 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 180.00 | |
| SURFACE 561 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 58.58 | 58.58 | 90.00 | 90.00 | E |
| SURFACE 562 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 180.00 | 90.00 | S |
| SURFACE 563 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 559 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 568 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 569 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 570 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 571 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 572 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 58.58 | 58.58 | 270.00 | 90.00 | W |
| SURFACE 566 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 620 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 58.58 | 58.58 | 90.00 | 90.00 | E |
| SURFACE 621 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 622 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 623 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 624 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 619 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 628 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 629 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 180.00 | 90.00 | S |
| SURFACE 630 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 58.58 | 58.58 | 270.00 | 90.00 | W |
| SURFACE 627 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 146 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 147 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 50.73 | 50.73 | 180.00 | 90.00 | S |
| SURFACE 148 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 149 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 150 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 152 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 261 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 58 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 270.00 | 90.00 | W |
| SURFACE 59 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 50.73 | 50.73 | 0.00 | 90.00 | N |
| SURFACE 60 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 1125 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 212 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 224 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 63 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 37.63 | 37.63 | 0.00 | 0.00 | |
| SURFACE 88 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 89 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 50.73 | 50.73 | 180.00 | 90.00 | S |
| SURFACE 90 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 93 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 94 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 64 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 95 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 30 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 31 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 0.00 | 90.00 | N |
| SURFACE 32 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 34 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.58 | 18.58 | 0.00 | 0.00 | |
| SURFACE 736 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 737 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 0.00 | 90.00 | N |
| SURFACE 738 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 735 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.58 | 18.58 | 0.00 | 180.00 | |
| SURFACE 740 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.58 | 18.58 | 0.00 | 0.00 | |
| SURFACE 511 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 512 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 0.00 | 90.00 | N |
| SURFACE 513 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 509 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.58 | 18.58 | 0.00 | 180.00 | |
| SURFACE 514 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.58 | 18.58 | 0.00 | 0.00 | |
| SURFACE 496 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 497 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 0.00 | 90.00 | N |
| SURFACE 498 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 495 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 18.58 | 18.58 | 0.00 | 180.00 | |
| SURFACE 203 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 204 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 206 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 207 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 198 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 199 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 200 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 201 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 191 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 192 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 194 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 195 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 186 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 187 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 188 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 189 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 179 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 180 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 182 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 183 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 174 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 175 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 176 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 177 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 167 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 168 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 170 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 171 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 162 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 163 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 180.00 | 90.00 | S |
| SURFACE 164 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 165 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.26 | 12.26 | 0.00 | 0.00 | |
| SURFACE 104 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 105 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 106 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 107 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 108 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 109 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 110 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 111 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 112 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 113 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 114 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 115 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 116 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 180.00 | 90.00 | S |
| SURFACE 117 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 3.62 | 3.62 | 180.00 | 90.00 | S |
| SURFACE 118 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 119 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 120 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 121 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 122 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 123 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 180.00 | 90.00 | S |
| SURFACE 124 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 194.17 | 194.17 | 180.00 | 0.00 | |
| SURFACE 834 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 835 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 836 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 837 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 838 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 839 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 840 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 841 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 842 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 843 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 844 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 845 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 846 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 847 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 848 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 849 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 850 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 851 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 1115 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 15.33 | 15.33 | 0.00 | 180.00 | |
| SURFACE 833 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 194.17 | 194.17 | 0.00 | 180.00 | |
| SURFACE 852 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 209.50 | 209.50 | 180.00 | 0.00 | |
| SURFACE 1023 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 1024 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1025 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1026 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1027 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1028 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1029 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1030 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1031 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 1032 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 1033 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 1034 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 1035 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 1036 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 1037 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 1038 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 1039 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 1040 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 1022 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 209.50 | 209.50 | 0.00 | 180.00 | |
| SURFACE 1041 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 209.50 | 209.50 | 180.00 | 0.00 | |
| SURFACE 581 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 582 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 583 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 584 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 585 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 586 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 587 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 588 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 589 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 0.00 | 90.00 | N |
| SURFACE 590 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 591 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 592 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 593 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 594 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 595 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 596 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 180.00 | 90.00 | S |
| SURFACE 597 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 598 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 180.00 | 90.00 | S |
| SURFACE 580 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 209.50 | 209.50 | 0.00 | 180.00 | |
| SURFACE 36 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 38 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 39 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 233 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 11.89 | 11.89 | 0.00 | 0.00 | |
| SURFACE 943 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 944 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 945 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 234 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 11.89 | 11.89 | 0.00 | 180.00 | |
| SURFACE 235 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 11.89 | 11.89 | 0.00 | 0.00 | |
| SURFACE 213 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 215 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 216 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 236 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 11.89 | 11.89 | 0.00 | 180.00 | |
| SURFACE 237 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 11.89 | 11.89 | 0.00 | 0.00 | |
| SURFACE 939 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 940 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 941 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 90.00 | 90.00 | E |
| SURFACE 238 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 11.89 | 11.89 | 0.00 | 180.00 | |
| SURFACE 76 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 77 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 78 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 80 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 809 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 810 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 811 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 808 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 813 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 965 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 967 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 968 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 964 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 969 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 548 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 549 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 550 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 547 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 82 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 83 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 84 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 86 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 828 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 829 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 830 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 827 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 832 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 1012 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 1013 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 1014 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 1010 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 1015 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 0.00 | |
| SURFACE 554 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 555 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 556 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 0.00 | 90.00 | N |
| SURFACE 553 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 12.54 | 12.54 | 0.00 | 180.00 | |
| SURFACE 154 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 155 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 156 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 157 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 3.62 | 3.62 | 0.00 | 90.00 | N |
| SURFACE 158 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 12.08 | 12.08 | 0.00 | 90.00 | N |
| SURFACE 159 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 126 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 127 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 0.00 | 90.00 | N |
| SURFACE 128 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 90.00 | 90.00 | E |
| SURFACE 129 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.70 | 15.70 | 180.00 | 90.00 | S |
| SURFACE 130 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 9.96 | 9.96 | 0.00 | 0.00 | |
| SURFACE 52 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.32 | 19.32 | 270.00 | 90.00 | W |
| SURFACE 53 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 54 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 36.23 | 36.23 | 0.00 | 90.00 | N |
| SURFACE 55 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 32.61 | 32.61 | 90.00 | 90.00 | E |
| SURFACE 223 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 18.81 | 18.81 | 0.00 | 0.00 | |
| SURFACE 56 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 56.44 | 56.44 | 0.00 | 0.00 | |
| SURFACE 132 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 133 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 134 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 135 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 136 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 137 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 866 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 867 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 868 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 869 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 870 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 865 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 871 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 1049 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 1050 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 1051 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 1052 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 1053 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 1048 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 1054 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 607 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 608 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 609 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 610 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 611 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.96 | 9.96 | 270.00 | 90.00 | W |
| SURFACE 606 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 139 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 140 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 141 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 142 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 143 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 873 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 874 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 875 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 876 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 872 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 877 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 1056 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 1057 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 1058 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 1059 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 1055 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 1060 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 0.00 | |
| SURFACE 614 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 180.00 | 90.00 | S |
| SURFACE 615 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 616 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 15.10 | 15.10 | 0.00 | 90.00 | N |
| SURFACE 617 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 613 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 19.16 | 19.16 | 0.00 | 180.00 | |
| SURFACE 795 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 796 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 799 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 2.86 | 2.86 | 90.00 | 90.00 | E |
| SURFACE 800 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 11.63 | 11.63 | 90.00 | 90.00 | E |
| SURFACE 801 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 802 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 803 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 804 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 180.00 | 90.00 | S |
| SURFACE 805 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 806 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 180.00 | 90.00 | S |
| SURFACE 794 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 955 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 180.00 | |
| SURFACE 956 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 807 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 299.61 | 299.61 | 0.00 | 0.00 | |
| SURFACE 1000 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 1001 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 1002 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 180.00 | 90.00 | S |
| SURFACE 1003 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 1004 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 180.00 | 90.00 | S |
| SURFACE 1005 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 1006 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 1007 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 1008 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 997 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 299.61 | 299.61 | 0.00 | 180.00 | |
| SURFACE 1009 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 0.00 | |
| SURFACE 1130 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 220 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 815 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 816 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 270.00 | 90.00 | W |
| SURFACE 817 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 270.00 | 90.00 | W |
| SURFACE 818 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 270.00 | 90.00 | W |
| SURFACE 821 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 822 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 823 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 180.00 | 90.00 | S |
| SURFACE 824 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 825 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 180.00 | 90.00 | S |
| SURFACE 47 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 48 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 180.00 | |
| SURFACE 49 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 180.00 | |
| SURFACE 826 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 299.61 | 299.61 | 180.00 | 0.00 | |
| SURFACE 971 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 90.00 | 90.00 | E |
| SURFACE 972 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 18.12 | 18.12 | 180.00 | 90.00 | S |
| SURFACE 973 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 27.17 | 27.17 | 180.00 | 90.00 | S |
| SURFACE 974 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 5.43 | 5.43 | 180.00 | 90.00 | S |
| SURFACE 975 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.06 | 9.06 | 270.00 | 90.00 | W |
| SURFACE 976 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 21.74 | 21.74 | 180.00 | 90.00 | S |
| SURFACE 979 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 14.49 | 14.49 | 90.00 | 90.00 | E |
| SURFACE 980 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 24.15 | 24.15 | 90.00 | 90.00 | E |
| SURFACE 981 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 19.93 | 19.93 | 90.00 | 90.00 | E |
| SURFACE 970 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 299.61 | 299.61 | 0.00 | 180.00 | |
| SURFACE 1127 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 1128 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 135.17 | 135.17 | 0.00 | 0.00 | |
| SURFACE 982 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 29.26 | 29.26 | 0.00 | 0.00 | |
| SURFACE 70 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 71 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 72 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 73 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 74 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 8.18 | 8.18 | 0.00 | 0.00 | |
| SURFACE 789 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 790 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 791 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 792 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 788 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 8.18 | 8.18 | 0.00 | 180.00 | |
| SURFACE 793 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 8.18 | 8.18 | 0.00 | 0.00 | |
| SURFACE 1132 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 1133 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 1134 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 1135 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 1131 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 8.18 | 8.18 | 0.00 | 180.00 | |
| SURFACE 1136 | TYPICAL INTERIOR CEILING | 0.30 | 1.887 | 3.839 | 8.18 | 8.18 | 0.00 | 0.00 | |
| SURFACE 542 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 90.00 | 90.00 | E |
| SURFACE 543 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 180.00 | 90.00 | S |
| SURFACE 544 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 13.29 | 13.29 | 270.00 | 90.00 | W |
| SURFACE 545 | UNINSULATED STEEL STUD WALL | 1.00 | 2.814 | 8.630 | 9.66 | 9.66 | 0.00 | 90.00 | N |
| SURFACE 541 | TYPICAL INTERIOR FLOOR | 0.30 | 1.887 | 3.839 | 8.18 | 8.18 | 0.00 | 180.00 | |
| CB_CAFE_STUDY_LOUNGE_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 359.53 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_1_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_1_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_2_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_2_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_3_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_3_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_3_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_4_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_4_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_4_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_5_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_5_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_5_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_6_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_6_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_6_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_7_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_7_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_8_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CLASSROOM_8_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 112.88 | 0.00 | 90.00 | N | ||
| CB_CONFERENCE_ROOM_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 91.97 | 0.00 | 90.00 | N | ||
| CB_CONFERENCE_ROOM_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 61.32 | 0.00 | 90.00 | N | ||
| CB_CONFERENCE_ROOM_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 61.32 | 0.00 | 90.00 | N | ||
| CB_CONFERENCE_ROOM_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 61.32 | 0.00 | 90.00 | N | ||
| CB_CORRIDOR_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 63.17 | 0.00 | 90.00 | N | ||
| CB_CORRIDOR_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 122.63 | 0.00 | 90.00 | N | ||
| CB_CORRIDOR_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 244.33 | 0.00 | 90.00 | N | ||
| CB_CORRIDOR_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 185.81 | 0.00 | 90.00 | N | ||
| CB_CORRIDOR_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 302.86 | 0.00 | 90.00 | N | ||
| CB_ENTRANCE_LOBBY_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_1_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_1_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_2_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_2_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_3_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_3_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_3_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_4_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_4_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_4_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_5_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_5_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_5_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_6_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_6_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_6_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_7_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_7_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_7_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_8_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_8_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_OFFICE_8_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_FACULTY_RESTROOMS_1_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_FACULTY_RESTROOMS_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_FACULTY_RESTROOMS_1_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_FACULTY_RESTROOMS_2_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_FACULTY_RESTROOMS_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_FACULTY_RESTROOMS_2_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_LAB_1_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 270.35 | 0.00 | 90.00 | N | ||
| CB_LAB_2_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 270.35 | 0.00 | 90.00 | N | ||
| CB_LAB_3_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 270.35 | 0.00 | 90.00 | N | ||
| CB_LAB_4_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 270.35 | 0.00 | 90.00 | N | ||
| CB_LECTURE_ROOM_1_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 540.70 | 0.00 | 90.00 | N | ||
| CB_LECTURE_ROOM_2_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 301.01 | 0.00 | 90.00 | N | ||
| CB_LIBRARY_MEDIA_CENTER_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 540.70 | 0.00 | 90.00 | N | ||
| CB_MAIN_STAIRS_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 37.16 | 0.00 | 90.00 | N | ||
| CB_MAIN_STAIRS_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 37.16 | 0.00 | 90.00 | N | ||
| CB_MAIN_STAIRS_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 37.16 | 0.00 | 90.00 | N | ||
| CB_MAIN_STAIRS_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 37.16 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_1_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_2_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_3_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_4_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_5_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_6_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_7_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_ENCLOSED_8_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 24.53 | 0.00 | 90.00 | N | ||
| CB_OFFICES_OPEN_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 388.33 | 0.00 | 90.00 | N | ||
| CB_OFFICES_OPEN_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 418.99 | 0.00 | 90.00 | N | ||
| CB_OFFICES_OPEN_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 418.99 | 0.00 | 90.00 | N | ||
| CB_OFFICES_OPEN_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 418.99 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_1_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_1_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_1_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_2_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_2_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_SECONDARY_STAIRS_2_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 25.08 | 0.00 | 90.00 | N | ||
| CB_STAFF_RESTROOMS_1_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_STAFF_RESTROOMS_2_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 19.93 | 0.00 | 90.00 | N | ||
| CB_STORAGE_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 150.50 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_1_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_1_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_1_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_2_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_2_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDENTS_RESTROOMS_2_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 38.32 | 0.00 | 90.00 | N | ||
| CB_STUDIO_1_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 599.22 | 0.00 | 90.00 | N | ||
| CB_STUDIO_1_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 599.22 | 0.00 | 90.00 | N | ||
| CB_STUDIO_2_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 599.22 | 0.00 | 90.00 | N | ||
| CB_STUDIO_2_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 599.22 | 0.00 | 90.00 | N | ||
| CB_UTILITY_F1 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 16.35 | 0.00 | 90.00 | N | ||
| CB_UTILITY_F2 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 16.35 | 0.00 | 90.00 | N | ||
| CB_UTILITY_F3 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 16.35 | 0.00 | 90.00 | N | ||
| CB_UTILITY_F4 MASS | INTERIORFURNISHINGS | 0.30 | 0.800 | 16.35 | 0.00 | 90.00 | N |
| Construction | Frame and Divider | Glass Area [m2] | Frame Area [m2] | Divider Area [m2] | Area of One Opening [m2] | Area of Multiplied Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Frame Conductance [W/m2-K] | Divider Conductance [W/m2-K] | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | Shade Control | Parent Surface | Azimuth [deg] | Tilt [deg] | Cardinal Direction | |
| SUB SURFACE 58 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.29 | 0.00 | 0.00 | 22.29 | 22.29 | 4.375 | 0.235 | 0.102 | No | SURFACE 6 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 12 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.00 | 0.00 | 0.00 | 10.00 | 10.00 | 4.375 | 0.235 | 0.102 | No | SURFACE 7 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 23 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.30 | 0.00 | 0.00 | 8.30 | 8.30 | 4.375 | 0.235 | 0.102 | No | SURFACE 777 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 40 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 9.99 | 0.00 | 0.00 | 9.99 | 9.99 | 4.375 | 0.235 | 0.102 | No | SURFACE 781 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 100 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.03 | 0.00 | 0.00 | 10.03 | 10.03 | 4.375 | 0.235 | 0.102 | No | SURFACE 960 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 97 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 961 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 33 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.12 | 0.00 | 0.00 | 11.12 | 11.12 | 4.375 | 0.235 | 0.102 | No | SURFACE 451 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 10 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.01 | 0.00 | 0.00 | 10.01 | 10.01 | 4.375 | 0.235 | 0.102 | No | SURFACE 453 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 22 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.32 | 0.00 | 0.00 | 8.32 | 8.32 | 4.375 | 0.235 | 0.102 | No | SURFACE 773 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 94 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 785 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 34 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.12 | 0.00 | 0.00 | 11.12 | 11.12 | 4.375 | 0.235 | 0.102 | No | SURFACE 485 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 21 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.32 | 0.00 | 0.00 | 8.32 | 8.32 | 4.375 | 0.235 | 0.102 | No | SURFACE 764 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 91 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 751 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 35 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.11 | 0.00 | 0.00 | 11.11 | 11.11 | 4.375 | 0.235 | 0.102 | No | SURFACE 489 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 20 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.30 | 0.00 | 0.00 | 8.30 | 8.30 | 4.375 | 0.235 | 0.102 | No | SURFACE 759 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 88 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 744 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 36 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.11 | 0.00 | 0.00 | 11.11 | 11.11 | 4.375 | 0.235 | 0.102 | No | SURFACE 519 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 16 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.31 | 0.00 | 0.00 | 8.31 | 8.31 | 4.375 | 0.235 | 0.102 | No | SURFACE 729 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 76 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.35 | 0.00 | 0.00 | 8.35 | 8.35 | 4.375 | 0.235 | 0.102 | No | SURFACE 503 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 37 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.13 | 0.00 | 0.00 | 11.13 | 11.13 | 4.375 | 0.235 | 0.102 | No | SURFACE 524 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 15 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.27 | 0.00 | 0.00 | 8.27 | 8.27 | 4.375 | 0.235 | 0.102 | No | SURFACE 704 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 75 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 297 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 38 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.13 | 0.00 | 0.00 | 11.13 | 11.13 | 4.375 | 0.235 | 0.102 | No | SURFACE 530 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 66 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.03 | 0.00 | 0.00 | 10.03 | 10.03 | 4.375 | 0.235 | 0.102 | No | SURFACE 534 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 14 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.25 | 0.00 | 0.00 | 8.25 | 8.25 | 4.375 | 0.235 | 0.102 | No | SURFACE 696 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 73 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 271 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 13 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.30 | 0.00 | 0.00 | 8.30 | 8.30 | 4.375 | 0.235 | 0.102 | No | SURFACE 691 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 9 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.01 | 0.00 | 0.00 | 10.01 | 10.01 | 4.375 | 0.235 | 0.102 | No | SURFACE 692 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 70 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 8.36 | 0.00 | 0.00 | 8.36 | 8.36 | 4.375 | 0.235 | 0.102 | No | SURFACE 264 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 67 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.03 | 0.00 | 0.00 | 10.03 | 10.03 | 4.375 | 0.235 | 0.102 | No | SURFACE 265 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 82 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.72 | 0.00 | 0.00 | 3.72 | 3.72 | 4.375 | 0.235 | 0.102 | No | SURFACE 536 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 29 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.69 | 0.00 | 0.00 | 3.69 | 3.69 | 4.375 | 0.235 | 0.102 | No | SURFACE 23 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 18 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.69 | 0.00 | 0.00 | 3.69 | 3.69 | 4.375 | 0.235 | 0.102 | No | SURFACE 716 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 27 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.69 | 0.00 | 0.00 | 3.69 | 3.69 | 4.375 | 0.235 | 0.102 | No | SURFACE 460 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 60 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.14 | 0.00 | 0.00 | 11.14 | 11.14 | 4.375 | 0.235 | 0.102 | No | SURFACE 227 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 44 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 930 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 7 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 1110 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 78 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.07 | 0.00 | 0.00 | 4.07 | 4.07 | 4.375 | 0.235 | 0.102 | No | SURFACE 685 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 45 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.07 | 0.00 | 0.00 | 4.07 | 4.07 | 4.375 | 0.235 | 0.102 | No | SURFACE 922 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 11 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 1104 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 83 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 677 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 46 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.06 | 0.00 | 0.00 | 4.06 | 4.06 | 4.375 | 0.235 | 0.102 | No | SURFACE 918 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 25 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 1098 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 84 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 673 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 47 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.05 | 0.00 | 0.00 | 4.05 | 4.05 | 4.375 | 0.235 | 0.102 | No | SURFACE 910 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 28 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 1092 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 89 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 665 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 48 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.05 | 0.00 | 0.00 | 4.05 | 4.05 | 4.375 | 0.235 | 0.102 | No | SURFACE 906 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 31 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 1086 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 90 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 661 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 49 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.06 | 0.00 | 0.00 | 4.06 | 4.06 | 4.375 | 0.235 | 0.102 | No | SURFACE 898 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 39 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 1080 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 95 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 653 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 50 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.06 | 0.00 | 0.00 | 4.06 | 4.06 | 4.375 | 0.235 | 0.102 | No | SURFACE 894 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 57 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 1074 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 96 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 649 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 51 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.06 | 0.00 | 0.00 | 4.06 | 4.06 | 4.375 | 0.235 | 0.102 | No | SURFACE 885 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 59 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 1070 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 101 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.09 | 0.00 | 0.00 | 4.09 | 4.09 | 4.375 | 0.235 | 0.102 | No | SURFACE 641 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 56 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.12 | 0.00 | 0.00 | 11.12 | 11.12 | 4.375 | 0.235 | 0.102 | No | SURFACE 560 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 2 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 17.96 | 0.00 | 0.00 | 17.96 | 17.96 | 4.375 | 0.235 | 0.102 | No | SURFACE 564 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 55 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.12 | 0.00 | 0.00 | 11.12 | 11.12 | 4.375 | 0.235 | 0.102 | No | SURFACE 567 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 54 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.12 | 0.00 | 0.00 | 11.12 | 11.12 | 4.375 | 0.235 | 0.102 | No | SURFACE 625 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 53 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.08 | 0.00 | 0.00 | 11.08 | 11.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 631 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 72 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 18.02 | 0.00 | 0.00 | 18.02 | 18.02 | 4.375 | 0.235 | 0.102 | No | SURFACE 632 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 74 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 18.02 | 0.00 | 0.00 | 18.02 | 18.02 | 4.375 | 0.235 | 0.102 | No | SURFACE 145 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 77 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.29 | 0.00 | 0.00 | 22.29 | 22.29 | 4.375 | 0.235 | 0.102 | No | SURFACE 151 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 68 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 10.03 | 0.00 | 0.00 | 10.03 | 10.03 | 4.375 | 0.235 | 0.102 | No | SURFACE 61 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 65 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.30 | 0.00 | 0.00 | 22.30 | 22.30 | 4.375 | 0.235 | 0.102 | No | SURFACE 62 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 4 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 17.95 | 0.00 | 0.00 | 17.95 | 17.95 | 4.375 | 0.235 | 0.102 | No | SURFACE 91 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 104 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.29 | 0.00 | 0.00 | 22.29 | 22.29 | 4.375 | 0.235 | 0.102 | No | SURFACE 92 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 26 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.69 | 0.00 | 0.00 | 3.69 | 3.69 | 4.375 | 0.235 | 0.102 | No | SURFACE 33 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 17 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.66 | 0.00 | 0.00 | 3.66 | 3.66 | 4.375 | 0.235 | 0.102 | No | SURFACE 739 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 79 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.71 | 0.00 | 0.00 | 3.71 | 3.71 | 4.375 | 0.235 | 0.102 | No | SURFACE 510 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 24 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 3.66 | 0.00 | 0.00 | 3.66 | 3.66 | 4.375 | 0.235 | 0.102 | No | SURFACE 499 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 80 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 205 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 81 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 197 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 86 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 193 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 87 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 185 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 92 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 181 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 93 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 173 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 98 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.08 | 0.00 | 0.00 | 4.08 | 4.08 | 4.375 | 0.235 | 0.102 | No | SURFACE 169 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 99 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 4.07 | 0.00 | 0.00 | 4.07 | 4.07 | 4.375 | 0.235 | 0.102 | No | SURFACE 161 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 32 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.94 | 0.00 | 0.00 | 2.94 | 2.94 | 4.375 | 0.235 | 0.102 | No | SURFACE 37 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 19 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.94 | 0.00 | 0.00 | 2.94 | 2.94 | 4.375 | 0.235 | 0.102 | No | SURFACE 942 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 85 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.97 | 0.00 | 0.00 | 2.97 | 2.97 | 4.375 | 0.235 | 0.102 | No | SURFACE 211 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 30 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.94 | 0.00 | 0.00 | 2.94 | 2.94 | 4.375 | 0.235 | 0.102 | No | SURFACE 938 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 8 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.73 | 0.00 | 0.00 | 2.73 | 2.73 | 4.375 | 0.235 | 0.102 | No | SURFACE 79 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 5 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.72 | 0.00 | 0.00 | 2.72 | 2.72 | 4.375 | 0.235 | 0.102 | No | SURFACE 812 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 64 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.78 | 0.00 | 0.00 | 2.78 | 2.78 | 4.375 | 0.235 | 0.102 | No | SURFACE 966 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 6 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.73 | 0.00 | 0.00 | 2.73 | 2.73 | 4.375 | 0.235 | 0.102 | No | SURFACE 551 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 71 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.78 | 0.00 | 0.00 | 2.78 | 2.78 | 4.375 | 0.235 | 0.102 | No | SURFACE 85 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 41 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.75 | 0.00 | 0.00 | 2.75 | 2.75 | 4.375 | 0.235 | 0.102 | No | SURFACE 831 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 102 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.79 | 0.00 | 0.00 | 2.79 | 2.79 | 4.375 | 0.235 | 0.102 | No | SURFACE 1011 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 69 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 2.78 | 0.00 | 0.00 | 2.78 | 2.78 | 4.375 | 0.235 | 0.102 | No | SURFACE 557 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 62 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 11.13 | 0.00 | 0.00 | 11.13 | 11.13 | 4.375 | 0.235 | 0.102 | No | SURFACE 51 | 180.00 | 90.00 | S | |||||||
| SUB SURFACE 1 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 17.96 | 0.00 | 0.00 | 17.96 | 17.96 | 4.375 | 0.235 | 0.102 | No | SURFACE 797 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 52 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.25 | 0.00 | 0.00 | 22.25 | 22.25 | 4.375 | 0.235 | 0.102 | No | SURFACE 798 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 3 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.29 | 0.00 | 0.00 | 22.29 | 22.29 | 4.375 | 0.235 | 0.102 | No | SURFACE 998 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 103 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 18.02 | 0.00 | 0.00 | 18.02 | 18.02 | 4.375 | 0.235 | 0.102 | No | SURFACE 999 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 43 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.26 | 0.00 | 0.00 | 22.26 | 22.26 | 4.375 | 0.235 | 0.102 | No | SURFACE 819 | 0.00 | 90.00 | N | |||||||
| SUB SURFACE 42 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 18.01 | 0.00 | 0.00 | 18.01 | 18.01 | 4.375 | 0.235 | 0.102 | No | SURFACE 820 | 90.00 | 90.00 | E | |||||||
| SUB SURFACE 63 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 18.00 | 0.00 | 0.00 | 18.00 | 18.00 | 4.375 | 0.235 | 0.102 | No | SURFACE 977 | 270.00 | 90.00 | W | |||||||
| SUB SURFACE 61 | U 0.77 SHGC 0.23 SIMPLE GLAZING WINDOW U-0.77 SHGC 0.23 | 22.29 | 0.00 | 0.00 | 22.29 | 22.29 | 4.375 | 0.235 | 0.102 | No | SURFACE 978 | 0.00 | 90.00 | N | |||||||
| Total or Average | 862.81 | 4.375 | 0.235 | 0.102 | |||||||||||||||||
| North Total or Average | 308.61 | 4.375 | 0.235 | 0.102 | |||||||||||||||||
| Non-North Total or Average | 554.20 | 4.375 | 0.235 | 0.102 |
| Frame and Divider | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | NFRC Product Type | Assembly U-Factor [W/m2-K] | Assembly SHGC | Assembly Visible Transmittance | |
| None |
| Construction | Area of One Opening [m2] | Area of Openings [m2] | Glass U-Factor [W/m2-K] | Glass SHGC | Glass Visible Transmittance | Parent Surface | |
| Total or Average | 0.00 | - | - | - |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
| Construction | U-Factor with Film [W/m2-K] | U-Factor no Film [W/m2-K] | Gross Area [m2] | Parent Surface | |
| None |
Report: Shading Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Sunlit Fraction| March 21 9am | March 21 noon | March 21 3pm | June 21 9am | June 21 noon | June 21 3pm | December 21 9am | December 21 noon | December 21 3pm | |
| SUB SURFACE 58 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 12 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 23 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 40 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 100 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 97 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 33 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 10 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 22 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 94 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 34 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 21 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 91 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 35 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 20 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 88 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 36 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 16 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 76 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 37 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 15 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 75 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 38 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 66 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 14 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 73 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 13 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 9 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 70 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 67 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 82 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 29 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 18 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 27 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 60 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 44 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 7 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 78 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 45 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 11 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 83 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 46 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 25 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 84 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 47 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 28 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 89 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 48 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 31 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 90 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 49 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 39 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 95 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 50 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 57 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 96 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 51 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 59 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 101 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 56 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 2 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 55 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 54 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 53 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 72 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 74 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 77 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 68 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 65 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 4 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 104 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 26 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 17 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 79 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 24 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 80 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 81 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 86 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 87 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 92 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 93 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 98 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 99 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 32 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 19 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 85 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 30 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 8 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 5 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 64 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 6 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 71 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 41 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 102 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 69 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 62 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 |
| SUB SURFACE 1 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 52 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 3 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 103 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 43 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| SUB SURFACE 42 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 | 1.00 | 1.00 | 0.00 |
| SUB SURFACE 63 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 | 0.00 | 0.00 | 1.00 |
| SUB SURFACE 61 | 0.00 | 0.00 | 0.00 | 1.00 | 1.00 | 1.00 | 0.00 | 0.00 | 0.00 |
| Name | Type | Shaded Construction | Control | Glare Control | |
| None |
Report: Lighting Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Interior Lighting| Zone Name | Space Name | Space Type | Lighting Power Density [W/m2] | Space Area [m2] | Total Power [W] | End Use Subcategory | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Return Air Fraction | Conditioned (Y/N) | Consumption [GJ] | |
| CB_CAFE_STUDY_LOUNGE_F1 COLLEGE - LOUNGE LIGHTS | CB_CAFE_STUDY_LOUNGE_F1 ZN | CB_CAFE_STUDY_LOUNGE_F1 | COLLEGE - LOUNGE | 6.3507 | 179.77 | 1141.65 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 16.07 |
| CB_CLASSROOM_1_F4 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_1_F4 ZN | CB_CLASSROOM_1_F4 | COLLEGE - CLASSROOM | 7.6424 | 75.25 | 575.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 8.09 |
| CB_CLASSROOM_2_F4 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_2_F4 ZN | CB_CLASSROOM_2_F4 | COLLEGE - CLASSROOM | 7.6424 | 75.25 | 575.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 8.09 |
| CB_CLASSROOM_3_F4 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_3_F4 ZN | CB_CLASSROOM_3_F4 | COLLEGE - CLASSROOM | 7.6424 | 75.25 | 575.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 8.09 |
| CB_CLASSROOM_5_F4 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_5_F4 ZN | CB_CLASSROOM_5_F4 | COLLEGE - CLASSROOM | 7.6424 | 75.25 | 575.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 8.09 |
| CB_CLASSROOM_6_F4 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_6_F4 ZN | CB_CLASSROOM_6_F4 | COLLEGE - CLASSROOM | 7.6424 | 75.25 | 575.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 8.09 |
| CB_CLASSROOM_7_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_7_F2 ZN | CB_CLASSROOM_7_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_6_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_6_F2 ZN | CB_CLASSROOM_6_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_5_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_5_F2 ZN | CB_CLASSROOM_5_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_4_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_4_F3 ZN | CB_CLASSROOM_4_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_3_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_3_F3 ZN | CB_CLASSROOM_3_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.33 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_5_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_5_F3 ZN | CB_CLASSROOM_5_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_1_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_1_F3 ZN | CB_CLASSROOM_1_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_2_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_2_F3 ZN | CB_CLASSROOM_2_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_8_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_8_F2 ZN | CB_CLASSROOM_8_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_6_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_6_F3 ZN | CB_CLASSROOM_6_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_7_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_7_F3 ZN | CB_CLASSROOM_7_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_8_F3 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_8_F3 ZN | CB_CLASSROOM_8_F3 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_4_F4 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_4_F4 ZN | CB_CLASSROOM_4_F4 | COLLEGE - CLASSROOM | 7.6424 | 75.25 | 575.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 8.09 |
| CB_CLASSROOM_4_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_4_F2 ZN | CB_CLASSROOM_4_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_LECTURE_ROOM_2_F1 COLLEGE - CLASSROOM LIGHTS | CB_LECTURE_ROOM_2_F1 ZN | CB_LECTURE_ROOM_2_F1 | COLLEGE - CLASSROOM | 7.6424 | 150.50 | 1150.20 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 16.19 |
| CB_CLASSROOM_2_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_2_F2 ZN | CB_CLASSROOM_2_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_1_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_1_F2 ZN | CB_CLASSROOM_1_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CLASSROOM_3_F2 COLLEGE - CLASSROOM LIGHTS | CB_CLASSROOM_3_F2 ZN | CB_CLASSROOM_3_F2 | COLLEGE - CLASSROOM | 7.6424 | 56.44 | 431.32 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.07 |
| CB_CONFERENCE_ROOM_F4 COLLEGE - CONFERENCE LIGHTS | CB_CONFERENCE_ROOM_F4 ZN | CB_CONFERENCE_ROOM_F4 | COLLEGE - CONFERENCE | 10.4410 | 30.66 | 320.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 4.50 |
| CB_CONFERENCE_ROOM_F3 COLLEGE - CONFERENCE LIGHTS | CB_CONFERENCE_ROOM_F3 ZN | CB_CONFERENCE_ROOM_F3 | COLLEGE - CONFERENCE | 10.4410 | 30.66 | 320.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 4.50 |
| CB_CONFERENCE_ROOM_F1 COLLEGE - CONFERENCE LIGHTS | CB_CONFERENCE_ROOM_F1 ZN | CB_CONFERENCE_ROOM_F1 | COLLEGE - CONFERENCE | 10.4410 | 45.99 | 480.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 6.76 |
| CB_CONFERENCE_ROOM_F2 COLLEGE - CONFERENCE LIGHTS | CB_CONFERENCE_ROOM_F2 ZN | CB_CONFERENCE_ROOM_F2 | COLLEGE - CONFERENCE | 10.4410 | 30.66 | 320.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 4.50 |
| CB_CORRIDOR_F1 COLLEGE - CORRIDOR LIGHTS | CB_CORRIDOR_F1 ZN | CB_CORRIDOR_F1 | COLLEGE - CORRIDOR | 4.4132 | 122.17 | 539.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 7.59 |
| CB_CORRIDOR_F4 COLLEGE - CORRIDOR LIGHTS | CB_CORRIDOR_F4 ZN | CB_CORRIDOR_F4 | COLLEGE - CORRIDOR | 4.4132 | 151.43 | 668.30 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 9.40 |
| CB_CORRIDOR_F2 COLLEGE - CORRIDOR LIGHTS | CB_CORRIDOR_F2 ZN | CB_CORRIDOR_F2 | COLLEGE - CORRIDOR | 4.4132 | 92.90 | 410.00 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 5.77 |
| CB_CORRIDOR_2_F3 COLLEGE - CORRIDOR LIGHTS | CB_CORRIDOR_2_F3 ZN | CB_CORRIDOR_2_F3 | COLLEGE - CORRIDOR | 4.4132 | 61.32 | 270.60 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 3.81 |
| CB_CORRIDOR_1_F3 COLLEGE - CORRIDOR LIGHTS | CB_CORRIDOR_1_F3 ZN | CB_CORRIDOR_1_F3 | COLLEGE - CORRIDOR | 4.4132 | 31.59 | 139.40 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.96 |
| CB_OFFICES_ENCLOSED_8_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_8_F1 ZN | CB_OFFICES_ENCLOSED_8_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_7_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_7_F1 ZN | CB_OFFICES_ENCLOSED_7_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_5_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_5_F1 ZN | CB_OFFICES_ENCLOSED_5_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_4_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_4_F1 ZN | CB_OFFICES_ENCLOSED_4_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_6_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_6_F1 ZN | CB_OFFICES_ENCLOSED_6_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_OPEN_F4 COLLEGE - OFFICE LIGHTS | CB_OFFICES_OPEN_F4 ZN | CB_OFFICES_OPEN_F4 | COLLEGE - OFFICE | 7.9653 | 209.50 | 1668.70 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 23.48 |
| CB_OFFICES_OPEN_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_OPEN_F1 ZN | CB_OFFICES_OPEN_F1 | COLLEGE - OFFICE | 7.9653 | 194.17 | 1546.60 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 21.76 |
| CB_FACULTY_OFFICE_6_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_6_F4 ZN | CB_FACULTY_OFFICE_6_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_5_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_5_F4 ZN | CB_FACULTY_OFFICE_5_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_4_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_4_F4 ZN | CB_FACULTY_OFFICE_4_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_3_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_3_F4 ZN | CB_FACULTY_OFFICE_3_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_2_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_2_F4 ZN | CB_FACULTY_OFFICE_2_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_1_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_1_F1 ZN | CB_OFFICES_ENCLOSED_1_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_1_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_1_F4 ZN | CB_FACULTY_OFFICE_1_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_1_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_1_F3 ZN | CB_FACULTY_OFFICE_1_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_3_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_3_F2 ZN | CB_FACULTY_OFFICE_3_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_5_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_5_F3 ZN | CB_FACULTY_OFFICE_5_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_4_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_4_F3 ZN | CB_FACULTY_OFFICE_4_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_2_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_2_F3 ZN | CB_FACULTY_OFFICE_2_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_2_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_2_F1 ZN | CB_OFFICES_ENCLOSED_2_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_3_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_3_F3 ZN | CB_FACULTY_OFFICE_3_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_8_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_8_F4 ZN | CB_FACULTY_OFFICE_8_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_8_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_8_F3 ZN | CB_FACULTY_OFFICE_8_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_7_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_7_F3 ZN | CB_FACULTY_OFFICE_7_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_ENCLOSED_3_F1 COLLEGE - OFFICE LIGHTS | CB_OFFICES_ENCLOSED_3_F1 ZN | CB_OFFICES_ENCLOSED_3_F1 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_6_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_6_F2 ZN | CB_FACULTY_OFFICE_6_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_6_F3 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_6_F3 ZN | CB_FACULTY_OFFICE_6_F3 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_7_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_7_F2 ZN | CB_FACULTY_OFFICE_7_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_7_F4 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_7_F4 ZN | CB_FACULTY_OFFICE_7_F4 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_8_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_8_F2 ZN | CB_FACULTY_OFFICE_8_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_2_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_2_F2 ZN | CB_FACULTY_OFFICE_2_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_OPEN_F3 COLLEGE - OFFICE LIGHTS | CB_OFFICES_OPEN_F3 ZN | CB_OFFICES_OPEN_F3 | COLLEGE - OFFICE | 7.9653 | 209.50 | 1668.70 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 23.48 |
| CB_FACULTY_OFFICE_4_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_4_F2 ZN | CB_FACULTY_OFFICE_4_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_OFFICES_OPEN_F2 COLLEGE - OFFICE LIGHTS | CB_OFFICES_OPEN_F2 ZN | CB_OFFICES_OPEN_F2 | COLLEGE - OFFICE | 7.9653 | 209.50 | 1668.70 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 23.48 |
| CB_FACULTY_OFFICE_5_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_5_F2 ZN | CB_FACULTY_OFFICE_5_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_FACULTY_OFFICE_1_F2 COLLEGE - OFFICE LIGHTS | CB_FACULTY_OFFICE_1_F2 ZN | CB_FACULTY_OFFICE_1_F2 | COLLEGE - OFFICE | 7.9653 | 12.26 | 97.68 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.37 |
| CB_STUDENTS_RESTROOMS_1_F1 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_1_F1 ZN | CB_STUDENTS_RESTROOMS_1_F1 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_STAFF_RESTROOMS_1_F1 COLLEGE - RESTROOM LIGHTS | CB_STAFF_RESTROOMS_1_F1 ZN | CB_STAFF_RESTROOMS_1_F1 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_FACULTY_RESTROOMS_2_F4 COLLEGE - RESTROOM LIGHTS | CB_FACULTY_RESTROOMS_2_F4 ZN | CB_FACULTY_RESTROOMS_2_F4 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_STUDENTS_RESTROOMS_1_F4 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_1_F4 ZN | CB_STUDENTS_RESTROOMS_1_F4 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_STUDENTS_RESTROOMS_2_F4 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_2_F4 ZN | CB_STUDENTS_RESTROOMS_2_F4 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_FACULTY_RESTROOMS_1_F4 COLLEGE - RESTROOM LIGHTS | CB_FACULTY_RESTROOMS_1_F4 ZN | CB_FACULTY_RESTROOMS_1_F4 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_STUDENTS_RESTROOMS_1_F3 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_1_F3 ZN | CB_STUDENTS_RESTROOMS_1_F3 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_FACULTY_RESTROOMS_1_F3 COLLEGE - RESTROOM LIGHTS | CB_FACULTY_RESTROOMS_1_F3 ZN | CB_FACULTY_RESTROOMS_1_F3 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_STUDENTS_RESTROOMS_2_F3 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_2_F3 ZN | CB_STUDENTS_RESTROOMS_2_F3 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_FACULTY_RESTROOMS_2_F3 COLLEGE - RESTROOM LIGHTS | CB_FACULTY_RESTROOMS_2_F3 ZN | CB_FACULTY_RESTROOMS_2_F3 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_STAFF_RESTROOMS_2_F1 COLLEGE - RESTROOM LIGHTS | CB_STAFF_RESTROOMS_2_F1 ZN | CB_STAFF_RESTROOMS_2_F1 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_FACULTY_RESTROOMS_2_F2 COLLEGE - RESTROOM LIGHTS | CB_FACULTY_RESTROOMS_2_F2 ZN | CB_FACULTY_RESTROOMS_2_F2 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_FACULTY_RESTROOMS_1_F2 COLLEGE - RESTROOM LIGHTS | CB_FACULTY_RESTROOMS_1_F2 ZN | CB_FACULTY_RESTROOMS_1_F2 | COLLEGE - RESTROOM | 6.7813 | 9.96 | 67.57 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.95 |
| CB_STUDENTS_RESTROOMS_2_F1 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_2_F1 ZN | CB_STUDENTS_RESTROOMS_2_F1 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_STUDENTS_RESTROOMS_2_F2 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_2_F2 ZN | CB_STUDENTS_RESTROOMS_2_F2 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_STUDENTS_RESTROOMS_1_F2 COLLEGE - RESTROOM LIGHTS | CB_STUDENTS_RESTROOMS_1_F2 ZN | CB_STUDENTS_RESTROOMS_1_F2 | COLLEGE - RESTROOM | 6.7813 | 19.16 | 129.94 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.83 |
| CB_LAB_3_F4 COLLEGE - LABORATORY LIGHTS | CB_LAB_3_F4 ZN | CB_LAB_3_F4 | COLLEGE - LABORATORY | 14.3160 | 135.17 | 1935.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 27.23 |
| CB_LAB_4_F4 COLLEGE - LABORATORY LIGHTS | CB_LAB_4_F4 ZN | CB_LAB_4_F4 | COLLEGE - LABORATORY | 14.3160 | 135.17 | 1935.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 27.23 |
| CB_LAB_1_F4 COLLEGE - LABORATORY LIGHTS | CB_LAB_1_F4 ZN | CB_LAB_1_F4 | COLLEGE - LABORATORY | 14.3160 | 135.17 | 1935.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 27.23 |
| CB_LAB_2_F4 COLLEGE - LABORATORY LIGHTS | CB_LAB_2_F4 ZN | CB_LAB_2_F4 | COLLEGE - LABORATORY | 14.3160 | 135.17 | 1935.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 27.23 |
| CB_LECTURE_ROOM_1_F1 COLLEGE - LECTURE HALL LIGHTS | CB_LECTURE_ROOM_1_F1 ZN | CB_LECTURE_ROOM_1_F1 | COLLEGE - LECTURE HALL | 6.5660 | 270.35 | 1775.10 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 24.98 |
| CB_LIBRARY_MEDIA_CENTER_F1 COLLEGE - MEDIA CENTER LIGHTS | CB_LIBRARY_MEDIA_CENTER_F1 ZN | CB_LIBRARY_MEDIA_CENTER_F1 | COLLEGE - MEDIA CENTER | 8.9340 | 270.35 | 2415.30 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 33.99 |
| CB_MAIN_STAIRS_F4 COLLEGE - STAIRS LIGHTS | CB_MAIN_STAIRS_F4 ZN | CB_MAIN_STAIRS_F4 | COLLEGE - STAIRS | 5.2743 | 18.58 | 98.00 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.38 |
| CB_SECONDARY_STAIRS_2_F4 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_2_F4 ZN | CB_SECONDARY_STAIRS_2_F4 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_SECONDARY_STAIRS_2_F1 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_2_F1 ZN | CB_SECONDARY_STAIRS_2_F1 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_SECONDARY_STAIRS_1_F4 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_1_F4 ZN | CB_SECONDARY_STAIRS_1_F4 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_MAIN_STAIRS_F3 COLLEGE - STAIRS LIGHTS | CB_MAIN_STAIRS_F3 ZN | CB_MAIN_STAIRS_F3 | COLLEGE - STAIRS | 5.2743 | 18.58 | 98.00 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.38 |
| CB_MAIN_STAIRS_F2 COLLEGE - STAIRS LIGHTS | CB_MAIN_STAIRS_F2 ZN | CB_MAIN_STAIRS_F2 | COLLEGE - STAIRS | 5.2743 | 18.58 | 98.00 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.38 |
| CB_SECONDARY_STAIRS_2_F2 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_2_F2 ZN | CB_SECONDARY_STAIRS_2_F2 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_SECONDARY_STAIRS_2_F3 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_2_F3 ZN | CB_SECONDARY_STAIRS_2_F3 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_SECONDARY_STAIRS_1_F1 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_1_F1 ZN | CB_SECONDARY_STAIRS_1_F1 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_SECONDARY_STAIRS_1_F3 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_1_F3 ZN | CB_SECONDARY_STAIRS_1_F3 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_SECONDARY_STAIRS_1_F2 COLLEGE - STAIRS LIGHTS | CB_SECONDARY_STAIRS_1_F2 ZN | CB_SECONDARY_STAIRS_1_F2 | COLLEGE - STAIRS | 5.2743 | 12.54 | 66.15 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.93 |
| CB_MAIN_STAIRS_F1 COLLEGE - STAIRS LIGHTS | CB_MAIN_STAIRS_F1 ZN | CB_MAIN_STAIRS_F1 | COLLEGE - STAIRS | 5.2743 | 18.58 | 98.00 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 1.38 |
| CB_STORAGE_F1 COLLEGE - STORAGE LIGHTS | CB_STORAGE_F1 ZN | CB_STORAGE_F1 | COLLEGE - STORAGE | 4.0903 | 75.25 | 307.80 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 4.33 |
| CB_STUDIO_1_F2 COLLEGE - ART CLASSROOM LIGHTS | CB_STUDIO_1_F2 ZN | CB_STUDIO_1_F2 | COLLEGE - ART CLASSROOM | 7.6424 | 299.61 | 2289.75 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 32.22 |
| CB_STUDIO_1_F3 COLLEGE - ART CLASSROOM LIGHTS | CB_STUDIO_1_F3 ZN | CB_STUDIO_1_F3 | COLLEGE - ART CLASSROOM | 7.6424 | 299.61 | 2289.75 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 32.22 |
| CB_STUDIO_2_F2 COLLEGE - ART CLASSROOM LIGHTS | CB_STUDIO_2_F2 ZN | CB_STUDIO_2_F2 | COLLEGE - ART CLASSROOM | 7.6424 | 299.61 | 2289.75 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 32.22 |
| CB_STUDIO_2_F3 COLLEGE - ART CLASSROOM LIGHTS | CB_STUDIO_2_F3 ZN | CB_STUDIO_2_F3 | COLLEGE - ART CLASSROOM | 7.6424 | 299.61 | 2289.75 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 32.22 |
| CB_UTILITY_F1 COLLEGE - UTILITY LIGHTS | CB_UTILITY_F1 ZN | CB_UTILITY_F1 | COLLEGE - UTILITY | 4.6285 | 8.18 | 37.84 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.53 |
| CB_UTILITY_F4 COLLEGE - UTILITY LIGHTS | CB_UTILITY_F4 ZN | CB_UTILITY_F4 | COLLEGE - UTILITY | 4.6285 | 8.18 | 37.84 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.53 |
| CB_UTILITY_F3 COLLEGE - UTILITY LIGHTS | CB_UTILITY_F3 ZN | CB_UTILITY_F3 | COLLEGE - UTILITY | 4.6285 | 8.18 | 37.84 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.53 |
| CB_UTILITY_F2 COLLEGE - UTILITY LIGHTS | CB_UTILITY_F2 ZN | CB_UTILITY_F2 | COLLEGE - UTILITY | 4.6285 | 8.18 | 37.84 | General | COLLEGE BLDG_LIGHT_SCH | 75.16 | 168.00 | 74.97 | 0.0000 | Y | 0.53 |
| Interior Lighting Total | 7.9204 | 6292.69 | 49840.41 | 701.37 |
| Zone | Control Name | Daylighting Method | Control Type | Fraction Controlled | Lighting Installed in Zone [W] | Lighting Controlled [W] | |
| CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 1 | CB_CAFE_STUDY_LOUNGE_F1 ZN | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.33 | 1141.65 | 373.32 |
| CB_CAFE_STUDY_LOUNGE_F1 DAYLT SENSOR 2 | CB_CAFE_STUDY_LOUNGE_F1 ZN | CB_CAFE_STUDY_LOUNGE_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.26 | 1141.65 | 296.83 |
| CB_CLASSROOM_1_F2 DAYLT SENSOR 1 | CB_CLASSROOM_1_F2 ZN | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.55 | 431.32 | 235.93 |
| CB_CLASSROOM_1_F2 DAYLT SENSOR 2 | CB_CLASSROOM_1_F2 ZN | CB_CLASSROOM_1_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.34 | 431.32 | 144.93 |
| CB_CLASSROOM_1_F3 DAYLT SENSOR 1 | CB_CLASSROOM_1_F3 ZN | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.55 | 431.32 | 235.93 |
| CB_CLASSROOM_1_F3 DAYLT SENSOR 2 | CB_CLASSROOM_1_F3 ZN | CB_CLASSROOM_1_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.34 | 431.32 | 144.93 |
| CB_CLASSROOM_1_F4 DAYLT SENSOR 1 | CB_CLASSROOM_1_F4 ZN | CB_CLASSROOM_1_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.48 | 575.10 | 278.35 |
| CB_CLASSROOM_2_F4 DAYLT SENSOR 1 | CB_CLASSROOM_2_F4 ZN | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_2_F4 DAYLT SENSOR 2 | CB_CLASSROOM_2_F4 ZN | CB_CLASSROOM_2_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_3_F4 DAYLT SENSOR 1 | CB_CLASSROOM_3_F4 ZN | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_3_F4 DAYLT SENSOR 2 | CB_CLASSROOM_3_F4 ZN | CB_CLASSROOM_3_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_4_F4 DAYLT SENSOR 1 | CB_CLASSROOM_4_F4 ZN | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_4_F4 DAYLT SENSOR 2 | CB_CLASSROOM_4_F4 ZN | CB_CLASSROOM_4_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_5_F4 DAYLT SENSOR 1 | CB_CLASSROOM_5_F4 ZN | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_5_F4 DAYLT SENSOR 2 | CB_CLASSROOM_5_F4 ZN | CB_CLASSROOM_5_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 575.10 | 170.23 |
| CB_CLASSROOM_6_F4 DAYLT SENSOR 1 | CB_CLASSROOM_6_F4 ZN | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.48 | 575.10 | 278.35 |
| CB_CLASSROOM_6_F4 DAYLT SENSOR 2 | CB_CLASSROOM_6_F4 ZN | CB_CLASSROOM_6_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.33 | 575.10 | 187.48 |
| CB_CLASSROOM_8_F2 DAYLT SENSOR 1 | CB_CLASSROOM_8_F2 ZN | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.55 | 431.32 | 235.93 |
| CB_CLASSROOM_8_F2 DAYLT SENSOR 2 | CB_CLASSROOM_8_F2 ZN | CB_CLASSROOM_8_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.34 | 431.32 | 144.93 |
| CB_CLASSROOM_8_F3 DAYLT SENSOR 1 | CB_CLASSROOM_8_F3 ZN | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.55 | 431.32 | 235.93 |
| CB_CLASSROOM_8_F3 DAYLT SENSOR 2 | CB_CLASSROOM_8_F3 ZN | CB_CLASSROOM_8_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.34 | 431.32 | 144.93 |
| CB_LAB_1_F4 DAYLT SENSOR 1 | CB_LAB_1_F4 ZN | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.39 | 1935.15 | 750.84 |
| CB_LAB_1_F4 DAYLT SENSOR 2 | CB_LAB_1_F4 ZN | CB_LAB_1_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 1935.15 | 580.54 |
| CB_LAB_2_F4 DAYLT SENSOR 1 | CB_LAB_2_F4 ZN | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.17 | 1935.15 | 319.30 |
| CB_LAB_2_F4 DAYLT SENSOR 2 | CB_LAB_2_F4 ZN | CB_LAB_2_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.17 | 1935.15 | 319.30 |
| CB_LAB_3_F4 DAYLT SENSOR 1 | CB_LAB_3_F4 ZN | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.17 | 1935.15 | 319.30 |
| CB_LAB_3_F4 DAYLT SENSOR 2 | CB_LAB_3_F4 ZN | CB_LAB_3_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.17 | 1935.15 | 319.30 |
| CB_LAB_4_F4 DAYLT SENSOR 1 | CB_LAB_4_F4 ZN | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.39 | 1935.15 | 750.84 |
| CB_LAB_4_F4 DAYLT SENSOR 2 | CB_LAB_4_F4 ZN | CB_LAB_4_F4 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.30 | 1935.15 | 580.54 |
| CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 1 | CB_LECTURE_ROOM_1_F1 ZN | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.28 | 1775.10 | 489.93 |
| CB_LECTURE_ROOM_1_F1 DAYLT SENSOR 2 | CB_LECTURE_ROOM_1_F1 ZN | CB_LECTURE_ROOM_1_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.23 | 1775.10 | 411.82 |
| CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 1 | CB_LECTURE_ROOM_2_F1 ZN | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.39 | 1150.20 | 448.58 |
| CB_LECTURE_ROOM_2_F1 DAYLT SENSOR 2 | CB_LECTURE_ROOM_2_F1 ZN | CB_LECTURE_ROOM_2_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.31 | 1150.20 | 357.71 |
| CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 1 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.28 | 2415.30 | 666.62 |
| CB_LIBRARY_MEDIA_CENTER_F1 DAYLT SENSOR 2 | CB_LIBRARY_MEDIA_CENTER_F1 ZN | CB_LIBRARY_MEDIA_CENTER_F1 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.23 | 2415.30 | 560.35 |
| CB_STUDIO_1_F2 DAYLT SENSOR 1 | CB_STUDIO_1_F2 ZN | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.25 | 2289.75 | 570.15 |
| CB_STUDIO_1_F2 DAYLT SENSOR 2 | CB_STUDIO_1_F2 ZN | CB_STUDIO_1_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.21 | 2289.75 | 480.85 |
| CB_STUDIO_1_F3 DAYLT SENSOR 1 | CB_STUDIO_1_F3 ZN | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.25 | 2289.75 | 570.15 |
| CB_STUDIO_1_F3 DAYLT SENSOR 2 | CB_STUDIO_1_F3 ZN | CB_STUDIO_1_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.21 | 2289.75 | 480.85 |
| CB_STUDIO_2_F2 DAYLT SENSOR 1 | CB_STUDIO_2_F2 ZN | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.25 | 2289.75 | 570.15 |
| CB_STUDIO_2_F2 DAYLT SENSOR 2 | CB_STUDIO_2_F2 ZN | CB_STUDIO_2_F2 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.21 | 2289.75 | 480.85 |
| CB_STUDIO_2_F3 DAYLT SENSOR 1 | CB_STUDIO_2_F3 ZN | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.25 | 2289.75 | 570.15 |
| CB_STUDIO_2_F3 DAYLT SENSOR 2 | CB_STUDIO_2_F3 ZN | CB_STUDIO_2_F3 ZN DAYLIGHTINGCONTROLS | SplitFlux | Continuous | 0.21 | 2289.75 | 480.85 |
| Total Watts | Astronomical Clock/Schedule | Schedule Name | Scheduled Hours/Week [hr] | Hours/Week > 1% [hr] | Full Load Hours/Week [hr] | Consumption [GJ] | |
| NONDIMMING EXTERIOR LIGHTS DEF | 441.80 | AstronomicalClock | - | 41.87 | 41.87 | 3.47 | |
| OCC SENSING EXTERIOR LIGHTS DEF | 8552.00 | AstronomicalClock | - | 41.87 | 41.87 | 67.22 | |
| Exterior Lighting Total | 8993.80 | 70.69 |
Report: Equipment Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Central Plant| Type | Reference Capacity [W] | Reference Efficiency [W/W] | Rated Capacity [W] | Rated Efficiency [W/W] | IPLV in SI Units [W/W] | IPLV in IP Units [Btu/W-h] | |
| 90.1-2019 WATERCOOLED CENTRIFUGAL CHILLER 0 116TONS 0.6KW/TON | Chiller:Electric:EIR | 427126.69 | 5.77 | 460574.28 | 6.29 | 6.51 | 22.34 |
| CENTRIFUGAL VARIABLE SPEED FAN OPEN COOLING TOWER 20.0 GPM/HP | CoolingTower:VariableSpeed | 572990.39 | |||||
| BOILER 551KBTU/HR 0.8 THERMAL EFF | Boiler:HotWater | 92925.44 | 0.80 |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Sensible Capacity [W] | Nominal Latent Capacity [W] | Nominal Sensible Heat Ratio | Nominal Efficiency [W/W] | Nominal Coil UA Value [W/C] | Nominal Coil Surface Area [m2] | |
| VAV_1 CLG COIL | Coil:Cooling:Water | 110731.60 | 135114.39 | 94979.12 | 40135.27 | 0.70 | - | 14097.27 | 142.98 |
| VAV_2 CLG COIL | Coil:Cooling:Water | 94101.46 | 115284.02 | 81080.24 | 34203.78 | 0.70 | - | 12055.28 | 122.27 |
| VAV_3 CLG COIL | Coil:Cooling:Water | 93505.25 | 114382.59 | 80409.87 | 33972.72 | 0.70 | - | 11961.27 | 121.32 |
| VAV_4 CLG COIL | Coil:Cooling:Water | 128788.38 | 163314.48 | 116149.84 | 47164.64 | 0.71 | - | 17072.45 | 173.16 |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP [W/W] | EER [Btu/W-h] | SEER User [Btu/W-h] | SEER Standard [Btu/W-h] | IEER [Btu/W-h] | |
| None |
| DX Cooling Coil Type | Standard Rated Net Cooling Capacity [W] | Standard Rated Net COP2 [W/W] | EER2 [Btu/W-h] | SEER2 User [Btu/W-h] | SEER2 Standard [Btu/W-h] | IEER2 [Btu/W-h] | |
| None |
| DX Cooling Coil Type | Rated Net Cooling Capacity Test A [W] | Rated Electric Power Test A [W] | Rated Net Cooling Capacity Test B [W] | Rated Electric Power Test B [W] | Rated Net Cooling Capacity Test C [W] | Rated Electric Power Test C [W] | Rated Net Cooling Capacity Test D [W] | Rated Electric Power Test D [W] | |
| None |
| Coil Type | Rated Total Capacity [W] | Rated Sensible Capacity [W] | Rated Power[W] | Rated COP [W/W] | Rated Air Dry-bulb Temperature [C] | Rated Air Wet-bulb Temperature [C] | Rated Water Temperature [C] | Design Day used for Sizing | |
| None |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF [Btu/W-h] | Region Number | |
| None |
| DX Heating Coil Type | High Temperature Heating (net) Rating Capacity [W] | Low Temperature Heating (net) Rating Capacity [W] | HSPF2 [Btu/W-h] | Region Number | |
| None |
| Type | Design Coil Load [W] | Nominal Total Capacity [W] | Nominal Efficiency [W/W] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | Coil:Heating:Water | 47.98 | 45.38 | - |
| CB_CLASSROOM_1_F2 ZN REHEAT COIL | Coil:Heating:Water | 2322.42 | 2195.70 | - |
| CB_CLASSROOM_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 2469.41 | 2334.67 | - |
| CB_CLASSROOM_1_F4 ZN REHEAT COIL | Coil:Heating:Water | 3495.13 | 3304.41 | - |
| CB_CLASSROOM_2_F2 ZN REHEAT COIL | Coil:Heating:Water | 962.56 | 910.04 | - |
| CB_CLASSROOM_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 1040.99 | 984.20 | - |
| CB_CLASSROOM_2_F4 ZN REHEAT COIL | Coil:Heating:Water | 1909.95 | 1805.74 | - |
| CB_CLASSROOM_3_F2 ZN REHEAT COIL | Coil:Heating:Water | 848.00 | 801.73 | - |
| CB_CLASSROOM_3_F3 ZN REHEAT COIL | Coil:Heating:Water | 899.29 | 850.23 | - |
| CB_CLASSROOM_3_F4 ZN REHEAT COIL | Coil:Heating:Water | 1815.09 | 1716.05 | - |
| CB_CLASSROOM_4_F2 ZN REHEAT COIL | Coil:Heating:Water | 862.85 | 815.78 | - |
| CB_CLASSROOM_4_F3 ZN REHEAT COIL | Coil:Heating:Water | 938.95 | 887.72 | - |
| CB_CLASSROOM_4_F4 ZN REHEAT COIL | Coil:Heating:Water | 1947.87 | 1841.59 | - |
| CB_CLASSROOM_5_F2 ZN REHEAT COIL | Coil:Heating:Water | 694.83 | 656.92 | - |
| CB_CLASSROOM_5_F3 ZN REHEAT COIL | Coil:Heating:Water | 827.20 | 782.07 | - |
| CB_CLASSROOM_5_F4 ZN REHEAT COIL | Coil:Heating:Water | 1931.03 | 1825.67 | - |
| CB_CLASSROOM_6_F2 ZN REHEAT COIL | Coil:Heating:Water | 383.01 | 362.12 | - |
| CB_CLASSROOM_6_F3 ZN REHEAT COIL | Coil:Heating:Water | 834.33 | 788.81 | - |
| CB_CLASSROOM_6_F4 ZN REHEAT COIL | Coil:Heating:Water | 3540.88 | 3347.67 | - |
| CB_CLASSROOM_7_F2 ZN REHEAT COIL | Coil:Heating:Water | 299.08 | 282.76 | - |
| CB_CLASSROOM_7_F3 ZN REHEAT COIL | Coil:Heating:Water | 960.83 | 908.41 | - |
| CB_CLASSROOM_8_F2 ZN REHEAT COIL | Coil:Heating:Water | 1590.30 | 1503.54 | - |
| CB_CLASSROOM_8_F3 ZN REHEAT COIL | Coil:Heating:Water | 2365.08 | 2236.03 | - |
| CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_CORRIDOR_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 562.90 | 532.19 | - |
| CB_CORRIDOR_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 30.34 | 28.70 | - |
| CB_CORRIDOR_F1 ZN REHEAT COIL | Coil:Heating:Water | 192.65 | 182.12 | - |
| CB_CORRIDOR_F2 ZN REHEAT COIL | Coil:Heating:Water | 188.54 | 178.43 | - |
| CB_CORRIDOR_F4 ZN REHEAT COIL | Coil:Heating:Water | 1593.57 | 1506.64 | - |
| CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | Coil:Heating:Water | 932.28 | 881.42 | - |
| CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | Coil:Heating:Water | 386.25 | 365.17 | - |
| CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 415.26 | 392.60 | - |
| CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | Coil:Heating:Water | 477.47 | 451.42 | - |
| CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | Coil:Heating:Water | 398.94 | 377.17 | - |
| CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 438.87 | 414.93 | - |
| CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | Coil:Heating:Water | 588.71 | 556.59 | - |
| CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | Coil:Heating:Water | 399.66 | 377.86 | - |
| CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | Coil:Heating:Water | 441.71 | 417.61 | - |
| CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | Coil:Heating:Water | 601.25 | 568.45 | - |
| CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | Coil:Heating:Water | 399.26 | 377.48 | - |
| CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | Coil:Heating:Water | 442.17 | 418.05 | - |
| CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | Coil:Heating:Water | 602.67 | 569.78 | - |
| CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | Coil:Heating:Water | 399.16 | 377.38 | - |
| CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | Coil:Heating:Water | 442.30 | 418.17 | - |
| CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | Coil:Heating:Water | 602.75 | 569.86 | - |
| CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | Coil:Heating:Water | 399.74 | 377.93 | - |
| CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | Coil:Heating:Water | 441.84 | 417.73 | - |
| CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | Coil:Heating:Water | 601.31 | 568.50 | - |
| CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | Coil:Heating:Water | 397.42 | 375.73 | - |
| CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | Coil:Heating:Water | 438.51 | 414.59 | - |
| CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | Coil:Heating:Water | 588.61 | 556.50 | - |
| CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | Coil:Heating:Water | 380.43 | 359.68 | - |
| CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | Coil:Heating:Water | 413.40 | 390.85 | - |
| CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | Coil:Heating:Water | 476.10 | 450.12 | - |
| CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_LAB_1_F4 ZN REHEAT COIL | Coil:Heating:Water | 584.08 | 552.22 | - |
| CB_LAB_2_F4 ZN REHEAT COIL | Coil:Heating:Water | 26.39 | 24.96 | - |
| CB_LAB_3_F4 ZN REHEAT COIL | Coil:Heating:Water | 26.39 | 24.96 | - |
| CB_LAB_4_F4 ZN REHEAT COIL | Coil:Heating:Water | 662.66 | 626.52 | - |
| CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | Coil:Heating:Water | 3128.02 | 2957.37 | - |
| CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | Coil:Heating:Water | 3281.34 | 3102.31 | - |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | Coil:Heating:Water | 2445.03 | 2312.88 | - |
| CB_MAIN_STAIRS_F1 ZN REHEAT COIL | Coil:Heating:Water | 411.42 | 388.98 | - |
| CB_MAIN_STAIRS_F2 ZN REHEAT COIL | Coil:Heating:Water | 470.70 | 445.02 | - |
| CB_MAIN_STAIRS_F3 ZN REHEAT COIL | Coil:Heating:Water | 562.85 | 532.14 | - |
| CB_MAIN_STAIRS_F4 ZN REHEAT COIL | Coil:Heating:Water | 701.80 | 663.51 | - |
| CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | Coil:Heating:Water | 329.84 | 311.84 | - |
| CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | Coil:Heating:Water | 337.72 | 319.30 | - |
| CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | Coil:Heating:Water | 338.52 | 320.05 | - |
| CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | Coil:Heating:Water | 338.62 | 320.15 | - |
| CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | Coil:Heating:Water | 338.53 | 320.06 | - |
| CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | Coil:Heating:Water | 338.28 | 319.82 | - |
| CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | Coil:Heating:Water | 336.69 | 318.33 | - |
| CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | Coil:Heating:Water | 321.39 | 303.86 | - |
| CB_OFFICES_OPEN_F1 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_OFFICES_OPEN_F2 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_OFFICES_OPEN_F3 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_OFFICES_OPEN_F4 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | Coil:Heating:Water | 27.78 | 26.29 | - |
| CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | Coil:Heating:Water | 384.20 | 363.24 | - |
| CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 452.53 | 427.84 | - |
| CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | Coil:Heating:Water | 551.13 | 521.06 | - |
| CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | Coil:Heating:Water | 381.94 | 361.11 | - |
| CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | Coil:Heating:Water | 454.98 | 430.15 | - |
| CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 470.80 | 445.12 | - |
| CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | Coil:Heating:Water | 562.94 | 532.23 | - |
| CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STORAGE_F1 ZN REHEAT COIL | Coil:Heating:Water | 597.53 | 564.94 | - |
| CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 0.00 | 0.00 | - |
| CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | Coil:Heating:Water | 1.12 | 6.69 | - |
| CB_STUDIO_1_F2 ZN REHEAT COIL | Coil:Heating:Water | 2768.57 | 2617.54 | - |
| CB_STUDIO_1_F3 ZN REHEAT COIL | Coil:Heating:Water | 3091.09 | 2922.46 | - |
| CB_STUDIO_2_F2 ZN REHEAT COIL | Coil:Heating:Water | 3364.83 | 3181.27 | - |
| CB_STUDIO_2_F3 ZN REHEAT COIL | Coil:Heating:Water | 2887.02 | 2729.52 | - |
| CB_UTILITY_F1 ZN REHEAT COIL | Coil:Heating:Water | 30.85 | 29.18 | - |
| CB_UTILITY_F2 ZN REHEAT COIL | Coil:Heating:Water | 45.62 | 43.13 | - |
| CB_UTILITY_F3 ZN REHEAT COIL | Coil:Heating:Water | 71.34 | 67.45 | - |
| CB_UTILITY_F4 ZN REHEAT COIL | Coil:Heating:Water | 146.95 | 138.93 | - |
| VAV_1 MAIN HTG COIL | Coil:Heating:Water | 1836.26 | 1714.72 | - |
| VAV_2 MAIN HTG COIL | Coil:Heating:Water | 4167.51 | 3810.34 | - |
| VAV_3 MAIN HTG COIL | Coil:Heating:Water | 4357.77 | 3976.92 | - |
| VAV_4 MAIN HTG COIL | Coil:Heating:Water | 3631.30 | 3365.78 | - |
| Type | Total Efficiency [W/W] | Delta Pressure [pa] | Max Air Flow Rate [m3/s] | Rated Electricity Rate [W] | Rated Power Per Max Air Flow Rate [W-s/m3] | Motor Heat In Air Fraction | Fan Energy Index | End Use Subcategory | Design Day Name for Fan Sizing Peak | Date/Time for Fan Sizing Peak | |
| VAV_1 FAN | Fan:VariableVolume | 0.60 | 1389.92 | 5.61 | 12907.22 | 2299.28 | 1.00 | 1.13 | VAV System Fans | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 |
| VAV_2 FAN | Fan:VariableVolume | 0.60 | 1389.92 | 4.79 | 11095.10 | 2314.21 | 1.00 | 1.13 | VAV System Fans | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 |
| VAV_3 FAN | Fan:VariableVolume | 0.60 | 1389.92 | 4.75 | 10993.22 | 2314.21 | 1.00 | 1.13 | VAV System Fans | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 |
| VAV_4 FAN | Fan:VariableVolume | 0.61 | 1389.92 | 7.02 | 16047.62 | 2284.54 | 1.00 | 1.13 | VAV System Fans | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 |
| Type | Control | Head [pa] | Water Flow [m3/s] | Electricity Rate [W] | Power Per Water Flow Rate [W-s/m3] | Motor Efficiency [W/W] | End Use Subcategory | |
| CHILLED WATER LOOP SECONDARY PUMP | Pump:VariableSpeed | Intermittent | 134508.01 | 0.018135 | 3456.18 | 190580.89 | 0.90 | General |
| CHILLED WATER LOOP PRIMARY PUMP | Pump:ConstantSpeed | Intermittent | 44836.00 | 0.018135 | 1192.02 | 65730.21 | 0.87 | General |
| CONDENSER WATER LOOP CONSTANT PUMP | Pump:ConstantSpeed | Intermittent | 148556.63 | 0.024823 | 5099.58 | 205436.18 | 0.93 | General |
| HOT WATER LOOP PUMP | Pump:VariableSpeed | Intermittent | 179344.02 | 0.002033 | 534.40 | 262920.85 | 0.87 | General |
| MAIN SERVICE WATER LOOP CIRCULATOR PUMP | Pump:ConstantSpeed | Intermittent | 29891.00 | 0.000037 | 2.00 | 54745.42 | 0.70 | General |
| Type | Storage Volume [m3] | Input [W] | Thermal Efficiency [W/W] | Recovery Efficiency [W/W] | Energy Factor | |
| 300GAL NATURAL GAS WATER HEATER - 300KBTU/HR 0.804 THERM EFF | WaterHeater:Mixed | 1.14 | 87921.32 | 0.80 | 0.48 | 0.06 |
Report: HVAC Sizing Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Zone Sensible Cooling| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 16697.11 | 19201.68 | 106.81 | 1.225 | 1.409 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 23.89 | 23.88 | 0.00913 | 33.90 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 3324.27 | 3822.91 | 67.74 | 0.244 | 0.281 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:00:00 | 23.89 | 23.88 | 0.00967 | 30.90 | 0.01653 | 0.000 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 3325.92 | 3824.81 | 67.77 | 0.244 | 0.281 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:10:00 | 23.89 | 23.88 | 0.00966 | 31.10 | 0.01653 | 0.000 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 5063.46 | 5822.98 | 77.38 | 0.372 | 0.427 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.00953 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 2500.40 | 2875.46 | 50.95 | 0.184 | 0.211 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01001 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 2499.42 | 2874.34 | 50.93 | 0.183 | 0.211 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01002 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 3717.28 | 4274.87 | 56.81 | 0.273 | 0.314 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.88 | 0.00986 | 33.58 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 2495.02 | 2869.27 | 50.84 | 0.183 | 0.211 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01001 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 2439.31 | 2805.21 | 49.70 | 0.179 | 0.206 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01005 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 3619.42 | 4162.33 | 55.31 | 0.266 | 0.305 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.88 | 0.00990 | 33.66 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 2784.82 | 3202.54 | 56.74 | 0.204 | 0.235 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.00985 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 2459.25 | 2828.14 | 50.11 | 0.180 | 0.208 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01004 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 3697.60 | 4252.24 | 56.51 | 0.271 | 0.312 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.88 | 0.00987 | 33.66 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 2339.83 | 2690.81 | 47.68 | 0.172 | 0.197 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01011 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 2349.40 | 2701.80 | 47.87 | 0.172 | 0.198 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01011 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 3712.56 | 4269.44 | 56.74 | 0.272 | 0.313 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.88 | 0.00986 | 33.66 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 2512.94 | 2889.88 | 51.20 | 0.184 | 0.212 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01000 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 2433.78 | 2798.85 | 49.59 | 0.179 | 0.205 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01006 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 4512.65 | 5189.55 | 68.96 | 0.331 | 0.381 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 13:00:00 | 23.89 | 23.88 | 0.00965 | 33.50 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 2637.10 | 3032.66 | 53.73 | 0.194 | 0.223 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.00993 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 2516.31 | 2893.76 | 51.27 | 0.185 | 0.212 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01001 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 3772.18 | 4338.00 | 76.86 | 0.277 | 0.318 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.00953 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 3660.19 | 4209.22 | 74.58 | 0.269 | 0.309 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.00957 | 33.43 | 0.01654 | 0.000 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 2329.15 | 2678.52 | 58.25 | 0.171 | 0.197 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01074 | 33.43 | 0.01654 | 0.082 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 1570.02 | 1805.53 | 58.89 | 0.115 | 0.133 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01072 | 33.43 | 0.01654 | 0.055 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 1567.12 | 1802.18 | 58.78 | 0.115 | 0.132 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.88 | 0.01072 | 33.43 | 0.01654 | 0.055 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 1791.42 | 2060.13 | 67.20 | 0.132 | 0.151 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.88 | 0.01044 | 33.66 | 0.01654 | 0.055 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 1538.61 | 1769.41 | 23.51 | 0.113 | 0.130 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 23.89 | 23.89 | 0.00967 | 33.50 | 0.01654 | 0.000 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 595.15 | 684.42 | 55.81 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 599.93 | 689.92 | 56.26 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 716.37 | 823.83 | 67.18 | 0.053 | 0.060 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00879 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 596.69 | 686.19 | 55.96 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 600.13 | 690.14 | 56.28 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 699.05 | 803.91 | 65.55 | 0.051 | 0.059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00880 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 596.11 | 685.52 | 55.90 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 599.73 | 689.69 | 56.24 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 697.51 | 802.14 | 65.41 | 0.051 | 0.059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00880 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 595.69 | 685.05 | 55.86 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 599.74 | 689.70 | 56.24 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 697.39 | 802.00 | 65.40 | 0.051 | 0.059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00880 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 595.62 | 684.97 | 55.86 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 599.83 | 689.80 | 56.25 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 697.45 | 802.06 | 65.40 | 0.051 | 0.059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00880 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 596.20 | 685.64 | 55.91 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 599.83 | 689.80 | 56.25 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 697.57 | 802.21 | 65.42 | 0.051 | 0.059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00880 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 596.00 | 685.40 | 55.89 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00883 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 600.02 | 690.02 | 56.27 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00884 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 699.16 | 804.03 | 65.56 | 0.051 | 0.059 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00880 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 595.18 | 684.45 | 55.81 | 0.044 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 23.89 | 23.89 | 0.00883 | 33.50 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 600.87 | 691.00 | 56.35 | 0.044 | 0.051 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 23.89 | 23.89 | 0.00884 | 33.50 | 0.01654 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 717.10 | 824.67 | 67.25 | 0.053 | 0.061 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00879 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_LAB_1_F4 ZN | 11873.97 | 13655.07 | 101.02 | 0.871 | 1.002 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00865 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_LAB_2_F4 ZN | 9186.04 | 10563.94 | 78.15 | 0.674 | 0.775 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 23.89 | 23.89 | 0.00874 | 33.90 | 0.01654 | 0.000 | 0.00 |
| CB_LAB_3_F4 ZN | 9186.51 | 10564.49 | 78.15 | 0.674 | 0.775 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 23.89 | 23.89 | 0.00874 | 33.90 | 0.01654 | 0.000 | 0.00 |
| CB_LAB_4_F4 ZN | 11135.14 | 12805.41 | 94.73 | 0.817 | 0.940 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:30:00 | 23.89 | 23.89 | 0.00872 | 32.48 | 0.01653 | 0.000 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 11687.71 | 13440.87 | 49.72 | 0.858 | 0.986 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:40:00 | 23.89 | 23.88 | 0.00996 | 32.61 | 0.01653 | 0.000 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 6973.21 | 8019.19 | 53.28 | 0.512 | 0.589 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.88 | 0.00994 | 33.66 | 0.01654 | 0.000 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 9378.83 | 10785.66 | 39.90 | 0.688 | 0.791 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00873 | 32.79 | 0.01653 | 0.069 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 581.62 | 668.87 | 54.54 | 0.043 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 579.19 | 666.06 | 54.31 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 578.78 | 665.60 | 54.28 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 578.75 | 665.56 | 54.27 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 578.69 | 665.50 | 54.27 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 578.66 | 665.46 | 54.26 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 578.73 | 665.54 | 54.27 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00881 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 577.68 | 664.34 | 54.17 | 0.042 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 23.89 | 23.89 | 0.00881 | 33.50 | 0.01654 | 0.002 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 4162.12 | 4786.44 | 24.65 | 0.305 | 0.351 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:50:00 | 23.89 | 23.89 | 0.00906 | 32.90 | 0.01653 | 0.025 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 4508.28 | 5184.52 | 24.75 | 0.331 | 0.380 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00906 | 32.79 | 0.01653 | 0.027 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 4548.64 | 5230.94 | 24.97 | 0.334 | 0.384 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00905 | 32.79 | 0.01653 | 0.027 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 5747.33 | 6609.43 | 31.55 | 0.422 | 0.485 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00894 | 33.74 | 0.01654 | 0.027 | 0.00 |
| CB_STUDIO_1_F2 ZN | 10844.78 | 12471.50 | 41.63 | 0.796 | 0.915 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00903 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDIO_1_F3 ZN | 9816.68 | 11289.18 | 37.68 | 0.720 | 0.828 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00910 | 33.58 | 0.01654 | 0.000 | 0.00 |
| CB_STUDIO_2_F2 ZN | 9555.92 | 10989.31 | 36.68 | 0.701 | 0.806 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.89 | 0.00910 | 33.66 | 0.01654 | 0.000 | 0.00 |
| CB_STUDIO_2_F3 ZN | 11057.87 | 12716.55 | 42.44 | 0.811 | 0.933 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00903 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 561.84 | 646.12 | 20.46 | 0.041 | 0.047 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:50:00 | 23.89 | 23.89 | 0.00860 | 33.50 | 0.01654 | 0.003 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 782.44 | 899.80 | 14.67 | 0.057 | 0.066 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.89 | 0.00850 | 33.43 | 0.01654 | 0.006 | 0.00 |
| CB_CORRIDOR_F1 ZN | 4153.68 | 4776.73 | 39.10 | 0.305 | 0.350 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.89 | 0.00851 | 33.43 | 0.01654 | 0.012 | 0.00 |
| CB_CORRIDOR_F2 ZN | 1607.41 | 1848.52 | 19.90 | 0.118 | 0.136 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.89 | 0.00853 | 33.43 | 0.01654 | 0.009 | 0.00 |
| CB_CORRIDOR_F4 ZN | 3269.65 | 3760.10 | 24.83 | 0.240 | 0.276 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:30:00 | 23.89 | 23.89 | 0.00852 | 33.66 | 0.01654 | 0.015 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 127.76 | 146.93 | 14.75 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 122.93 | 141.37 | 14.19 | 0.009 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 185.19 | 212.97 | 21.37 | 0.014 | 0.016 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 23.89 | 23.89 | 0.00850 | 33.90 | 0.01654 | 0.000 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 126.72 | 145.73 | 14.63 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 127.93 | 147.12 | 14.77 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 180.62 | 207.71 | 20.85 | 0.013 | 0.015 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 23.89 | 23.89 | 0.00850 | 33.90 | 0.01654 | 0.000 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 363.60 | 418.14 | 22.50 | 0.027 | 0.031 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00859 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 338.87 | 389.70 | 20.97 | 0.025 | 0.029 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00864 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 339.19 | 390.07 | 20.99 | 0.025 | 0.029 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00866 | 33.58 | 0.01654 | 0.002 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 453.21 | 521.19 | 28.05 | 0.033 | 0.038 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00863 | 33.74 | 0.01654 | 0.002 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 615.50 | 707.83 | 56.44 | 0.045 | 0.052 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 23.89 | 23.89 | 0.00854 | 32.66 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 586.38 | 674.34 | 53.77 | 0.043 | 0.049 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:20:00 | 23.89 | 23.89 | 0.00856 | 32.53 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 590.57 | 679.16 | 54.15 | 0.043 | 0.050 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:20:00 | 23.89 | 23.89 | 0.00857 | 32.53 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 722.54 | 830.92 | 66.25 | 0.053 | 0.061 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:10:00 | 23.89 | 23.89 | 0.00856 | 32.66 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 482.30 | 554.64 | 44.22 | 0.035 | 0.041 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:50:00 | 23.89 | 23.89 | 0.00855 | 31.89 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 518.92 | 596.76 | 47.58 | 0.038 | 0.044 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:50:00 | 23.89 | 23.89 | 0.00857 | 31.89 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 524.16 | 602.79 | 48.06 | 0.038 | 0.044 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 10:50:00 | 23.89 | 23.89 | 0.00858 | 31.89 | 0.01653 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 650.46 | 748.03 | 59.64 | 0.048 | 0.055 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 11:00:00 | 23.89 | 23.89 | 0.00857 | 32.08 | 0.01653 | 0.001 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 127.61 | 146.75 | 14.73 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 142.48 | 163.85 | 16.44 | 0.010 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STORAGE_F1 ZN | 4076.96 | 4688.51 | 62.30 | 0.299 | 0.344 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 23.89 | 23.89 | 0.00852 | 33.58 | 0.01654 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 243.87 | 280.45 | 14.64 | 0.018 | 0.021 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 228.34 | 262.59 | 13.70 | 0.017 | 0.019 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 224.82 | 258.54 | 13.49 | 0.016 | 0.019 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 326.49 | 375.47 | 19.60 | 0.024 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 23.89 | 23.89 | 0.00850 | 33.90 | 0.01654 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 278.21 | 319.94 | 16.70 | 0.020 | 0.023 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 260.25 | 299.29 | 15.62 | 0.019 | 0.022 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 259.43 | 298.35 | 15.57 | 0.019 | 0.022 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 17:00:00 | 23.89 | 23.89 | 0.00850 | 32.79 | 0.01653 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 389.00 | 447.35 | 23.35 | 0.029 | 0.033 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | 23.89 | 23.89 | 0.00850 | 33.82 | 0.01654 | 0.000 | 0.00 |
| CB_UTILITY_F1 ZN | 1259.06 | 1447.91 | 177.10 | 0.092 | 0.106 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:30:00 | 23.89 | 23.89 | 0.00850 | 33.11 | 0.01653 | 0.001 | 0.00 |
| CB_UTILITY_F2 ZN | 284.08 | 326.69 | 39.96 | 0.021 | 0.024 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.89 | 0.00850 | 33.43 | 0.01654 | 0.001 | 0.00 |
| CB_UTILITY_F3 ZN | 148.98 | 171.33 | 20.96 | 0.011 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 23.89 | 23.89 | 0.00850 | 33.43 | 0.01654 | 0.001 | 0.00 |
| CB_UTILITY_F4 ZN | 193.46 | 222.48 | 27.21 | 0.014 | 0.016 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:20:00 | 23.89 | 23.89 | 0.00850 | 33.74 | 0.01654 | 0.001 | 0.00 |
| Calculated Design Load [W] | User Design Load [W] | User Design Load per Area [W/m2] | Calculated Design Air Flow [m3/s] | User Design Air Flow [m3/s] | Design Day Name | Date/Time Of Peak {TIMESTAMP} | Thermostat Setpoint Temperature at Peak Load [C] | Indoor Temperature at Peak Load [C] | Indoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Outdoor Temperature at Peak Load [C] | Outdoor Humidity Ratio at Peak Load [kgWater/kgDryAir] | Minimum Outdoor Air Flow Rate [m3/s] | Heat Gain Rate from DOAS [W] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_CLASSROOM_1_F2 ZN | 1303.93 | 1629.92 | 28.88 | 0.054 | 0.068 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 1387.07 | 1733.83 | 30.72 | 0.058 | 0.072 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00750 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 1966.37 | 2457.96 | 32.66 | 0.081 | 0.102 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00753 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 538.22 | 672.78 | 11.92 | 0.023 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00753 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 582.24 | 727.80 | 12.90 | 0.025 | 0.031 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00749 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 1070.70 | 1338.37 | 17.79 | 0.045 | 0.056 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00755 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 473.83 | 592.28 | 10.49 | 0.020 | 0.025 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00749 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 502.64 | 628.30 | 11.13 | 0.021 | 0.027 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00744 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 1017.16 | 1271.45 | 16.90 | 0.043 | 0.053 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00753 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 482.08 | 602.60 | 10.68 | 0.020 | 0.026 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00750 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 524.80 | 656.00 | 11.62 | 0.022 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00746 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 1091.81 | 1364.76 | 18.14 | 0.046 | 0.057 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00756 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 387.93 | 484.91 | 8.59 | 0.016 | 0.021 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 462.18 | 577.72 | 10.24 | 0.020 | 0.024 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00740 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 1082.60 | 1353.25 | 17.98 | 0.045 | 0.057 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00755 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 213.32 | 266.65 | 4.72 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00712 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 466.17 | 582.72 | 10.32 | 0.020 | 0.025 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 1992.34 | 2490.43 | 33.09 | 0.082 | 0.103 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00753 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 166.49 | 208.11 | 3.69 | 0.007 | 0.009 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00694 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 537.19 | 671.48 | 11.90 | 0.023 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00746 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 889.99 | 1112.48 | 19.71 | 0.037 | 0.047 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00739 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 1327.98 | 1659.97 | 29.41 | 0.055 | 0.069 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00748 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.082 | 00:10:00 | 15.56 | 23.89 | 0.00859 | 27.34 | 0.01652 | 0.082 | 0.00 | |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.055 | 00:10:00 | 15.56 | 23.89 | 0.00861 | 27.34 | 0.01652 | 0.055 | 0.00 | |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.055 | 00:10:00 | 15.56 | 23.89 | 0.00861 | 27.34 | 0.01652 | 0.055 | 0.00 | |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.055 | 00:10:00 | 15.56 | 23.89 | 0.00860 | 27.34 | 0.01652 | 0.055 | 0.00 | |
| CB_ENTRANCE_LOBBY_F1 ZN | 520.39 | 650.49 | 8.64 | 0.022 | 0.028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00755 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 215.98 | 269.98 | 22.02 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00743 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 232.29 | 290.36 | 23.68 | 0.010 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00739 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 267.34 | 334.18 | 27.25 | 0.011 | 0.014 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00739 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 223.13 | 278.92 | 22.74 | 0.009 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00745 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 245.59 | 306.98 | 25.03 | 0.010 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 330.18 | 412.73 | 33.66 | 0.014 | 0.017 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00748 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 223.55 | 279.43 | 22.79 | 0.009 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00745 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 247.19 | 308.99 | 25.20 | 0.010 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 337.30 | 421.62 | 34.38 | 0.014 | 0.018 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00749 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 223.32 | 279.15 | 22.76 | 0.009 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00745 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 247.45 | 309.31 | 25.22 | 0.010 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 338.10 | 422.62 | 34.46 | 0.014 | 0.018 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00749 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 223.26 | 279.08 | 22.76 | 0.009 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00745 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 247.52 | 309.40 | 25.23 | 0.010 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 338.14 | 422.68 | 34.47 | 0.014 | 0.018 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00749 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 223.59 | 279.48 | 22.79 | 0.009 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00745 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 247.26 | 309.07 | 25.20 | 0.010 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 337.33 | 421.66 | 34.38 | 0.014 | 0.018 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00749 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 222.28 | 277.85 | 22.66 | 0.009 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00744 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 245.38 | 306.73 | 25.01 | 0.010 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 330.12 | 412.66 | 33.65 | 0.014 | 0.017 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00748 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 212.71 | 265.88 | 21.68 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00743 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 231.25 | 289.06 | 23.57 | 0.010 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00738 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 266.57 | 333.21 | 27.17 | 0.011 | 0.014 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00739 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_LAB_1_F4 ZN | 325.09 | 406.36 | 3.01 | 0.014 | 0.017 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00630 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_LAB_2_F4 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_LAB_3_F4 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_LAB_4_F4 ZN | 368.89 | 461.11 | 3.41 | 0.016 | 0.020 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00638 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 1746.55 | 2183.19 | 8.08 | 0.074 | 0.093 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 1836.77 | 2295.97 | 15.26 | 0.077 | 0.097 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00761 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 1071.29 | 1339.11 | 4.95 | 0.046 | 0.069 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00734 | 4.60 | 0.00526 | 0.069 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 184.22 | 230.28 | 18.78 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00753 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 188.65 | 235.82 | 19.23 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 189.10 | 236.38 | 19.28 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 189.16 | 236.45 | 19.28 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 189.11 | 236.39 | 19.28 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 188.97 | 236.21 | 19.26 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 188.08 | 235.10 | 19.17 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00754 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 179.48 | 224.35 | 18.29 | 0.008 | 0.010 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00752 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.025 | 00:10:00 | 15.56 | 23.89 | 0.00853 | 27.34 | 0.01652 | 0.025 | 0.00 | |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.027 | 00:10:00 | 15.56 | 23.89 | 0.00854 | 27.34 | 0.01652 | 0.027 | 0.00 | |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.027 | 00:10:00 | 15.56 | 23.89 | 0.00853 | 27.34 | 0.01652 | 0.027 | 0.00 | |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.027 | 00:10:00 | 15.56 | 23.89 | 0.00853 | 27.34 | 0.01652 | 0.027 | 0.00 | |
| CB_STUDIO_1_F2 ZN | 1544.81 | 1931.02 | 6.45 | 0.066 | 0.082 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00733 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_STUDIO_1_F3 ZN | 1726.57 | 2158.21 | 7.20 | 0.073 | 0.091 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00728 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_STUDIO_2_F2 ZN | 1879.24 | 2349.05 | 7.84 | 0.080 | 0.100 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00741 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_STUDIO_2_F3 ZN | 1612.16 | 2015.20 | 6.73 | 0.068 | 0.085 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00725 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 314.41 | 393.01 | 12.44 | 0.013 | 0.017 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00757 | 4.60 | 0.00526 | 0.003 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.000 | 0.006 | 00:10:00 | 15.56 | 23.89 | 0.00850 | 27.34 | 0.01652 | 0.006 | 0.00 | |
| CB_CORRIDOR_F1 ZN | 8.78 | 10.98 | 0.09 | 0.000 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 06:20:00 | 21.11 | 21.11 | 0.00526 | 4.60 | 0.00526 | 0.012 | 0.00 |
| CB_CORRIDOR_F2 ZN | 45.96 | 57.45 | 0.62 | 0.002 | 0.009 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00593 | 4.60 | 0.00526 | 0.009 | 0.00 |
| CB_CORRIDOR_F4 ZN | 888.93 | 1111.17 | 7.34 | 0.038 | 0.047 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00780 | 4.60 | 0.00526 | 0.015 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_MAIN_STAIRS_F1 ZN | 229.78 | 287.23 | 15.46 | 0.010 | 0.012 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00765 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 263.13 | 328.92 | 17.70 | 0.011 | 0.014 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00756 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 315.02 | 393.78 | 21.19 | 0.013 | 0.017 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00755 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 393.42 | 491.78 | 26.47 | 0.016 | 0.021 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00758 | 4.60 | 0.00526 | 0.002 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 7.43 | 9.29 | 0.74 | 0.000 | 0.001 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00589 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 214.85 | 268.56 | 21.41 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00759 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 253.32 | 316.65 | 25.25 | 0.011 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00758 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 308.98 | 386.23 | 30.79 | 0.013 | 0.016 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00760 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 213.49 | 266.87 | 21.28 | 0.009 | 0.011 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00770 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 254.71 | 318.38 | 25.39 | 0.011 | 0.013 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00764 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 263.60 | 329.51 | 26.27 | 0.011 | 0.014 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00759 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 315.67 | 394.59 | 31.46 | 0.013 | 0.016 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00761 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STORAGE_F1 ZN | 332.63 | 415.79 | 5.53 | 0.014 | 0.018 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00740 | 4.60 | 0.00526 | 0.000 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | N/A | N/A | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 |
| CB_UTILITY_F1 ZN | 14.27 | 17.83 | 2.18 | 0.001 | 0.001 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00794 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_UTILITY_F2 ZN | 25.37 | 31.71 | 3.88 | 0.001 | 0.001 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00800 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_UTILITY_F3 ZN | 39.71 | 49.64 | 6.07 | 0.002 | 0.002 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00800 | 4.60 | 0.00526 | 0.001 | 0.00 |
| CB_UTILITY_F4 ZN | 82.02 | 102.52 | 12.54 | 0.003 | 0.004 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 21.11 | 21.11 | 0.00800 | 4.60 | 0.00526 | 0.001 | 0.00 |
| Calculated cooling [m3/s] | User cooling [m3/s] | Calculated heating [m3/s] | User heating [m3/s] | Adjusted cooling [m3/s] | Adjusted heating [m3/s] | Adjusted main [m3/s] | Calculated Heating Air Flow Ratio [] | User Heating Air Flow Ratio [] | |
| VAV_1 | 5.61 | 5.61 | 0.53 | 0.53 | 5.6136 | 0.5268 | 5.6136 | 0.0938 | 0.3000 |
| VAV_2 | 4.79 | 4.79 | 0.64 | 0.64 | 4.7943 | 0.6400 | 4.7943 | 0.1335 | 0.3000 |
| VAV_3 | 4.75 | 4.75 | 0.73 | 0.73 | 4.7503 | 0.7328 | 4.7503 | 0.1543 | 0.3000 |
| VAV_4 | 7.02 | 7.02 | 0.78 | 0.78 | 7.0244 | 0.7838 | 7.0244 | 0.1116 | 0.3000 |
| Previous Design Volume Flow Rate [m3/s] | Algorithm Volume Flow Rate [m3/s] | Coincident Design Volume Flow Rate [m3/s] | Coincident Size Adjusted | Peak Sizing Period Name | Peak Day into Period {TIMESTAMP}[day] | Peak Hour Of Day {TIMESTAMP}[hr] | Peak Step Start Minute {TIMESTAMP}[min] | |
| CONDENSER WATER LOOP Sizing Pass 1 | 0.021585 | 0.021585 | 0.024823 | Yes | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB HVAC Sizing Pass 1 | 1 | 7 | 0. |
| Coil Type | HVAC Type | HVAC Name | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | 47.980 | 47.980 | 0.014092 | 0.00000105 | 0.778 | 8/21 00:10:00 | 8/21 00:10:00 | 47.98 | 47.98 | 0.014092 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 48.05 | 48.05 | ||
| CB_CLASSROOM_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_1_F2 ZN VAV TERMINAL | 2322.417 | 2322.417 | 0.067860 | 0.00005080 | 48.599 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 2322.42 | 2322.42 | 0.067860 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754139 | 48.3721 | 1629.92 | 0.00 | 2326.33 | 2326.33 |
| CB_CLASSROOM_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_1_F3 ZN VAV TERMINAL | 2469.414 | 2469.414 | 0.072088 | 0.00005401 | 51.690 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 2469.41 | 2469.41 | 0.072088 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00749720 | 48.0925 | 1733.83 | 0.00 | 2473.57 | 2473.57 |
| CB_CLASSROOM_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_1_F4 ZN VAV TERMINAL | 3495.128 | 3495.128 | 0.101638 | 0.00007645 | 73.249 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3495.13 | 3495.13 | 0.101638 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00752665 | 48.2790 | 2457.96 | 0.00 | 3501.02 | 3501.02 |
| CB_CLASSROOM_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_2_F2 ZN VAV TERMINAL | 962.556 | 962.556 | 0.028395 | 0.00002105 | 20.083 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 962.56 | 962.56 | 0.028395 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00753356 | 48.3213 | 672.78 | 0.00 | 964.17 | 964.17 |
| CB_CLASSROOM_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_2_F3 ZN VAV TERMINAL | 1040.991 | 1040.991 | 0.030692 | 0.00002277 | 21.723 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1040.99 | 1040.99 | 0.030692 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00748966 | 48.0432 | 727.80 | 0.00 | 1042.74 | 1042.74 |
| CB_CLASSROOM_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_2_F4 ZN VAV TERMINAL | 1909.954 | 1909.954 | 0.056008 | 0.00004178 | 39.924 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1909.95 | 1909.95 | 0.056008 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754832 | 48.4151 | 1338.37 | 0.00 | 1913.17 | 1913.17 |
| CB_CLASSROOM_3_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_3_F2 ZN VAV TERMINAL | 847.995 | 847.995 | 0.025059 | 0.00001855 | 17.684 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 848.00 | 848.00 | 0.025059 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00749227 | 48.0596 | 592.28 | 0.00 | 849.42 | 849.42 |
| CB_CLASSROOM_3_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_3_F3 ZN VAV TERMINAL | 899.292 | 899.292 | 0.026559 | 0.00001967 | 18.757 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 899.29 | 899.29 | 0.026559 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00743857 | 47.7193 | 628.30 | 0.00 | 900.80 | 900.80 |
| CB_CLASSROOM_3_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_3_F4 ZN VAV TERMINAL | 1815.086 | 1815.086 | 0.053270 | 0.00003970 | 37.931 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1815.09 | 1815.09 | 0.053270 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00753111 | 48.3060 | 1271.45 | 0.00 | 1818.14 | 1818.14 |
| CB_CLASSROOM_4_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_4_F2 ZN VAV TERMINAL | 862.852 | 862.852 | 0.025503 | 0.00001887 | 17.992 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 862.85 | 862.85 | 0.025503 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00749951 | 48.1054 | 602.60 | 0.00 | 864.30 | 864.30 |
| CB_CLASSROOM_4_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_4_F3 ZN VAV TERMINAL | 938.946 | 938.946 | 0.027729 | 0.00002054 | 19.584 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 938.95 | 938.95 | 0.027729 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00745573 | 47.8280 | 656.00 | 0.00 | 940.53 | 940.53 |
| CB_CLASSROOM_4_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_4_F4 ZN VAV TERMINAL | 1947.869 | 1947.869 | 0.057136 | 0.00004261 | 40.712 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1947.87 | 1947.87 | 0.057136 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00755951 | 48.4861 | 1364.76 | 0.00 | 1951.15 | 1951.15 |
| CB_CLASSROOM_5_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_5_F2 ZN VAV TERMINAL | 694.827 | 694.827 | 0.020574 | 0.00001520 | 14.481 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 694.83 | 694.83 | 0.020574 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00740689 | 47.5183 | 484.91 | 0.00 | 695.99 | 695.99 |
| CB_CLASSROOM_5_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_5_F3 ZN VAV TERMINAL | 827.197 | 827.197 | 0.024452 | 0.00001809 | 17.248 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 827.20 | 827.20 | 0.024452 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00740045 | 47.4776 | 577.72 | 0.00 | 828.59 | 828.59 |
| CB_CLASSROOM_5_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_5_F4 ZN VAV TERMINAL | 1931.033 | 1931.033 | 0.056615 | 0.00004224 | 40.366 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1931.03 | 1931.03 | 0.056615 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00755236 | 48.4407 | 1353.25 | 0.00 | 1934.28 | 1934.28 |
| CB_CLASSROOM_6_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_6_F2 ZN VAV TERMINAL | 383.009 | 383.009 | 0.011410 | 0.00000838 | 7.967 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 383.01 | 383.01 | 0.011410 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00711704 | 45.6797 | 266.65 | 0.00 | 383.65 | 383.65 |
| CB_CLASSROOM_6_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_6_F3 ZN VAV TERMINAL | 834.331 | 834.331 | 0.024661 | 0.00001825 | 17.397 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 834.33 | 834.33 | 0.024661 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00740685 | 47.5182 | 582.72 | 0.00 | 835.73 | 835.73 |
| CB_CLASSROOM_6_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_6_F4 ZN VAV TERMINAL | 3540.882 | 3540.882 | 0.102939 | 0.00007745 | 74.215 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3540.88 | 3540.88 | 0.102939 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00753172 | 48.3111 | 2490.43 | 0.00 | 3546.85 | 3546.85 |
| CB_CLASSROOM_7_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_7_F2 ZN VAV TERMINAL | 299.075 | 299.075 | 0.008923 | 0.00000654 | 6.219 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 299.08 | 299.08 | 0.008923 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00694160 | 44.5661 | 208.11 | 0.00 | 299.58 | 299.58 |
| CB_CLASSROOM_7_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_7_F3 ZN VAV TERMINAL | 960.825 | 960.825 | 0.028356 | 0.00002102 | 20.044 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 960.83 | 960.83 | 0.028356 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00745715 | 47.8371 | 671.48 | 0.00 | 962.44 | 962.44 |
| CB_CLASSROOM_8_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_8_F2 ZN VAV TERMINAL | 1590.300 | 1590.300 | 0.046835 | 0.00003478 | 33.198 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1590.30 | 1590.30 | 0.046835 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00739189 | 47.4243 | 1112.48 | 0.00 | 1592.98 | 1592.98 |
| CB_CLASSROOM_8_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_8_F3 ZN VAV TERMINAL | 2365.077 | 2365.077 | 0.069103 | 0.00005173 | 49.492 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 2365.08 | 2365.08 | 0.069103 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00747987 | 47.9826 | 1659.97 | 0.00 | 2369.06 | 2369.06 |
| CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_CORRIDOR_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_1_F3 ZN VAV TERMINAL | 562.897 | 562.897 | 0.016646 | 0.00001231 | 11.736 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 562.90 | 562.90 | 0.016646 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00757133 | 48.5606 | 393.01 | 0.00 | 563.84 | 563.84 |
| CB_CORRIDOR_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_2_F3 ZN VAV TERMINAL | 30.341 | 30.341 | 0.008911 | 0.00000066 | 0.492 | 8/21 00:10:00 | 8/21 00:10:00 | 30.34 | 30.34 | 0.008911 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 30.38 | 30.38 | ||
| CB_CORRIDOR_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_F1 ZN VAV TERMINAL | 192.648 | 192.648 | 0.017871 | 0.00000421 | 3.368 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 06:20:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 06:20:00 | 192.65 | 192.65 | 0.017871 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00526156 | 33.8665 | 10.98 | 0.00 | 192.87 | 192.87 |
| CB_CORRIDOR_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_F2 ZN VAV TERMINAL | 188.544 | 188.544 | 0.012883 | 0.00000412 | 3.417 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 188.54 | 188.54 | 0.012883 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00592739 | 38.1158 | 57.45 | 0.00 | 188.93 | 188.93 |
| CB_CORRIDOR_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_F4 ZN VAV TERMINAL | 1593.570 | 1593.570 | 0.047246 | 0.00003486 | 33.198 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1593.57 | 1593.57 | 0.047246 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00780001 | 50.0085 | 1111.17 | 0.00 | 1596.25 | 1596.25 |
| CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | 932.281 | 932.281 | 0.027611 | 0.00002039 | 19.428 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 932.28 | 932.28 | 0.027611 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00755217 | 48.4389 | 650.49 | 0.00 | 933.85 | 933.85 |
| CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | 386.246 | 386.246 | 0.011396 | 0.00000845 | 8.058 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 386.25 | 386.25 | 0.011396 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00743434 | 47.6935 | 269.98 | 0.00 | 386.90 | 386.90 |
| CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | 415.256 | 415.256 | 0.012242 | 0.00000908 | 8.666 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 415.26 | 415.26 | 0.012242 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00738560 | 47.3848 | 290.36 | 0.00 | 415.95 | 415.95 |
| CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | 477.468 | 477.468 | 0.014046 | 0.00001044 | 9.971 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 477.47 | 477.47 | 0.014046 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00738971 | 47.4111 | 334.18 | 0.00 | 478.27 | 478.27 |
| CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | 398.937 | 398.937 | 0.011763 | 0.00000873 | 8.325 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 398.94 | 398.94 | 0.011763 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00744604 | 47.7677 | 278.92 | 0.00 | 399.61 | 399.61 |
| CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | 438.870 | 438.870 | 0.012927 | 0.00000960 | 9.161 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 438.87 | 438.87 | 0.012927 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00740850 | 47.5300 | 306.98 | 0.00 | 439.61 | 439.61 |
| CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | 588.711 | 588.711 | 0.017247 | 0.00001288 | 12.309 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 588.71 | 588.71 | 0.017247 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00747669 | 47.9626 | 412.73 | 0.00 | 589.70 | 589.70 |
| CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | 399.665 | 399.665 | 0.011784 | 0.00000874 | 8.340 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 399.66 | 399.66 | 0.011784 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00744662 | 47.7713 | 279.43 | 0.00 | 400.34 | 400.34 |
| CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | 441.711 | 441.711 | 0.013009 | 0.00000966 | 9.221 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 441.71 | 441.71 | 0.013009 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00741113 | 47.5467 | 308.99 | 0.00 | 442.45 | 442.45 |
| CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | 601.253 | 601.253 | 0.017605 | 0.00001315 | 12.574 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 601.25 | 601.25 | 0.017605 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00748517 | 48.0163 | 421.62 | 0.00 | 602.27 | 602.27 |
| CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | 399.261 | 399.261 | 0.011772 | 0.00000873 | 8.332 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 399.26 | 399.26 | 0.011772 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00744618 | 47.7685 | 279.15 | 0.00 | 399.93 | 399.93 |
| CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | 442.172 | 442.172 | 0.013022 | 0.00000967 | 9.230 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 442.17 | 442.17 | 0.013022 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00741155 | 47.5494 | 309.31 | 0.00 | 442.92 | 442.92 |
| CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | 602.667 | 602.667 | 0.017645 | 0.00001318 | 12.604 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 602.67 | 602.67 | 0.017645 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00748610 | 48.0222 | 422.62 | 0.00 | 603.68 | 603.68 |
| CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | 399.157 | 399.157 | 0.011769 | 0.00000873 | 8.330 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 399.16 | 399.16 | 0.011769 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00744607 | 47.7679 | 279.08 | 0.00 | 399.83 | 399.83 |
| CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | 442.302 | 442.302 | 0.013026 | 0.00000967 | 9.233 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 442.30 | 442.30 | 0.013026 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00741168 | 47.5502 | 309.40 | 0.00 | 443.05 | 443.05 |
| CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | 602.746 | 602.746 | 0.017647 | 0.00001318 | 12.605 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 602.75 | 602.75 | 0.017647 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00748615 | 48.0226 | 422.68 | 0.00 | 603.76 | 603.76 |
| CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | 399.739 | 399.739 | 0.011786 | 0.00000874 | 8.342 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 399.74 | 399.74 | 0.011786 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00744670 | 47.7718 | 279.48 | 0.00 | 400.41 | 400.41 |
| CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | 441.836 | 441.836 | 0.013013 | 0.00000966 | 9.223 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 441.84 | 441.84 | 0.013013 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00741125 | 47.5475 | 309.07 | 0.00 | 442.58 | 442.58 |
| CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | 601.312 | 601.312 | 0.017607 | 0.00001315 | 12.575 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 601.31 | 601.31 | 0.017607 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00748521 | 48.0166 | 421.66 | 0.00 | 602.32 | 602.32 |
| CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | 397.415 | 397.415 | 0.011719 | 0.00000869 | 8.293 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 397.42 | 397.42 | 0.011719 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00744448 | 47.7578 | 277.85 | 0.00 | 398.08 | 398.08 |
| CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | 438.510 | 438.510 | 0.012917 | 0.00000959 | 9.153 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 438.51 | 438.51 | 0.012917 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00740814 | 47.5278 | 306.73 | 0.00 | 439.25 | 439.25 |
| CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | 588.612 | 588.612 | 0.017245 | 0.00001287 | 12.307 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 588.61 | 588.61 | 0.017245 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00747661 | 47.9621 | 412.66 | 0.00 | 589.60 | 589.60 |
| CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | 380.431 | 380.431 | 0.011227 | 0.00000832 | 7.937 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 380.43 | 380.43 | 0.011227 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00742810 | 47.6540 | 265.88 | 0.00 | 381.07 | 381.07 |
| CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | 413.405 | 413.405 | 0.012189 | 0.00000904 | 8.627 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 413.40 | 413.40 | 0.012189 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00738363 | 47.3723 | 289.06 | 0.00 | 414.10 | 414.10 |
| CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | 476.100 | 476.100 | 0.014006 | 0.00001041 | 9.942 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 476.10 | 476.10 | 0.014006 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00738859 | 47.4040 | 333.21 | 0.00 | 476.90 | 476.90 |
| CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000108 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000108 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000104 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000104 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000156 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000156 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000107 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000107 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000108 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000108 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000152 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000152 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_LAB_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_1_F4 ZN VAV TERMINAL | 584.077 | 584.077 | 0.017453 | 0.00001278 | 12.139 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 584.08 | 584.08 | 0.017453 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00629549 | 40.4596 | 406.36 | 0.00 | 585.06 | 585.06 |
| CB_LAB_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_2_F4 ZN VAV TERMINAL | 26.389 | 26.389 | 0.007751 | 0.00000058 | 0.428 | 8/21 00:10:00 | 8/21 00:10:00 | 26.39 | 26.39 | 0.007751 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 26.43 | 26.43 | ||
| CB_LAB_3_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_3_F4 ZN VAV TERMINAL | 26.390 | 26.390 | 0.007751 | 0.00000058 | 0.428 | 8/21 00:10:00 | 8/21 00:10:00 | 26.39 | 26.39 | 0.007751 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 26.43 | 26.43 | ||
| CB_LAB_4_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_4_F4 ZN VAV TERMINAL | 662.664 | 662.664 | 0.019791 | 0.00001449 | 13.774 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 662.66 | 662.66 | 0.019791 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00638160 | 41.0074 | 461.11 | 0.00 | 663.78 | 663.78 |
| CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | 3128.015 | 3128.015 | 0.092579 | 0.00006842 | 65.199 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3128.02 | 3128.02 | 0.092579 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754174 | 48.3729 | 2183.19 | 0.00 | 3133.27 | 3133.27 |
| CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | 3281.339 | 3281.339 | 0.096542 | 0.00007177 | 68.519 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3281.34 | 3281.34 | 0.096542 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00761081 | 48.8108 | 2295.97 | 0.00 | 3286.86 | 3286.86 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | 2445.034 | 2445.034 | 0.108405 | 0.00005348 | 46.580 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 2445.03 | 2445.03 | 0.108405 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00733877 | 47.0862 | 1339.11 | 0.00 | 2449.60 | 2449.60 |
| CB_MAIN_STAIRS_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | 411.421 | 411.421 | 0.012167 | 0.00000900 | 8.578 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 411.42 | 411.42 | 0.012167 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00764527 | 49.0291 | 287.23 | 0.00 | 412.11 | 412.11 |
| CB_MAIN_STAIRS_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | 470.703 | 470.703 | 0.013893 | 0.00001030 | 9.819 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 470.70 | 470.70 | 0.013893 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00755917 | 48.4839 | 328.92 | 0.00 | 471.49 | 471.49 |
| CB_MAIN_STAIRS_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | 562.846 | 562.846 | 0.016566 | 0.00001231 | 11.752 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 562.85 | 562.85 | 0.016566 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00755435 | 48.4536 | 393.78 | 0.00 | 563.79 | 563.79 |
| CB_MAIN_STAIRS_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | 701.796 | 701.796 | 0.020578 | 0.00001535 | 14.670 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 701.80 | 701.80 | 0.020578 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00758288 | 48.6346 | 491.78 | 0.00 | 702.98 | 702.98 |
| CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | 329.836 | 329.836 | 0.009756 | 0.00000721 | 6.876 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 329.84 | 329.84 | 0.009756 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00753345 | 48.3212 | 230.28 | 0.00 | 330.39 | 330.39 |
| CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | 337.723 | 337.723 | 0.009986 | 0.00000739 | 7.041 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 337.72 | 337.72 | 0.009986 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754065 | 48.3668 | 235.82 | 0.00 | 338.29 | 338.29 |
| CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | 338.518 | 338.518 | 0.010009 | 0.00000740 | 7.058 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 338.52 | 338.52 | 0.010009 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754138 | 48.3714 | 236.38 | 0.00 | 339.09 | 339.09 |
| CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | 338.625 | 338.625 | 0.010012 | 0.00000741 | 7.060 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 338.62 | 338.62 | 0.010012 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754148 | 48.3721 | 236.45 | 0.00 | 339.19 | 339.19 |
| CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | 338.534 | 338.534 | 0.010009 | 0.00000740 | 7.058 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 338.53 | 338.53 | 0.010009 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754138 | 48.3715 | 236.39 | 0.00 | 339.10 | 339.10 |
| CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | 338.277 | 338.277 | 0.010002 | 0.00000740 | 7.053 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 338.28 | 338.28 | 0.010002 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00754113 | 48.3699 | 236.21 | 0.00 | 338.85 | 338.85 |
| CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | 336.694 | 336.694 | 0.009956 | 0.00000736 | 7.020 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 336.69 | 336.69 | 0.009956 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00753957 | 48.3600 | 235.10 | 0.00 | 337.26 | 337.26 |
| CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | 321.390 | 321.390 | 0.009509 | 0.00000703 | 6.699 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 321.39 | 321.39 | 0.009509 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00752426 | 48.2629 | 224.35 | 0.00 | 321.93 | 321.93 |
| CB_OFFICES_OPEN_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_OFFICES_OPEN_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_OFFICES_OPEN_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_OFFICES_OPEN_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | -999.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | 27.782 | 27.782 | 0.001817 | 0.00000061 | 0.505 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 27.78 | 27.78 | 0.001817 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00588917 | 37.8724 | 9.29 | 0.00 | 27.84 | 27.84 |
| CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | 384.196 | 384.196 | 0.011330 | 0.00000840 | 8.017 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 384.20 | 384.20 | 0.011330 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00758586 | 48.6532 | 268.56 | 0.00 | 384.84 | 384.84 |
| CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | 452.531 | 452.531 | 0.013314 | 0.00000990 | 9.449 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 452.53 | 452.53 | 0.013314 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00757984 | 48.6153 | 316.65 | 0.00 | 453.29 | 453.29 |
| CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | 551.133 | 551.133 | 0.016158 | 0.00001205 | 11.521 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 551.13 | 551.13 | 0.016158 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00760156 | 48.7531 | 386.23 | 0.00 | 552.06 | 552.06 |
| CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | 381.943 | 381.943 | 0.011273 | 0.00000835 | 7.968 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 381.94 | 381.94 | 0.011273 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00770228 | 49.3904 | 266.87 | 0.00 | 382.59 | 382.59 |
| CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | 454.977 | 454.977 | 0.013382 | 0.00000995 | 9.501 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 454.98 | 454.98 | 0.013382 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00763891 | 48.9894 | 318.38 | 0.00 | 455.74 | 455.74 |
| CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | 470.804 | 470.804 | 0.013844 | 0.00001030 | 9.833 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 470.80 | 470.80 | 0.013844 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00759295 | 48.6984 | 329.51 | 0.00 | 471.60 | 471.60 |
| CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | 562.943 | 562.943 | 0.016495 | 0.00001231 | 11.770 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 562.94 | 562.94 | 0.016495 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00760953 | 48.8036 | 394.59 | 0.00 | 563.89 | 563.89 |
| CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000108 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000108 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000120 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000120 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STORAGE_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STORAGE_F1 ZN VAV TERMINAL | 597.531 | 597.531 | 0.017813 | 0.00001307 | 12.428 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 597.53 | 597.53 | 0.017813 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00739946 | 47.4709 | 415.79 | 0.00 | 598.53 | 598.53 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000206 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000206 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000193 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000193 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000190 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000190 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000275 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000275 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000235 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000235 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000220 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000220 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | 0.000 | 0.000 | 0.000219 | 0.00000000 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 0.00 | 0.00 | 0.000219 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | ||
| CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | 1.117 | 1.117 | 0.000328 | 0.00000002 | 1.000 | 8/21 00:10:00 | 8/21 00:10:00 | 1.12 | 1.12 | 0.000328 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 26.00 | 0.01652405 | 23.01 | 0.0000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 7.08 | 7.08 | ||
| CB_STUDIO_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_1_F2 ZN VAV TERMINAL | 2768.572 | 2768.572 | 0.082101 | 0.00006056 | 57.672 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 2768.57 | 2768.57 | 0.082101 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00732609 | 47.0059 | 1931.02 | 0.00 | 2773.22 | 2773.22 |
| CB_STUDIO_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_1_F3 ZN VAV TERMINAL | 3091.090 | 3091.090 | 0.091453 | 0.00006761 | 64.436 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3091.09 | 3091.09 | 0.091453 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00728393 | 46.7386 | 2158.21 | 0.00 | 3096.29 | 3096.29 |
| CB_STUDIO_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_2_F2 ZN VAV TERMINAL | 3364.833 | 3364.833 | 0.099556 | 0.00007360 | 70.142 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3364.83 | 3364.83 | 0.099556 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00741410 | 47.5640 | 2349.05 | 0.00 | 3370.49 | 3370.49 |
| CB_STUDIO_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_2_F3 ZN VAV TERMINAL | 2887.018 | 2887.018 | 0.085472 | 0.00006315 | 60.170 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 2887.02 | 2887.02 | 0.085472 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00725019 | 46.5247 | 2015.20 | 0.00 | 2891.87 | 2891.87 |
| CB_UTILITY_F1 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F1 ZN VAV TERMINAL | 30.852 | 30.852 | 0.001275 | 0.00000067 | 0.595 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 30.85 | 30.85 | 0.001275 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00794059 | 50.8982 | 17.83 | 0.00 | 30.91 | 30.91 |
| CB_UTILITY_F2 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F2 ZN VAV TERMINAL | 45.618 | 45.618 | 0.001361 | 0.00000100 | 0.949 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 45.62 | 45.62 | 0.001361 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00799997 | 51.2740 | 31.71 | 0.00 | 45.69 | 45.69 |
| CB_UTILITY_F3 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F3 ZN VAV TERMINAL | 71.338 | 71.338 | 0.002124 | 0.00000156 | 1.484 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 71.34 | 71.34 | 0.002124 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00800000 | 51.2742 | 49.64 | 0.00 | 71.46 | 71.46 |
| CB_UTILITY_F4 ZN REHEAT COIL | COIL:HEATING:WATER | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F4 ZN VAV TERMINAL | 146.950 | 146.950 | 0.004350 | 0.00000321 | 3.063 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 146.95 | 146.95 | 0.004350 | 12.78 | 11.57 | 0.00800000 | 40.00 | 21.16 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 0.0000 | 21.11 | 0.00800000 | 51.2742 | 102.52 | 0.00 | 147.20 | 147.20 |
| VAV_1 CLG COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_1 | 110731.597 | -999.000 | 5.613586 | 0.00470145 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | 110731.60 | 91971.63 | 5.613586 | 24.37 | 17.38 | 0.00954677 | 10.91 | 10.91 | 0.00850000 | 33.90 | 0.01653638 | 25.12 | 4.8746 | 23.89 | 0.00918859 | 49.6600 | 66523.78 | 0.00 | 110874.80 | 87136.63 |
| VAV_1 MAIN HTG COIL | Coil:Heating:Water | AirLoopHVAC | VAV_1 | 1836.260 | 1836.260 | 1.684076 | 0.00004016 | 28.694 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 1836.26 | 1836.26 | 1.684076 | 11.88 | 9.43 | 0.00634638 | 12.78 | 11.57 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 16.2488 | 22.00 | 0.00606131 | 36.8999 | 2113.95 | 0.00 | 1960.44 | 1960.44 |
| VAV_2 CLG COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_2 | 94101.465 | -999.000 | 4.794329 | 0.00399537 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 94101.46 | 77393.01 | 4.794329 | 24.17 | 17.35 | 0.00959068 | 10.90 | 10.90 | 0.00850000 | 33.43 | 0.01653549 | 24.99 | 3.0114 | 23.89 | 0.00937505 | 50.6532 | 56814.35 | 0.00 | 94224.02 | 73345.75 |
| VAV_2 MAIN HTG COIL | Coil:Heating:Water | AirLoopHVAC | VAV_2 | 4167.512 | 4167.512 | 1.438299 | 0.00009116 | 64.725 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4167.51 | 4167.51 | 1.438299 | 10.38 | 8.58 | 0.00619839 | 12.78 | 11.57 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 10.0379 | 21.78 | 0.00595270 | 36.7472 | 1458.92 | 0.00 | 4356.41 | 4356.41 |
| VAV_3 CLG COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_3 | 93505.248 | -999.000 | 4.750306 | 0.00397005 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | 93505.25 | 76688.45 | 4.750306 | 24.18 | 17.37 | 0.00960807 | 10.90 | 10.90 | 0.00850000 | 33.43 | 0.01653549 | 24.99 | 3.0393 | 23.89 | 0.00939092 | 50.7378 | 56292.56 | 0.00 | 93627.16 | 72705.82 |
| VAV_3 MAIN HTG COIL | Coil:Heating:Water | AirLoopHVAC | VAV_3 | 4357.775 | 4357.775 | 1.425092 | 0.00009532 | 67.644 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 4357.77 | 4357.77 | 1.425092 | 10.25 | 8.57 | 0.00624713 | 12.78 | 11.57 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 10.1309 | 21.53 | 0.00589641 | 36.9488 | 1695.53 | 0.00 | 4546.87 | 4546.87 |
| VAV_4 CLG COIL | Coil:Cooling:Water | AirLoopHVAC | VAV_4 | 128788.382 | -999.000 | 7.024432 | 0.00546811 | -999.000 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | 128788.38 | 112876.08 | 7.024432 | 24.10 | 17.01 | 0.00920791 | 10.92 | 10.92 | 0.00850000 | 33.58 | 0.01653578 | 25.03 | 2.1682 | 23.89 | 0.00904550 | 48.8963 | 83025.18 | 0.00 | 129004.34 | 106091.49 |
| VAV_4 MAIN HTG COIL | Coil:Heating:Water | AirLoopHVAC | VAV_4 | 3631.300 | 3631.300 | 2.107330 | 0.00007943 | 56.620 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | 3631.30 | 3631.30 | 2.107330 | 11.35 | 9.26 | 0.00641471 | 12.78 | 11.57 | 0.00800000 | 4.60 | 0.00525715 | 4.59 | 7.2273 | 21.21 | 0.00582201 | 37.2098 | 1747.45 | 0.00 | 3848.13 | 3848.13 |
Report: Coil Sizing Details
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Coils| Coil Type | Coil Location | HVAC Type | HVAC Name | Zone Name(s) | System Sizing Method Concurrence | System Sizing Method Capacity | System Sizing Method Air Flow | Autosized Coil Capacity? | Autosized Coil Airflow? | Autosized Coil Water Flow? | OA Pretreated prior to coil inlet? | Coil Final Gross Total Capacity [W] | Coil Final Gross Sensible Capacity [W] | Coil Final Reference Air Volume Flow Rate [m3/s] | Coil Final Reference Plant Fluid Volume Flow Rate [m3/s] | Coil U-value Times Area Value [W/K] | Terminal Unit Reheat Coil Multiplier | DX Coil Capacity Increase Ratio from Too Low Flow/Capacity Ratio | DX Coil Capacity Decrease Ratio from Too High Flow/Capacity Ratio | Moist Air Heat Capacity [J/kg-K] | Dry Air Heat Capacity [J/kg-K] | Standard Air Density Adjusted for Elevation [kg/m3] | Supply Fan Name for Coil | Supply Fan Type for Coil | Supply Fan Maximum Air Volume Flow Rate [m3/s] | Supply Fan Maximum Air Mass Flow Rate [kg/s] | Plant Name for Coil | Plant Fluid Specific Heat Capacity [J/kg-K] | Plant Fluid Density [kg/m3] | Plant Maximum Fluid Mass Flow Rate [kg/s] | Plant Design Fluid Return Temperature [C] | Plant Design Fluid Supply Temperature [C] | Plant Design Fluid Temperature Difference [deltaC] | Plant Design Capacity [W] | Coil Capacity Percentage of Plant Design Capacity [%] | Coil Fluid Flow Rate Percentage of Plant Design Flow Rate [%] | Design Day Name at Sensible Ideal Loads Peak | Date/Time at Sensible Ideal Loads Peak | Design Day Name at Total Ideal Loads Peak | Date/Time at Total Ideal Loads Peak | Design Day Name at Air Flow Ideal Loads Peak | Date/Time at Air Flow Ideal Loads Peak | Peak Load Type to Size On | Coil Total Capacity at Ideal Loads Peak [W] | Coil Sensible Capacity at Ideal Loads Peak [W] | Coil Off-Rating Capacity Modifier at Ideal Loads Peak [ ] | Coil Air Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Coil Entering Air Drybulb at Ideal Loads Peak [C] | Coil Entering Air Wetbulb at Ideal Loads Peak [C] | Coil Entering Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Leaving Air Drybulb at Ideal Loads Peak [C] | Coil Leaving Air Wetbulb at Ideal Loads Peak [C] | Coil Leaving Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Ideal Loads Peak [J/KG-K] | Coil Plant Fluid Mass Flow Rate at Ideal Loads Peak [kg/s] | Coil Entering Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Leaving Plant Fluid Temperature at Ideal Loads Peak [C] | Coil Plant Fluid Temperature Difference at Ideal Loads Peak [deltaC] | Supply Fan Air Heat Gain at Ideal Loads Peak [W] | Coil and Fan Net Total Capacity at Ideal Loads Peak [W] | Outdoor Air Drybulb at Ideal Loads Peak [C] | Outdoor Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Outdoor Air Wetbulb at Ideal Loads Peak [C] | Outdoor Air Volume Flow Rate at Ideal Loads Peak [m3/s] | Outdoor Air Flow Percentage at Ideal Loads Peak [%] | System Return Air Drybulb at Ideal Loads Peak [C] | System Return Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Drybulb at Ideal Loads Peak [C] | Zone Air Humidity Ratio at Ideal Loads Peak [kgWater/kgDryAir] | Zone Air Relative Humidity at Ideal Loads Peak [%] | Zone Sensible Heat Gain at Ideal Loads Peak [W] | Zone Latent Heat Gain at Ideal Loads Peak [W] | Coil Total Capacity at Rating Conditions [W] | Coil Sensible Capacity at Rating Conditions [W] | Coil Air Mass Flow Rate at Rating Conditions [kg/s] | Coil Entering Air Drybulb at Rating Conditions [C] | Coil Entering Air Wetbulb at Rating Conditions [C] | Coil Entering Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Entering Air Enthalpy at Rating Conditions [J/KG-K] | Coil Leaving Air Drybulb at Rating Conditions [C] | Coil Leaving Air Wetbulb at Rating Conditions [C] | Coil Leaving Air Humidity Ratio at Rating Conditions [kgWater/kgDryAir] | Coil Leaving Air Enthalpy at Rating Conditions [J/KG-K] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CAFE_STUDY_LOUNGE_F1 ZN VAV TERMINAL | CB_CAFE_STUDY_LOUNGE_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 47.980 | 47.980 | 0.014092 | 0.00000105 | 0.778 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0506 | 0.051632 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 47.98 | 47.98 | 1.0000 | 0.01693874 | 0.014092 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00104934 | 60.00 | 48.89 | 11.11 | 0.000 | 47.98 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 48.05 | 48.05 | 0.01693874 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 15.56 | 12.73 | 0.00800000 | 35873.6 | |||
| CB_CLASSROOM_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_1_F2 ZN VAV TERMINAL | CB_CLASSROOM_1_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 2322.417 | 2322.417 | 0.067860 | 0.00005080 | 48.599 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.4499 | 2.499227 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 2322.42 | 2322.42 | 1.0000 | 0.08156889 | 0.067860 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.05079268 | 60.00 | 48.89 | 11.11 | 0.000 | 2322.42 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.88 | 0.00754139 | 21.11 | 0.00754139 | 48.3721 | 1629.92 | 0.00 | 2326.33 | 2326.33 | 0.08156889 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.75 | 21.40 | 0.00800000 | 61557.0 | |
| CB_CLASSROOM_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_1_F3 ZN VAV TERMINAL | CB_CLASSROOM_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 2469.414 | 2469.414 | 0.072088 | 0.00005401 | 51.690 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.6050 | 2.657414 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 2469.41 | 2469.41 | 1.0000 | 0.08665119 | 0.072088 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.05400758 | 60.00 | 48.89 | 11.11 | 0.000 | 2469.41 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.87 | 0.00749720 | 21.11 | 0.00749720 | 48.0925 | 1733.83 | 0.00 | 2473.57 | 2473.57 | 0.08665119 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.77 | 21.41 | 0.00800000 | 61583.5 | |
| CB_CLASSROOM_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_1_F4 ZN VAV TERMINAL | CB_CLASSROOM_1_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 3495.128 | 3495.128 | 0.101638 | 0.00007645 | 73.249 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.6870 | 3.761217 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3495.13 | 3495.13 | 1.0000 | 0.12217186 | 0.101638 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.07644057 | 60.00 | 48.89 | 11.11 | 0.000 | 3495.13 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.84 | 0.00752665 | 21.11 | 0.00752665 | 48.2790 | 2457.96 | 0.00 | 3501.02 | 3501.02 | 0.12217186 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.88 | 21.44 | 0.00800000 | 61693.7 | |
| CB_CLASSROOM_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_2_F2 ZN VAV TERMINAL | CB_CLASSROOM_2_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 962.556 | 962.556 | 0.028395 | 0.00002105 | 20.083 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.0154 | 1.035837 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 962.56 | 962.56 | 1.0000 | 0.03413118 | 0.028395 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.02105169 | 60.00 | 48.89 | 11.11 | 0.000 | 962.56 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.71 | 0.00753356 | 21.11 | 0.00753356 | 48.3213 | 672.78 | 0.00 | 964.17 | 964.17 | 0.03413118 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.48 | 21.32 | 0.00800000 | 61286.3 | |
| CB_CLASSROOM_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_2_F3 ZN VAV TERMINAL | CB_CLASSROOM_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1040.991 | 1040.991 | 0.030692 | 0.00002277 | 21.723 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.0981 | 1.120243 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1040.99 | 1040.99 | 1.0000 | 0.03689210 | 0.030692 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.02276710 | 60.00 | 48.89 | 11.11 | 0.000 | 1040.99 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.95 | 0.00748966 | 21.11 | 0.00748966 | 48.0432 | 727.80 | 0.00 | 1042.74 | 1042.74 | 0.03689210 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.50 | 21.33 | 0.00800000 | 61301.8 | |
| CB_CLASSROOM_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_2_F4 ZN VAV TERMINAL | CB_CLASSROOM_2_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1909.954 | 1909.954 | 0.056008 | 0.00004178 | 39.924 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.0148 | 2.055361 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1909.95 | 1909.95 | 1.0000 | 0.06732247 | 0.056008 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.04177185 | 60.00 | 48.89 | 11.11 | 0.000 | 1909.95 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.90 | 0.00754832 | 21.11 | 0.00754832 | 48.4151 | 1338.37 | 0.00 | 1913.17 | 1913.17 | 0.06732247 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.65 | 21.37 | 0.00800000 | 61455.2 | |
| CB_CLASSROOM_3_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_3_F2 ZN VAV TERMINAL | CB_CLASSROOM_3_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 847.995 | 847.995 | 0.025059 | 0.00001855 | 17.684 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.8946 | 0.912554 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 848.00 | 848.00 | 1.0000 | 0.03012102 | 0.025059 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01854617 | 60.00 | 48.89 | 11.11 | 0.000 | 848.00 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.76 | 0.00749227 | 21.11 | 0.00749227 | 48.0596 | 592.28 | 0.00 | 849.42 | 849.42 | 0.03012102 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.43 | 21.31 | 0.00800000 | 61237.4 | |
| CB_CLASSROOM_3_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_3_F3 ZN VAV TERMINAL | CB_CLASSROOM_3_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 899.292 | 899.292 | 0.026559 | 0.00001967 | 18.757 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.9487 | 0.967757 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 899.29 | 899.29 | 1.0000 | 0.03192476 | 0.026559 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01966807 | 60.00 | 48.89 | 11.11 | 0.000 | 899.29 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.74 | 0.00743857 | 21.11 | 0.00743857 | 47.7193 | 628.30 | 0.00 | 900.80 | 900.80 | 0.03192476 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.45 | 21.31 | 0.00800000 | 61253.7 | |
| CB_CLASSROOM_3_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_3_F4 ZN VAV TERMINAL | CB_CLASSROOM_3_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1815.086 | 1815.086 | 0.053270 | 0.00003970 | 37.931 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.9147 | 1.953271 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1815.09 | 1815.09 | 1.0000 | 0.06403247 | 0.053270 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.03969704 | 60.00 | 48.89 | 11.11 | 0.000 | 1815.09 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.91 | 0.00753111 | 21.11 | 0.00753111 | 48.3060 | 1271.45 | 0.00 | 1818.14 | 1818.14 | 0.06403247 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.62 | 21.37 | 0.00800000 | 61431.2 | |
| CB_CLASSROOM_4_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_4_F2 ZN VAV TERMINAL | CB_CLASSROOM_4_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 862.852 | 862.852 | 0.025503 | 0.00001887 | 17.992 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.9102 | 0.928542 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 862.85 | 862.85 | 1.0000 | 0.03065516 | 0.025503 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01887110 | 60.00 | 48.89 | 11.11 | 0.000 | 862.85 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.76 | 0.00749951 | 21.11 | 0.00749951 | 48.1054 | 602.60 | 0.00 | 864.30 | 864.30 | 0.03065516 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.43 | 21.31 | 0.00800000 | 61231.5 | |
| CB_CLASSROOM_4_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_4_F3 ZN VAV TERMINAL | CB_CLASSROOM_4_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 938.946 | 938.946 | 0.027729 | 0.00002054 | 19.584 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.9905 | 1.010429 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 938.95 | 938.95 | 1.0000 | 0.03333098 | 0.027729 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.02053532 | 60.00 | 48.89 | 11.11 | 0.000 | 938.95 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.98 | 0.00745573 | 21.11 | 0.00745573 | 47.8280 | 656.00 | 0.00 | 940.53 | 940.53 | 0.03333098 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.45 | 21.32 | 0.00800000 | 61254.9 | |
| CB_CLASSROOM_4_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_4_F4 ZN VAV TERMINAL | CB_CLASSROOM_4_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1947.869 | 1947.869 | 0.057136 | 0.00004261 | 40.712 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.0548 | 2.096163 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1947.87 | 1947.87 | 1.0000 | 0.06867865 | 0.057136 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.04260107 | 60.00 | 48.89 | 11.11 | 0.000 | 1947.87 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00755951 | 21.11 | 0.00755951 | 48.4861 | 1364.76 | 0.00 | 1951.15 | 1951.15 | 0.06867865 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.64 | 21.37 | 0.00800000 | 61447.0 | |
| CB_CLASSROOM_5_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_5_F2 ZN VAV TERMINAL | CB_CLASSROOM_5_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 694.827 | 694.827 | 0.020574 | 0.00001520 | 14.481 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.7330 | 0.747725 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 694.83 | 694.83 | 1.0000 | 0.02473082 | 0.020574 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01519628 | 60.00 | 48.89 | 11.11 | 0.000 | 694.83 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.82 | 0.00740689 | 21.11 | 0.00740689 | 47.5183 | 484.91 | 0.00 | 695.99 | 695.99 | 0.02473082 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.38 | 21.29 | 0.00800000 | 61180.0 | |
| CB_CLASSROOM_5_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_5_F3 ZN VAV TERMINAL | CB_CLASSROOM_5_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 827.197 | 827.197 | 0.024452 | 0.00001809 | 17.248 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.8726 | 0.890173 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 827.20 | 827.20 | 1.0000 | 0.02939175 | 0.024452 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01809130 | 60.00 | 48.89 | 11.11 | 0.000 | 827.20 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.77 | 0.00740045 | 21.11 | 0.00740045 | 47.4776 | 577.72 | 0.00 | 828.59 | 828.59 | 0.02939175 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61228.3 | |
| CB_CLASSROOM_5_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_5_F4 ZN VAV TERMINAL | CB_CLASSROOM_5_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1931.033 | 1931.033 | 0.056615 | 0.00004224 | 40.366 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.0370 | 2.078045 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1931.03 | 1931.03 | 1.0000 | 0.06805283 | 0.056615 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.04223286 | 60.00 | 48.89 | 11.11 | 0.000 | 1931.03 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00755236 | 21.11 | 0.00755236 | 48.4407 | 1353.25 | 0.00 | 1934.28 | 1934.28 | 0.06805283 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.65 | 21.37 | 0.00800000 | 61460.4 | |
| CB_CLASSROOM_6_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_6_F2 ZN VAV TERMINAL | CB_CLASSROOM_6_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 383.009 | 383.009 | 0.011410 | 0.00000838 | 7.967 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4040 | 0.412168 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 383.01 | 383.01 | 1.0000 | 0.01371510 | 0.011410 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00837663 | 60.00 | 48.89 | 11.11 | 0.000 | 383.01 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00711704 | 21.11 | 0.00711704 | 45.6797 | 266.65 | 0.00 | 383.65 | 383.65 | 0.01371510 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.21 | 21.24 | 0.00800000 | 61010.1 | |
| CB_CLASSROOM_6_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_6_F3 ZN VAV TERMINAL | CB_CLASSROOM_6_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 834.331 | 834.331 | 0.024661 | 0.00001825 | 17.397 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.8801 | 0.897850 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 834.33 | 834.33 | 1.0000 | 0.02964305 | 0.024661 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01824733 | 60.00 | 48.89 | 11.11 | 0.000 | 834.33 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.77 | 0.00740685 | 21.11 | 0.00740685 | 47.5182 | 582.72 | 0.00 | 835.73 | 835.73 | 0.02964305 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.43 | 21.31 | 0.00800000 | 61230.4 | |
| CB_CLASSROOM_6_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_6_F4 ZN VAV TERMINAL | CB_CLASSROOM_6_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 3540.882 | 3540.882 | 0.102939 | 0.00007745 | 74.215 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.7353 | 3.810455 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3540.88 | 3540.88 | 1.0000 | 0.12373510 | 0.102939 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.07744125 | 60.00 | 48.89 | 11.11 | 0.000 | 3540.88 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.83 | 0.00753172 | 21.11 | 0.00753172 | 48.3111 | 2490.43 | 0.00 | 3546.85 | 3546.85 | 0.12373510 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.89 | 21.44 | 0.00800000 | 61702.1 | |
| CB_CLASSROOM_7_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_7_F2 ZN VAV TERMINAL | CB_CLASSROOM_7_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 299.075 | 299.075 | 0.008923 | 0.00000654 | 6.219 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3155 | 0.321844 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 299.08 | 299.08 | 1.0000 | 0.01072545 | 0.008923 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00654095 | 60.00 | 48.89 | 11.11 | 0.000 | 299.08 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.07 | 0.00694160 | 21.11 | 0.00694160 | 44.5661 | 208.11 | 0.00 | 299.58 | 299.58 | 0.01072545 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.17 | 21.23 | 0.00800000 | 60968.6 | |
| CB_CLASSROOM_7_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_7_F3 ZN VAV TERMINAL | CB_CLASSROOM_7_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 960.825 | 960.825 | 0.028356 | 0.00002102 | 20.044 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.0136 | 1.033975 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 960.83 | 960.83 | 1.0000 | 0.03408478 | 0.028356 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.02101384 | 60.00 | 48.89 | 11.11 | 0.000 | 960.83 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00745715 | 21.11 | 0.00745715 | 47.8371 | 671.48 | 0.00 | 962.44 | 962.44 | 0.03408478 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.47 | 21.32 | 0.00800000 | 61273.9 | |
| CB_CLASSROOM_8_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_8_F2 ZN VAV TERMINAL | CB_CLASSROOM_8_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1590.300 | 1590.300 | 0.046835 | 0.00003478 | 33.198 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.6776 | 1.711372 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1590.30 | 1590.30 | 1.0000 | 0.05629662 | 0.046835 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.03478082 | 60.00 | 48.89 | 11.11 | 0.000 | 1590.30 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.93 | 0.00739189 | 21.11 | 0.00739189 | 47.4243 | 1112.48 | 0.00 | 1592.98 | 1592.98 | 0.05629662 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.53 | 21.34 | 0.00800000 | 61333.3 | |
| CB_CLASSROOM_8_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CLASSROOM_8_F3 ZN VAV TERMINAL | CB_CLASSROOM_8_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 2365.077 | 2365.077 | 0.069103 | 0.00005173 | 49.492 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.4949 | 2.545134 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 2365.08 | 2365.08 | 1.0000 | 0.08306396 | 0.069103 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.05172568 | 60.00 | 48.89 | 11.11 | 0.000 | 2365.08 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.88 | 0.00747987 | 21.11 | 0.00747987 | 47.9826 | 1659.97 | 0.00 | 2369.06 | 2369.06 | 0.08306396 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.75 | 21.40 | 0.00800000 | 61558.1 | |
| CB_CONFERENCE_ROOM_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL | CB_CONFERENCE_ROOM_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_CONFERENCE_ROOM_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL | CB_CONFERENCE_ROOM_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_CONFERENCE_ROOM_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL | CB_CONFERENCE_ROOM_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_CONFERENCE_ROOM_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL | CB_CONFERENCE_ROOM_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_CORRIDOR_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_1_F3 ZN VAV TERMINAL | CB_CORRIDOR_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 562.897 | 562.897 | 0.016646 | 0.00001231 | 11.736 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.5938 | 0.605752 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 562.90 | 562.90 | 1.0000 | 0.02000858 | 0.016646 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01231091 | 60.00 | 48.89 | 11.11 | 0.000 | 562.90 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.99 | 0.00757133 | 21.11 | 0.00757133 | 48.5606 | 393.01 | 0.00 | 563.84 | 563.84 | 0.02000858 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.41 | 21.30 | 0.00800000 | 61217.3 | |
| CB_CORRIDOR_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_2_F3 ZN VAV TERMINAL | CB_CORRIDOR_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 30.341 | 30.341 | 0.008911 | 0.00000066 | 0.492 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0320 | 0.032651 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 30.34 | 30.34 | 1.0000 | 0.01071153 | 0.008911 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00066357 | 60.00 | 48.89 | 11.11 | 0.000 | 30.34 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 30.38 | 30.38 | 0.01071153 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 15.56 | 12.73 | 0.00800000 | 35873.6 | |||
| CB_CORRIDOR_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_F1 ZN VAV TERMINAL | CB_CORRIDOR_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 192.648 | 192.648 | 0.017871 | 0.00000421 | 3.368 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.2032 | 0.207315 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 06:20:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 06:20:00 | Sensible | 192.65 | 192.65 | 1.0000 | 0.02148181 | 0.017871 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00421333 | 60.00 | 48.89 | 11.11 | 0.000 | 192.65 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.11 | 0.00526156 | 21.11 | 0.00526156 | 33.8665 | 10.98 | 0.00 | 192.87 | 192.87 | 0.02148181 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 21.58 | 15.07 | 0.00800000 | 42015.3 | |
| CB_CORRIDOR_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_F2 ZN VAV TERMINAL | CB_CORRIDOR_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 188.544 | 188.544 | 0.012883 | 0.00000412 | 3.417 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.1989 | 0.202898 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 188.54 | 188.54 | 1.0000 | 0.01548529 | 0.012883 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00412357 | 60.00 | 48.89 | 11.11 | 0.000 | 188.54 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.10 | 0.00592739 | 21.11 | 0.00592739 | 38.1158 | 57.45 | 0.00 | 188.93 | 188.93 | 0.01548529 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 24.74 | 16.22 | 0.00800000 | 45238.1 | |
| CB_CORRIDOR_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_CORRIDOR_F4 ZN VAV TERMINAL | CB_CORRIDOR_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1593.570 | 1593.570 | 0.047246 | 0.00003486 | 33.198 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.6811 | 1.714891 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1593.57 | 1593.57 | 1.0000 | 0.05679054 | 0.047246 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.03485235 | 60.00 | 48.89 | 11.11 | 0.000 | 1593.57 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.04 | 0.00780001 | 21.11 | 0.00780001 | 50.0085 | 1111.17 | 0.00 | 1596.25 | 1596.25 | 0.05679054 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.34 | 21.28 | 0.00800000 | 61144.8 | |
| CB_ENTRANCE_LOBBY_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_ENTRANCE_LOBBY_F1 ZN VAV TERMINAL | CB_ENTRANCE_LOBBY_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 932.281 | 932.281 | 0.027611 | 0.00002039 | 19.428 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.9835 | 1.003257 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 932.28 | 932.28 | 1.0000 | 0.03318899 | 0.027611 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.02038955 | 60.00 | 48.89 | 11.11 | 0.000 | 932.28 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.00 | 0.00755217 | 21.11 | 0.00755217 | 48.4389 | 650.49 | 0.00 | 933.85 | 933.85 | 0.03318899 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.37 | 21.29 | 0.00800000 | 61174.5 | |
| CB_FACULTY_OFFICE_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_1_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 386.246 | 386.246 | 0.011396 | 0.00000845 | 8.058 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4075 | 0.415652 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 386.25 | 386.25 | 1.0000 | 0.01369794 | 0.011396 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00844744 | 60.00 | 48.89 | 11.11 | 0.000 | 386.25 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.98 | 0.00743434 | 21.11 | 0.00743434 | 47.6935 | 269.98 | 0.00 | 386.90 | 386.90 | 0.01369794 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.48 | 21.32 | 0.00800000 | 61282.0 | |
| CB_FACULTY_OFFICE_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 415.256 | 415.256 | 0.012242 | 0.00000908 | 8.666 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4381 | 0.446870 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 415.26 | 415.26 | 1.0000 | 0.01471572 | 0.012242 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00908191 | 60.00 | 48.89 | 11.11 | 0.000 | 415.26 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00738560 | 21.11 | 0.00738560 | 47.3848 | 290.36 | 0.00 | 415.95 | 415.95 | 0.01471572 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.50 | 21.33 | 0.00800000 | 61303.2 | |
| CB_FACULTY_OFFICE_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_1_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 477.468 | 477.468 | 0.014046 | 0.00001044 | 9.971 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.5037 | 0.513819 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 477.47 | 477.47 | 1.0000 | 0.01688312 | 0.014046 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01044252 | 60.00 | 48.89 | 11.11 | 0.000 | 477.47 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.94 | 0.00738971 | 21.11 | 0.00738971 | 47.4111 | 334.18 | 0.00 | 478.27 | 478.27 | 0.01688312 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.56 | 21.35 | 0.00800000 | 61365.6 | |
| CB_FACULTY_OFFICE_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_2_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 398.937 | 398.937 | 0.011763 | 0.00000873 | 8.325 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4208 | 0.429308 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 398.94 | 398.94 | 1.0000 | 0.01413940 | 0.011763 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00872499 | 60.00 | 48.89 | 11.11 | 0.000 | 398.94 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00744604 | 21.11 | 0.00744604 | 47.7677 | 278.92 | 0.00 | 399.61 | 399.61 | 0.01413940 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.49 | 21.33 | 0.00800000 | 61299.2 | |
| CB_FACULTY_OFFICE_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 438.870 | 438.870 | 0.012927 | 0.00000960 | 9.161 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4630 | 0.472282 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 438.87 | 438.87 | 1.0000 | 0.01553857 | 0.012927 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00959835 | 60.00 | 48.89 | 11.11 | 0.000 | 438.87 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00740850 | 21.11 | 0.00740850 | 47.5300 | 306.98 | 0.00 | 439.61 | 439.61 | 0.01553857 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.52 | 21.34 | 0.00800000 | 61328.6 | |
| CB_FACULTY_OFFICE_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_2_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 588.711 | 588.711 | 0.017247 | 0.00001288 | 12.309 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6210 | 0.633531 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 588.71 | 588.71 | 1.0000 | 0.02073193 | 0.017247 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01287547 | 60.00 | 48.89 | 11.11 | 0.000 | 588.71 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00747669 | 21.11 | 0.00747669 | 47.9626 | 412.73 | 0.00 | 589.70 | 589.70 | 0.02073193 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.67 | 21.38 | 0.00800000 | 61481.3 | |
| CB_FACULTY_OFFICE_3_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_3_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 399.665 | 399.665 | 0.011784 | 0.00000874 | 8.340 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4216 | 0.430092 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 399.66 | 399.66 | 1.0000 | 0.01416441 | 0.011784 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00874091 | 60.00 | 48.89 | 11.11 | 0.000 | 399.66 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00744662 | 21.11 | 0.00744662 | 47.7713 | 279.43 | 0.00 | 400.34 | 400.34 | 0.01416441 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.50 | 21.33 | 0.00800000 | 61300.7 | |
| CB_FACULTY_OFFICE_3_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_3_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 441.711 | 441.711 | 0.013009 | 0.00000966 | 9.221 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4660 | 0.475340 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 441.71 | 441.71 | 1.0000 | 0.01563731 | 0.013009 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00966050 | 60.00 | 48.89 | 11.11 | 0.000 | 441.71 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00741113 | 21.11 | 0.00741113 | 47.5467 | 308.99 | 0.00 | 442.45 | 442.45 | 0.01563731 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.53 | 21.34 | 0.00800000 | 61332.0 | |
| CB_FACULTY_OFFICE_3_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_3_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 601.253 | 601.253 | 0.017605 | 0.00001315 | 12.574 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6343 | 0.647028 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 601.25 | 601.25 | 1.0000 | 0.02116151 | 0.017605 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01314978 | 60.00 | 48.89 | 11.11 | 0.000 | 601.25 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00748517 | 21.11 | 0.00748517 | 48.0163 | 421.62 | 0.00 | 602.27 | 602.27 | 0.02116151 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.69 | 21.39 | 0.00800000 | 61497.6 | |
| CB_FACULTY_OFFICE_4_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_4_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 399.261 | 399.261 | 0.011772 | 0.00000873 | 8.332 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4212 | 0.429657 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 399.26 | 399.26 | 1.0000 | 0.01415019 | 0.011772 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00873208 | 60.00 | 48.89 | 11.11 | 0.000 | 399.26 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.94 | 0.00744618 | 21.11 | 0.00744618 | 47.7685 | 279.15 | 0.00 | 399.93 | 399.93 | 0.01415019 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.49 | 21.33 | 0.00800000 | 61300.6 | |
| CB_FACULTY_OFFICE_4_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_4_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 442.172 | 442.172 | 0.013022 | 0.00000967 | 9.230 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4664 | 0.475835 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 442.17 | 442.17 | 1.0000 | 0.01565332 | 0.013022 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00967056 | 60.00 | 48.89 | 11.11 | 0.000 | 442.17 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00741155 | 21.11 | 0.00741155 | 47.5494 | 309.31 | 0.00 | 442.92 | 442.92 | 0.01565332 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.53 | 21.34 | 0.00800000 | 61332.5 | |
| CB_FACULTY_OFFICE_4_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_4_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 602.667 | 602.667 | 0.017645 | 0.00001318 | 12.604 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6358 | 0.648549 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 602.67 | 602.67 | 1.0000 | 0.02120958 | 0.017645 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01318070 | 60.00 | 48.89 | 11.11 | 0.000 | 602.67 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00748610 | 21.11 | 0.00748610 | 48.0222 | 422.62 | 0.00 | 603.68 | 603.68 | 0.02120958 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.69 | 21.39 | 0.00800000 | 61499.9 | |
| CB_FACULTY_OFFICE_5_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_5_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 399.157 | 399.157 | 0.011769 | 0.00000873 | 8.330 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4211 | 0.429545 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 399.16 | 399.16 | 1.0000 | 0.01414655 | 0.011769 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00872981 | 60.00 | 48.89 | 11.11 | 0.000 | 399.16 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.94 | 0.00744607 | 21.11 | 0.00744607 | 47.7679 | 279.08 | 0.00 | 399.83 | 399.83 | 0.01414655 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.49 | 21.33 | 0.00800000 | 61300.5 | |
| CB_FACULTY_OFFICE_5_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_5_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 442.302 | 442.302 | 0.013026 | 0.00000967 | 9.233 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4666 | 0.475975 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 442.30 | 442.30 | 1.0000 | 0.01565788 | 0.013026 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00967341 | 60.00 | 48.89 | 11.11 | 0.000 | 442.30 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00741168 | 21.11 | 0.00741168 | 47.5502 | 309.40 | 0.00 | 443.05 | 443.05 | 0.01565788 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.53 | 21.34 | 0.00800000 | 61332.6 | |
| CB_FACULTY_OFFICE_5_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_5_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 602.746 | 602.746 | 0.017647 | 0.00001318 | 12.605 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6358 | 0.648634 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 602.75 | 602.75 | 1.0000 | 0.02121232 | 0.017647 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01318243 | 60.00 | 48.89 | 11.11 | 0.000 | 602.75 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00748615 | 21.11 | 0.00748615 | 48.0226 | 422.68 | 0.00 | 603.76 | 603.76 | 0.02121232 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.69 | 21.39 | 0.00800000 | 61499.9 | |
| CB_FACULTY_OFFICE_6_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_6_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 399.739 | 399.739 | 0.011786 | 0.00000874 | 8.342 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4217 | 0.430172 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 399.74 | 399.74 | 1.0000 | 0.01416708 | 0.011786 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00874254 | 60.00 | 48.89 | 11.11 | 0.000 | 399.74 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00744670 | 21.11 | 0.00744670 | 47.7718 | 279.48 | 0.00 | 400.41 | 400.41 | 0.01416708 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.49 | 21.33 | 0.00800000 | 61300.7 | |
| CB_FACULTY_OFFICE_6_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_6_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 441.836 | 441.836 | 0.013013 | 0.00000966 | 9.223 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4661 | 0.475474 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 441.84 | 441.84 | 1.0000 | 0.01564170 | 0.013013 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00966323 | 60.00 | 48.89 | 11.11 | 0.000 | 441.84 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00741125 | 21.11 | 0.00741125 | 47.5475 | 309.07 | 0.00 | 442.58 | 442.58 | 0.01564170 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.53 | 21.34 | 0.00800000 | 61332.0 | |
| CB_FACULTY_OFFICE_6_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_6_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 601.312 | 601.312 | 0.017607 | 0.00001315 | 12.575 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6343 | 0.647090 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 601.31 | 601.31 | 1.0000 | 0.02116353 | 0.017607 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01315105 | 60.00 | 48.89 | 11.11 | 0.000 | 601.31 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00748521 | 21.11 | 0.00748521 | 48.0166 | 421.66 | 0.00 | 602.32 | 602.32 | 0.02116353 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.69 | 21.39 | 0.00800000 | 61497.6 | |
| CB_FACULTY_OFFICE_7_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_7_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 397.415 | 397.415 | 0.011719 | 0.00000869 | 8.293 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4192 | 0.427671 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 397.42 | 397.42 | 1.0000 | 0.01408625 | 0.011719 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00869172 | 60.00 | 48.89 | 11.11 | 0.000 | 397.42 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00744448 | 21.11 | 0.00744448 | 47.7578 | 277.85 | 0.00 | 398.08 | 398.08 | 0.01408625 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.49 | 21.33 | 0.00800000 | 61297.6 | |
| CB_FACULTY_OFFICE_7_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_7_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 438.510 | 438.510 | 0.012917 | 0.00000959 | 9.153 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4626 | 0.471894 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 438.51 | 438.51 | 1.0000 | 0.01552603 | 0.012917 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00959048 | 60.00 | 48.89 | 11.11 | 0.000 | 438.51 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.96 | 0.00740814 | 21.11 | 0.00740814 | 47.5278 | 306.73 | 0.00 | 439.25 | 439.25 | 0.01552603 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.52 | 21.34 | 0.00800000 | 61328.2 | |
| CB_FACULTY_OFFICE_7_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_7_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 588.612 | 588.612 | 0.017245 | 0.00001287 | 12.307 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6209 | 0.633424 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 588.61 | 588.61 | 1.0000 | 0.02072851 | 0.017245 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01287330 | 60.00 | 48.89 | 11.11 | 0.000 | 588.61 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.89 | 0.00747661 | 21.11 | 0.00747661 | 47.9621 | 412.66 | 0.00 | 589.60 | 589.60 | 0.02072851 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.67 | 21.38 | 0.00800000 | 61481.2 | |
| CB_FACULTY_OFFICE_8_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL | CB_FACULTY_OFFICE_8_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 380.431 | 380.431 | 0.011227 | 0.00000832 | 7.937 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4013 | 0.409393 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 380.43 | 380.43 | 1.0000 | 0.01349496 | 0.011227 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00832025 | 60.00 | 48.89 | 11.11 | 0.000 | 380.43 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.98 | 0.00742810 | 21.11 | 0.00742810 | 47.6540 | 265.88 | 0.00 | 381.07 | 381.07 | 0.01349496 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.47 | 21.32 | 0.00800000 | 61275.2 | |
| CB_FACULTY_OFFICE_8_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL | CB_FACULTY_OFFICE_8_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 413.405 | 413.405 | 0.012189 | 0.00000904 | 8.627 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4361 | 0.444878 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 413.40 | 413.40 | 1.0000 | 0.01465118 | 0.012189 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00904142 | 60.00 | 48.89 | 11.11 | 0.000 | 413.40 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00738363 | 21.11 | 0.00738363 | 47.3723 | 289.06 | 0.00 | 414.10 | 414.10 | 0.01465118 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.50 | 21.33 | 0.00800000 | 61301.1 | |
| CB_FACULTY_OFFICE_8_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL | CB_FACULTY_OFFICE_8_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 476.100 | 476.100 | 0.014006 | 0.00001041 | 9.942 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.5022 | 0.512346 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 476.10 | 476.10 | 1.0000 | 0.01683536 | 0.014006 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01041259 | 60.00 | 48.89 | 11.11 | 0.000 | 476.10 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.94 | 0.00738859 | 21.11 | 0.00738859 | 47.4040 | 333.21 | 0.00 | 476.90 | 476.90 | 0.01683536 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.56 | 21.35 | 0.00800000 | 61364.5 | |
| CB_FACULTY_RESTROOMS_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_1_F2 ZN VAV TERMINAL | CB_FACULTY_RESTROOMS_1_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000108 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00012956 | 0.000108 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00012956 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_FACULTY_RESTROOMS_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_1_F3 ZN VAV TERMINAL | CB_FACULTY_RESTROOMS_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000104 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00012466 | 0.000104 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00012466 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_FACULTY_RESTROOMS_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_1_F4 ZN VAV TERMINAL | CB_FACULTY_RESTROOMS_1_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000156 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00018779 | 0.000156 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00018779 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_FACULTY_RESTROOMS_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_2_F2 ZN VAV TERMINAL | CB_FACULTY_RESTROOMS_2_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000107 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00012851 | 0.000107 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00012851 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_FACULTY_RESTROOMS_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_2_F3 ZN VAV TERMINAL | CB_FACULTY_RESTROOMS_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000108 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00012973 | 0.000108 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00012973 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_FACULTY_RESTROOMS_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_FACULTY_RESTROOMS_2_F4 ZN VAV TERMINAL | CB_FACULTY_RESTROOMS_2_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000152 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00018316 | 0.000152 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00018316 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_LAB_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_1_F4 ZN VAV TERMINAL | CB_LAB_1_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 584.077 | 584.077 | 0.017453 | 0.00001278 | 12.139 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6161 | 0.628544 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 584.08 | 584.08 | 1.0000 | 0.02097911 | 0.017453 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01277412 | 60.00 | 48.89 | 11.11 | 0.000 | 584.08 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.08 | 0.00629549 | 21.11 | 0.00629549 | 40.4596 | 406.36 | 0.00 | 585.06 | 585.06 | 0.02097911 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.13 | 21.22 | 0.00800000 | 60924.8 | |
| CB_LAB_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_2_F4 ZN VAV TERMINAL | CB_LAB_2_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 26.389 | 26.389 | 0.007751 | 0.00000058 | 0.428 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0278 | 0.028398 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 26.39 | 26.39 | 1.0000 | 0.00931631 | 0.007751 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00057714 | 60.00 | 48.89 | 11.11 | 0.000 | 26.39 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 26.43 | 26.43 | 0.00931631 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 15.56 | 12.73 | 0.00800000 | 35873.6 | |||
| CB_LAB_3_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_3_F4 ZN VAV TERMINAL | CB_LAB_3_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 26.390 | 26.390 | 0.007751 | 0.00000058 | 0.428 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0278 | 0.028399 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 26.39 | 26.39 | 1.0000 | 0.00931679 | 0.007751 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00057717 | 60.00 | 48.89 | 11.11 | 0.000 | 26.39 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 26.43 | 26.43 | 0.00931679 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 15.56 | 12.73 | 0.00800000 | 35873.6 | |||
| CB_LAB_4_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LAB_4_F4 ZN VAV TERMINAL | CB_LAB_4_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 662.664 | 662.664 | 0.019791 | 0.00001449 | 13.774 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6990 | 0.713114 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 662.66 | 662.66 | 1.0000 | 0.02378955 | 0.019791 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01449287 | 60.00 | 48.89 | 11.11 | 0.000 | 662.66 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.07 | 0.00638160 | 21.11 | 0.00638160 | 41.0074 | 461.11 | 0.00 | 663.78 | 663.78 | 0.02378955 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.14 | 21.22 | 0.00800000 | 60939.2 | |
| CB_LECTURE_ROOM_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LECTURE_ROOM_1_F1 ZN VAV TERMINAL | CB_LECTURE_ROOM_1_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 3128.015 | 3128.015 | 0.092579 | 0.00006842 | 65.199 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.2997 | 3.366156 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3128.02 | 3128.02 | 1.0000 | 0.11128290 | 0.092579 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.06841160 | 60.00 | 48.89 | 11.11 | 0.000 | 3128.02 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.71 | 0.00754174 | 21.11 | 0.00754174 | 48.3729 | 2183.19 | 0.00 | 3133.27 | 3133.27 | 0.11128290 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.39 | 21.30 | 0.00800000 | 61193.1 | |
| CB_LECTURE_ROOM_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LECTURE_ROOM_2_F1 ZN VAV TERMINAL | CB_LECTURE_ROOM_2_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 3281.339 | 3281.339 | 0.096542 | 0.00007177 | 68.519 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.4615 | 3.531152 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3281.34 | 3281.34 | 1.0000 | 0.11604547 | 0.096542 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.07176487 | 60.00 | 48.89 | 11.11 | 0.000 | 3281.34 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.92 | 0.00761081 | 21.11 | 0.00761081 | 48.8108 | 2295.97 | 0.00 | 3286.86 | 3286.86 | 0.11604547 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.55 | 21.35 | 0.00800000 | 61361.1 | |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_LIBRARY_MEDIA_CENTER_F1 ZN VAV TERMINAL | CB_LIBRARY_MEDIA_CENTER_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 2445.034 | 2445.034 | 0.108405 | 0.00005348 | 46.580 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.5793 | 2.631179 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 2445.03 | 2445.03 | 1.0000 | 0.13030549 | 0.108405 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.05347439 | 60.00 | 48.89 | 11.11 | 0.000 | 2445.03 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.87 | 0.00733877 | 21.11 | 0.00733877 | 47.0862 | 1339.11 | 0.00 | 2449.60 | 2449.60 | 0.13030549 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 31.21 | 18.44 | 0.00800000 | 51836.1 | |
| CB_MAIN_STAIRS_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F1 ZN VAV TERMINAL | CB_MAIN_STAIRS_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 411.421 | 411.421 | 0.012167 | 0.00000900 | 8.578 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4340 | 0.442743 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 411.42 | 411.42 | 1.0000 | 0.01462525 | 0.012167 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00899802 | 60.00 | 48.89 | 11.11 | 0.000 | 411.42 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.99 | 0.00764527 | 21.11 | 0.00764527 | 49.0291 | 287.23 | 0.00 | 412.11 | 412.11 | 0.01462525 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.41 | 21.30 | 0.00800000 | 61215.3 | |
| CB_MAIN_STAIRS_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F2 ZN VAV TERMINAL | CB_MAIN_STAIRS_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 470.703 | 470.703 | 0.013893 | 0.00001030 | 9.819 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4965 | 0.506538 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 470.70 | 470.70 | 1.0000 | 0.01669946 | 0.013893 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01029455 | 60.00 | 48.89 | 11.11 | 0.000 | 470.70 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00755917 | 21.11 | 0.00755917 | 48.4839 | 328.92 | 0.00 | 471.49 | 471.49 | 0.01669946 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.47 | 21.32 | 0.00800000 | 61271.3 | |
| CB_MAIN_STAIRS_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F3 ZN VAV TERMINAL | CB_MAIN_STAIRS_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 562.846 | 562.846 | 0.016566 | 0.00001231 | 11.752 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.5937 | 0.605697 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 562.85 | 562.85 | 1.0000 | 0.01991321 | 0.016566 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01230979 | 60.00 | 48.89 | 11.11 | 0.000 | 562.85 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.94 | 0.00755435 | 21.11 | 0.00755435 | 48.4536 | 393.78 | 0.00 | 563.79 | 563.79 | 0.01991321 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.54 | 21.34 | 0.00800000 | 61349.7 | |
| CB_MAIN_STAIRS_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_MAIN_STAIRS_F4 ZN VAV TERMINAL | CB_MAIN_STAIRS_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 701.796 | 701.796 | 0.020578 | 0.00001535 | 14.670 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.7403 | 0.755225 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 701.80 | 701.80 | 1.0000 | 0.02473513 | 0.020578 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01534872 | 60.00 | 48.89 | 11.11 | 0.000 | 701.80 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.94 | 0.00758288 | 21.11 | 0.00758288 | 48.6346 | 491.78 | 0.00 | 702.98 | 702.98 | 0.02473513 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.65 | 21.37 | 0.00800000 | 61457.4 | |
| CB_OFFICES_ENCLOSED_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_1_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 329.836 | 329.836 | 0.009756 | 0.00000721 | 6.876 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3479 | 0.354946 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 329.84 | 329.84 | 1.0000 | 0.01172653 | 0.009756 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00721370 | 60.00 | 48.89 | 11.11 | 0.000 | 329.84 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00753345 | 21.11 | 0.00753345 | 48.3212 | 230.28 | 0.00 | 330.39 | 330.39 | 0.01172653 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.41 | 21.30 | 0.00800000 | 61211.7 | |
| CB_OFFICES_ENCLOSED_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_2_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 337.723 | 337.723 | 0.009986 | 0.00000739 | 7.041 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3563 | 0.363434 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 337.72 | 337.72 | 1.0000 | 0.01200289 | 0.009986 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00738620 | 60.00 | 48.89 | 11.11 | 0.000 | 337.72 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00754065 | 21.11 | 0.00754065 | 48.3668 | 235.82 | 0.00 | 338.29 | 338.29 | 0.01200289 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61221.2 | |
| CB_OFFICES_ENCLOSED_3_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_3_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 338.518 | 338.518 | 0.010009 | 0.00000740 | 7.058 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3571 | 0.364290 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 338.52 | 338.52 | 1.0000 | 0.01203071 | 0.010009 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00740360 | 60.00 | 48.89 | 11.11 | 0.000 | 338.52 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00754138 | 21.11 | 0.00754138 | 48.3714 | 236.38 | 0.00 | 339.09 | 339.09 | 0.01203071 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61222.3 | |
| CB_OFFICES_ENCLOSED_4_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_4_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 338.625 | 338.625 | 0.010012 | 0.00000741 | 7.060 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3572 | 0.364405 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 338.62 | 338.62 | 1.0000 | 0.01203444 | 0.010012 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00740593 | 60.00 | 48.89 | 11.11 | 0.000 | 338.62 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00754148 | 21.11 | 0.00754148 | 48.3721 | 236.45 | 0.00 | 339.19 | 339.19 | 0.01203444 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61222.5 | |
| CB_OFFICES_ENCLOSED_5_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_5_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 338.534 | 338.534 | 0.010009 | 0.00000740 | 7.058 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3571 | 0.364307 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 338.53 | 338.53 | 1.0000 | 0.01203123 | 0.010009 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00740393 | 60.00 | 48.89 | 11.11 | 0.000 | 338.53 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00754138 | 21.11 | 0.00754138 | 48.3715 | 236.39 | 0.00 | 339.10 | 339.10 | 0.01203123 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61222.4 | |
| CB_OFFICES_ENCLOSED_6_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_6_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 338.277 | 338.277 | 0.010002 | 0.00000740 | 7.053 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3568 | 0.364030 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 338.28 | 338.28 | 1.0000 | 0.01202224 | 0.010002 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00739831 | 60.00 | 48.89 | 11.11 | 0.000 | 338.28 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00754113 | 21.11 | 0.00754113 | 48.3699 | 236.21 | 0.00 | 338.85 | 338.85 | 0.01202224 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61222.0 | |
| CB_OFFICES_ENCLOSED_7_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_7_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 336.694 | 336.694 | 0.009956 | 0.00000736 | 7.020 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3552 | 0.362327 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 336.69 | 336.69 | 1.0000 | 0.01196689 | 0.009956 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00736370 | 60.00 | 48.89 | 11.11 | 0.000 | 336.69 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00753957 | 21.11 | 0.00753957 | 48.3600 | 235.10 | 0.00 | 337.26 | 337.26 | 0.01196689 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.42 | 21.31 | 0.00800000 | 61219.9 | |
| CB_OFFICES_ENCLOSED_8_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL | CB_OFFICES_ENCLOSED_8_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 321.390 | 321.390 | 0.009509 | 0.00000703 | 6.699 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.3390 | 0.345858 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 321.39 | 321.39 | 1.0000 | 0.01143063 | 0.009509 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00702900 | 60.00 | 48.89 | 11.11 | 0.000 | 321.39 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.97 | 0.00752426 | 21.11 | 0.00752426 | 48.2629 | 224.35 | 0.00 | 321.93 | 321.93 | 0.01143063 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.40 | 21.30 | 0.00800000 | 61201.0 | |
| CB_OFFICES_OPEN_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F1 ZN VAV TERMINAL | CB_OFFICES_OPEN_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_OFFICES_OPEN_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F2 ZN VAV TERMINAL | CB_OFFICES_OPEN_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_OFFICES_OPEN_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F3 ZN VAV TERMINAL | CB_OFFICES_OPEN_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_OFFICES_OPEN_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_OFFICES_OPEN_F4 ZN VAV TERMINAL | CB_OFFICES_OPEN_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000000 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00000000 | 0.000000 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | -999.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00000000 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_SECONDARY_STAIRS_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F1 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_1_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 27.782 | 27.782 | 0.001817 | 0.00000061 | 0.505 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0293 | 0.029897 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 27.78 | 27.78 | 1.0000 | 0.00218459 | 0.001817 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00060760 | 60.00 | 48.89 | 11.11 | 0.000 | 27.78 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.11 | 0.00588917 | 21.11 | 0.00588917 | 37.8724 | 9.29 | 0.00 | 27.84 | 27.84 | 0.00218459 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 25.27 | 16.41 | 0.00800000 | 45780.4 | |
| CB_SECONDARY_STAIRS_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F2 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_1_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 384.196 | 384.196 | 0.011330 | 0.00000840 | 8.017 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4053 | 0.413445 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 384.20 | 384.20 | 1.0000 | 0.01361858 | 0.011330 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00840260 | 60.00 | 48.89 | 11.11 | 0.000 | 384.20 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.98 | 0.00758586 | 21.11 | 0.00758586 | 48.6532 | 268.56 | 0.00 | 384.84 | 384.84 | 0.01361858 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.49 | 21.33 | 0.00800000 | 61295.8 | |
| CB_SECONDARY_STAIRS_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F3 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 452.531 | 452.531 | 0.013314 | 0.00000990 | 9.449 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4774 | 0.486983 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 452.53 | 452.53 | 1.0000 | 0.01600422 | 0.013314 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00989713 | 60.00 | 48.89 | 11.11 | 0.000 | 452.53 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.95 | 0.00757984 | 21.11 | 0.00757984 | 48.6153 | 316.65 | 0.00 | 453.29 | 453.29 | 0.01600422 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.55 | 21.35 | 0.00800000 | 61360.5 | |
| CB_SECONDARY_STAIRS_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_1_F4 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_1_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 551.133 | 551.133 | 0.016158 | 0.00001205 | 11.521 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.5814 | 0.593091 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 551.13 | 551.13 | 1.0000 | 0.01942179 | 0.016158 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01205361 | 60.00 | 48.89 | 11.11 | 0.000 | 551.13 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.91 | 0.00760156 | 21.11 | 0.00760156 | 48.7531 | 386.23 | 0.00 | 552.06 | 552.06 | 0.01942179 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.65 | 21.37 | 0.00800000 | 61462.0 | |
| CB_SECONDARY_STAIRS_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F1 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_2_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 381.943 | 381.943 | 0.011273 | 0.00000835 | 7.968 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4029 | 0.411021 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 381.94 | 381.94 | 1.0000 | 0.01355032 | 0.011273 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00835334 | 60.00 | 48.89 | 11.11 | 0.000 | 381.94 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.95 | 0.00770228 | 21.11 | 0.00770228 | 49.3904 | 266.87 | 0.00 | 382.59 | 382.59 | 0.01355032 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.47 | 21.32 | 0.00800000 | 61271.6 | |
| CB_SECONDARY_STAIRS_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F2 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_2_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 454.977 | 454.977 | 0.013382 | 0.00000995 | 9.501 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4800 | 0.489615 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 454.98 | 454.98 | 1.0000 | 0.01608583 | 0.013382 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00995063 | 60.00 | 48.89 | 11.11 | 0.000 | 454.98 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.95 | 0.00763891 | 21.11 | 0.00763891 | 48.9894 | 318.38 | 0.00 | 455.74 | 455.74 | 0.01608583 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.56 | 21.35 | 0.00800000 | 61369.1 | |
| CB_SECONDARY_STAIRS_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F3 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 470.804 | 470.804 | 0.013844 | 0.00001030 | 9.833 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.4967 | 0.506647 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 470.80 | 470.80 | 1.0000 | 0.01664143 | 0.013844 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01029676 | 60.00 | 48.89 | 11.11 | 0.000 | 470.80 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.95 | 0.00759295 | 21.11 | 0.00759295 | 48.6984 | 329.51 | 0.00 | 471.60 | 471.60 | 0.01664143 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.57 | 21.35 | 0.00800000 | 61375.8 | |
| CB_SECONDARY_STAIRS_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_SECONDARY_STAIRS_2_F4 ZN VAV TERMINAL | CB_SECONDARY_STAIRS_2_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 562.943 | 562.943 | 0.016495 | 0.00001231 | 11.770 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.5938 | 0.605801 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 562.94 | 562.94 | 1.0000 | 0.01982799 | 0.016495 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01231190 | 60.00 | 48.89 | 11.11 | 0.000 | 562.94 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.91 | 0.00760953 | 21.11 | 0.00760953 | 48.8036 | 394.59 | 0.00 | 563.89 | 563.89 | 0.01982799 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.67 | 21.38 | 0.00800000 | 61476.3 | |
| CB_STAFF_RESTROOMS_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STAFF_RESTROOMS_1_F1 ZN VAV TERMINAL | CB_STAFF_RESTROOMS_1_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000108 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00012941 | 0.000108 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00012941 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STAFF_RESTROOMS_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STAFF_RESTROOMS_2_F1 ZN VAV TERMINAL | CB_STAFF_RESTROOMS_2_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000120 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00014448 | 0.000120 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00014448 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STORAGE_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STORAGE_F1 ZN VAV TERMINAL | CB_STORAGE_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 597.531 | 597.531 | 0.017813 | 0.00001307 | 12.428 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.6303 | 0.643022 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 597.53 | 597.53 | 1.0000 | 0.02141111 | 0.017813 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.01306836 | 60.00 | 48.89 | 11.11 | 0.000 | 597.53 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.06 | 0.00739946 | 21.11 | 0.00739946 | 47.4709 | 415.79 | 0.00 | 598.53 | 598.53 | 0.02141111 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.19 | 21.24 | 0.00800000 | 60991.5 | |
| CB_STUDENTS_RESTROOMS_1_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F1 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_1_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000206 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00024730 | 0.000206 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00024730 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F2 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_1_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000193 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00023155 | 0.000193 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00023155 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F3 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000190 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00022798 | 0.000190 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00022798 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_1_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_1_F4 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_1_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000275 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00033109 | 0.000275 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00033109 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_2_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F1 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_2_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000235 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00028212 | 0.000235 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00028212 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F2 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_2_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000220 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00026391 | 0.000220 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00026391 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F3 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 0.000 | 0.000 | 0.000219 | 0.00000000 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0000 | -999.0 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 0.00 | 0.00 | 1.0000 | 0.00026308 | 0.000219 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00000000 | 60.00 | 48.89 | 11.11 | 0.000 | 0.00 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00026308 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 12.78 | 11.59 | 0.00800000 | 33037.2 | |||
| CB_STUDENTS_RESTROOMS_2_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDENTS_RESTROOMS_2_F4 ZN VAV TERMINAL | CB_STUDENTS_RESTROOMS_2_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 1.117 | 1.117 | 0.000328 | 0.00000002 | 1.000 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0012 | 0.001202 | 8/21 00:10:00 | unknown | unknown | 8/21 00:10:00 | Sensible | 1.12 | 1.12 | 1.0000 | 0.00039447 | 0.000328 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00002444 | 60.00 | 48.89 | 11.11 | 0.000 | 1.12 | 26.00 | 0.01652405 | 23.01 | 0.00000000 | 0.0000 | 15.56 | 0.00800000 | 15.56 | 0.00800000 | 72.6629 | 0.00 | 0.00 | 7.08 | 7.08 | 0.00039447 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 30.39 | 18.17 | 0.00800000 | 50993.4 | |||
| CB_STUDIO_1_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_1_F2 ZN VAV TERMINAL | CB_STUDIO_1_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 2768.572 | 2768.572 | 0.082101 | 0.00006056 | 57.672 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 2.9206 | 2.979347 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 2768.57 | 2768.57 | 1.0000 | 0.09868773 | 0.082101 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.06055035 | 60.00 | 48.89 | 11.11 | 0.000 | 2768.57 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.78 | 0.00732609 | 21.11 | 0.00732609 | 47.0059 | 1931.02 | 0.00 | 2773.22 | 2773.22 | 0.09868773 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.34 | 21.28 | 0.00800000 | 61138.2 | |
| CB_STUDIO_1_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_1_F3 ZN VAV TERMINAL | CB_STUDIO_1_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 3091.090 | 3091.090 | 0.091453 | 0.00006761 | 64.436 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.2608 | 3.326419 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3091.09 | 3091.09 | 1.0000 | 0.10992916 | 0.091453 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.06760402 | 60.00 | 48.89 | 11.11 | 0.000 | 3091.09 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.73 | 0.00728393 | 21.11 | 0.00728393 | 46.7386 | 2158.21 | 0.00 | 3096.29 | 3096.29 | 0.10992916 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.40 | 21.30 | 0.00800000 | 61203.4 | |
| CB_STUDIO_2_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_2_F2 ZN VAV TERMINAL | CB_STUDIO_2_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 3364.833 | 3364.833 | 0.099556 | 0.00007360 | 70.142 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.5496 | 3.621003 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3364.83 | 3364.83 | 1.0000 | 0.11966919 | 0.099556 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.07359095 | 60.00 | 48.89 | 11.11 | 0.000 | 3364.83 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.71 | 0.00741410 | 21.11 | 0.00741410 | 47.5640 | 2349.05 | 0.00 | 3370.49 | 3370.49 | 0.11966919 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.40 | 21.30 | 0.00800000 | 61202.2 | |
| CB_STUDIO_2_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_STUDIO_2_F3 ZN VAV TERMINAL | CB_STUDIO_2_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 2887.018 | 2887.018 | 0.085472 | 0.00006315 | 60.170 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.0455 | 3.106811 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 2887.02 | 2887.02 | 1.0000 | 0.10273950 | 0.085472 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.06314085 | 60.00 | 48.89 | 11.11 | 0.000 | 2887.02 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 20.75 | 0.00725019 | 21.11 | 0.00725019 | 46.5247 | 2015.20 | 0.00 | 2891.87 | 2891.87 | 0.10273950 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.38 | 21.29 | 0.00800000 | 61184.8 | |
| CB_UTILITY_F1 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F1 ZN VAV TERMINAL | CB_UTILITY_F1 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 30.852 | 30.852 | 0.001275 | 0.00000067 | 0.595 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0325 | 0.033201 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 30.85 | 30.85 | 1.0000 | 0.00153212 | 0.001275 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00067475 | 60.00 | 48.89 | 11.11 | 0.000 | 30.85 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.09 | 0.00794059 | 21.11 | 0.00794059 | 50.8982 | 17.83 | 0.00 | 30.91 | 30.91 | 0.00153212 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 32.56 | 18.88 | 0.00800000 | 53211.4 | |
| CB_UTILITY_F2 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F2 ZN VAV TERMINAL | CB_UTILITY_F2 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 45.618 | 45.618 | 0.001361 | 0.00000100 | 0.949 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0481 | 0.049091 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 45.62 | 45.62 | 1.0000 | 0.00163613 | 0.001361 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00099769 | 60.00 | 48.89 | 11.11 | 0.000 | 45.62 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.06 | 0.00799997 | 21.11 | 0.00799997 | 51.2740 | 31.71 | 0.00 | 45.69 | 45.69 | 0.00163613 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.17 | 21.23 | 0.00800000 | 60965.6 | |
| CB_UTILITY_F3 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F3 ZN VAV TERMINAL | CB_UTILITY_F3 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 71.338 | 71.338 | 0.002124 | 0.00000156 | 1.484 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.0753 | 0.076769 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 71.34 | 71.34 | 1.0000 | 0.00255332 | 0.002124 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00156020 | 60.00 | 48.89 | 11.11 | 0.000 | 71.34 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.04 | 0.00800000 | 21.11 | 0.00800000 | 51.2742 | 49.64 | 0.00 | 71.46 | 71.46 | 0.00255332 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.22 | 21.25 | 0.00800000 | 61023.3 | |
| CB_UTILITY_F4 ZN REHEAT COIL | COIL:HEATING:WATER | Zone Equipment | ZONEHVAC:AIRDISTRIBUTIONUNIT | ADU CB_UTILITY_F4 ZN VAV TERMINAL | CB_UTILITY_F4 ZN | N/A | N/A | N/A | Yes | Yes | Yes | No | 146.950 | 146.950 | 0.004350 | 0.00000321 | 3.063 | 1.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | unknown | unknown | -999.0 | -999.0 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 0.1550 | 0.158138 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 146.95 | 146.95 | 1.0000 | 0.00522861 | 0.004350 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 40.00 | 21.16 | 0.00800000 | 60796.0 | 0.00321389 | 60.00 | 48.89 | 11.11 | 0.000 | 146.95 | 4.60 | 0.00525715 | 4.59 | 0.00000000 | 0.0000 | 21.01 | 0.00800000 | 21.11 | 0.00800000 | 51.2742 | 102.52 | 0.00 | 147.20 | 147.20 | 0.00522861 | 12.78 | 11.59 | 0.00800000 | 33037.2 | 40.39 | 21.30 | 0.00800000 | 61189.4 | |
| VAV_1 CLG COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_1 | CB_OFFICES_ENCLOSED_1_F1 ZN; CB_OFFICES_ENCLOSED_2_F1 ZN; CB_OFFICES_ENCLOSED_3_F1 ZN; CB_OFFICES_ENCLOSED_4_F1 ZN; CB_OFFICES_ENCLOSED_5_F1 ZN; CB_OFFICES_ENCLOSED_6_F1 ZN; CB_OFFICES_ENCLOSED_7_F1 ZN; CB_OFFICES_ENCLOSED_8_F1 ZN; CB_CAFE_STUDY_LOUNGE_F1 ZN; CB_CONFERENCE_ROOM_F1 ZN; CB_CORRIDOR_F1 ZN; CB_ENTRANCE_LOBBY_F1 ZN; CB_LECTURE_ROOM_1_F1 ZN; CB_LECTURE_ROOM_2_F1 ZN; CB_LIBRARY_MEDIA_CENTER_F1 ZN; CB_MAIN_STAIRS_F1 ZN; CB_OFFICES_OPEN_F1 ZN; CB_SECONDARY_STAIRS_1_F1 ZN; CB_STAFF_RESTROOMS_1_F1 ZN; CB_STAFF_RESTROOMS_2_F1 ZN; CB_STORAGE_F1 ZN; CB_STUDENTS_RESTROOMS_1_F1 ZN; CB_STUDENTS_RESTROOMS_2_F1 ZN; CB_UTILITY_F1 ZN; CB_SECONDARY_STAIRS_2_F1 ZN; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 110731.597 | -999.000 | 5.613586 | 0.00470145 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.5870 | 1004.8586 | 1.2020 | VAV_1 FAN | Fan:VariableVolume | 5.613586 | 6.74767605 | 4197.9300 | 999.8980 | 18.13312482 | 12.28 | 6.67 | 5.61 | 427126.69 | 25.9248 | 25.924766 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:00:00 | Sensible | 110731.60 | 91971.63 | 1.0000 | 6.74767605 | 5.613586 | 24.37 | 17.38 | 0.00954677 | 48800.6 | 10.91 | 10.91 | 0.00850000 | 32390.3 | 4.70097023 | 6.67 | 12.28 | 5.61 | 12907.219 | 97824.38 | 33.90 | 0.01653638 | 25.12 | 0.27364142 | 4.8746 | 23.89 | 0.00918859 | 23.89 | 0.00918859 | 49.6600 | 66523.78 | 0.00 | 110874.80 | 87136.63 | 6.74767605 | 24.37 | 17.40 | 0.00954677 | 48800.6 | 11.75 | 11.31 | 0.00815228 | 32369.1 | |
| VAV_1 MAIN HTG COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_1 | CB_OFFICES_ENCLOSED_1_F1 ZN; CB_OFFICES_ENCLOSED_2_F1 ZN; CB_OFFICES_ENCLOSED_3_F1 ZN; CB_OFFICES_ENCLOSED_4_F1 ZN; CB_OFFICES_ENCLOSED_5_F1 ZN; CB_OFFICES_ENCLOSED_6_F1 ZN; CB_OFFICES_ENCLOSED_7_F1 ZN; CB_OFFICES_ENCLOSED_8_F1 ZN; CB_CAFE_STUDY_LOUNGE_F1 ZN; CB_CONFERENCE_ROOM_F1 ZN; CB_CORRIDOR_F1 ZN; CB_ENTRANCE_LOBBY_F1 ZN; CB_LECTURE_ROOM_1_F1 ZN; CB_LECTURE_ROOM_2_F1 ZN; CB_LIBRARY_MEDIA_CENTER_F1 ZN; CB_MAIN_STAIRS_F1 ZN; CB_OFFICES_OPEN_F1 ZN; CB_SECONDARY_STAIRS_1_F1 ZN; CB_STAFF_RESTROOMS_1_F1 ZN; CB_STAFF_RESTROOMS_2_F1 ZN; CB_STORAGE_F1 ZN; CB_STUDENTS_RESTROOMS_1_F1 ZN; CB_STUDENTS_RESTROOMS_2_F1 ZN; CB_UTILITY_F1 ZN; CB_SECONDARY_STAIRS_2_F1 ZN; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 1836.260 | 1836.260 | 1.684076 | 0.00004016 | 28.694 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | VAV_1 FAN | Fan:VariableVolume | 5.613586 | 6.74767605 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 1.9371 | 1.976057 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:40:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 1836.26 | 1836.26 | 1.0000 | 2.02430281 | 1.684076 | 11.88 | 9.43 | 0.00634638 | 27944.5 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 0.04016012 | 60.00 | 48.89 | 11.11 | 0.000 | 1836.26 | 4.60 | 0.00525715 | 4.59 | 0.27364142 | 16.2488 | 13.29 | 0.00655770 | 22.00 | 0.00606131 | 36.8999 | 2113.95 | 0.00 | 1960.44 | 1960.44 | 2.02430281 | 7.22 | 7.22 | 0.00634638 | 23214.3 | 8.17 | 7.72 | 0.00634638 | 24182.7 | |
| VAV_2 CLG COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_2 | CB_FACULTY_OFFICE_1_F2 ZN; CB_FACULTY_OFFICE_2_F2 ZN; CB_FACULTY_OFFICE_3_F2 ZN; CB_FACULTY_OFFICE_4_F2 ZN; CB_FACULTY_OFFICE_5_F2 ZN; CB_FACULTY_OFFICE_6_F2 ZN; CB_FACULTY_OFFICE_7_F2 ZN; CB_FACULTY_OFFICE_8_F2 ZN; CB_CLASSROOM_1_F2 ZN; CB_CLASSROOM_2_F2 ZN; CB_CLASSROOM_3_F2 ZN; CB_CLASSROOM_4_F2 ZN; CB_CLASSROOM_5_F2 ZN; CB_CLASSROOM_6_F2 ZN; CB_CLASSROOM_7_F2 ZN; CB_CLASSROOM_8_F2 ZN; CB_CONFERENCE_ROOM_F2 ZN; CB_CORRIDOR_F2 ZN; CB_STUDIO_1_F2 ZN; CB_STUDIO_2_F2 ZN; CB_MAIN_STAIRS_F2 ZN; CB_OFFICES_OPEN_F2 ZN; CB_SECONDARY_STAIRS_1_F2 ZN; CB_SECONDARY_STAIRS_2_F2 ZN; CB_FACULTY_RESTROOMS_1_F2 ZN; CB_FACULTY_RESTROOMS_2_F2 ZN; CB_STUDENTS_RESTROOMS_1_F2 ZN; CB_STUDENTS_RESTROOMS_2_F2 ZN; CB_UTILITY_F2 ZN; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 94101.465 | -999.000 | 4.794329 | 0.00399537 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.6686 | 1004.8586 | 1.2020 | VAV_2 FAN | Fan:VariableVolume | 4.794329 | 5.76290736 | 4197.9300 | 999.8980 | 18.13312482 | 12.28 | 6.67 | 5.61 | 427126.69 | 22.0313 | 22.031277 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | Sensible | 94101.46 | 77393.01 | 1.0000 | 5.76290736 | 4.794329 | 24.17 | 17.35 | 0.00959068 | 48706.9 | 10.90 | 10.90 | 0.00850000 | 32378.1 | 3.99495895 | 6.67 | 12.28 | 5.61 | 11095.096 | 83006.37 | 33.43 | 0.01653549 | 24.99 | 0.14437502 | 3.0114 | 23.89 | 0.00937505 | 23.89 | 0.00937505 | 50.6532 | 56814.35 | 0.00 | 94224.02 | 73345.75 | 5.76290736 | 24.17 | 17.37 | 0.00959068 | 48706.9 | 11.73 | 11.30 | 0.00815460 | 32356.8 | |
| VAV_2 MAIN HTG COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_2 | CB_FACULTY_OFFICE_1_F2 ZN; CB_FACULTY_OFFICE_2_F2 ZN; CB_FACULTY_OFFICE_3_F2 ZN; CB_FACULTY_OFFICE_4_F2 ZN; CB_FACULTY_OFFICE_5_F2 ZN; CB_FACULTY_OFFICE_6_F2 ZN; CB_FACULTY_OFFICE_7_F2 ZN; CB_FACULTY_OFFICE_8_F2 ZN; CB_CLASSROOM_1_F2 ZN; CB_CLASSROOM_2_F2 ZN; CB_CLASSROOM_3_F2 ZN; CB_CLASSROOM_4_F2 ZN; CB_CLASSROOM_5_F2 ZN; CB_CLASSROOM_6_F2 ZN; CB_CLASSROOM_7_F2 ZN; CB_CLASSROOM_8_F2 ZN; CB_CONFERENCE_ROOM_F2 ZN; CB_CORRIDOR_F2 ZN; CB_STUDIO_1_F2 ZN; CB_STUDIO_2_F2 ZN; CB_MAIN_STAIRS_F2 ZN; CB_OFFICES_OPEN_F2 ZN; CB_SECONDARY_STAIRS_1_F2 ZN; CB_SECONDARY_STAIRS_2_F2 ZN; CB_FACULTY_RESTROOMS_1_F2 ZN; CB_FACULTY_RESTROOMS_2_F2 ZN; CB_STUDENTS_RESTROOMS_1_F2 ZN; CB_STUDENTS_RESTROOMS_2_F2 ZN; CB_UTILITY_F2 ZN; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 4167.512 | 4167.512 | 1.438299 | 0.00009116 | 64.725 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | VAV_2 FAN | Fan:VariableVolume | 4.794329 | 5.76290736 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 4.3963 | 4.484791 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 4167.51 | 4167.51 | 1.0000 | 1.72887221 | 1.438299 | 10.38 | 8.58 | 0.00619839 | 26050.5 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 0.09114602 | 60.00 | 48.89 | 11.11 | 0.000 | 4167.51 | 4.60 | 0.00525715 | 4.59 | 0.14437502 | 10.0379 | 11.02 | 0.00630341 | 21.78 | 0.00595270 | 36.7472 | 1458.92 | 0.00 | 4356.41 | 4356.41 | 1.72887221 | 7.22 | 7.09 | 0.00619839 | 22842.2 | 9.70 | 8.28 | 0.00619839 | 25362.0 | |
| VAV_3 CLG COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_3 | CB_FACULTY_OFFICE_1_F3 ZN; CB_FACULTY_OFFICE_2_F3 ZN; CB_FACULTY_OFFICE_3_F3 ZN; CB_FACULTY_OFFICE_4_F3 ZN; CB_FACULTY_OFFICE_5_F3 ZN; CB_FACULTY_OFFICE_6_F3 ZN; CB_FACULTY_OFFICE_7_F3 ZN; CB_FACULTY_OFFICE_8_F3 ZN; CB_CLASSROOM_1_F3 ZN; CB_CLASSROOM_2_F3 ZN; CB_CLASSROOM_3_F3 ZN; CB_CLASSROOM_4_F3 ZN; CB_CLASSROOM_5_F3 ZN; CB_CLASSROOM_6_F3 ZN; CB_CLASSROOM_7_F3 ZN; CB_CLASSROOM_8_F3 ZN; CB_CONFERENCE_ROOM_F3 ZN; CB_CORRIDOR_1_F3 ZN; CB_CORRIDOR_2_F3 ZN; CB_STUDIO_1_F3 ZN; CB_STUDIO_2_F3 ZN; CB_MAIN_STAIRS_F3 ZN; CB_OFFICES_OPEN_F3 ZN; CB_SECONDARY_STAIRS_1_F3 ZN; CB_SECONDARY_STAIRS_2_F3 ZN; CB_FACULTY_RESTROOMS_1_F3 ZN; CB_FACULTY_RESTROOMS_2_F3 ZN; CB_STUDENTS_RESTROOMS_1_F3 ZN; CB_STUDENTS_RESTROOMS_2_F3 ZN; CB_UTILITY_F3 ZN; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 93505.248 | -999.000 | 4.750306 | 0.00397005 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1022.7009 | 1004.8586 | 1.2020 | VAV_3 FAN | Fan:VariableVolume | 4.750306 | 5.70999093 | 4197.9300 | 999.8980 | 18.13312482 | 12.28 | 6.67 | 5.61 | 427126.69 | 21.8917 | 21.891689 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 16:00:00 | Sensible | 93505.25 | 76688.45 | 1.0000 | 5.70999093 | 4.750306 | 24.18 | 17.37 | 0.00960807 | 48753.9 | 10.90 | 10.90 | 0.00850000 | 32378.1 | 3.96964735 | 6.67 | 12.28 | 5.61 | 10993.218 | 82512.03 | 33.43 | 0.01653549 | 24.99 | 0.14437502 | 3.0393 | 23.89 | 0.00939092 | 23.89 | 0.00939092 | 50.7378 | 56292.56 | 0.00 | 93627.16 | 72705.82 | 5.70999093 | 24.18 | 17.39 | 0.00960807 | 48753.9 | 11.73 | 11.30 | 0.00815568 | 32356.8 | |
| VAV_3 MAIN HTG COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_3 | CB_FACULTY_OFFICE_1_F3 ZN; CB_FACULTY_OFFICE_2_F3 ZN; CB_FACULTY_OFFICE_3_F3 ZN; CB_FACULTY_OFFICE_4_F3 ZN; CB_FACULTY_OFFICE_5_F3 ZN; CB_FACULTY_OFFICE_6_F3 ZN; CB_FACULTY_OFFICE_7_F3 ZN; CB_FACULTY_OFFICE_8_F3 ZN; CB_CLASSROOM_1_F3 ZN; CB_CLASSROOM_2_F3 ZN; CB_CLASSROOM_3_F3 ZN; CB_CLASSROOM_4_F3 ZN; CB_CLASSROOM_5_F3 ZN; CB_CLASSROOM_6_F3 ZN; CB_CLASSROOM_7_F3 ZN; CB_CLASSROOM_8_F3 ZN; CB_CONFERENCE_ROOM_F3 ZN; CB_CORRIDOR_1_F3 ZN; CB_CORRIDOR_2_F3 ZN; CB_STUDIO_1_F3 ZN; CB_STUDIO_2_F3 ZN; CB_MAIN_STAIRS_F3 ZN; CB_OFFICES_OPEN_F3 ZN; CB_SECONDARY_STAIRS_1_F3 ZN; CB_SECONDARY_STAIRS_2_F3 ZN; CB_FACULTY_RESTROOMS_1_F3 ZN; CB_FACULTY_RESTROOMS_2_F3 ZN; CB_STUDENTS_RESTROOMS_1_F3 ZN; CB_STUDENTS_RESTROOMS_2_F3 ZN; CB_UTILITY_F3 ZN; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 4357.775 | 4357.775 | 1.425092 | 0.00009532 | 67.644 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | VAV_3 FAN | Fan:VariableVolume | 4.750306 | 5.70999093 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 4.5970 | 4.689539 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 4357.77 | 4357.77 | 1.0000 | 1.71299728 | 1.425092 | 10.25 | 8.57 | 0.00624713 | 26038.4 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 0.09530719 | 60.00 | 48.89 | 11.11 | 0.000 | 4357.77 | 4.60 | 0.00525715 | 4.59 | 0.14437502 | 10.1309 | 10.88 | 0.00635873 | 21.53 | 0.00589641 | 36.9488 | 1695.53 | 0.00 | 4546.87 | 4546.87 | 1.71299728 | 7.22 | 7.15 | 0.00624713 | 22964.7 | 9.83 | 8.39 | 0.00624713 | 25619.1 | |
| VAV_4 CLG COIL | Coil:Cooling:Water | AirLoop | AirLoopHVAC | VAV_4 | CB_FACULTY_OFFICE_1_F4 ZN; CB_FACULTY_OFFICE_2_F4 ZN; CB_FACULTY_OFFICE_3_F4 ZN; CB_FACULTY_OFFICE_4_F4 ZN; CB_FACULTY_OFFICE_5_F4 ZN; CB_FACULTY_OFFICE_6_F4 ZN; CB_FACULTY_OFFICE_7_F4 ZN; CB_FACULTY_OFFICE_8_F4 ZN; CB_CLASSROOM_1_F4 ZN; CB_CLASSROOM_2_F4 ZN; CB_CLASSROOM_3_F4 ZN; CB_CLASSROOM_4_F4 ZN; CB_CLASSROOM_5_F4 ZN; CB_CLASSROOM_6_F4 ZN; CB_CONFERENCE_ROOM_F4 ZN; CB_CORRIDOR_F4 ZN; CB_LAB_1_F4 ZN; CB_LAB_2_F4 ZN; CB_LAB_3_F4 ZN; CB_LAB_4_F4 ZN; CB_MAIN_STAIRS_F4 ZN; CB_OFFICES_OPEN_F4 ZN; CB_SECONDARY_STAIRS_1_F4 ZN; CB_SECONDARY_STAIRS_2_F4 ZN; CB_FACULTY_RESTROOMS_1_F4 ZN; CB_FACULTY_RESTROOMS_2_F4 ZN; CB_STUDENTS_RESTROOMS_1_F4 ZN; CB_STUDENTS_RESTROOMS_2_F4 ZN; CB_UTILITY_F4 ZN; | Coincident | CoolingDesignCapacity | N/A | Yes | Yes | Yes | No | 128788.382 | -999.000 | 7.024432 | 0.00546811 | -999.000 | -999.0000 | 1.00000 | 1.00000 | 1021.9570 | 1004.8586 | 1.2020 | VAV_4 FAN | Fan:VariableVolume | 7.024432 | 8.44354981 | 4197.9300 | 999.8980 | 18.13312482 | 12.28 | 6.67 | 5.61 | 427126.69 | 30.1523 | 30.152267 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:10:00 | TAMPA-MACDILL.AFB_FL_USA ANN CLG .4% CONDNS DB=>MWB | 8/21 15:40:00 | Sensible | 128788.38 | 112876.08 | 1.0000 | 8.44354981 | 7.024432 | 24.10 | 17.01 | 0.00920791 | 47654.3 | 10.92 | 10.92 | 0.00850000 | 32401.4 | 5.46754829 | 6.67 | 12.28 | 5.61 | 16047.619 | 112740.76 | 33.58 | 0.01653578 | 25.03 | 0.15230373 | 2.1682 | 23.89 | 0.00904550 | 23.89 | 0.00904550 | 48.8963 | 83025.18 | 0.00 | 129004.34 | 106091.49 | 8.44354981 | 24.10 | 17.02 | 0.00920791 | 47654.3 | 11.80 | 11.31 | 0.00813229 | 32375.8 | |
| VAV_4 MAIN HTG COIL | Coil:Heating:Water | AirLoop | AirLoopHVAC | VAV_4 | CB_FACULTY_OFFICE_1_F4 ZN; CB_FACULTY_OFFICE_2_F4 ZN; CB_FACULTY_OFFICE_3_F4 ZN; CB_FACULTY_OFFICE_4_F4 ZN; CB_FACULTY_OFFICE_5_F4 ZN; CB_FACULTY_OFFICE_6_F4 ZN; CB_FACULTY_OFFICE_7_F4 ZN; CB_FACULTY_OFFICE_8_F4 ZN; CB_CLASSROOM_1_F4 ZN; CB_CLASSROOM_2_F4 ZN; CB_CLASSROOM_3_F4 ZN; CB_CLASSROOM_4_F4 ZN; CB_CLASSROOM_5_F4 ZN; CB_CLASSROOM_6_F4 ZN; CB_CONFERENCE_ROOM_F4 ZN; CB_CORRIDOR_F4 ZN; CB_LAB_1_F4 ZN; CB_LAB_2_F4 ZN; CB_LAB_3_F4 ZN; CB_LAB_4_F4 ZN; CB_MAIN_STAIRS_F4 ZN; CB_OFFICES_OPEN_F4 ZN; CB_SECONDARY_STAIRS_1_F4 ZN; CB_SECONDARY_STAIRS_2_F4 ZN; CB_FACULTY_RESTROOMS_1_F4 ZN; CB_FACULTY_RESTROOMS_2_F4 ZN; CB_STUDENTS_RESTROOMS_1_F4 ZN; CB_STUDENTS_RESTROOMS_2_F4 ZN; CB_UTILITY_F4 ZN; | Coincident | HeatingDesignCapacity | N/A | Yes | Yes | Yes | No | 3631.300 | 3631.300 | 2.107330 | 0.00007943 | 56.620 | -999.0000 | 1.00000 | 1.00000 | 1019.7116 | 1004.8586 | 1.2020 | VAV_4 FAN | Fan:VariableVolume | 7.024432 | 8.44354981 | 4197.9300 | 999.8980 | 2.03233598 | 71.11 | 82.22 | 11.11 | 94795.60 | 3.8307 | 3.907756 | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 05:50:00 | unknown | unknown | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB | 1/21 07:10:00 | Sensible | 3631.30 | 3631.30 | 1.0000 | 2.53306494 | 2.107330 | 11.35 | 9.26 | 0.00641471 | 27584.3 | 12.78 | 11.57 | 0.00800000 | 33037.2 | 0.07941874 | 60.00 | 48.89 | 11.11 | 0.000 | 3631.30 | 4.60 | 0.00525715 | 4.59 | 0.15230373 | 7.2273 | 11.88 | 0.00650489 | 21.21 | 0.00582201 | 37.2098 | 1747.45 | 0.00 | 3848.13 | 3848.13 | 2.53306494 | 7.22 | 7.22 | 0.00641471 | 23386.1 | 8.72 | 8.06 | 0.00641471 | 24905.3 |
Report: System Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Economizer| High Limit Shutoff Control | Minimum Outdoor Air [m3/s] | Maximum Outdoor Air [m3/s] | Return Air Temp Limit | Return Air Enthalpy Limit | Outdoor Air Temperature Limit [C] | Outdoor Air Enthalpy Limit [C] | |
| VAV_1 OA CONTROLLER | DifferentialEnthalpy | 0.00 | 5.61 | - | |||
| VAV_2 OA CONTROLLER | DifferentialEnthalpy | 0.00 | 4.79 | - | |||
| VAV_3 OA CONTROLLER | DifferentialEnthalpy | 0.00 | 4.75 | - | |||
| VAV_4 OA CONTROLLER | DifferentialEnthalpy | 0.00 | 7.02 | - |
| Controller:MechanicalVentilation Name | Outdoor Air Per Person [m3/s-person] | Outdoor Air Per Area [m3/s-m2] | Outdoor Air Per Zone [m3/s] | Outdoor Air ACH [ach] | Outdoor Air Method | Outdoor Air Schedule Name | Air Distribution Effectiveness in Cooling Mode | Air Distribution Effectiveness in Heating Mode | Air Distribution Effectiveness Schedule Name | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_1_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_1_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_2_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_2_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_3_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_3_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_3_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_4_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_4_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_4_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_5_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_5_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_5_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_6_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_6_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_6_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_7_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_7_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_8_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CLASSROOM_8_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CONFERENCE_ROOM_F1 ZN | VAV_1 VENT CONTROLLER | 0.003304 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CONFERENCE_ROOM_F2 ZN | VAV_2 VENT CONTROLLER | 0.003304 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CONFERENCE_ROOM_F3 ZN | VAV_3 VENT CONTROLLER | 0.003304 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CONFERENCE_ROOM_F4 ZN | VAV_4 VENT CONTROLLER | 0.003304 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_ENTRANCE_LOBBY_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_1_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_1_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_2_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_2_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_3_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_3_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_3_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_4_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_4_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_4_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_5_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_5_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_5_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_6_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_6_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_6_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_7_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_7_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_7_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_8_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_8_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_OFFICE_8_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LAB_1_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LAB_2_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LAB_3_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LAB_4_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LECTURE_ROOM_1_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LECTURE_ROOM_2_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_1_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_2_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_3_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_4_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_5_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_6_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_7_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_ENCLOSED_8_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_OPEN_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_OPEN_F2 ZN | VAV_2 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_OPEN_F3 ZN | VAV_3 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_OFFICES_OPEN_F4 ZN | VAV_4 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDIO_1_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDIO_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDIO_2_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDIO_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CORRIDOR_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CORRIDOR_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CORRIDOR_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CORRIDOR_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_CORRIDOR_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_RESTROOMS_1_F2 ZN | VAV_2 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_RESTROOMS_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_RESTROOMS_1_F4 ZN | VAV_4 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_RESTROOMS_2_F2 ZN | VAV_2 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_RESTROOMS_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_FACULTY_RESTROOMS_2_F4 ZN | VAV_4 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_MAIN_STAIRS_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_MAIN_STAIRS_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_MAIN_STAIRS_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_MAIN_STAIRS_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_1_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_1_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_1_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_2_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_2_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_SECONDARY_STAIRS_2_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STAFF_RESTROOMS_1_F1 ZN | VAV_1 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STAFF_RESTROOMS_2_F1 ZN | VAV_1 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STORAGE_F1 ZN | VAV_1 VENT CONTROLLER | 0.002360 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_1_F1 ZN | VAV_1 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_1_F2 ZN | VAV_2 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_1_F3 ZN | VAV_3 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_1_F4 ZN | VAV_4 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_2_F1 ZN | VAV_1 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_2_F2 ZN | VAV_2 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_2_F3 ZN | VAV_3 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_STUDENTS_RESTROOMS_2_F4 ZN | VAV_4 VENT CONTROLLER | 0.035396 | 0.000000 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_UTILITY_F1 ZN | VAV_1 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_UTILITY_F2 ZN | VAV_2 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_UTILITY_F3 ZN | VAV_3 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 | ||
| CB_UTILITY_F4 ZN | VAV_4 VENT CONTROLLER | 0.000000 | 0.000102 | 0.000000 | 0.000000 | Sum | 1.00 | 1.00 |
| Winter Clothes [hr] | Summer Clothes [hr] | Summer or Winter Clothes [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 2860.00 | 131.83 | 131.83 |
| CB_CLASSROOM_1_F2 ZN | 3379.83 | 94.17 | 94.17 |
| CB_CLASSROOM_1_F3 ZN | 3380.00 | 115.33 | 115.33 |
| CB_CLASSROOM_1_F4 ZN | 3377.17 | 93.33 | 93.33 |
| CB_CLASSROOM_2_F2 ZN | 3372.33 | 53.67 | 53.67 |
| CB_CLASSROOM_2_F3 ZN | 3372.33 | 68.50 | 68.50 |
| CB_CLASSROOM_2_F4 ZN | 3362.83 | 37.00 | 37.00 |
| CB_CLASSROOM_3_F2 ZN | 3374.17 | 50.83 | 50.83 |
| CB_CLASSROOM_3_F3 ZN | 3370.00 | 73.00 | 73.00 |
| CB_CLASSROOM_3_F4 ZN | 3354.00 | 39.17 | 39.17 |
| CB_CLASSROOM_4_F2 ZN | 3380.00 | 35.17 | 35.17 |
| CB_CLASSROOM_4_F3 ZN | 3374.33 | 74.33 | 74.33 |
| CB_CLASSROOM_4_F4 ZN | 3365.33 | 41.17 | 41.17 |
| CB_CLASSROOM_5_F2 ZN | 3356.83 | 60.67 | 60.67 |
| CB_CLASSROOM_5_F3 ZN | 3356.17 | 82.67 | 82.67 |
| CB_CLASSROOM_5_F4 ZN | 3362.83 | 37.33 | 37.33 |
| CB_CLASSROOM_6_F2 ZN | 3377.50 | 65.00 | 65.00 |
| CB_CLASSROOM_6_F3 ZN | 3369.67 | 75.67 | 75.67 |
| CB_CLASSROOM_6_F4 ZN | 3376.50 | 96.00 | 96.00 |
| CB_CLASSROOM_7_F2 ZN | 3380.00 | 64.17 | 64.17 |
| CB_CLASSROOM_7_F3 ZN | 3374.67 | 65.83 | 65.83 |
| CB_CLASSROOM_8_F2 ZN | 3380.00 | 66.17 | 66.17 |
| CB_CLASSROOM_8_F3 ZN | 3380.00 | 99.83 | 99.83 |
| CB_CONFERENCE_ROOM_F1 ZN | 1655.83 | 1207.50 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 1871.00 | 842.67 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 2009.00 | 701.67 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 1874.33 | 942.17 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 3314.67 | 52.50 | 52.50 |
| CB_FACULTY_OFFICE_1_F2 ZN | 3062.67 | 2.00 | 2.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 3119.17 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_1_F4 ZN | 3046.83 | 1.83 | 1.83 |
| CB_FACULTY_OFFICE_2_F2 ZN | 2999.00 | 2.17 | 2.17 |
| CB_FACULTY_OFFICE_2_F3 ZN | 3043.50 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_2_F4 ZN | 2889.67 | 3.00 | 3.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 2986.00 | 2.17 | 2.17 |
| CB_FACULTY_OFFICE_3_F3 ZN | 3026.33 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_3_F4 ZN | 2864.17 | 3.33 | 3.33 |
| CB_FACULTY_OFFICE_4_F2 ZN | 2982.33 | 2.17 | 2.17 |
| CB_FACULTY_OFFICE_4_F3 ZN | 3022.17 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_4_F4 ZN | 2858.33 | 3.33 | 3.33 |
| CB_FACULTY_OFFICE_5_F2 ZN | 2982.33 | 2.17 | 2.17 |
| CB_FACULTY_OFFICE_5_F3 ZN | 3022.17 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_5_F4 ZN | 2858.33 | 3.33 | 3.33 |
| CB_FACULTY_OFFICE_6_F2 ZN | 2985.17 | 2.17 | 2.17 |
| CB_FACULTY_OFFICE_6_F3 ZN | 3026.33 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_6_F4 ZN | 2864.00 | 3.33 | 3.33 |
| CB_FACULTY_OFFICE_7_F2 ZN | 2995.33 | 2.17 | 2.17 |
| CB_FACULTY_OFFICE_7_F3 ZN | 3041.17 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_7_F4 ZN | 2888.50 | 3.00 | 3.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 3054.67 | 2.00 | 2.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 3114.17 | 2.50 | 2.50 |
| CB_FACULTY_OFFICE_8_F4 ZN | 3039.00 | 1.83 | 1.83 |
| CB_LAB_1_F4 ZN | 3574.00 | 11.67 | 11.67 |
| CB_LAB_2_F4 ZN | 3573.00 | 8.83 | 8.83 |
| CB_LAB_3_F4 ZN | 3574.00 | 9.17 | 9.17 |
| CB_LAB_4_F4 ZN | 3574.00 | 13.00 | 13.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 1940.00 | 13.67 | 13.67 |
| CB_LECTURE_ROOM_2_F1 ZN | 3380.00 | 54.33 | 54.33 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 1940.00 | 0.67 | 0.67 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 3070.50 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 2976.67 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 2958.83 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 2956.17 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 2956.17 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 2957.33 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 2967.33 | 0.50 | 0.50 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 3028.33 | 0.50 | 0.50 |
| CB_OFFICES_OPEN_F1 ZN | 2948.00 | 9.17 | 9.17 |
| CB_OFFICES_OPEN_F2 ZN | 2783.00 | 8.33 | 8.33 |
| CB_OFFICES_OPEN_F3 ZN | 2845.67 | 32.00 | 32.00 |
| CB_OFFICES_OPEN_F4 ZN | 2753.50 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 3179.17 | 12.17 | 12.17 |
| CB_STUDIO_1_F3 ZN | 3182.00 | 51.50 | 51.50 |
| CB_STUDIO_2_F2 ZN | 3180.67 | 29.33 | 29.33 |
| CB_STUDIO_2_F3 ZN | 3182.00 | 18.33 | 18.33 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 |
| Facility | 3630.83 | 1549.83 | 283.50 |
| During Heating [hr] | During Cooling [hr] | During Occupied Heating [hr] | During Occupied Cooling [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 1814.17 | 0.00 | 486.83 |
| CB_CLASSROOM_1_F2 ZN | 0.00 | 487.83 | 0.00 | 342.17 |
| CB_CLASSROOM_1_F3 ZN | 0.00 | 643.17 | 0.00 | 359.00 |
| CB_CLASSROOM_1_F4 ZN | 0.00 | 293.33 | 0.00 | 77.00 |
| CB_CLASSROOM_2_F2 ZN | 0.00 | 778.33 | 0.00 | 711.83 |
| CB_CLASSROOM_2_F3 ZN | 0.00 | 979.67 | 0.00 | 756.83 |
| CB_CLASSROOM_2_F4 ZN | 0.00 | 475.83 | 0.00 | 313.67 |
| CB_CLASSROOM_3_F2 ZN | 0.00 | 767.33 | 0.00 | 717.17 |
| CB_CLASSROOM_3_F3 ZN | 0.00 | 994.83 | 0.00 | 832.17 |
| CB_CLASSROOM_3_F4 ZN | 0.00 | 469.00 | 0.00 | 335.67 |
| CB_CLASSROOM_4_F2 ZN | 0.00 | 578.33 | 0.00 | 544.67 |
| CB_CLASSROOM_4_F3 ZN | 0.00 | 960.83 | 0.00 | 885.50 |
| CB_CLASSROOM_4_F4 ZN | 0.00 | 492.67 | 0.00 | 351.33 |
| CB_CLASSROOM_5_F2 ZN | 0.00 | 914.17 | 0.00 | 891.50 |
| CB_CLASSROOM_5_F3 ZN | 0.00 | 964.50 | 0.00 | 909.67 |
| CB_CLASSROOM_5_F4 ZN | 0.00 | 479.17 | 0.00 | 318.83 |
| CB_CLASSROOM_6_F2 ZN | 0.00 | 1014.00 | 0.00 | 881.67 |
| CB_CLASSROOM_6_F3 ZN | 0.00 | 1033.00 | 0.00 | 845.50 |
| CB_CLASSROOM_6_F4 ZN | 0.00 | 428.00 | 0.00 | 205.50 |
| CB_CLASSROOM_7_F2 ZN | 0.00 | 1232.83 | 0.00 | 818.50 |
| CB_CLASSROOM_7_F3 ZN | 0.00 | 1068.83 | 0.00 | 750.50 |
| CB_CLASSROOM_8_F2 ZN | 0.00 | 741.17 | 0.00 | 216.50 |
| CB_CLASSROOM_8_F3 ZN | 0.00 | 600.00 | 0.00 | 204.33 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 126.67 | 0.00 | 126.67 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 445.50 | 0.00 | 445.50 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 602.67 | 0.00 | 602.67 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 138.17 | 0.00 | 138.17 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 1527.67 | 0.00 | 1504.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 462.17 | 0.00 | 402.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 571.00 | 0.00 | 447.17 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 278.17 | 0.00 | 101.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 419.83 | 0.00 | 352.67 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 518.17 | 0.00 | 406.17 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 235.33 | 0.00 | 85.17 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 408.33 | 0.00 | 342.17 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 506.00 | 0.00 | 396.17 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 227.17 | 0.00 | 84.17 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 405.83 | 0.00 | 340.17 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 502.67 | 0.00 | 394.33 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 226.00 | 0.00 | 84.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 405.67 | 0.00 | 340.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 502.50 | 0.00 | 394.17 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 226.00 | 0.00 | 84.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 407.50 | 0.00 | 341.33 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 505.50 | 0.00 | 395.67 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 227.17 | 0.00 | 84.17 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 414.50 | 0.00 | 348.33 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 516.33 | 0.00 | 404.33 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 234.67 | 0.00 | 85.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 436.33 | 0.00 | 376.17 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 547.50 | 0.00 | 427.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 272.67 | 0.00 | 97.67 |
| CB_LAB_1_F4 ZN | 0.00 | 1170.00 | 0.00 | 62.17 |
| CB_LAB_2_F4 ZN | 0.00 | 1279.33 | 0.00 | 245.17 |
| CB_LAB_3_F4 ZN | 0.00 | 1455.83 | 0.00 | 282.17 |
| CB_LAB_4_F4 ZN | 0.00 | 1196.17 | 0.00 | 103.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 450.50 | 0.00 | 432.17 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 632.83 | 0.00 | 617.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 371.33 | 0.00 | 339.83 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 351.33 | 0.00 | 338.17 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 307.00 | 0.00 | 294.33 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 297.17 | 0.00 | 284.67 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 294.17 | 0.00 | 282.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 293.67 | 0.00 | 281.50 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 294.33 | 0.00 | 282.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 298.83 | 0.00 | 286.50 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 322.83 | 0.00 | 311.50 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 2084.83 | 0.00 | 2064.83 |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 2093.83 | 0.00 | 2050.50 |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 2155.00 | 0.00 | 2087.17 |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 785.50 | 0.00 | 735.50 |
| CB_STUDIO_1_F2 ZN | 0.00 | 477.67 | 0.00 | 403.50 |
| CB_STUDIO_1_F3 ZN | 0.00 | 1284.33 | 0.00 | 834.83 |
| CB_STUDIO_2_F2 ZN | 0.00 | 830.67 | 0.00 | 735.50 |
| CB_STUDIO_2_F3 ZN | 0.00 | 851.17 | 0.00 | 440.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 2312.50 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 3074.50 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 688.50 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 2473.83 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 1121.83 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.17 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 1.83 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 1.83 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.67 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 1.83 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 1.83 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 1601.50 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 1907.50 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 1903.50 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 878.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 364.83 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 215.33 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 262.17 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 213.83 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 370.67 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 380.67 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 459.17 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 260.17 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 249.33 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.83 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 2.67 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 2.17 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 1.17 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 2.17 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 19.83 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 3.50 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 1.83 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 2.67 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 32.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| Facility | 0.00 | 5728.67 | 0.00 | 2275.17 |
Report: Outdoor Air Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Average Outdoor Air During Occupied Hours| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 27.68 | 48.37 | 712.31 | 0.357 | 0.013 | 0.000 | 0.000 |
| CB_CLASSROOM_1_F2 ZN | 11.18 | 39.49 | 223.63 | 0.125 | 0.032 | 0.000 | 0.000 |
| CB_CLASSROOM_1_F3 ZN | 11.18 | 39.49 | 223.63 | 0.125 | 0.038 | 0.000 | 0.000 |
| CB_CLASSROOM_1_F4 ZN | 14.91 | 52.65 | 298.18 | 0.096 | 0.036 | 0.000 | 0.000 |
| CB_CLASSROOM_2_F2 ZN | 11.18 | 39.49 | 223.63 | 0.107 | 0.014 | 0.000 | 0.000 |
| CB_CLASSROOM_2_F3 ZN | 11.18 | 39.49 | 223.63 | 0.107 | 0.017 | 0.000 | 0.000 |
| CB_CLASSROOM_2_F4 ZN | 14.91 | 52.65 | 298.18 | 0.085 | 0.019 | 0.000 | 0.000 |
| CB_CLASSROOM_3_F2 ZN | 11.18 | 39.49 | 223.63 | 0.108 | 0.014 | 0.000 | 0.000 |
| CB_CLASSROOM_3_F3 ZN | 11.18 | 39.49 | 223.63 | 0.106 | 0.017 | 0.000 | 0.000 |
| CB_CLASSROOM_3_F4 ZN | 14.91 | 52.65 | 298.18 | 0.083 | 0.019 | 0.000 | 0.000 |
| CB_CLASSROOM_4_F2 ZN | 11.18 | 39.49 | 223.63 | 0.117 | 0.014 | 0.000 | 0.000 |
| CB_CLASSROOM_4_F3 ZN | 11.18 | 39.49 | 223.63 | 0.108 | 0.017 | 0.000 | 0.000 |
| CB_CLASSROOM_4_F4 ZN | 14.91 | 52.65 | 298.18 | 0.086 | 0.019 | 0.000 | 0.000 |
| CB_CLASSROOM_5_F2 ZN | 11.18 | 39.49 | 223.63 | 0.103 | 0.014 | 0.000 | 0.000 |
| CB_CLASSROOM_5_F3 ZN | 11.18 | 39.49 | 223.63 | 0.103 | 0.017 | 0.000 | 0.000 |
| CB_CLASSROOM_5_F4 ZN | 14.91 | 52.65 | 298.18 | 0.085 | 0.019 | 0.000 | 0.000 |
| CB_CLASSROOM_6_F2 ZN | 11.18 | 39.49 | 223.63 | 0.112 | 0.014 | 0.000 | 0.000 |
| CB_CLASSROOM_6_F3 ZN | 11.18 | 39.49 | 223.63 | 0.106 | 0.017 | 0.000 | 0.000 |
| CB_CLASSROOM_6_F4 ZN | 14.91 | 52.65 | 298.18 | 0.096 | 0.036 | 0.000 | 0.000 |
| CB_CLASSROOM_7_F2 ZN | 11.18 | 39.49 | 223.63 | 0.118 | 0.014 | 0.000 | 0.000 |
| CB_CLASSROOM_7_F3 ZN | 11.18 | 39.49 | 223.63 | 0.108 | 0.017 | 0.000 | 0.000 |
| CB_CLASSROOM_8_F2 ZN | 11.18 | 39.49 | 223.63 | 0.137 | 0.032 | 0.000 | 0.000 |
| CB_CLASSROOM_8_F3 ZN | 11.18 | 39.49 | 223.63 | 0.127 | 0.038 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F1 ZN | 12.96 | 24.75 | 182.22 | 0.193 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F2 ZN | 8.64 | 16.50 | 121.48 | 0.123 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F3 ZN | 8.64 | 16.50 | 121.48 | 0.124 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F4 ZN | 8.64 | 16.50 | 121.48 | 0.103 | 0.000 | 0.000 | 0.000 |
| CB_ENTRANCE_LOBBY_F1 ZN | 4.24 | 8.10 | 298.18 | 0.091 | 0.010 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.44 | 0.66 | 48.59 | 0.107 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.44 | 0.66 | 48.59 | 0.109 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.44 | 0.66 | 48.59 | 0.090 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.44 | 0.66 | 48.59 | 0.105 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.44 | 0.66 | 48.59 | 0.107 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.44 | 0.66 | 48.59 | 0.085 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.44 | 0.66 | 48.59 | 0.105 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.44 | 0.66 | 48.59 | 0.106 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.44 | 0.66 | 48.59 | 0.084 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.44 | 0.66 | 48.59 | 0.105 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.44 | 0.66 | 48.59 | 0.106 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.44 | 0.66 | 48.59 | 0.084 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.44 | 0.66 | 48.59 | 0.105 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.44 | 0.66 | 48.59 | 0.106 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.44 | 0.66 | 48.59 | 0.084 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.44 | 0.66 | 48.59 | 0.105 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.44 | 0.66 | 48.59 | 0.106 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.44 | 0.66 | 48.59 | 0.084 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.44 | 0.66 | 48.59 | 0.105 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.44 | 0.66 | 48.59 | 0.107 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.44 | 0.66 | 48.59 | 0.085 | 0.044 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.44 | 0.66 | 48.59 | 0.106 | 0.033 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.44 | 0.66 | 48.59 | 0.109 | 0.039 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.44 | 0.66 | 48.59 | 0.090 | 0.044 | 0.000 | 0.000 |
| CB_LAB_1_F4 ZN | 6.90 | 36.38 | 535.61 | 0.135 | 0.027 | 0.000 | 0.000 |
| CB_LAB_2_F4 ZN | 6.90 | 36.38 | 535.61 | 0.123 | 0.010 | 0.000 | 0.000 |
| CB_LAB_3_F4 ZN | 6.90 | 36.37 | 535.61 | 0.125 | 0.010 | 0.000 | 0.000 |
| CB_LAB_4_F4 ZN | 6.90 | 36.37 | 535.61 | 0.136 | 0.027 | 0.000 | 0.000 |
| CB_LECTURE_ROOM_1_F1 ZN | 59.77 | 189.15 | 1071.23 | 0.163 | 0.010 | 0.000 | 0.000 |
| CB_LECTURE_ROOM_2_F1 ZN | 29.83 | 105.30 | 596.35 | 0.182 | 0.015 | 0.000 | 0.000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 9.20 | 29.10 | 1071.23 | 0.124 | 0.010 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.44 | 0.66 | 48.59 | 0.171 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.44 | 0.66 | 48.59 | 0.168 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.44 | 0.66 | 48.59 | 0.167 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.44 | 0.66 | 48.59 | 0.167 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.44 | 0.66 | 48.59 | 0.167 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.44 | 0.66 | 48.59 | 0.167 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.44 | 0.66 | 48.59 | 0.167 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.44 | 0.66 | 48.59 | 0.169 | 0.023 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F1 ZN | 7.01 | 10.45 | 769.37 | 0.103 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F2 ZN | 7.56 | 11.27 | 830.11 | 0.062 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F3 ZN | 7.56 | 11.27 | 830.11 | 0.063 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F4 ZN | 7.56 | 11.28 | 830.11 | 0.056 | 0.000 | 0.000 | 0.000 |
| CB_STUDIO_1_F2 ZN | 16.35 | 64.50 | 1187.18 | 0.081 | 0.013 | 0.000 | 0.000 |
| CB_STUDIO_1_F3 ZN | 16.35 | 64.50 | 1187.18 | 0.084 | 0.016 | 0.000 | 0.000 |
| CB_STUDIO_2_F2 ZN | 16.35 | 64.50 | 1187.18 | 0.081 | 0.013 | 0.000 | 0.000 |
| CB_STUDIO_2_F3 ZN | 16.35 | 64.50 | 1187.18 | 0.085 | 0.016 | 0.000 | 0.000 |
| CB_CORRIDOR_1_F3 ZN | 125.16 | ||||||
| CB_CORRIDOR_2_F3 ZN | 242.96 | ||||||
| CB_CORRIDOR_F1 ZN | 638.69 | ||||||
| CB_CORRIDOR_F2 ZN | 368.12 | ||||||
| CB_CORRIDOR_F4 ZN | 600.03 | ||||||
| CB_FACULTY_RESTROOMS_1_F2 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_1_F3 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_1_F4 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_2_F2 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_2_F3 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_2_F4 ZN | 39.48 | ||||||
| CB_MAIN_STAIRS_F1 ZN | 73.62 | ||||||
| CB_MAIN_STAIRS_F2 ZN | 73.62 | ||||||
| CB_MAIN_STAIRS_F3 ZN | 73.62 | ||||||
| CB_MAIN_STAIRS_F4 ZN | 73.62 | ||||||
| CB_SECONDARY_STAIRS_1_F1 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_1_F2 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_1_F3 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_1_F4 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F1 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F2 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F3 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F4 ZN | 49.70 | ||||||
| CB_STAFF_RESTROOMS_1_F1 ZN | 39.48 | ||||||
| CB_STAFF_RESTROOMS_2_F1 ZN | 39.48 | ||||||
| CB_STORAGE_F1 ZN | 298.18 | ||||||
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 75.92 | ||||||
| CB_UTILITY_F1 ZN | 32.39 | ||||||
| CB_UTILITY_F2 ZN | 32.39 | ||||||
| CB_UTILITY_F3 ZN | 32.39 | ||||||
| CB_UTILITY_F4 ZN | 32.39 |
| Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Mechanical Ventilation [ach] | Infiltration [ach] | AFN Infiltration [ach] | Simple Ventilation [ach] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 27.68 | 48.37 | 712.31 | 0.273 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_1_F2 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_1_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_1_F4 ZN | 14.91 | 52.65 | 298.18 | 0.001 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_2_F2 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_2_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_2_F4 ZN | 14.91 | 52.65 | 298.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_3_F2 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_3_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_3_F4 ZN | 14.91 | 52.65 | 298.18 | 0.001 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_4_F2 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_4_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_4_F4 ZN | 14.91 | 52.65 | 298.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_5_F2 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_5_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_5_F4 ZN | 14.91 | 52.65 | 298.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_6_F2 ZN | 11.18 | 39.49 | 223.63 | 0.003 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_6_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_6_F4 ZN | 14.91 | 52.65 | 298.18 | 0.001 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_7_F2 ZN | 11.18 | 39.49 | 223.63 | 0.004 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_7_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_8_F2 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CLASSROOM_8_F3 ZN | 11.18 | 39.49 | 223.63 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F1 ZN | 12.96 | 24.75 | 182.22 | 0.020 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F2 ZN | 8.64 | 16.50 | 121.48 | 0.013 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F3 ZN | 8.64 | 16.50 | 121.48 | 0.013 | 0.000 | 0.000 | 0.000 |
| CB_CONFERENCE_ROOM_F4 ZN | 8.64 | 16.50 | 121.48 | 0.012 | 0.000 | 0.000 | 0.000 |
| CB_ENTRANCE_LOBBY_F1 ZN | 4.24 | 8.10 | 298.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.44 | 0.66 | 48.59 | 0.010 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.44 | 0.66 | 48.59 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.44 | 0.66 | 48.59 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.44 | 0.66 | 48.59 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.44 | 0.66 | 48.59 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.44 | 0.66 | 48.59 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.44 | 0.66 | 48.59 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.44 | 0.66 | 48.59 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.44 | 0.66 | 48.59 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.44 | 0.66 | 48.59 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.44 | 0.66 | 48.59 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.44 | 0.66 | 48.59 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.44 | 0.66 | 48.59 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.44 | 0.66 | 48.59 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.44 | 0.66 | 48.59 | 0.010 | 0.000 | 0.000 | 0.000 |
| CB_LAB_1_F4 ZN | 6.90 | 36.38 | 535.61 | 0.003 | 0.000 | 0.000 | 0.000 |
| CB_LAB_2_F4 ZN | 6.90 | 36.38 | 535.61 | 0.005 | 0.000 | 0.000 | 0.000 |
| CB_LAB_3_F4 ZN | 6.90 | 36.37 | 535.61 | 0.006 | 0.000 | 0.000 | 0.000 |
| CB_LAB_4_F4 ZN | 6.90 | 36.37 | 535.61 | 0.004 | 0.000 | 0.000 | 0.000 |
| CB_LECTURE_ROOM_1_F1 ZN | 59.77 | 189.15 | 1071.23 | 0.004 | 0.000 | 0.000 | 0.000 |
| CB_LECTURE_ROOM_2_F1 ZN | 29.83 | 105.30 | 596.35 | 0.004 | 0.000 | 0.000 | 0.000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 9.20 | 29.10 | 1071.23 | 0.021 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.44 | 0.66 | 48.59 | 0.020 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.44 | 0.66 | 48.59 | 0.017 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.44 | 0.66 | 48.59 | 0.018 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.44 | 0.66 | 48.59 | 0.018 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.44 | 0.66 | 48.59 | 0.018 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.44 | 0.66 | 48.59 | 0.018 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.44 | 0.66 | 48.59 | 0.017 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.44 | 0.66 | 48.59 | 0.020 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F1 ZN | 7.01 | 10.45 | 769.37 | 0.013 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F2 ZN | 7.56 | 11.27 | 830.11 | 0.008 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F3 ZN | 7.56 | 11.27 | 830.11 | 0.009 | 0.000 | 0.000 | 0.000 |
| CB_OFFICES_OPEN_F4 ZN | 7.56 | 11.28 | 830.11 | 0.007 | 0.000 | 0.000 | 0.000 |
| CB_STUDIO_1_F2 ZN | 16.35 | 64.50 | 1187.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_STUDIO_1_F3 ZN | 16.35 | 64.50 | 1187.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_STUDIO_2_F2 ZN | 16.35 | 64.50 | 1187.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_STUDIO_2_F3 ZN | 16.35 | 64.50 | 1187.18 | 0.002 | 0.000 | 0.000 | 0.000 |
| CB_CORRIDOR_1_F3 ZN | 125.16 | ||||||
| CB_CORRIDOR_2_F3 ZN | 242.96 | ||||||
| CB_CORRIDOR_F1 ZN | 638.69 | ||||||
| CB_CORRIDOR_F2 ZN | 368.12 | ||||||
| CB_CORRIDOR_F4 ZN | 600.03 | ||||||
| CB_FACULTY_RESTROOMS_1_F2 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_1_F3 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_1_F4 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_2_F2 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_2_F3 ZN | 39.48 | ||||||
| CB_FACULTY_RESTROOMS_2_F4 ZN | 39.48 | ||||||
| CB_MAIN_STAIRS_F1 ZN | 73.62 | ||||||
| CB_MAIN_STAIRS_F2 ZN | 73.62 | ||||||
| CB_MAIN_STAIRS_F3 ZN | 73.62 | ||||||
| CB_MAIN_STAIRS_F4 ZN | 73.62 | ||||||
| CB_SECONDARY_STAIRS_1_F1 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_1_F2 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_1_F3 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_1_F4 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F1 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F2 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F3 ZN | 49.70 | ||||||
| CB_SECONDARY_STAIRS_2_F4 ZN | 49.70 | ||||||
| CB_STAFF_RESTROOMS_1_F1 ZN | 39.48 | ||||||
| CB_STAFF_RESTROOMS_2_F1 ZN | 39.48 | ||||||
| CB_STORAGE_F1 ZN | 298.18 | ||||||
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 75.92 | ||||||
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 75.92 | ||||||
| CB_UTILITY_F1 ZN | 32.39 | ||||||
| CB_UTILITY_F2 ZN | 32.39 | ||||||
| CB_UTILITY_F3 ZN | 32.39 | ||||||
| CB_UTILITY_F4 ZN | 32.39 |
Report: Outdoor Air Details
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Mechanical Ventilation Parameters by Zone| AirLoop Name | Average Number of Occupants | Nominal Number of Occupants | Zone Volume [m3] | Zone Area [m2] | Design Zone Outdoor Airflow - Voz [m3/s] | Minimum Dynamic Target Ventilation - Voz-dyn-min [m3/s] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | VAV_1 | 27.68 | 48.37 | 712.31 | 179.77 | 0.0000 | 0.000 |
| CB_CLASSROOM_1_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_1_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_1_F4 ZN | VAV_4 | 14.91 | 52.65 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_CLASSROOM_2_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_2_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_2_F4 ZN | VAV_4 | 14.91 | 52.65 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_CLASSROOM_3_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_3_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_3_F4 ZN | VAV_4 | 14.91 | 52.65 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_CLASSROOM_4_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_4_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_4_F4 ZN | VAV_4 | 14.91 | 52.65 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_CLASSROOM_5_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_5_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_5_F4 ZN | VAV_4 | 14.91 | 52.65 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_CLASSROOM_6_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_6_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_6_F4 ZN | VAV_4 | 14.91 | 52.65 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_CLASSROOM_7_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_7_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_8_F2 ZN | VAV_2 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CLASSROOM_8_F3 ZN | VAV_3 | 11.18 | 39.49 | 223.63 | 56.44 | 0.0000 | 0.000 |
| CB_CONFERENCE_ROOM_F1 ZN | VAV_1 | 12.96 | 24.75 | 182.22 | 45.99 | 0.0000 | 0.000 |
| CB_CONFERENCE_ROOM_F2 ZN | VAV_2 | 8.64 | 16.50 | 121.48 | 30.66 | 0.0000 | 0.000 |
| CB_CONFERENCE_ROOM_F3 ZN | VAV_3 | 8.64 | 16.50 | 121.48 | 30.66 | 0.0000 | 0.000 |
| CB_CONFERENCE_ROOM_F4 ZN | VAV_4 | 8.64 | 16.50 | 121.48 | 30.66 | 0.0000 | 0.000 |
| CB_ENTRANCE_LOBBY_F1 ZN | VAV_1 | 4.24 | 8.10 | 298.18 | 75.25 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_1_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_1_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_1_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_2_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_2_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_2_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_3_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_3_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_3_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_4_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_4_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_4_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_5_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_5_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_5_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_6_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_6_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_6_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_7_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_7_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_7_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_8_F2 ZN | VAV_2 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_8_F3 ZN | VAV_3 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_FACULTY_OFFICE_8_F4 ZN | VAV_4 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_LAB_1_F4 ZN | VAV_4 | 6.90 | 36.38 | 535.61 | 135.17 | 0.0000 | 0.000 |
| CB_LAB_2_F4 ZN | VAV_4 | 6.90 | 36.38 | 535.61 | 135.17 | 0.0000 | 0.000 |
| CB_LAB_3_F4 ZN | VAV_4 | 6.90 | 36.37 | 535.61 | 135.17 | 0.0000 | 0.000 |
| CB_LAB_4_F4 ZN | VAV_4 | 6.90 | 36.37 | 535.61 | 135.17 | 0.0000 | 0.000 |
| CB_LECTURE_ROOM_1_F1 ZN | VAV_1 | 59.77 | 189.15 | 1071.23 | 270.35 | 0.0000 | 0.000 |
| CB_LECTURE_ROOM_2_F1 ZN | VAV_1 | 29.83 | 105.30 | 596.35 | 150.50 | 0.0000 | 0.000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | VAV_1 | 9.20 | 29.10 | 1071.23 | 270.35 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | VAV_1 | 0.44 | 0.66 | 48.59 | 12.26 | 0.0000 | 0.000 |
| CB_OFFICES_OPEN_F1 ZN | VAV_1 | 7.01 | 10.45 | 769.37 | 194.17 | 0.0000 | 0.000 |
| CB_OFFICES_OPEN_F2 ZN | VAV_2 | 7.56 | 11.27 | 830.11 | 209.50 | 0.0000 | 0.000 |
| CB_OFFICES_OPEN_F3 ZN | VAV_3 | 7.56 | 11.27 | 830.11 | 209.50 | 0.0000 | 0.000 |
| CB_OFFICES_OPEN_F4 ZN | VAV_4 | 7.56 | 11.28 | 830.11 | 209.50 | 0.0000 | 0.000 |
| CB_STUDIO_1_F2 ZN | VAV_2 | 16.35 | 64.50 | 1187.18 | 299.61 | 0.0000 | 0.000 |
| CB_STUDIO_1_F3 ZN | VAV_3 | 16.35 | 64.50 | 1187.18 | 299.61 | 0.0000 | 0.000 |
| CB_STUDIO_2_F2 ZN | VAV_2 | 16.35 | 64.50 | 1187.18 | 299.61 | 0.0000 | 0.000 |
| CB_STUDIO_2_F3 ZN | VAV_3 | 16.35 | 64.50 | 1187.18 | 299.61 | 0.0000 | 0.000 |
| CB_CORRIDOR_1_F3 ZN | VAV_3 | 0.00 | 125.16 | 31.59 | 0.0000 | 0.003 | |
| CB_CORRIDOR_2_F3 ZN | VAV_3 | 0.00 | 242.96 | 61.32 | 0.0000 | 0.006 | |
| CB_CORRIDOR_F1 ZN | VAV_1 | 0.00 | 638.69 | 122.17 | 0.0000 | 0.012 | |
| CB_CORRIDOR_F2 ZN | VAV_2 | 0.00 | 368.12 | 92.90 | 0.0000 | 0.009 | |
| CB_CORRIDOR_F4 ZN | VAV_4 | 0.00 | 600.03 | 151.43 | 0.0000 | 0.015 | |
| CB_FACULTY_RESTROOMS_1_F2 ZN | VAV_2 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_FACULTY_RESTROOMS_1_F3 ZN | VAV_3 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_FACULTY_RESTROOMS_1_F4 ZN | VAV_4 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_FACULTY_RESTROOMS_2_F2 ZN | VAV_2 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_FACULTY_RESTROOMS_2_F3 ZN | VAV_3 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_FACULTY_RESTROOMS_2_F4 ZN | VAV_4 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_MAIN_STAIRS_F1 ZN | VAV_1 | 0.00 | 73.62 | 18.58 | 0.0000 | 0.002 | |
| CB_MAIN_STAIRS_F2 ZN | VAV_2 | 0.00 | 73.62 | 18.58 | 0.0000 | 0.002 | |
| CB_MAIN_STAIRS_F3 ZN | VAV_3 | 0.00 | 73.62 | 18.58 | 0.0000 | 0.002 | |
| CB_MAIN_STAIRS_F4 ZN | VAV_4 | 0.00 | 73.62 | 18.58 | 0.0000 | 0.002 | |
| CB_SECONDARY_STAIRS_1_F1 ZN | VAV_1 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_1_F2 ZN | VAV_2 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_1_F3 ZN | VAV_3 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_1_F4 ZN | VAV_4 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_2_F1 ZN | VAV_1 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_2_F2 ZN | VAV_2 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_2_F3 ZN | VAV_3 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_SECONDARY_STAIRS_2_F4 ZN | VAV_4 | 0.00 | 49.70 | 12.54 | 0.0000 | 0.001 | |
| CB_STAFF_RESTROOMS_1_F1 ZN | VAV_1 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_STAFF_RESTROOMS_2_F1 ZN | VAV_1 | 0.00 | 39.48 | 9.96 | 0.0000 | 0.000 | |
| CB_STORAGE_F1 ZN | VAV_1 | 0.00 | 298.18 | 75.25 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | VAV_1 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | VAV_2 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | VAV_3 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | VAV_4 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | VAV_1 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | VAV_2 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | VAV_3 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | VAV_4 | 0.00 | 75.92 | 19.16 | 0.0000 | 0.000 | |
| CB_UTILITY_F1 ZN | VAV_1 | 0.00 | 32.39 | 8.18 | 0.0000 | 0.001 | |
| CB_UTILITY_F2 ZN | VAV_2 | 0.00 | 32.39 | 8.18 | 0.0000 | 0.001 | |
| CB_UTILITY_F3 ZN | VAV_3 | 0.00 | 32.39 | 8.18 | 0.0000 | 0.001 | |
| CB_UTILITY_F4 ZN | VAV_4 | 0.00 | 32.39 | 8.18 | 0.0000 | 0.001 | |
| Total Facility | 574.87 | 1870.87 | 25386.96 | 6367.95 | 0.0000 | 0.068 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Infiltration [m3] | Total Ventilation and Infiltration [m3] | Dynamic Target Ventilation - Voz-dyn [m3] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 990951.25 | 0.00 | 990951.25 | 136048.60 | 1126999.85 | 0.00 | 0.00 | 0.00 | 3936.33 | 1065.33 |
| CB_CLASSROOM_1_F2 ZN | 101933.64 | 0.00 | 101933.64 | 111241.59 | 213175.23 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_1_F3 ZN | 102346.18 | 0.00 | 102346.18 | 131678.37 | 234024.56 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_1_F4 ZN | 104820.00 | 0.00 | 104820.00 | 169450.77 | 274270.76 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_2_F2 ZN | 87597.42 | 0.00 | 87597.42 | 50564.36 | 138161.78 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_2_F3 ZN | 87308.46 | 0.00 | 87308.46 | 59853.81 | 147162.27 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_2_F4 ZN | 91690.10 | 0.00 | 91690.10 | 89184.61 | 180874.71 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_3_F2 ZN | 88730.35 | 0.00 | 88730.35 | 50564.36 | 139294.71 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_3_F3 ZN | 86366.26 | 0.00 | 86366.26 | 59853.81 | 146220.07 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_3_F4 ZN | 89677.72 | 0.00 | 89677.72 | 89184.61 | 178862.34 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_4_F2 ZN | 98968.27 | 0.00 | 98968.27 | 50564.36 | 149532.63 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_4_F3 ZN | 88667.44 | 0.00 | 88667.44 | 59853.81 | 148521.25 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_4_F4 ZN | 92661.48 | 0.00 | 92661.48 | 89184.61 | 181846.09 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_5_F2 ZN | 86028.20 | 0.00 | 86028.20 | 50564.36 | 136592.56 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_5_F3 ZN | 84889.67 | 0.00 | 84889.67 | 59853.81 | 144743.47 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_5_F4 ZN | 91703.88 | 0.00 | 91703.88 | 89184.61 | 180888.49 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_6_F2 ZN | 94483.10 | 0.00 | 94483.10 | 50564.36 | 145047.46 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_6_F3 ZN | 88353.25 | 0.00 | 88353.25 | 59853.81 | 148207.06 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_6_F4 ZN | 104161.30 | 0.00 | 104161.30 | 169450.77 | 273612.06 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_7_F2 ZN | 99776.87 | 0.00 | 99776.87 | 50564.36 | 150341.23 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_7_F3 ZN | 88847.26 | 0.00 | 88847.26 | 59853.81 | 148701.07 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_8_F2 ZN | 112484.77 | 0.00 | 112484.77 | 111241.59 | 223726.37 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CLASSROOM_8_F3 ZN | 104462.43 | 0.00 | 104462.43 | 131678.37 | 236140.81 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_CONFERENCE_ROOM_F1 ZN | 197014.78 | 0.00 | 197014.78 | 0.00 | 197014.78 | 517164.59 | 3206.00 | 35.85 | 694.48 | 543.33 |
| CB_CONFERENCE_ROOM_F2 ZN | 106650.76 | 0.00 | 106650.76 | 0.00 | 106650.76 | 344776.40 | 3382.48 | 2.00 | 551.85 | 543.33 |
| CB_CONFERENCE_ROOM_F3 ZN | 105634.70 | 0.00 | 105634.70 | 0.00 | 105634.70 | 344776.40 | 3381.67 | 1.50 | 553.17 | 543.33 |
| CB_CONFERENCE_ROOM_F4 ZN | 70322.84 | 0.00 | 70322.84 | 0.00 | 70322.84 | 344776.40 | 3388.17 | 0.67 | 547.50 | 543.33 |
| CB_ENTRANCE_LOBBY_F1 ZN | 96967.06 | 0.00 | 96967.06 | 46913.31 | 143880.38 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_FACULTY_OFFICE_1_F2 ZN | 20418.22 | 0.00 | 20418.22 | 24720.35 | 45138.58 | 12675.71 | 1635.97 | 62.72 | 2237.64 | 543.33 |
| CB_FACULTY_OFFICE_1_F3 ZN | 20815.38 | 0.00 | 20815.38 | 29261.86 | 50077.24 | 12675.71 | 1488.00 | 166.50 | 2281.84 | 543.33 |
| CB_FACULTY_OFFICE_1_F4 ZN | 16601.75 | 0.00 | 16601.75 | 32701.03 | 49302.78 | 12675.71 | 1758.93 | 0.22 | 2177.18 | 543.33 |
| CB_FACULTY_OFFICE_2_F2 ZN | 20089.78 | 0.00 | 20089.78 | 24720.35 | 44810.14 | 12675.71 | 1652.19 | 52.89 | 2231.26 | 543.33 |
| CB_FACULTY_OFFICE_2_F3 ZN | 20304.58 | 0.00 | 20304.58 | 29261.86 | 49566.44 | 12675.71 | 1555.95 | 126.52 | 2253.86 | 543.33 |
| CB_FACULTY_OFFICE_2_F4 ZN | 15659.36 | 0.00 | 15659.36 | 32701.03 | 48360.38 | 12675.71 | 1760.30 | 0.10 | 2175.93 | 543.33 |
| CB_FACULTY_OFFICE_3_F2 ZN | 20015.32 | 0.00 | 20015.32 | 24720.35 | 44735.68 | 12675.71 | 1658.18 | 50.84 | 2227.31 | 543.33 |
| CB_FACULTY_OFFICE_3_F3 ZN | 20197.82 | 0.00 | 20197.82 | 29261.86 | 49459.68 | 12675.71 | 1573.59 | 113.66 | 2249.09 | 543.33 |
| CB_FACULTY_OFFICE_3_F4 ZN | 15516.67 | 0.00 | 15516.67 | 32701.03 | 48217.70 | 12675.71 | 1760.57 | 0.09 | 2175.67 | 543.33 |
| CB_FACULTY_OFFICE_4_F2 ZN | 19995.24 | 0.00 | 19995.24 | 24720.35 | 44715.60 | 12675.71 | 1661.48 | 49.67 | 2225.19 | 543.33 |
| CB_FACULTY_OFFICE_4_F3 ZN | 20177.97 | 0.00 | 20177.97 | 29261.86 | 49439.83 | 12675.71 | 1574.55 | 113.15 | 2248.64 | 543.33 |
| CB_FACULTY_OFFICE_4_F4 ZN | 15491.46 | 0.00 | 15491.46 | 32701.03 | 48192.49 | 12675.71 | 1760.55 | 0.14 | 2175.64 | 543.33 |
| CB_FACULTY_OFFICE_5_F2 ZN | 19993.62 | 0.00 | 19993.62 | 24720.35 | 44713.98 | 12675.71 | 1662.01 | 49.43 | 2224.89 | 543.33 |
| CB_FACULTY_OFFICE_5_F3 ZN | 20179.32 | 0.00 | 20179.32 | 29261.86 | 49441.18 | 12675.71 | 1572.23 | 115.01 | 2249.10 | 543.33 |
| CB_FACULTY_OFFICE_5_F4 ZN | 15491.97 | 0.00 | 15491.97 | 32701.03 | 48193.00 | 12675.71 | 1760.55 | 0.14 | 2175.64 | 543.33 |
| CB_FACULTY_OFFICE_6_F2 ZN | 20017.53 | 0.00 | 20017.53 | 24720.35 | 44737.88 | 12675.71 | 1657.79 | 51.09 | 2227.45 | 543.33 |
| CB_FACULTY_OFFICE_6_F3 ZN | 20198.00 | 0.00 | 20198.00 | 29261.86 | 49459.87 | 12675.71 | 1571.62 | 115.32 | 2249.40 | 543.33 |
| CB_FACULTY_OFFICE_6_F4 ZN | 15516.04 | 0.00 | 15516.04 | 32701.03 | 48217.07 | 12675.71 | 1760.57 | 0.09 | 2175.67 | 543.33 |
| CB_FACULTY_OFFICE_7_F2 ZN | 20083.26 | 0.00 | 20083.26 | 24720.35 | 44803.61 | 12675.71 | 1657.27 | 50.54 | 2228.52 | 543.33 |
| CB_FACULTY_OFFICE_7_F3 ZN | 20297.23 | 0.00 | 20297.23 | 29261.86 | 49559.09 | 12675.71 | 1561.50 | 122.13 | 2252.70 | 543.33 |
| CB_FACULTY_OFFICE_7_F4 ZN | 15653.96 | 0.00 | 15653.96 | 32701.03 | 48354.99 | 12675.71 | 1760.30 | 0.12 | 2175.91 | 543.33 |
| CB_FACULTY_OFFICE_8_F2 ZN | 20506.91 | 0.00 | 20506.91 | 24720.35 | 45227.27 | 12675.71 | 1651.52 | 55.30 | 2229.51 | 543.33 |
| CB_FACULTY_OFFICE_8_F3 ZN | 20845.55 | 0.00 | 20845.55 | 29261.86 | 50107.41 | 12675.71 | 1494.98 | 168.13 | 2273.23 | 543.33 |
| CB_FACULTY_OFFICE_8_F4 ZN | 16617.61 | 0.00 | 16617.61 | 32701.03 | 49318.63 | 12675.71 | 1758.96 | 0.45 | 2176.92 | 543.33 |
| CB_LAB_1_F4 ZN | 295724.34 | 0.00 | 295724.34 | 233366.41 | 529090.75 | 0.00 | 0.00 | 0.00 | 3936.33 | 348.33 |
| CB_LAB_2_F4 ZN | 254916.37 | 0.00 | 254916.37 | 89184.61 | 344100.98 | 0.00 | 0.00 | 0.00 | 3936.33 | 348.33 |
| CB_LAB_3_F4 ZN | 260196.77 | 0.00 | 260196.77 | 89184.61 | 349381.38 | 0.00 | 0.00 | 0.00 | 3936.33 | 348.33 |
| CB_LAB_4_F4 ZN | 295821.17 | 0.00 | 295821.17 | 233366.41 | 529187.58 | 0.00 | 0.00 | 0.00 | 3936.33 | 348.33 |
| CB_LECTURE_ROOM_1_F1 ZN | 589615.82 | 0.00 | 589615.82 | 169669.81 | 759285.62 | 0.00 | 0.00 | 0.00 | 3936.33 | 1986.33 |
| CB_LECTURE_ROOM_2_F1 ZN | 388500.28 | 0.00 | 388500.28 | 136048.60 | 524548.88 | 0.00 | 0.00 | 0.00 | 3936.33 | 543.33 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 561626.87 | 0.00 | 561626.87 | 169669.81 | 731296.68 | 152328.38 | 10.14 | 0.41 | 3925.79 | 1986.33 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 31034.90 | 0.00 | 31034.90 | 17201.55 | 48236.45 | 12675.71 | 30.94 | 5.77 | 3899.63 | 543.33 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 30396.73 | 0.00 | 30396.73 | 17201.55 | 47598.28 | 12675.71 | 41.82 | 9.52 | 3884.98 | 543.33 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 30279.92 | 0.00 | 30279.92 | 17201.55 | 47481.46 | 12675.71 | 44.23 | 8.83 | 3883.27 | 543.33 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 30258.97 | 0.00 | 30258.97 | 17201.55 | 47460.52 | 12675.71 | 44.65 | 8.70 | 3882.98 | 543.33 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 30255.10 | 0.00 | 30255.10 | 17201.55 | 47456.65 | 12675.71 | 44.65 | 8.68 | 3883.00 | 543.33 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 30263.19 | 0.00 | 30263.19 | 17201.55 | 47464.73 | 12675.71 | 44.43 | 8.67 | 3883.23 | 543.33 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 30319.31 | 0.00 | 30319.31 | 17201.55 | 47520.85 | 12675.71 | 43.90 | 8.58 | 3883.85 | 543.33 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 30589.68 | 0.00 | 30589.68 | 17201.55 | 47791.23 | 12675.71 | 39.22 | 7.50 | 3889.62 | 543.33 |
| CB_OFFICES_OPEN_F1 ZN | 305215.09 | 0.00 | 305215.09 | 0.00 | 305215.09 | 200698.71 | 1753.38 | 1.82 | 2181.13 | 543.33 |
| CB_OFFICES_OPEN_F2 ZN | 214202.35 | 0.00 | 214202.35 | 0.00 | 214202.35 | 216543.34 | 1917.12 | 37.61 | 1981.60 | 543.33 |
| CB_OFFICES_OPEN_F3 ZN | 217056.11 | 0.00 | 217056.11 | 0.00 | 217056.11 | 216543.34 | 1898.83 | 34.81 | 2002.70 | 543.33 |
| CB_OFFICES_OPEN_F4 ZN | 185286.01 | 0.00 | 185286.01 | 0.00 | 185286.01 | 216543.34 | 2126.07 | 35.48 | 1774.78 | 543.33 |
| CB_STUDIO_1_F2 ZN | 368703.75 | 0.00 | 368703.75 | 243832.58 | 612536.34 | 0.00 | 0.00 | 0.00 | 3936.33 | 741.33 |
| CB_STUDIO_1_F3 ZN | 383202.78 | 0.00 | 383202.78 | 288628.36 | 671831.14 | 0.00 | 0.00 | 0.00 | 3936.33 | 741.33 |
| CB_STUDIO_2_F2 ZN | 363859.36 | 0.00 | 363859.36 | 243832.58 | 607691.94 | 0.00 | 0.00 | 0.00 | 3936.33 | 741.33 |
| CB_STUDIO_2_F3 ZN | 386594.68 | 0.00 | 386594.68 | 288628.36 | 675223.03 | 0.00 | 0.00 | 0.00 | 3936.33 | 741.33 |
| CB_CORRIDOR_1_F3 ZN | 26735.00 | 0.00 | 26735.00 | 26601.69 | 53336.69 | 101761.23 | 8784.71 | 0.48 | 22.81 | 3936.33 |
| CB_CORRIDOR_2_F3 ZN | 41988.38 | 0.00 | 41988.38 | 0.00 | 41988.38 | 197536.51 | 8595.84 | 3.52 | 208.63 | 3936.33 |
| CB_CORRIDOR_F1 ZN | 252739.36 | 0.00 | 252739.36 | 15637.77 | 268377.13 | 393576.53 | 5245.86 | 5.99 | 3556.15 | 3936.33 |
| CB_CORRIDOR_F2 ZN | 79383.97 | 0.00 | 79383.97 | 22473.05 | 101857.02 | 299297.74 | 8782.27 | 0.38 | 25.35 | 3936.33 |
| CB_CORRIDOR_F4 ZN | 110887.99 | 0.00 | 110887.99 | 29728.20 | 140616.19 | 487855.32 | 8780.68 | 0.67 | 26.65 | 3936.33 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 153.29 | 0.00 | 153.29 | 0.00 | 153.29 | 0.00 | 0.00 | 0.00 | 3936.33 | 3150.72 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 153.28 | 0.00 | 153.28 | 0.00 | 153.28 | 0.00 | 0.00 | 0.00 | 3936.33 | 3158.77 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 141.44 | 0.00 | 141.44 | 0.00 | 141.44 | 0.00 | 0.00 | 0.00 | 3936.33 | 3287.19 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 151.78 | 0.00 | 151.78 | 0.00 | 151.78 | 0.00 | 0.00 | 0.00 | 3936.33 | 3139.60 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 159.65 | 0.00 | 159.65 | 0.00 | 159.65 | 0.00 | 0.00 | 0.00 | 3936.33 | 3220.28 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 137.63 | 0.00 | 137.63 | 0.00 | 137.63 | 0.00 | 0.00 | 0.00 | 3936.33 | 3276.55 |
| CB_MAIN_STAIRS_F1 ZN | 25368.53 | 0.00 | 25368.53 | 15637.77 | 41006.30 | 59859.55 | 7368.46 | 86.22 | 1353.32 | 3936.33 |
| CB_MAIN_STAIRS_F2 ZN | 15530.48 | 0.00 | 15530.48 | 22473.05 | 38003.53 | 59859.55 | 8785.40 | 0.18 | 22.42 | 3936.33 |
| CB_MAIN_STAIRS_F3 ZN | 15387.72 | 0.00 | 15387.72 | 26601.69 | 41989.42 | 59859.55 | 8785.80 | 0.13 | 22.07 | 3936.33 |
| CB_MAIN_STAIRS_F4 ZN | 13396.32 | 0.00 | 13396.32 | 29728.20 | 43124.52 | 59859.55 | 8785.53 | 0.07 | 22.40 | 3936.33 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 32115.01 | 0.00 | 32115.01 | 11728.33 | 43843.34 | 40405.20 | 5092.81 | 1.33 | 3713.85 | 3936.33 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 16361.68 | 0.00 | 16361.68 | 16854.79 | 33216.47 | 40405.20 | 7614.01 | 83.42 | 1110.56 | 3936.33 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 16260.97 | 0.00 | 16260.97 | 19951.27 | 36212.23 | 40405.20 | 7644.83 | 80.69 | 1082.48 | 3936.33 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 13406.96 | 0.00 | 13406.96 | 22296.15 | 35703.11 | 40405.20 | 8521.32 | 30.76 | 255.92 | 3936.33 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 23781.34 | 0.00 | 23781.34 | 11728.33 | 35509.67 | 40405.20 | 5368.48 | 23.56 | 3415.96 | 3936.33 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 15533.55 | 0.00 | 15533.55 | 16854.79 | 32388.33 | 40405.20 | 7845.60 | 76.17 | 886.22 | 3936.33 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 16101.20 | 0.00 | 16101.20 | 19951.27 | 36052.47 | 40405.20 | 7693.73 | 95.35 | 1018.92 | 3936.33 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 13447.02 | 0.00 | 13447.02 | 22296.15 | 35743.18 | 40405.20 | 8655.02 | 36.85 | 116.12 | 3936.33 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 196.93 | 0.00 | 196.93 | 0.00 | 196.93 | 0.00 | 0.00 | 0.00 | 3936.33 | 3531.28 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 219.52 | 0.00 | 219.52 | 0.00 | 219.52 | 0.00 | 0.00 | 0.00 | 3936.33 | 3569.16 |
| CB_STORAGE_F1 ZN | 213375.32 | 0.00 | 213375.32 | 46913.31 | 260288.63 | 0.00 | 0.00 | 0.00 | 3936.33 | 3936.33 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 385.00 | 0.00 | 385.00 | 0.00 | 385.00 | 0.00 | 0.00 | 0.00 | 3936.33 | 3652.63 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 280.30 | 0.00 | 280.30 | 0.00 | 280.30 | 0.00 | 0.00 | 0.00 | 3936.33 | 3554.68 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 364.45 | 0.00 | 364.45 | 0.00 | 364.45 | 0.00 | 0.00 | 0.00 | 3936.33 | 3595.76 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 302.39 | 0.00 | 302.39 | 0.00 | 302.39 | 0.00 | 0.00 | 0.00 | 3936.33 | 3615.67 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 428.32 | 0.00 | 428.32 | 0.00 | 428.32 | 0.00 | 0.00 | 0.00 | 3936.33 | 3673.68 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 313.32 | 0.00 | 313.32 | 0.00 | 313.32 | 0.00 | 0.00 | 0.00 | 3936.33 | 3581.12 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 377.33 | 0.00 | 377.33 | 0.00 | 377.33 | 0.00 | 0.00 | 0.00 | 3936.33 | 3617.50 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 327.96 | 0.00 | 327.96 | 0.00 | 327.96 | 0.00 | 0.00 | 0.00 | 3936.33 | 3632.18 |
| CB_UTILITY_F1 ZN | 11040.37 | 0.00 | 11040.37 | 0.00 | 11040.37 | 26338.20 | 7168.94 | 41.34 | 1597.72 | 3936.33 |
| CB_UTILITY_F2 ZN | 1852.21 | 0.00 | 1852.21 | 0.00 | 1852.21 | 26338.20 | 8779.52 | 1.17 | 27.31 | 3936.33 |
| CB_UTILITY_F3 ZN | 1547.73 | 0.00 | 1547.73 | 0.00 | 1547.73 | 26338.20 | 8786.98 | 0.00 | 21.02 | 3936.33 |
| CB_UTILITY_F4 ZN | 1026.92 | 0.00 | 1026.92 | 0.00 | 1026.92 | 26338.20 | 8787.00 | 0.00 | 21.00 | 3936.33 |
| Total Facility | 10369464.15 | 0.00 | 10369464.15 | 5420897.10 | 15790361.25 | 5107833.44 | 8787.22 | 824.14 | 3936.33 | 3936.33 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Infiltration [m3/s] | Total Ventilation and Infiltration [m3/s] | Dynamic Target Ventilation - Voz-dyn [m3/s] | Time Below Voz-dyn [hr] | Time At Voz-dyn [hr] | Time Above Voz-dyn [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.0687 | 0.0000 | 0.0687 | 0.0026 | 0.0712 | 0.0000 | 0.00 | 0.00 | 2871.00 |
| CB_CLASSROOM_1_F2 ZN | 0.0075 | 0.0000 | 0.0075 | 0.0019 | 0.0094 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_1_F3 ZN | 0.0075 | 0.0000 | 0.0075 | 0.0023 | 0.0098 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_1_F4 ZN | 0.0077 | 0.0000 | 0.0077 | 0.0029 | 0.0107 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_2_F2 ZN | 0.0065 | 0.0000 | 0.0065 | 0.0009 | 0.0073 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_2_F3 ZN | 0.0065 | 0.0000 | 0.0065 | 0.0010 | 0.0075 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_2_F4 ZN | 0.0068 | 0.0000 | 0.0068 | 0.0015 | 0.0084 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_3_F2 ZN | 0.0065 | 0.0000 | 0.0065 | 0.0009 | 0.0073 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_3_F3 ZN | 0.0064 | 0.0000 | 0.0064 | 0.0010 | 0.0074 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_3_F4 ZN | 0.0067 | 0.0000 | 0.0067 | 0.0015 | 0.0082 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_4_F2 ZN | 0.0071 | 0.0000 | 0.0071 | 0.0009 | 0.0079 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_4_F3 ZN | 0.0065 | 0.0000 | 0.0065 | 0.0010 | 0.0075 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_4_F4 ZN | 0.0069 | 0.0000 | 0.0069 | 0.0015 | 0.0084 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_5_F2 ZN | 0.0062 | 0.0000 | 0.0062 | 0.0009 | 0.0070 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_5_F3 ZN | 0.0062 | 0.0000 | 0.0062 | 0.0010 | 0.0072 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_5_F4 ZN | 0.0068 | 0.0000 | 0.0068 | 0.0015 | 0.0084 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_6_F2 ZN | 0.0067 | 0.0000 | 0.0067 | 0.0009 | 0.0076 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_6_F3 ZN | 0.0064 | 0.0000 | 0.0064 | 0.0010 | 0.0074 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_6_F4 ZN | 0.0077 | 0.0000 | 0.0077 | 0.0029 | 0.0106 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_7_F2 ZN | 0.0071 | 0.0000 | 0.0071 | 0.0009 | 0.0080 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_7_F3 ZN | 0.0065 | 0.0000 | 0.0065 | 0.0010 | 0.0076 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_8_F2 ZN | 0.0082 | 0.0000 | 0.0082 | 0.0019 | 0.0102 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CLASSROOM_8_F3 ZN | 0.0077 | 0.0000 | 0.0077 | 0.0023 | 0.0099 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.0095 | 0.0000 | 0.0095 | 0.0000 | 0.0095 | 0.0423 | 3206.00 | 35.85 | 151.14 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.0040 | 0.0000 | 0.0040 | 0.0000 | 0.0040 | 0.0282 | 3382.48 | 2.00 | 8.52 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.0041 | 0.0000 | 0.0041 | 0.0000 | 0.0041 | 0.0282 | 3381.67 | 1.50 | 9.83 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.0034 | 0.0000 | 0.0034 | 0.0000 | 0.0034 | 0.0282 | 3388.17 | 0.67 | 4.17 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.0073 | 0.0000 | 0.0073 | 0.0008 | 0.0082 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1635.97 | 62.72 | 1694.31 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1488.00 | 166.50 | 1738.50 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.0012 | 0.0000 | 0.0012 | 0.0006 | 0.0018 | 0.0010 | 1758.93 | 0.22 | 1633.85 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1652.19 | 52.89 | 1687.93 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1555.95 | 126.52 | 1710.53 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.0011 | 0.0000 | 0.0011 | 0.0006 | 0.0017 | 0.0010 | 1760.30 | 0.10 | 1632.60 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1658.18 | 50.84 | 1683.98 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1573.59 | 113.66 | 1705.75 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.0011 | 0.0000 | 0.0011 | 0.0006 | 0.0017 | 0.0010 | 1760.57 | 0.09 | 1632.34 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1661.48 | 49.67 | 1681.85 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1574.55 | 113.15 | 1705.30 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.0011 | 0.0000 | 0.0011 | 0.0006 | 0.0017 | 0.0010 | 1760.55 | 0.14 | 1632.31 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1662.01 | 49.43 | 1681.56 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1572.23 | 115.01 | 1705.76 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.0011 | 0.0000 | 0.0011 | 0.0006 | 0.0017 | 0.0010 | 1760.55 | 0.14 | 1632.31 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1657.79 | 51.09 | 1684.12 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1571.62 | 115.32 | 1706.06 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.0011 | 0.0000 | 0.0011 | 0.0006 | 0.0017 | 0.0010 | 1760.57 | 0.09 | 1632.34 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1657.27 | 50.54 | 1685.19 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1561.50 | 122.13 | 1709.37 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.0011 | 0.0000 | 0.0011 | 0.0006 | 0.0017 | 0.0010 | 1760.30 | 0.12 | 1632.58 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0004 | 0.0018 | 0.0010 | 1651.52 | 55.30 | 1686.18 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.0014 | 0.0000 | 0.0014 | 0.0005 | 0.0019 | 0.0010 | 1494.98 | 168.13 | 1729.89 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.0012 | 0.0000 | 0.0012 | 0.0006 | 0.0018 | 0.0010 | 1758.96 | 0.45 | 1633.59 |
| CB_LAB_1_F4 ZN | 0.0195 | 0.0000 | 0.0195 | 0.0040 | 0.0235 | 0.0000 | 0.00 | 0.00 | 3588.00 |
| CB_LAB_2_F4 ZN | 0.0177 | 0.0000 | 0.0177 | 0.0015 | 0.0192 | 0.0000 | 0.00 | 0.00 | 3588.00 |
| CB_LAB_3_F4 ZN | 0.0180 | 0.0000 | 0.0180 | 0.0015 | 0.0196 | 0.0000 | 0.00 | 0.00 | 3588.00 |
| CB_LAB_4_F4 ZN | 0.0196 | 0.0000 | 0.0196 | 0.0040 | 0.0236 | 0.0000 | 0.00 | 0.00 | 3588.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.0472 | 0.0000 | 0.0472 | 0.0028 | 0.0500 | 0.0000 | 0.00 | 0.00 | 1950.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.0292 | 0.0000 | 0.0292 | 0.0023 | 0.0315 | 0.0000 | 0.00 | 0.00 | 3393.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.0359 | 0.0000 | 0.0359 | 0.0028 | 0.0387 | 0.0217 | 10.14 | 0.41 | 1939.45 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 30.94 | 5.77 | 3356.29 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 41.82 | 9.52 | 3341.65 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 44.23 | 8.83 | 3339.93 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 44.65 | 8.70 | 3339.65 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 44.65 | 8.68 | 3339.67 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 44.43 | 8.67 | 3339.90 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 43.90 | 8.58 | 3340.52 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.0022 | 0.0000 | 0.0022 | 0.0003 | 0.0025 | 0.0010 | 39.22 | 7.50 | 3346.28 |
| CB_OFFICES_OPEN_F1 ZN | 0.0213 | 0.0000 | 0.0213 | 0.0000 | 0.0213 | 0.0164 | 1753.38 | 1.82 | 1637.80 |
| CB_OFFICES_OPEN_F2 ZN | 0.0139 | 0.0000 | 0.0139 | 0.0000 | 0.0139 | 0.0177 | 1917.12 | 37.61 | 1438.27 |
| CB_OFFICES_OPEN_F3 ZN | 0.0141 | 0.0000 | 0.0141 | 0.0000 | 0.0141 | 0.0177 | 1898.83 | 34.81 | 1459.37 |
| CB_OFFICES_OPEN_F4 ZN | 0.0126 | 0.0000 | 0.0126 | 0.0000 | 0.0126 | 0.0177 | 2126.07 | 35.48 | 1231.44 |
| CB_STUDIO_1_F2 ZN | 0.0260 | 0.0000 | 0.0260 | 0.0043 | 0.0303 | 0.0000 | 0.00 | 0.00 | 3195.00 |
| CB_STUDIO_1_F3 ZN | 0.0270 | 0.0000 | 0.0270 | 0.0051 | 0.0321 | 0.0000 | 0.00 | 0.00 | 3195.00 |
| CB_STUDIO_2_F2 ZN | 0.0258 | 0.0000 | 0.0258 | 0.0043 | 0.0301 | 0.0000 | 0.00 | 0.00 | 3195.00 |
| CB_STUDIO_2_F3 ZN | 0.0272 | 0.0000 | 0.0272 | 0.0051 | 0.0323 | 0.0000 | 0.00 | 0.00 | 3195.00 |
| Total Facility | 0.6530 | 0.0000 | 0.6530 | 0.0875 | 0.7405 | 0.2515 | 3654.00 | 715.90 | 3654.00 |
| Mechanical Ventilation [m3] | Natural Ventilation [m3] | Total Ventilation [m3] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | Time Above Zero When Unoccupied [hr] | |
| VAV_1 | 5682572.93 | 0.00 | 5682572.93 | 1532182.02 | 4871.67 | 0.00 | 3936.33 | 282.33 |
| VAV_2 | 3054592.62 | 0.00 | 3054592.62 | 1129031.28 | 4871.67 | 0.00 | 3936.33 | 282.33 |
| VAV_3 | 3042632.82 | 0.00 | 3042632.82 | 1129031.28 | 4871.67 | 0.00 | 3936.33 | 282.33 |
| VAV_4 | 3202722.06 | 0.00 | 3202722.06 | 1317588.86 | 4871.67 | 0.00 | 3936.33 | 282.33 |
| Mechanical Ventilation [m3/s] | Natural Ventilation [m3/s] | Total Ventilation [m3/s] | Sum Zone Dynamic Target Ventilation - Voz-sum-dyn [m3/s] | Time Below Voz-sum-dyn [hr] | Time At Voz-sum-dyn [hr] | Time Above Voz-sum-dyn [hr] | |
| VAV_1 | 0.3954 | 0.0000 | 0.3954 | 0.0915 | 0.00 | 0.00 | 3654.00 |
| VAV_2 | 0.2086 | 0.0000 | 0.2086 | 0.0651 | 0.00 | 0.00 | 3654.00 |
| VAV_3 | 0.2086 | 0.0000 | 0.2086 | 0.0651 | 0.00 | 0.00 | 3654.00 |
| VAV_4 | 0.2201 | 0.0000 | 0.2201 | 0.0710 | 0.00 | 0.00 | 3654.00 |
| No Limiting Factor [hr] | Limits and Scheduled Limits [hr] | Economizer [hr] | Exhaust Flow [hr] | Mixed Air Flow [hr] | High Humidity [hr] | Demand Controlled Ventilation [hr] | Night Ventilation [hr] | Demand Limiting [hr] | Energy Management System [hr] | |
| VAV_1 | 0.00 | 0.00 | 21.33 | 0.00 | 0.00 | 0.00 | 3915.00 | 0.00 | 0.00 | 0.00 |
| VAV_2 | 0.00 | 0.00 | 21.33 | 0.00 | 0.00 | 0.00 | 3915.00 | 0.00 | 0.00 | 0.00 |
| VAV_3 | 0.00 | 0.00 | 21.33 | 0.00 | 0.00 | 0.00 | 3915.00 | 0.00 | 0.00 | 0.00 |
| VAV_4 | 0.00 | 0.00 | 21.33 | 0.00 | 0.00 | 0.00 | 3915.00 | 0.00 | 0.00 | 0.00 |
| No Limiting Factor [m3/s] | Limits and Scheduled Limits [m3/s] | Economizer [m3/s] | Exhaust Flow [m3/s] | Mixed Air Flow [m3/s] | High Humidity [m3/s] | Demand Controlled Ventilation [m3/s] | Night Ventilation [m3/s] | Demand Limiting [m3/s] | Energy Management System [m3/s] | |
| VAV_1 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.3954 | 0.0000 | 0.0000 | 0.0000 |
| VAV_2 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.2086 | 0.0000 | 0.0000 | 0.0000 |
| VAV_3 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.2086 | 0.0000 | 0.0000 | 0.0000 |
| VAV_4 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.2201 | 0.0000 | 0.0000 | 0.0000 |
Report: Object Count Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Surfaces by Class| Total | Outdoors | |
| Wall | 656 | 104 |
| Floor | 135 | 26 |
| Roof | 141 | 32 |
| Internal Mass | 113 | 0 |
| Building Detached Shading | 0 | 0 |
| Fixed Detached Shading | 0 | 0 |
| Window | 104 | 104 |
| Door | 0 | 0 |
| Glass Door | 0 | 0 |
| Shading | 0 | 0 |
| Overhang | 0 | 0 |
| Fin | 0 | 0 |
| Tubular Daylighting Device Dome | 0 | 0 |
| Tubular Daylighting Device Diffuser | 0 | 0 |
| Count | |
| HVAC Air Loops | 4 |
| Conditioned Zones | 113 |
| Unconditioned Zones | 4 |
| Supply Plenums | 0 |
| Return Plenums | 0 |
| Count | |
| IDF Objects | 4206 |
| Defaulted Fields | 4255 |
| Fields with Defaults | 13081 |
| Autosized Fields | 1003 |
| Autosizable Fields | 1364 |
| Autocalculated Fields | 2787 |
| Autocalculatable Fields | 2787 |
Report: Energy Meters
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Annual and Peak Values - Electricity| Electricity Annual Value [GJ] | Electricity Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Electricity Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| Electricity:Facility | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| Electricity:Building | 2220.60 | 35156.43 | 30-JUN-23:10 | 141926.37 | 02-JAN-08:10 |
| Electricity:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 245.22 | 4352.99 | 30-JUN-23:10 | 14862.73 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - LOUNGE | 245.22 | 4352.99 | 30-JUN-23:10 | 14862.73 | 02-JAN-08:10 |
| InteriorLights:Electricity | 701.37 | 8836.70 | 01-JAN-00:10 | 44856.37 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 16.07 | 202.41 | 01-JAN-00:10 | 1027.49 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - LOUNGE | 16.07 | 202.41 | 01-JAN-00:10 | 1027.49 | 02-JAN-07:10 |
| General:InteriorLights:Electricity | 701.37 | 8836.70 | 01-JAN-00:10 | 44856.37 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 16.07 | 202.41 | 01-JAN-00:10 | 1027.49 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - LOUNGE | 16.07 | 202.41 | 01-JAN-00:10 | 1027.49 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_1_F4 ZN | 20.56 | 327.71 | 30-JUN-23:10 | 1270.08 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - CLASSROOM | 411.13 | 6554.24 | 30-JUN-23:10 | 25401.60 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_1_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - CLASSROOM | 161.86 | 2039.30 | 01-JAN-00:10 | 10351.80 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_1_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - CLASSROOM | 161.86 | 2039.30 | 01-JAN-00:10 | 10351.80 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_2_F4 ZN | 20.56 | 327.71 | 30-JUN-23:10 | 1270.08 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_2_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_2_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_3_F4 ZN | 20.56 | 327.71 | 30-JUN-23:10 | 1270.08 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_3_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_3_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_5_F4 ZN | 20.56 | 327.71 | 30-JUN-23:10 | 1270.08 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_5_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_5_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_6_F4 ZN | 20.56 | 327.71 | 30-JUN-23:10 | 1270.08 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_6_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_6_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_7_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_7_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_7_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_6_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_6_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_6_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_5_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_5_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_5_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_4_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_4_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_4_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_3_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_3_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_3_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_5_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_5_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_5_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_1_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_1_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_1_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_2_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_2_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_2_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_8_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_8_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_8_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_6_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_6_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_6_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_7_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_7_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_7_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_8_F3 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_8_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_8_F3 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_4_F4 ZN | 20.56 | 327.71 | 30-JUN-23:10 | 1270.08 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_4_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_4_F4 ZN | 8.09 | 101.97 | 01-JAN-00:10 | 517.59 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_4_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_4_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_4_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_LECTURE_ROOM_2_F1 ZN | 41.11 | 655.42 | 30-JUN-23:10 | 2540.16 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LECTURE_ROOM_2_F1 ZN | 16.19 | 203.93 | 01-JAN-00:10 | 1035.18 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LECTURE_ROOM_2_F1 ZN | 16.19 | 203.93 | 01-JAN-00:10 | 1035.18 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_2_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_2_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_2_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_1_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_1_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_1_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CLASSROOM_3_F2 ZN | 15.42 | 245.78 | 30-JUN-23:10 | 952.56 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CLASSROOM_3_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CLASSROOM_3_F2 ZN | 6.07 | 76.47 | 01-JAN-00:10 | 388.19 | 02-JAN-07:10 |
| Electricity:Zone:CB_CONFERENCE_ROOM_F4 ZN | 9.97 | 155.75 | 30-JUN-23:10 | 618.09 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - CONFERENCE | 44.87 | 700.89 | 30-JUN-23:10 | 2781.40 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F4 ZN | 4.50 | 56.75 | 01-JAN-00:10 | 288.09 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - CONFERENCE | 20.27 | 255.39 | 01-JAN-00:10 | 1296.40 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F4 ZN | 4.50 | 56.75 | 01-JAN-00:10 | 288.09 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - CONFERENCE | 20.27 | 255.39 | 01-JAN-00:10 | 1296.40 | 02-JAN-07:10 |
| Electricity:Zone:CB_CONFERENCE_ROOM_F3 ZN | 9.97 | 155.75 | 30-JUN-23:10 | 618.09 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F3 ZN | 4.50 | 56.75 | 01-JAN-00:10 | 288.09 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F3 ZN | 4.50 | 56.75 | 01-JAN-00:10 | 288.09 | 02-JAN-07:10 |
| Electricity:Zone:CB_CONFERENCE_ROOM_F1 ZN | 14.96 | 233.63 | 30-JUN-23:10 | 927.13 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F1 ZN | 6.76 | 85.13 | 01-JAN-00:10 | 432.13 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F1 ZN | 6.76 | 85.13 | 01-JAN-00:10 | 432.13 | 02-JAN-07:10 |
| Electricity:Zone:CB_CONFERENCE_ROOM_F2 ZN | 9.97 | 155.75 | 30-JUN-23:10 | 618.09 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F2 ZN | 4.50 | 56.75 | 01-JAN-00:10 | 288.09 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CONFERENCE_ROOM_F2 ZN | 4.50 | 56.75 | 01-JAN-00:10 | 288.09 | 02-JAN-07:10 |
| Electricity:Zone:CB_CORRIDOR_F1 ZN | 15.65 | 241.56 | 30-JUN-23:10 | 971.78 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - CORRIDOR | 58.84 | 908.36 | 30-JUN-23:10 | 3654.36 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CORRIDOR_F1 ZN | 7.59 | 95.59 | 01-JAN-00:10 | 485.23 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - CORRIDOR | 28.53 | 359.47 | 01-JAN-00:10 | 1824.71 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CORRIDOR_F1 ZN | 7.59 | 95.59 | 01-JAN-00:10 | 485.23 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - CORRIDOR | 28.53 | 359.47 | 01-JAN-00:10 | 1824.71 | 02-JAN-07:10 |
| Electricity:Zone:CB_CORRIDOR_F4 ZN | 19.39 | 299.42 | 30-JUN-23:10 | 1204.57 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CORRIDOR_F4 ZN | 9.40 | 118.49 | 01-JAN-00:10 | 601.47 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CORRIDOR_F4 ZN | 9.40 | 118.49 | 01-JAN-00:10 | 601.47 | 02-JAN-07:10 |
| Electricity:Zone:CB_CORRIDOR_F2 ZN | 11.90 | 183.69 | 30-JUN-23:10 | 739.00 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CORRIDOR_F2 ZN | 5.77 | 72.69 | 01-JAN-00:10 | 369.00 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CORRIDOR_F2 ZN | 5.77 | 72.69 | 01-JAN-00:10 | 369.00 | 02-JAN-07:10 |
| Electricity:Zone:CB_CORRIDOR_2_F3 ZN | 7.85 | 121.24 | 30-JUN-23:10 | 487.74 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CORRIDOR_2_F3 ZN | 3.81 | 47.98 | 01-JAN-00:10 | 243.54 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CORRIDOR_2_F3 ZN | 3.81 | 47.98 | 01-JAN-00:10 | 243.54 | 02-JAN-07:10 |
| Electricity:Zone:CB_CORRIDOR_1_F3 ZN | 4.05 | 62.46 | 30-JUN-23:10 | 251.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_CORRIDOR_1_F3 ZN | 1.96 | 24.72 | 01-JAN-00:10 | 125.46 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_CORRIDOR_1_F3 ZN | 1.96 | 24.72 | 01-JAN-00:10 | 125.46 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - OFFICE | 352.82 | 5639.69 | 30-JUN-23:10 | 21789.61 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - OFFICE | 136.20 | 1715.99 | 01-JAN-00:10 | 8710.61 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - OFFICE | 136.20 | 1715.99 | 01-JAN-00:10 | 8710.61 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_OPEN_F4 ZN | 60.83 | 972.36 | 30-JUN-23:10 | 3756.83 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F4 ZN | 23.48 | 295.86 | 01-JAN-00:10 | 1501.83 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F4 ZN | 23.48 | 295.86 | 01-JAN-00:10 | 1501.83 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_OPEN_F1 ZN | 56.38 | 901.21 | 30-JUN-23:10 | 3481.94 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F1 ZN | 21.76 | 274.21 | 01-JAN-00:10 | 1391.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F1 ZN | 21.76 | 274.21 | 01-JAN-00:10 | 1391.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_OPEN_F3 ZN | 60.83 | 972.36 | 30-JUN-23:10 | 3756.83 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F3 ZN | 23.48 | 295.86 | 01-JAN-00:10 | 1501.83 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F3 ZN | 23.48 | 295.86 | 01-JAN-00:10 | 1501.83 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_OFFICES_OPEN_F2 ZN | 60.83 | 972.36 | 30-JUN-23:10 | 3756.83 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F2 ZN | 23.48 | 295.86 | 01-JAN-00:10 | 1501.83 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_OFFICES_OPEN_F2 ZN | 23.48 | 295.86 | 01-JAN-00:10 | 1501.83 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 3.56 | 56.92 | 30-JUN-23:10 | 219.91 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 1.37 | 17.32 | 01-JAN-00:10 | 87.91 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - RESTROOM | 37.60 | 558.53 | 30-JUN-23:10 | 2350.00 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - RESTROOM | 22.23 | 280.14 | 01-JAN-00:10 | 1422.04 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - RESTROOM | 22.23 | 280.14 | 01-JAN-00:10 | 1422.04 | 02-JAN-07:10 |
| Electricity:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 1.61 | 23.88 | 30-JUN-23:10 | 100.49 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.95 | 11.98 | 01-JAN-00:10 | 60.81 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 3.09 | 45.93 | 30-JUN-23:10 | 193.26 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.83 | 23.04 | 01-JAN-00:10 | 116.94 | 02-JAN-07:10 |
| Electricity:Zone:CB_LAB_3_F4 ZN | 123.63 | 2089.10 | 30-JUN-23:10 | 7561.63 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - LABORATORY | 494.51 | 8356.41 | 30-JUN-23:10 | 30246.54 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LAB_3_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - LABORATORY | 108.93 | 1372.41 | 01-JAN-00:10 | 6966.54 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LAB_3_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - LABORATORY | 108.93 | 1372.41 | 01-JAN-00:10 | 6966.54 | 02-JAN-07:10 |
| Electricity:Zone:CB_LAB_4_F4 ZN | 123.63 | 2089.10 | 30-JUN-23:10 | 7561.63 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LAB_4_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LAB_4_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| Electricity:Zone:CB_LAB_1_F4 ZN | 123.63 | 2089.10 | 30-JUN-23:10 | 7561.64 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LAB_1_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LAB_1_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| Electricity:Zone:CB_LAB_2_F4 ZN | 123.63 | 2089.10 | 30-JUN-23:10 | 7561.64 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LAB_2_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LAB_2_F4 ZN | 27.23 | 343.10 | 01-JAN-00:10 | 1741.63 | 02-JAN-07:10 |
| Electricity:Zone:CB_LECTURE_ROOM_1_F1 ZN | 69.76 | 1125.74 | 30-JUN-23:10 | 4300.98 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - LECTURE HALL | 69.76 | 1125.74 | 30-JUN-23:10 | 4300.98 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LECTURE_ROOM_1_F1 ZN | 24.98 | 314.73 | 01-JAN-00:10 | 1597.59 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - LECTURE HALL | 24.98 | 314.73 | 01-JAN-00:10 | 1597.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LECTURE_ROOM_1_F1 ZN | 24.98 | 314.73 | 01-JAN-00:10 | 1597.59 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - LECTURE HALL | 24.98 | 314.73 | 01-JAN-00:10 | 1597.59 | 02-JAN-07:10 |
| Electricity:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 78.81 | 1240.12 | 30-JUN-23:10 | 4880.07 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - MEDIA CENTER | 78.81 | 1240.12 | 30-JUN-23:10 | 4880.07 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 33.99 | 428.23 | 01-JAN-00:10 | 2173.77 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - MEDIA CENTER | 33.99 | 428.23 | 01-JAN-00:10 | 2173.77 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 33.99 | 428.23 | 01-JAN-00:10 | 2173.77 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - MEDIA CENTER | 33.99 | 428.23 | 01-JAN-00:10 | 2173.77 | 02-JAN-07:10 |
| Electricity:Zone:CB_MAIN_STAIRS_F4 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| Electricity:SpaceType:COLLEGE - STAIRS | 12.96 | 163.33 | 01-JAN-00:10 | 829.08 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F4 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - STAIRS | 12.96 | 163.33 | 01-JAN-00:10 | 829.08 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F4 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - STAIRS | 12.96 | 163.33 | 01-JAN-00:10 | 829.08 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| Electricity:Zone:CB_MAIN_STAIRS_F3 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F3 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F3 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| Electricity:Zone:CB_MAIN_STAIRS_F2 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F2 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F2 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.54 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.54 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.54 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.54 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.54 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.54 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| Electricity:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 0.93 | 11.73 | 01-JAN-00:10 | 59.53 | 02-JAN-07:10 |
| Electricity:Zone:CB_MAIN_STAIRS_F1 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F1 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_MAIN_STAIRS_F1 ZN | 1.38 | 17.38 | 01-JAN-00:10 | 88.20 | 02-JAN-07:10 |
| Electricity:Zone:CB_STORAGE_F1 ZN | 4.33 | 54.57 | 01-JAN-00:10 | 277.02 | 02-JAN-07:10 |
| Electricity:SpaceType:COLLEGE - STORAGE | 4.33 | 54.57 | 01-JAN-00:10 | 277.02 | 02-JAN-07:10 |
| InteriorLights:Electricity:Zone:CB_STORAGE_F1 ZN | 4.33 | 54.57 | 01-JAN-00:10 | 277.02 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - STORAGE | 4.33 | 54.57 | 01-JAN-00:10 | 277.02 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STORAGE_F1 ZN | 4.33 | 54.57 | 01-JAN-00:10 | 277.02 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - STORAGE | 4.33 | 54.57 | 01-JAN-00:10 | 277.02 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDIO_1_F2 ZN | 81.84 | 1304.78 | 30-JUN-23:10 | 5056.80 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - ART CLASSROOM | 327.38 | 5219.12 | 30-JUN-23:10 | 20227.20 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDIO_1_F2 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.77 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - ART CLASSROOM | 128.89 | 1623.89 | 01-JAN-00:10 | 8243.10 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDIO_1_F2 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.77 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - ART CLASSROOM | 128.89 | 1623.89 | 01-JAN-00:10 | 8243.10 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDIO_1_F3 ZN | 81.84 | 1304.78 | 30-JUN-23:10 | 5056.80 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDIO_1_F3 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.77 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDIO_1_F3 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.77 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDIO_2_F2 ZN | 81.84 | 1304.78 | 30-JUN-23:10 | 5056.80 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDIO_2_F2 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.78 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDIO_2_F2 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.78 | 02-JAN-07:10 |
| Electricity:Zone:CB_STUDIO_2_F3 ZN | 81.84 | 1304.78 | 30-JUN-23:10 | 5056.80 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_STUDIO_2_F3 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.77 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_STUDIO_2_F3 ZN | 32.22 | 405.97 | 01-JAN-00:10 | 2060.77 | 02-JAN-07:10 |
| Electricity:Zone:CB_UTILITY_F1 ZN | 1.07 | 16.48 | 30-JUN-23:10 | 66.62 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - UTILITY | 4.29 | 65.91 | 30-JUN-23:10 | 266.46 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_UTILITY_F1 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| InteriorLights:Electricity:SpaceType:COLLEGE - UTILITY | 2.13 | 26.84 | 01-JAN-00:10 | 136.22 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_UTILITY_F1 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:SpaceType:COLLEGE - UTILITY | 2.13 | 26.84 | 01-JAN-00:10 | 136.22 | 02-JAN-07:10 |
| Electricity:Zone:CB_UTILITY_F4 ZN | 1.07 | 16.48 | 30-JUN-23:10 | 66.62 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_UTILITY_F4 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_UTILITY_F4 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| Electricity:Zone:CB_UTILITY_F3 ZN | 1.07 | 16.48 | 30-JUN-23:10 | 66.62 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_UTILITY_F3 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_UTILITY_F3 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| Electricity:Zone:CB_UTILITY_F2 ZN | 1.07 | 16.48 | 30-JUN-23:10 | 66.62 | 02-JAN-08:10 |
| InteriorLights:Electricity:Zone:CB_UTILITY_F2 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| General:InteriorLights:Electricity:Zone:CB_UTILITY_F2 ZN | 0.53 | 6.71 | 01-JAN-00:10 | 34.06 | 02-JAN-07:10 |
| InteriorEquipment:Electricity | 1519.23 | 26319.73 | 30-JUN-23:10 | 97070.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 229.15 | 4150.57 | 30-JUN-23:10 | 13835.25 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - LOUNGE | 229.15 | 4150.57 | 30-JUN-23:10 | 13835.25 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity | 1446.11 | 26193.12 | 30-JUN-23:10 | 87310.39 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 229.15 | 4150.57 | 30-JUN-23:10 | 13835.25 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - LOUNGE | 229.15 | 4150.57 | 30-JUN-23:10 | 13835.25 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_1_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - CLASSROOM | 249.27 | 4514.94 | 30-JUN-23:10 | 15049.80 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_1_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - CLASSROOM | 249.27 | 4514.94 | 30-JUN-23:10 | 15049.80 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_2_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_2_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_3_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_3_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_5_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_5_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_6_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_6_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_7_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_7_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_6_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_6_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_5_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_5_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_4_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_4_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_3_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_3_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_5_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_5_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_1_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_1_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_2_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_2_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_8_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_8_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_6_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_6_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_7_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_7_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_8_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_8_F3 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_4_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_4_F4 ZN | 12.46 | 225.75 | 30-JUN-23:10 | 752.49 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_4_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_4_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LECTURE_ROOM_2_F1 ZN | 24.93 | 451.49 | 30-JUN-23:10 | 1504.98 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LECTURE_ROOM_2_F1 ZN | 24.93 | 451.49 | 30-JUN-23:10 | 1504.98 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_2_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_2_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_1_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_1_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CLASSROOM_3_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CLASSROOM_3_F2 ZN | 9.35 | 169.31 | 30-JUN-23:10 | 564.37 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F4 ZN | 5.47 | 99.00 | 30-JUN-23:10 | 330.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - CONFERENCE | 24.60 | 445.50 | 30-JUN-23:10 | 1485.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F4 ZN | 5.47 | 99.00 | 30-JUN-23:10 | 330.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - CONFERENCE | 24.60 | 445.50 | 30-JUN-23:10 | 1485.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F3 ZN | 5.47 | 99.00 | 30-JUN-23:10 | 330.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F3 ZN | 5.47 | 99.00 | 30-JUN-23:10 | 330.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F1 ZN | 8.20 | 148.50 | 30-JUN-23:10 | 495.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F1 ZN | 8.20 | 148.50 | 30-JUN-23:10 | 495.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F2 ZN | 5.47 | 99.00 | 30-JUN-23:10 | 330.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CONFERENCE_ROOM_F2 ZN | 5.47 | 99.00 | 30-JUN-23:10 | 330.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CORRIDOR_F1 ZN | 8.06 | 145.96 | 30-JUN-23:10 | 486.55 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - CORRIDOR | 30.30 | 548.90 | 30-JUN-23:10 | 1829.65 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CORRIDOR_F1 ZN | 8.06 | 145.96 | 30-JUN-23:10 | 486.55 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - CORRIDOR | 30.30 | 548.90 | 30-JUN-23:10 | 1829.65 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CORRIDOR_F4 ZN | 9.99 | 180.93 | 30-JUN-23:10 | 603.10 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CORRIDOR_F4 ZN | 9.99 | 180.93 | 30-JUN-23:10 | 603.10 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CORRIDOR_F2 ZN | 6.13 | 111.00 | 30-JUN-23:10 | 370.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CORRIDOR_F2 ZN | 6.13 | 111.00 | 30-JUN-23:10 | 370.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CORRIDOR_2_F3 ZN | 4.04 | 73.26 | 30-JUN-23:10 | 244.20 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CORRIDOR_2_F3 ZN | 4.04 | 73.26 | 30-JUN-23:10 | 244.20 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_CORRIDOR_1_F3 ZN | 2.08 | 37.74 | 30-JUN-23:10 | 125.80 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_CORRIDOR_1_F3 ZN | 2.08 | 37.74 | 30-JUN-23:10 | 125.80 | 02-JAN-08:10 |
| Electricity:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 4.96 | 89.91 | 30-JUN-23:10 | 299.70 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - ENTRANCE LOBBY | 4.96 | 89.91 | 30-JUN-23:10 | 299.70 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 4.96 | 89.91 | 30-JUN-23:10 | 299.70 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - ENTRANCE LOBBY | 4.96 | 89.91 | 30-JUN-23:10 | 299.70 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 4.96 | 89.91 | 30-JUN-23:10 | 299.70 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - ENTRANCE LOBBY | 4.96 | 89.91 | 30-JUN-23:10 | 299.70 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - OFFICE | 216.63 | 3923.70 | 30-JUN-23:10 | 13079.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - OFFICE | 216.63 | 3923.70 | 30-JUN-23:10 | 13079.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F4 ZN | 37.35 | 676.50 | 30-JUN-23:10 | 2255.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F4 ZN | 37.35 | 676.50 | 30-JUN-23:10 | 2255.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F1 ZN | 34.62 | 627.00 | 30-JUN-23:10 | 2090.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F1 ZN | 34.62 | 627.00 | 30-JUN-23:10 | 2090.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F3 ZN | 37.35 | 676.50 | 30-JUN-23:10 | 2255.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F3 ZN | 37.35 | 676.50 | 30-JUN-23:10 | 2255.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F2 ZN | 37.35 | 676.50 | 30-JUN-23:10 | 2255.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_OFFICES_OPEN_F2 ZN | 37.35 | 676.50 | 30-JUN-23:10 | 2255.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 2.19 | 39.60 | 30-JUN-23:10 | 132.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - RESTROOM | 15.37 | 278.39 | 30-JUN-23:10 | 927.96 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - RESTROOM | 15.37 | 278.39 | 30-JUN-23:10 | 927.96 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.66 | 11.90 | 30-JUN-23:10 | 39.68 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 1.26 | 22.89 | 30-JUN-23:10 | 76.31 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LAB_3_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - LABORATORY | 385.58 | 6984.00 | 30-JUN-23:10 | 23280.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LAB_3_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - LABORATORY | 385.58 | 6984.00 | 30-JUN-23:10 | 23280.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LAB_4_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LAB_4_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LAB_1_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LAB_1_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LAB_2_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LAB_2_F4 ZN | 96.40 | 1746.00 | 30-JUN-23:10 | 5820.00 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LECTURE_ROOM_1_F1 ZN | 44.78 | 811.02 | 30-JUN-23:10 | 2703.39 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - LECTURE HALL | 44.78 | 811.02 | 30-JUN-23:10 | 2703.39 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LECTURE_ROOM_1_F1 ZN | 44.78 | 811.02 | 30-JUN-23:10 | 2703.39 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - LECTURE HALL | 44.78 | 811.02 | 30-JUN-23:10 | 2703.39 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 44.82 | 811.89 | 30-JUN-23:10 | 2706.30 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - MEDIA CENTER | 44.82 | 811.89 | 30-JUN-23:10 | 2706.30 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 44.82 | 811.89 | 30-JUN-23:10 | 2706.30 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - MEDIA CENTER | 44.82 | 811.89 | 30-JUN-23:10 | 2706.30 | 02-JAN-08:10 |
| Electricity:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| Electricity:SpaceType:COLLEGE - ELEVATOR SHAFT | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - ELEVATOR SHAFT | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| Elevators:InteriorEquipment:Electricity | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| Elevators:InteriorEquipment:Electricity:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| Elevators:InteriorEquipment:Electricity:SpaceType:COLLEGE - ELEVATOR SHAFT | 73.12 | 126.61 | 01-JAN-00:10 | 9759.61 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDIO_1_F2 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.02 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - ART CLASSROOM | 198.49 | 3595.23 | 30-JUN-23:10 | 11984.10 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDIO_1_F2 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.02 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - ART CLASSROOM | 198.49 | 3595.23 | 30-JUN-23:10 | 11984.10 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDIO_1_F3 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.02 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDIO_1_F3 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.02 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDIO_2_F2 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.03 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDIO_2_F2 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.03 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_STUDIO_2_F3 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.02 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_STUDIO_2_F3 ZN | 49.62 | 898.81 | 30-JUN-23:10 | 2996.02 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_UTILITY_F1 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:SpaceType:COLLEGE - UTILITY | 2.16 | 39.07 | 30-JUN-23:10 | 130.24 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_UTILITY_F1 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:SpaceType:COLLEGE - UTILITY | 2.16 | 39.07 | 30-JUN-23:10 | 130.24 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_UTILITY_F4 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_UTILITY_F4 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_UTILITY_F3 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_UTILITY_F3 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| InteriorEquipment:Electricity:Zone:CB_UTILITY_F2 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| General:InteriorEquipment:Electricity:Zone:CB_UTILITY_F2 ZN | 0.54 | 9.77 | 30-JUN-23:10 | 32.56 | 02-JAN-08:10 |
| ElectricityPurchased:Facility | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| ElectricityPurchased:Plant | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| Cogeneration:ElectricityPurchased | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| General:Cogeneration:ElectricityPurchased | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| ElectricitySurplusSold:Facility | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricitySurplusSold:Plant | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cogeneration:ElectricitySurplusSold | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| ElectricityNet:Facility | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| ElectricityNet:Plant | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| Cogeneration:ElectricityNet | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| General:Cogeneration:ElectricityNet | 3753.38 | 35156.43 | 30-JUN-23:10 | 288081.11 | 20-MAR-07:10 |
| Electricity:HVAC | 369.81 | 0.00 | 02-JAN-21:10 | 51025.80 | 02-JAN-13:40 |
| Fans:Electricity | 369.81 | 0.00 | 02-JAN-21:10 | 51025.80 | 02-JAN-13:40 |
| VAV System Fans:Fans:Electricity | 369.81 | 0.00 | 02-JAN-21:10 | 51025.80 | 02-JAN-13:40 |
| ExteriorLights:Electricity | 70.69 | 0.00 | 01-JAN-00:10 | 8993.80 | 01-JAN-06:10 |
| General:ExteriorLights:Electricity | 70.69 | 0.00 | 01-JAN-00:10 | 8993.80 | 01-JAN-06:10 |
| Electricity:Plant | 1092.28 | 0.00 | 02-JAN-21:10 | 89967.83 | 08-MAY-10:20 |
| Cooling:Electricity | 783.39 | 0.00 | 02-JAN-21:10 | 66597.43 | 08-MAY-10:10 |
| General:Cooling:Electricity | 783.39 | 0.00 | 02-JAN-21:10 | 66597.43 | 08-MAY-10:10 |
| HeatRejection:Electricity | 115.68 | 0.00 | 02-JAN-21:10 | 13826.58 | 02-JAN-08:30 |
| General:HeatRejection:Electricity | 115.68 | 0.00 | 02-JAN-21:10 | 13826.58 | 02-JAN-08:30 |
| Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Boiler Parasitic:Heating:Electricity | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Pumps:Electricity | 193.20 | 0.00 | 02-JAN-21:10 | 9770.17 | 02-JAN-08:10 |
| General:Pumps:Electricity | 193.20 | 0.00 | 02-JAN-21:10 | 9770.17 | 02-JAN-08:10 |
| Natural Gas Annual Value [GJ] | Natural Gas Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Natural Gas Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| NaturalGas:Facility | 306.33 | 8146.58 | 02-JAN-07:10 | 28778.77 | 24-JAN-13:20 |
| NaturalGas:Plant | 306.33 | 8146.58 | 02-JAN-07:10 | 28778.77 | 24-JAN-13:20 |
| Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:NaturalGas | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| WaterSystems:NaturalGas | 306.33 | 8146.58 | 02-JAN-07:10 | 28778.77 | 24-JAN-13:20 |
| General:WaterSystems:NaturalGas | 306.33 | 8146.58 | 02-JAN-07:10 | 28778.77 | 24-JAN-13:20 |
| Cooling Annual Value [GJ] | Cooling Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Cooling Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| PlantLoopCoolingDemand:Facility | 4386.26 | 0.00 | 02-JAN-21:10 | 438964.05 | 26-JAN-08:10 |
| PlantLoopCoolingDemand:HVAC | 4386.26 | 0.00 | 02-JAN-21:10 | 438964.05 | 26-JAN-08:10 |
| CoolingCoils:PlantLoopCoolingDemand | 4386.26 | 0.00 | 02-JAN-21:10 | 438964.05 | 26-JAN-08:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| Water:Facility | 3678.59 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| Water:Plant | 3678.59 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| WaterSystems:Water | 198.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-13:10 |
| General:WaterSystems:Water | 198.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-13:10 |
| MainsWater:Facility | 3678.59 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| MainsWater:Plant | 3678.59 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| WaterSystems:MainsWater | 198.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-13:10 |
| General:WaterSystems:MainsWater | 198.99 | 0.00 | 01-JAN-00:10 | 0.00 | 02-JAN-13:10 |
| HeatRejection:Water | 3479.60 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| General:HeatRejection:Water | 3479.60 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| HeatRejection:MainsWater | 3479.60 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| General:HeatRejection:MainsWater | 3479.60 | 0.00 | 02-JAN-21:10 | 0.00 | 04-APR-14:00 |
| Annual Value [kg] | Minimum Value [kg/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [kg/s] | Timestamp of Maximum {TIMESTAMP} | |
| Carbon Equivalent:Facility | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| CarbonEquivalentEmissions:Carbon Equivalent | 0.00 | 0.000 | 01-JAN-00:10 | 0.000 | 01-JAN-00:10 |
| Annual Value [m3] | Minimum Value [m3/s] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [m3/s] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [L] | Minimum Value [L] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [L] | Timestamp of Maximum {TIMESTAMP} | |
| None |
| Annual Value [GJ] | Minimum Value [W] | Timestamp of Minimum {TIMESTAMP} | Maximum Value [W] | Timestamp of Maximum {TIMESTAMP} | |
| EnergyTransfer:Facility | 17505.61 | 0.00 | 02-JAN-21:10 | 1657784.53 | 02-JAN-12:20 |
| EnergyTransfer:Building | 3177.24 | 0.00 | 02-JAN-21:10 | 309033.41 | 02-JAN-12:20 |
| EnergyTransfer:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 224.66 | 0.00 | 01-JAN-00:40 | 19981.41 | 25-DEC-12:30 |
| Heating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer | 3177.24 | 0.00 | 02-JAN-21:10 | 309033.41 | 02-JAN-12:20 |
| Cooling:EnergyTransfer:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 224.66 | 0.00 | 01-JAN-00:40 | 19981.41 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer | 3177.24 | 0.00 | 02-JAN-21:10 | 309033.41 | 02-JAN-12:20 |
| General:Cooling:EnergyTransfer:Zone:CB_CAFE_STUDY_LOUNGE_F1 ZN | 224.66 | 0.00 | 01-JAN-00:40 | 19981.41 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_1_F2 ZN | 34.67 | 0.00 | 01-JAN-00:10 | 4082.68 | 25-DEC-12:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_1_F2 ZN | 34.67 | 0.00 | 01-JAN-00:10 | 4082.68 | 25-DEC-12:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_1_F2 ZN | 34.67 | 0.00 | 01-JAN-00:10 | 4082.68 | 25-DEC-12:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_1_F3 ZN | 35.17 | 0.00 | 01-JAN-00:40 | 4080.98 | 25-DEC-12:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_1_F3 ZN | 35.17 | 0.00 | 01-JAN-00:40 | 4080.98 | 25-DEC-12:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_1_F3 ZN | 35.17 | 0.00 | 01-JAN-00:40 | 4080.98 | 25-DEC-12:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_1_F4 ZN | 46.20 | 0.00 | 01-JAN-00:40 | 5893.85 | 28-DEC-16:00 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_1_F4 ZN | 46.20 | 0.00 | 01-JAN-00:40 | 5893.85 | 28-DEC-16:00 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_1_F4 ZN | 46.20 | 0.00 | 01-JAN-00:40 | 5893.85 | 28-DEC-16:00 |
| EnergyTransfer:Zone:CB_CLASSROOM_2_F2 ZN | 29.78 | 0.00 | 01-JAN-00:10 | 3227.29 | 30-OCT-06:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_2_F2 ZN | 29.78 | 0.00 | 01-JAN-00:10 | 3227.29 | 30-OCT-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_2_F2 ZN | 29.78 | 0.00 | 01-JAN-00:10 | 3227.29 | 30-OCT-06:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_2_F3 ZN | 30.07 | 0.00 | 01-JAN-00:40 | 3234.94 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_2_F3 ZN | 30.07 | 0.00 | 01-JAN-00:40 | 3234.94 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_2_F3 ZN | 30.07 | 0.00 | 01-JAN-00:40 | 3234.94 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_2_F4 ZN | 40.26 | 0.00 | 01-JAN-00:40 | 4600.61 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_2_F4 ZN | 40.26 | 0.00 | 01-JAN-00:40 | 4600.61 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_2_F4 ZN | 40.26 | 0.00 | 01-JAN-00:40 | 4600.61 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_3_F2 ZN | 29.71 | 0.00 | 01-JAN-00:10 | 3210.79 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_3_F2 ZN | 29.71 | 0.00 | 01-JAN-00:10 | 3210.79 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_3_F2 ZN | 29.71 | 0.00 | 01-JAN-00:10 | 3210.79 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_3_F3 ZN | 29.63 | 0.00 | 01-JAN-00:40 | 3169.63 | 30-OCT-06:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_3_F3 ZN | 29.63 | 0.00 | 01-JAN-00:40 | 3169.63 | 30-OCT-06:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_3_F3 ZN | 29.63 | 0.00 | 01-JAN-00:40 | 3169.63 | 30-OCT-06:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_3_F4 ZN | 39.24 | 0.00 | 01-JAN-00:40 | 4526.05 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_3_F4 ZN | 39.24 | 0.00 | 01-JAN-00:40 | 4526.05 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_3_F4 ZN | 39.24 | 0.00 | 01-JAN-00:40 | 4526.05 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_4_F2 ZN | 32.09 | 0.00 | 01-JAN-00:10 | 3454.92 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_4_F2 ZN | 32.09 | 0.00 | 01-JAN-00:10 | 3454.92 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_4_F2 ZN | 32.09 | 0.00 | 01-JAN-00:10 | 3454.92 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_4_F3 ZN | 30.09 | 0.00 | 01-JAN-00:40 | 3165.93 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_4_F3 ZN | 30.09 | 0.00 | 01-JAN-00:40 | 3165.93 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_4_F3 ZN | 30.09 | 0.00 | 01-JAN-00:40 | 3165.93 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_4_F4 ZN | 40.54 | 0.00 | 01-JAN-00:40 | 4637.11 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_4_F4 ZN | 40.54 | 0.00 | 01-JAN-00:40 | 4637.11 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_4_F4 ZN | 40.54 | 0.00 | 01-JAN-00:40 | 4637.11 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_5_F2 ZN | 28.32 | 0.00 | 01-JAN-00:10 | 3055.36 | 02-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_5_F2 ZN | 28.32 | 0.00 | 01-JAN-00:10 | 3055.36 | 02-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_5_F2 ZN | 28.32 | 0.00 | 01-JAN-00:10 | 3055.36 | 02-JAN-07:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_5_F3 ZN | 28.60 | 0.00 | 01-JAN-00:40 | 3065.97 | 30-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_5_F3 ZN | 28.60 | 0.00 | 01-JAN-00:40 | 3065.97 | 30-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_5_F3 ZN | 28.60 | 0.00 | 01-JAN-00:40 | 3065.97 | 30-JAN-07:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_5_F4 ZN | 40.27 | 0.00 | 01-JAN-00:40 | 4622.38 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_5_F4 ZN | 40.27 | 0.00 | 01-JAN-00:40 | 4622.38 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_5_F4 ZN | 40.27 | 0.00 | 01-JAN-00:40 | 4622.38 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_6_F2 ZN | 31.20 | 0.00 | 01-JAN-00:10 | 3273.91 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_6_F2 ZN | 31.20 | 0.00 | 01-JAN-00:10 | 3273.91 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_6_F2 ZN | 31.20 | 0.00 | 01-JAN-00:10 | 3273.91 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_6_F3 ZN | 29.70 | 0.00 | 01-JAN-00:40 | 3170.75 | 30-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_6_F3 ZN | 29.70 | 0.00 | 01-JAN-00:40 | 3170.75 | 30-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_6_F3 ZN | 29.70 | 0.00 | 01-JAN-00:40 | 3170.75 | 30-JAN-07:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_6_F4 ZN | 46.19 | 0.00 | 01-JAN-00:40 | 5483.36 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_6_F4 ZN | 46.19 | 0.00 | 01-JAN-00:40 | 5483.36 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_6_F4 ZN | 46.19 | 0.00 | 01-JAN-00:40 | 5483.36 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_CLASSROOM_7_F2 ZN | 33.01 | 0.00 | 01-JAN-00:10 | 3436.94 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_7_F2 ZN | 33.01 | 0.00 | 01-JAN-00:10 | 3436.94 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_7_F2 ZN | 33.01 | 0.00 | 01-JAN-00:10 | 3436.94 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_7_F3 ZN | 30.50 | 0.00 | 01-JAN-00:40 | 3259.65 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_7_F3 ZN | 30.50 | 0.00 | 01-JAN-00:40 | 3259.65 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_7_F3 ZN | 30.50 | 0.00 | 01-JAN-00:40 | 3259.65 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_CLASSROOM_8_F2 ZN | 38.35 | 0.00 | 01-JAN-00:10 | 4379.20 | 28-DEC-16:00 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_8_F2 ZN | 38.35 | 0.00 | 01-JAN-00:10 | 4379.20 | 28-DEC-16:00 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_8_F2 ZN | 38.35 | 0.00 | 01-JAN-00:10 | 4379.20 | 28-DEC-16:00 |
| EnergyTransfer:Zone:CB_CLASSROOM_8_F3 ZN | 35.74 | 0.00 | 01-JAN-00:40 | 4200.89 | 28-DEC-16:00 |
| Heating:EnergyTransfer:Zone:CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CLASSROOM_8_F3 ZN | 35.74 | 0.00 | 01-JAN-00:40 | 4200.89 | 28-DEC-16:00 |
| General:Cooling:EnergyTransfer:Zone:CB_CLASSROOM_8_F3 ZN | 35.74 | 0.00 | 01-JAN-00:40 | 4200.89 | 28-DEC-16:00 |
| EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F1 ZN | 41.30 | 0.00 | 01-JAN-00:40 | 2655.33 | 05-DEC-13:10 |
| Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F1 ZN | 41.30 | 0.00 | 01-JAN-00:40 | 2655.33 | 05-DEC-13:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F1 ZN | 41.30 | 0.00 | 01-JAN-00:40 | 2655.33 | 05-DEC-13:10 |
| EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F2 ZN | 21.42 | 0.00 | 01-JAN-00:10 | 1867.25 | 05-DEC-13:10 |
| Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F2 ZN | 21.42 | 0.00 | 01-JAN-00:10 | 1867.25 | 05-DEC-13:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F2 ZN | 21.42 | 0.00 | 01-JAN-00:10 | 1867.25 | 05-DEC-13:10 |
| EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F3 ZN | 21.69 | 0.00 | 01-JAN-00:40 | 1883.36 | 04-SEP-11:10 |
| Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F3 ZN | 21.69 | 0.00 | 01-JAN-00:40 | 1883.36 | 04-SEP-11:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F3 ZN | 21.69 | 0.00 | 01-JAN-00:40 | 1883.36 | 04-SEP-11:10 |
| EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F4 ZN | 27.60 | 0.00 | 01-JAN-00:40 | 2093.06 | 13-FEB-13:10 |
| Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F4 ZN | 27.60 | 0.00 | 01-JAN-00:40 | 2093.06 | 13-FEB-13:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CONFERENCE_ROOM_F4 ZN | 27.60 | 0.00 | 01-JAN-00:40 | 2093.06 | 13-FEB-13:10 |
| EnergyTransfer:Zone:CB_CORRIDOR_1_F3 ZN | 8.54 | 0.00 | 01-JAN-00:40 | 811.89 | 02-JAN-07:40 |
| Heating:EnergyTransfer:Zone:CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CORRIDOR_1_F3 ZN | 8.54 | 0.00 | 01-JAN-00:40 | 811.89 | 02-JAN-07:40 |
| General:Cooling:EnergyTransfer:Zone:CB_CORRIDOR_1_F3 ZN | 8.54 | 0.00 | 01-JAN-00:40 | 811.89 | 02-JAN-07:40 |
| EnergyTransfer:Zone:CB_CORRIDOR_2_F3 ZN | 13.00 | 0.00 | 01-JAN-00:40 | 1183.23 | 02-JAN-06:10 |
| Heating:EnergyTransfer:Zone:CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CORRIDOR_2_F3 ZN | 13.00 | 0.00 | 01-JAN-00:40 | 1183.23 | 02-JAN-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CORRIDOR_2_F3 ZN | 13.00 | 0.00 | 01-JAN-00:40 | 1183.23 | 02-JAN-06:10 |
| EnergyTransfer:Zone:CB_CORRIDOR_F1 ZN | 53.02 | 0.00 | 01-JAN-00:40 | 5644.14 | 02-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CORRIDOR_F1 ZN | 53.02 | 0.00 | 01-JAN-00:40 | 5644.14 | 02-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_CORRIDOR_F1 ZN | 53.02 | 0.00 | 01-JAN-00:40 | 5644.14 | 02-JAN-07:30 |
| EnergyTransfer:Zone:CB_CORRIDOR_F2 ZN | 24.77 | 0.00 | 01-JAN-00:10 | 2324.94 | 02-JAN-07:40 |
| Heating:EnergyTransfer:Zone:CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CORRIDOR_F2 ZN | 24.77 | 0.00 | 01-JAN-00:10 | 2324.94 | 02-JAN-07:40 |
| General:Cooling:EnergyTransfer:Zone:CB_CORRIDOR_F2 ZN | 24.77 | 0.00 | 01-JAN-00:10 | 2324.94 | 02-JAN-07:40 |
| EnergyTransfer:Zone:CB_CORRIDOR_F4 ZN | 46.52 | 0.00 | 01-JAN-00:40 | 4596.19 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_CORRIDOR_F4 ZN | 46.52 | 0.00 | 01-JAN-00:40 | 4596.19 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_CORRIDOR_F4 ZN | 46.52 | 0.00 | 01-JAN-00:40 | 4596.19 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 20.38 | 0.00 | 01-JAN-00:40 | 2188.32 | 02-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 20.38 | 0.00 | 01-JAN-00:40 | 2188.32 | 02-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_ENTRANCE_LOBBY_F1 ZN | 20.38 | 0.00 | 01-JAN-00:40 | 2188.32 | 02-JAN-07:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 6.45 | 0.00 | 01-JAN-00:10 | 736.69 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 6.45 | 0.00 | 01-JAN-00:10 | 736.69 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F2 ZN | 6.45 | 0.00 | 01-JAN-00:10 | 736.69 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 6.65 | 0.00 | 01-JAN-00:40 | 744.55 | 05-JUN-15:00 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 6.65 | 0.00 | 01-JAN-00:40 | 744.55 | 05-JUN-15:00 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F3 ZN | 6.65 | 0.00 | 01-JAN-00:40 | 744.55 | 05-JUN-15:00 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 7.26 | 0.00 | 01-JAN-00:40 | 863.07 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 7.26 | 0.00 | 01-JAN-00:40 | 863.07 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_1_F4 ZN | 7.26 | 0.00 | 01-JAN-00:40 | 863.07 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 6.33 | 0.00 | 01-JAN-00:10 | 736.28 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 6.33 | 0.00 | 01-JAN-00:10 | 736.28 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F2 ZN | 6.33 | 0.00 | 01-JAN-00:10 | 736.28 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 6.48 | 0.00 | 01-JAN-00:40 | 743.10 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 6.48 | 0.00 | 01-JAN-00:40 | 743.10 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F3 ZN | 6.48 | 0.00 | 01-JAN-00:40 | 743.10 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 6.83 | 0.00 | 01-JAN-00:40 | 844.75 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 6.83 | 0.00 | 01-JAN-00:40 | 844.75 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_2_F4 ZN | 6.83 | 0.00 | 01-JAN-00:40 | 844.75 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 735.14 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 735.14 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 735.14 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 742.21 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 742.21 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F3 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 742.21 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 6.76 | 0.00 | 01-JAN-00:40 | 842.79 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 6.76 | 0.00 | 01-JAN-00:40 | 842.79 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_3_F4 ZN | 6.76 | 0.00 | 01-JAN-00:40 | 842.79 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 734.58 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 734.58 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 734.58 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 6.43 | 0.00 | 01-JAN-00:40 | 742.13 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 6.43 | 0.00 | 01-JAN-00:40 | 742.13 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F3 ZN | 6.43 | 0.00 | 01-JAN-00:40 | 742.13 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 6.75 | 0.00 | 01-JAN-00:40 | 842.53 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 6.75 | 0.00 | 01-JAN-00:40 | 842.53 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_4_F4 ZN | 6.75 | 0.00 | 01-JAN-00:40 | 842.53 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 734.49 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 734.49 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 734.49 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 6.43 | 0.00 | 01-JAN-00:40 | 742.23 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 6.43 | 0.00 | 01-JAN-00:40 | 742.23 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F3 ZN | 6.43 | 0.00 | 01-JAN-00:40 | 742.23 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 6.75 | 0.00 | 01-JAN-00:40 | 842.59 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 6.75 | 0.00 | 01-JAN-00:40 | 842.59 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_5_F4 ZN | 6.75 | 0.00 | 01-JAN-00:40 | 842.59 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 735.16 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 735.16 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F2 ZN | 6.30 | 0.00 | 01-JAN-00:10 | 735.16 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 742.24 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 742.24 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F3 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 742.24 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 6.76 | 0.00 | 01-JAN-00:40 | 842.80 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 6.76 | 0.00 | 01-JAN-00:40 | 842.80 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_6_F4 ZN | 6.76 | 0.00 | 01-JAN-00:40 | 842.80 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 6.32 | 0.00 | 01-JAN-00:10 | 734.88 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 6.32 | 0.00 | 01-JAN-00:10 | 734.88 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F2 ZN | 6.32 | 0.00 | 01-JAN-00:10 | 734.88 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 6.47 | 0.00 | 01-JAN-00:40 | 742.44 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 6.47 | 0.00 | 01-JAN-00:40 | 742.44 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F3 ZN | 6.47 | 0.00 | 01-JAN-00:40 | 742.44 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 6.83 | 0.00 | 01-JAN-00:40 | 844.54 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 6.83 | 0.00 | 01-JAN-00:40 | 844.54 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_7_F4 ZN | 6.83 | 0.00 | 01-JAN-00:40 | 844.54 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 6.40 | 0.00 | 01-JAN-00:10 | 732.81 | 12-JUN-13:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 6.40 | 0.00 | 01-JAN-00:10 | 732.81 | 12-JUN-13:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F2 ZN | 6.40 | 0.00 | 01-JAN-00:10 | 732.81 | 12-JUN-13:50 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 6.62 | 0.00 | 01-JAN-00:40 | 742.27 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 6.62 | 0.00 | 01-JAN-00:40 | 742.27 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F3 ZN | 6.62 | 0.00 | 01-JAN-00:40 | 742.27 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 7.24 | 0.00 | 01-JAN-00:40 | 862.32 | 30-MAY-15:10 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 7.24 | 0.00 | 01-JAN-00:40 | 862.32 | 30-MAY-15:10 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_OFFICE_8_F4 ZN | 7.24 | 0.00 | 01-JAN-00:40 | 862.32 | 30-MAY-15:10 |
| EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.04 | 0.00 | 01-JAN-00:10 | 63.38 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.04 | 0.00 | 01-JAN-00:10 | 63.38 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F2 ZN | 0.04 | 0.00 | 01-JAN-00:10 | 63.38 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.04 | 0.00 | 01-JAN-00:40 | 67.03 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.04 | 0.00 | 01-JAN-00:40 | 67.03 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F3 ZN | 0.04 | 0.00 | 01-JAN-00:40 | 67.03 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.08 | 0.00 | 01-JAN-00:40 | 62.20 | 01-JAN-14:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.08 | 0.00 | 01-JAN-00:40 | 62.20 | 01-JAN-14:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_1_F4 ZN | 0.08 | 0.00 | 01-JAN-00:40 | 62.20 | 01-JAN-14:50 |
| EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.04 | 0.00 | 01-JAN-00:10 | 66.12 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.04 | 0.00 | 01-JAN-00:10 | 66.12 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F2 ZN | 0.04 | 0.00 | 01-JAN-00:10 | 66.12 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.04 | 0.00 | 01-JAN-00:40 | 67.43 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.04 | 0.00 | 01-JAN-00:40 | 67.43 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F3 ZN | 0.04 | 0.00 | 01-JAN-00:40 | 67.43 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.08 | 0.00 | 01-JAN-00:40 | 66.03 | 01-JAN-14:50 |
| Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.08 | 0.00 | 01-JAN-00:40 | 66.03 | 01-JAN-14:50 |
| General:Cooling:EnergyTransfer:Zone:CB_FACULTY_RESTROOMS_2_F4 ZN | 0.08 | 0.00 | 01-JAN-00:40 | 66.03 | 01-JAN-14:50 |
| EnergyTransfer:Zone:CB_LAB_1_F4 ZN | 128.63 | 0.00 | 01-JAN-00:40 | 12590.72 | 20-NOV-17:00 |
| Heating:EnergyTransfer:Zone:CB_LAB_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LAB_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LAB_1_F4 ZN | 128.63 | 0.00 | 01-JAN-00:40 | 12590.72 | 20-NOV-17:00 |
| General:Cooling:EnergyTransfer:Zone:CB_LAB_1_F4 ZN | 128.63 | 0.00 | 01-JAN-00:40 | 12590.72 | 20-NOV-17:00 |
| EnergyTransfer:Zone:CB_LAB_2_F4 ZN | 116.11 | 0.00 | 01-JAN-00:40 | 10758.54 | 12-JUN-07:10 |
| Heating:EnergyTransfer:Zone:CB_LAB_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LAB_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LAB_2_F4 ZN | 116.11 | 0.00 | 01-JAN-00:40 | 10758.54 | 12-JUN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_LAB_2_F4 ZN | 116.11 | 0.00 | 01-JAN-00:40 | 10758.54 | 12-JUN-07:10 |
| EnergyTransfer:Zone:CB_LAB_3_F4 ZN | 118.84 | 0.00 | 01-JAN-00:40 | 10802.10 | 12-JUN-07:10 |
| Heating:EnergyTransfer:Zone:CB_LAB_3_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LAB_3_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LAB_3_F4 ZN | 118.84 | 0.00 | 01-JAN-00:40 | 10802.10 | 12-JUN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_LAB_3_F4 ZN | 118.84 | 0.00 | 01-JAN-00:40 | 10802.10 | 12-JUN-07:10 |
| EnergyTransfer:Zone:CB_LAB_4_F4 ZN | 129.72 | 0.00 | 01-JAN-00:40 | 12696.48 | 15-MAY-10:50 |
| Heating:EnergyTransfer:Zone:CB_LAB_4_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LAB_4_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LAB_4_F4 ZN | 129.72 | 0.00 | 01-JAN-00:40 | 12696.48 | 15-MAY-10:50 |
| General:Cooling:EnergyTransfer:Zone:CB_LAB_4_F4 ZN | 129.72 | 0.00 | 01-JAN-00:40 | 12696.48 | 15-MAY-10:50 |
| EnergyTransfer:Zone:CB_LECTURE_ROOM_1_F1 ZN | 121.46 | 0.00 | 01-JAN-00:40 | 14196.47 | 02-JAN-07:20 |
| Heating:EnergyTransfer:Zone:CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LECTURE_ROOM_1_F1 ZN | 121.46 | 0.00 | 01-JAN-00:40 | 14196.47 | 02-JAN-07:20 |
| General:Cooling:EnergyTransfer:Zone:CB_LECTURE_ROOM_1_F1 ZN | 121.46 | 0.00 | 01-JAN-00:40 | 14196.47 | 02-JAN-07:20 |
| EnergyTransfer:Zone:CB_LECTURE_ROOM_2_F1 ZN | 80.73 | 0.00 | 01-JAN-00:40 | 8940.41 | 02-JAN-07:20 |
| Heating:EnergyTransfer:Zone:CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LECTURE_ROOM_2_F1 ZN | 80.73 | 0.00 | 01-JAN-00:40 | 8940.41 | 02-JAN-07:20 |
| General:Cooling:EnergyTransfer:Zone:CB_LECTURE_ROOM_2_F1 ZN | 80.73 | 0.00 | 01-JAN-00:40 | 8940.41 | 02-JAN-07:20 |
| EnergyTransfer:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 122.57 | 0.00 | 01-JAN-00:40 | 12254.00 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 122.57 | 0.00 | 01-JAN-00:40 | 12254.00 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_LIBRARY_MEDIA_CENTER_F1 ZN | 122.57 | 0.00 | 01-JAN-00:40 | 12254.00 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_MAIN_STAIRS_F1 ZN | 5.39 | 0.00 | 01-JAN-00:40 | 527.98 | 02-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F1 ZN | 5.39 | 0.00 | 01-JAN-00:40 | 527.98 | 02-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F1 ZN | 5.39 | 0.00 | 01-JAN-00:40 | 527.98 | 02-JAN-07:30 |
| EnergyTransfer:Zone:CB_MAIN_STAIRS_F2 ZN | 4.95 | 0.00 | 01-JAN-00:10 | 486.08 | 02-JAN-07:40 |
| Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F2 ZN | 4.95 | 0.00 | 01-JAN-00:10 | 486.08 | 02-JAN-07:40 |
| General:Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F2 ZN | 4.95 | 0.00 | 01-JAN-00:10 | 486.08 | 02-JAN-07:40 |
| EnergyTransfer:Zone:CB_MAIN_STAIRS_F3 ZN | 4.94 | 0.00 | 01-JAN-00:40 | 484.80 | 02-JAN-07:40 |
| Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F3 ZN | 4.94 | 0.00 | 01-JAN-00:40 | 484.80 | 02-JAN-07:40 |
| General:Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F3 ZN | 4.94 | 0.00 | 01-JAN-00:40 | 484.80 | 02-JAN-07:40 |
| EnergyTransfer:Zone:CB_MAIN_STAIRS_F4 ZN | 5.74 | 0.00 | 01-JAN-00:40 | 626.82 | 05-JUN-06:20 |
| Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F4 ZN | 5.74 | 0.00 | 01-JAN-00:40 | 626.82 | 05-JUN-06:20 |
| General:Cooling:EnergyTransfer:Zone:CB_MAIN_STAIRS_F4 ZN | 5.74 | 0.00 | 01-JAN-00:40 | 626.82 | 05-JUN-06:20 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 6.57 | 0.00 | 01-JAN-00:40 | 707.07 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 6.57 | 0.00 | 01-JAN-00:40 | 707.07 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_1_F1 ZN | 6.57 | 0.00 | 01-JAN-00:40 | 707.07 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 706.12 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 706.12 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_2_F1 ZN | 6.44 | 0.00 | 01-JAN-00:40 | 706.12 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.83 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.83 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_3_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.83 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.81 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.81 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_4_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.81 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.73 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.73 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_5_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.73 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.60 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.60 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_6_F1 ZN | 6.41 | 0.00 | 01-JAN-00:40 | 705.60 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 6.42 | 0.00 | 01-JAN-00:40 | 705.34 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 6.42 | 0.00 | 01-JAN-00:40 | 705.34 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_7_F1 ZN | 6.42 | 0.00 | 01-JAN-00:40 | 705.34 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 6.46 | 0.00 | 01-JAN-00:40 | 702.82 | 05-JUN-15:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 6.46 | 0.00 | 01-JAN-00:40 | 702.82 | 05-JUN-15:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_ENCLOSED_8_F1 ZN | 6.46 | 0.00 | 01-JAN-00:40 | 702.82 | 05-JUN-15:30 |
| EnergyTransfer:Zone:CB_OFFICES_OPEN_F1 ZN | 66.08 | 0.00 | 01-JAN-00:40 | 6031.84 | 02-JAN-07:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F1 ZN | 66.08 | 0.00 | 01-JAN-00:40 | 6031.84 | 02-JAN-07:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F1 ZN | 66.08 | 0.00 | 01-JAN-00:40 | 6031.84 | 02-JAN-07:30 |
| EnergyTransfer:Zone:CB_OFFICES_OPEN_F2 ZN | 66.57 | 0.00 | 01-JAN-00:10 | 6347.34 | 02-JAN-07:40 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F2 ZN | 66.57 | 0.00 | 01-JAN-00:10 | 6347.34 | 02-JAN-07:40 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F2 ZN | 66.57 | 0.00 | 01-JAN-00:10 | 6347.34 | 02-JAN-07:40 |
| EnergyTransfer:Zone:CB_OFFICES_OPEN_F3 ZN | 67.91 | 0.00 | 01-JAN-00:40 | 6416.56 | 19-JUN-06:30 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F3 ZN | 67.91 | 0.00 | 01-JAN-00:40 | 6416.56 | 19-JUN-06:30 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F3 ZN | 67.91 | 0.00 | 01-JAN-00:40 | 6416.56 | 19-JUN-06:30 |
| EnergyTransfer:Zone:CB_OFFICES_OPEN_F4 ZN | 78.24 | 0.00 | 01-JAN-00:40 | 7913.29 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F4 ZN | 78.24 | 0.00 | 01-JAN-00:40 | 7913.29 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_OFFICES_OPEN_F4 ZN | 78.24 | 0.00 | 01-JAN-00:40 | 7913.29 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Cooling:EnergyTransfer:Zone:CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 6.60 | 0.00 | 01-JAN-00:40 | 750.28 | 25-SEP-16:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 6.60 | 0.00 | 01-JAN-00:40 | 750.28 | 25-SEP-16:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F1 ZN | 6.60 | 0.00 | 01-JAN-00:40 | 750.28 | 25-SEP-16:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 5.19 | 0.00 | 01-JAN-00:10 | 683.42 | 12-JUN-07:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 5.19 | 0.00 | 01-JAN-00:10 | 683.42 | 12-JUN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F2 ZN | 5.19 | 0.00 | 01-JAN-00:10 | 683.42 | 12-JUN-07:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 5.20 | 0.00 | 01-JAN-00:40 | 689.83 | 12-JUN-07:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 5.20 | 0.00 | 01-JAN-00:40 | 689.83 | 12-JUN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F3 ZN | 5.20 | 0.00 | 01-JAN-00:40 | 689.83 | 12-JUN-07:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 5.76 | 0.00 | 01-JAN-00:40 | 840.18 | 20-NOV-17:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 5.76 | 0.00 | 01-JAN-00:40 | 840.18 | 20-NOV-17:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_1_F4 ZN | 5.76 | 0.00 | 01-JAN-00:40 | 840.18 | 20-NOV-17:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 5.07 | 0.00 | 01-JAN-00:40 | 637.57 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 5.07 | 0.00 | 01-JAN-00:40 | 637.57 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F1 ZN | 5.07 | 0.00 | 01-JAN-00:40 | 637.57 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 4.98 | 0.00 | 01-JAN-00:10 | 649.88 | 23-OCT-10:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 4.98 | 0.00 | 01-JAN-00:10 | 649.88 | 23-OCT-10:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F2 ZN | 4.98 | 0.00 | 01-JAN-00:10 | 649.88 | 23-OCT-10:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 5.21 | 0.00 | 01-JAN-00:40 | 659.47 | 23-OCT-10:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 5.21 | 0.00 | 01-JAN-00:40 | 659.47 | 23-OCT-10:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F3 ZN | 5.21 | 0.00 | 01-JAN-00:40 | 659.47 | 23-OCT-10:10 |
| EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 5.85 | 0.00 | 01-JAN-00:40 | 775.61 | 23-OCT-10:10 |
| Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 5.85 | 0.00 | 01-JAN-00:40 | 775.61 | 23-OCT-10:10 |
| General:Cooling:EnergyTransfer:Zone:CB_SECONDARY_STAIRS_2_F4 ZN | 5.85 | 0.00 | 01-JAN-00:40 | 775.61 | 23-OCT-10:10 |
| EnergyTransfer:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.05 | 0.00 | 01-JAN-00:40 | 69.89 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.05 | 0.00 | 01-JAN-00:40 | 69.89 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_1_F1 ZN | 0.05 | 0.00 | 01-JAN-00:40 | 69.89 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.06 | 0.00 | 01-JAN-00:40 | 64.59 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.06 | 0.00 | 01-JAN-00:40 | 64.59 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STAFF_RESTROOMS_2_F1 ZN | 0.06 | 0.00 | 01-JAN-00:40 | 64.59 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_STORAGE_F1 ZN | 42.52 | 0.00 | 01-JAN-00:40 | 4670.05 | 25-DEC-12:30 |
| Heating:EnergyTransfer:Zone:CB_STORAGE_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STORAGE_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STORAGE_F1 ZN | 42.52 | 0.00 | 01-JAN-00:40 | 4670.05 | 25-DEC-12:30 |
| General:Cooling:EnergyTransfer:Zone:CB_STORAGE_F1 ZN | 42.52 | 0.00 | 01-JAN-00:40 | 4670.05 | 25-DEC-12:30 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.10 | 0.00 | 01-JAN-00:40 | 142.31 | 02-JAN-08:40 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.10 | 0.00 | 01-JAN-00:40 | 142.31 | 02-JAN-08:40 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.10 | 0.00 | 01-JAN-00:40 | 142.31 | 02-JAN-08:40 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.07 | 0.00 | 01-JAN-00:10 | 140.15 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.07 | 0.00 | 01-JAN-00:10 | 140.15 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.07 | 0.00 | 01-JAN-00:10 | 140.15 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.13 | 0.00 | 01-JAN-00:40 | 143.60 | 02-JAN-08:30 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.13 | 0.00 | 01-JAN-00:40 | 143.60 | 02-JAN-08:30 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.13 | 0.00 | 01-JAN-00:40 | 143.60 | 02-JAN-08:30 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.20 | 0.00 | 01-JAN-00:40 | 120.52 | 01-JAN-14:50 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.20 | 0.00 | 01-JAN-00:40 | 120.52 | 01-JAN-14:50 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.20 | 0.00 | 01-JAN-00:40 | 120.52 | 01-JAN-14:50 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.11 | 0.00 | 01-JAN-00:40 | 131.09 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.11 | 0.00 | 01-JAN-00:40 | 131.09 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.11 | 0.00 | 01-JAN-00:40 | 131.09 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.08 | 0.00 | 01-JAN-00:10 | 128.39 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.08 | 0.00 | 01-JAN-00:10 | 128.39 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.08 | 0.00 | 01-JAN-00:10 | 128.39 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.12 | 0.00 | 01-JAN-00:40 | 131.34 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.12 | 0.00 | 01-JAN-00:40 | 131.34 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.12 | 0.00 | 01-JAN-00:40 | 131.34 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.27 | 0.00 | 01-JAN-00:40 | 165.61 | 08-OCT-14:50 |
| Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.27 | 0.00 | 01-JAN-00:40 | 165.61 | 08-OCT-14:50 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.27 | 0.00 | 01-JAN-00:40 | 165.61 | 08-OCT-14:50 |
| EnergyTransfer:Zone:CB_STUDIO_1_F2 ZN | 119.75 | 0.00 | 01-JAN-00:10 | 13871.11 | 02-JAN-07:10 |
| Heating:EnergyTransfer:Zone:CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDIO_1_F2 ZN | 119.75 | 0.00 | 01-JAN-00:10 | 13871.11 | 02-JAN-07:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDIO_1_F2 ZN | 119.75 | 0.00 | 01-JAN-00:10 | 13871.11 | 02-JAN-07:10 |
| EnergyTransfer:Zone:CB_STUDIO_1_F3 ZN | 128.25 | 0.00 | 01-JAN-00:40 | 12984.62 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDIO_1_F3 ZN | 128.25 | 0.00 | 01-JAN-00:40 | 12984.62 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDIO_1_F3 ZN | 128.25 | 0.00 | 01-JAN-00:40 | 12984.62 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_STUDIO_2_F2 ZN | 119.75 | 0.00 | 01-JAN-00:10 | 12723.58 | 22-MAY-06:30 |
| Heating:EnergyTransfer:Zone:CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDIO_2_F2 ZN | 119.75 | 0.00 | 01-JAN-00:10 | 12723.58 | 22-MAY-06:30 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDIO_2_F2 ZN | 119.75 | 0.00 | 01-JAN-00:10 | 12723.58 | 22-MAY-06:30 |
| EnergyTransfer:Zone:CB_STUDIO_2_F3 ZN | 127.97 | 0.00 | 01-JAN-00:40 | 14313.59 | 22-MAY-06:10 |
| Heating:EnergyTransfer:Zone:CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_STUDIO_2_F3 ZN | 127.97 | 0.00 | 01-JAN-00:40 | 14313.59 | 22-MAY-06:10 |
| General:Cooling:EnergyTransfer:Zone:CB_STUDIO_2_F3 ZN | 127.97 | 0.00 | 01-JAN-00:40 | 14313.59 | 22-MAY-06:10 |
| EnergyTransfer:Zone:CB_UTILITY_F1 ZN | 3.01 | 0.00 | 01-JAN-00:40 | 568.13 | 02-JAN-15:00 |
| Heating:EnergyTransfer:Zone:CB_UTILITY_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_UTILITY_F1 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_UTILITY_F1 ZN | 3.01 | 0.00 | 01-JAN-00:40 | 568.13 | 02-JAN-15:00 |
| General:Cooling:EnergyTransfer:Zone:CB_UTILITY_F1 ZN | 3.01 | 0.00 | 01-JAN-00:40 | 568.13 | 02-JAN-15:00 |
| EnergyTransfer:Zone:CB_UTILITY_F2 ZN | 0.35 | 0.00 | 01-JAN-00:10 | 54.50 | 01-JAN-23:10 |
| Heating:EnergyTransfer:Zone:CB_UTILITY_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_UTILITY_F2 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_UTILITY_F2 ZN | 0.35 | 0.00 | 01-JAN-00:10 | 54.50 | 01-JAN-23:10 |
| General:Cooling:EnergyTransfer:Zone:CB_UTILITY_F2 ZN | 0.35 | 0.00 | 01-JAN-00:10 | 54.50 | 01-JAN-23:10 |
| EnergyTransfer:Zone:CB_UTILITY_F3 ZN | 0.33 | 0.00 | 01-JAN-00:40 | 60.55 | 02-JAN-00:40 |
| Heating:EnergyTransfer:Zone:CB_UTILITY_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_UTILITY_F3 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_UTILITY_F3 ZN | 0.33 | 0.00 | 01-JAN-00:40 | 60.55 | 02-JAN-00:40 |
| General:Cooling:EnergyTransfer:Zone:CB_UTILITY_F3 ZN | 0.33 | 0.00 | 01-JAN-00:40 | 60.55 | 02-JAN-00:40 |
| EnergyTransfer:Zone:CB_UTILITY_F4 ZN | 0.45 | 0.00 | 01-JAN-00:40 | 110.45 | 08-JAN-15:40 |
| Heating:EnergyTransfer:Zone:CB_UTILITY_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| General:Heating:EnergyTransfer:Zone:CB_UTILITY_F4 ZN | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
| Cooling:EnergyTransfer:Zone:CB_UTILITY_F4 ZN | 0.45 | 0.00 | 01-JAN-00:40 | 110.45 | 08-JAN-15:40 |
| General:Cooling:EnergyTransfer:Zone:CB_UTILITY_F4 ZN | 0.45 | 0.00 | 01-JAN-00:40 | 110.45 | 08-JAN-15:40 |
| PlantLoopHeatingDemand:Facility | 28.11 | 0.00 | 01-JAN-00:10 | 4964.71 | 13-JAN-13:10 |
| PlantLoopHeatingDemand:Plant | 28.11 | 0.00 | 01-JAN-00:10 | 4964.71 | 13-JAN-13:10 |
| WaterSystems:PlantLoopHeatingDemand | 28.11 | 0.00 | 01-JAN-00:10 | 4964.71 | 13-JAN-13:10 |
| General:WaterSystems:PlantLoopHeatingDemand | 28.11 | 0.00 | 01-JAN-00:10 | 4964.71 | 13-JAN-13:10 |
| EnergyTransfer:HVAC | 4386.26 | 0.00 | 02-JAN-21:10 | 438964.05 | 26-JAN-08:10 |
| HeatingCoils:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 1.69 | 18-SEP-17:20 |
| PlantLoopHeatingDemand:HVAC | 0.00 | 0.00 | 01-JAN-00:10 | 1.69 | 18-SEP-17:20 |
| HeatingCoils:PlantLoopHeatingDemand | 0.00 | 0.00 | 01-JAN-00:10 | 1.69 | 18-SEP-17:20 |
| CoolingCoils:EnergyTransfer | 4386.26 | 0.00 | 02-JAN-21:10 | 438964.05 | 26-JAN-08:10 |
| EnergyTransfer:Plant | 9942.11 | 0.00 | 02-JAN-21:10 | 925335.13 | 20-MAR-12:40 |
| Chillers:EnergyTransfer | 4454.55 | 0.00 | 02-JAN-21:10 | 427126.69 | 02-JAN-09:10 |
| HeatRejection:EnergyTransfer | 5459.46 | 0.00 | 02-JAN-21:10 | 493724.12 | 08-MAY-10:10 |
| General:HeatRejection:EnergyTransfer | 5459.46 | 0.00 | 02-JAN-21:10 | 493724.12 | 08-MAY-10:10 |
| WaterSystems:EnergyTransfer | 28.11 | 0.00 | 01-JAN-00:10 | 4964.71 | 13-JAN-13:10 |
| General:WaterSystems:EnergyTransfer | 28.11 | 0.00 | 01-JAN-00:10 | 4964.71 | 13-JAN-13:10 |
| Boilers:EnergyTransfer | 0.00 | 0.00 | 01-JAN-00:10 | 0.00 | 01-JAN-00:10 |
Report: Sensible Heat Gain Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Annual Building Sensible Heat Gain Components| HVAC Zone Eq & Other Sensible Air Heating [GJ] | HVAC Zone Eq & Other Sensible Air Cooling [GJ] | HVAC Terminal Unit Sensible Air Heating [GJ] | HVAC Terminal Unit Sensible Air Cooling [GJ] | HVAC Input Heated Surface Heating [GJ] | HVAC Input Cooled Surface Cooling [GJ] | People Sensible Heat Addition [GJ] | Lights Sensible Heat Addition [GJ] | Equipment Sensible Heat Addition [GJ] | Window Heat Addition [GJ] | Interzone Air Transfer Heat Addition [GJ] | Infiltration Heat Addition [GJ] | Opaque Surface Conduction and Other Heat Addition [GJ] | Equipment Sensible Heat Removal [GJ] | Window Heat Removal [GJ] | Interzone Air Transfer Heat Removal [GJ] | Infiltration Heat Removal [GJ] | Opaque Surface Conduction and Other Heat Removal [GJ] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.000 | 0.000 | 0.000 | -224.664 | 0.000 | 0.000 | 19.494 | 16.066 | 229.152 | 21.227 | 0.000 | 0.215 | 0.000 | 0.000 | -6.694 | 0.000 | -0.265 | -54.531 |
| CB_CLASSROOM_1_F2 ZN | 0.000 | 0.000 | 0.000 | -34.671 | 0.000 | 0.000 | 9.241 | 6.070 | 9.348 | 13.036 | 0.000 | 0.207 | 0.000 | 0.000 | -2.488 | 0.000 | -0.104 | -0.638 |
| CB_CLASSROOM_1_F3 ZN | 0.000 | 0.000 | 0.000 | -35.171 | 0.000 | 0.000 | 9.234 | 6.070 | 9.348 | 12.993 | 0.000 | 0.239 | 0.017 | 0.000 | -2.598 | 0.000 | -0.131 | -0.000 |
| CB_CLASSROOM_1_F4 ZN | 0.000 | 0.000 | 0.000 | -46.202 | 0.000 | 0.000 | 12.391 | 8.093 | 12.463 | 14.446 | 0.000 | 0.304 | 1.670 | 0.000 | -2.994 | 0.000 | -0.170 | -0.000 |
| CB_CLASSROOM_2_F2 ZN | 0.000 | 0.000 | 0.000 | -29.775 | 0.000 | 0.000 | 9.143 | 6.070 | 9.348 | 5.366 | 0.000 | 0.100 | 0.946 | 0.000 | -1.150 | 0.000 | -0.046 | -0.000 |
| CB_CLASSROOM_2_F3 ZN | 0.000 | 0.000 | 0.000 | -30.070 | 0.000 | 0.000 | 9.131 | 6.070 | 9.348 | 5.348 | 0.000 | 0.115 | 1.318 | 0.000 | -1.199 | 0.000 | -0.059 | -0.000 |
| CB_CLASSROOM_2_F4 ZN | 0.000 | 0.000 | 0.000 | -40.258 | 0.000 | 0.000 | 12.329 | 8.093 | 12.463 | 7.079 | 0.000 | 0.165 | 1.788 | 0.000 | -1.569 | 0.000 | -0.090 | -0.000 |
| CB_CLASSROOM_3_F2 ZN | 0.000 | 0.000 | 0.000 | -29.713 | 0.000 | 0.000 | 9.143 | 6.070 | 9.348 | 5.376 | 0.000 | 0.101 | 0.874 | 0.000 | -1.151 | 0.000 | -0.046 | -0.000 |
| CB_CLASSROOM_3_F3 ZN | 0.000 | 0.000 | 0.000 | -29.625 | 0.000 | 0.000 | 9.112 | 6.070 | 9.348 | 5.365 | 0.000 | 0.116 | 0.854 | 0.000 | -1.182 | 0.000 | -0.058 | -0.000 |
| CB_CLASSROOM_3_F4 ZN | 0.000 | 0.000 | 0.000 | -39.236 | 0.000 | 0.000 | 12.321 | 8.093 | 12.463 | 7.108 | 0.000 | 0.167 | 0.690 | 0.000 | -1.518 | 0.000 | -0.087 | -0.000 |
| CB_CLASSROOM_4_F2 ZN | 0.000 | 0.000 | 0.000 | -32.088 | 0.000 | 0.000 | 9.190 | 6.070 | 9.348 | 5.325 | 0.000 | 0.099 | 3.307 | 0.000 | -1.201 | 0.000 | -0.048 | -0.000 |
| CB_CLASSROOM_4_F3 ZN | 0.000 | 0.000 | 0.000 | -30.093 | 0.000 | 0.000 | 9.104 | 6.070 | 9.348 | 5.356 | 0.000 | 0.117 | 1.334 | 0.000 | -1.177 | 0.000 | -0.057 | -0.000 |
| CB_CLASSROOM_4_F4 ZN | 0.000 | 0.000 | 0.000 | -40.539 | 0.000 | 0.000 | 12.316 | 8.093 | 12.463 | 7.063 | 0.000 | 0.165 | 2.081 | 0.000 | -1.554 | 0.000 | -0.089 | -0.001 |
| CB_CLASSROOM_5_F2 ZN | 0.000 | 0.000 | 0.000 | -28.323 | 0.000 | 0.000 | 9.105 | 6.070 | 9.348 | 5.414 | 0.000 | 0.105 | 0.000 | 0.000 | -1.076 | 0.000 | -0.042 | -0.600 |
| CB_CLASSROOM_5_F3 ZN | 0.000 | 0.000 | 0.000 | -28.605 | 0.000 | 0.000 | 9.094 | 6.070 | 9.348 | 5.402 | 0.000 | 0.120 | 0.000 | 0.000 | -1.119 | 0.000 | -0.053 | -0.256 |
| CB_CLASSROOM_5_F4 ZN | 0.000 | 0.000 | 0.000 | -40.274 | 0.000 | 0.000 | 12.327 | 8.093 | 12.463 | 7.077 | 0.000 | 0.164 | 1.806 | 0.000 | -1.568 | 0.000 | -0.090 | -0.000 |
| CB_CLASSROOM_6_F2 ZN | 0.000 | 0.000 | 0.000 | -31.199 | 0.000 | 0.000 | 9.107 | 6.070 | 9.348 | 5.273 | 0.000 | 0.096 | 2.593 | 0.000 | -1.237 | 0.000 | -0.051 | -0.000 |
| CB_CLASSROOM_6_F3 ZN | 0.000 | 0.000 | 0.000 | -29.705 | 0.000 | 0.000 | 9.108 | 6.070 | 9.348 | 5.359 | 0.000 | 0.116 | 0.950 | 0.000 | -1.189 | 0.000 | -0.058 | -0.000 |
| CB_CLASSROOM_6_F4 ZN | 0.000 | 0.000 | 0.000 | -46.192 | 0.000 | 0.000 | 12.364 | 8.093 | 12.463 | 14.610 | 0.000 | 0.303 | 1.462 | 0.000 | -2.932 | 0.000 | -0.171 | -0.000 |
| CB_CLASSROOM_7_F2 ZN | 0.000 | 0.000 | 0.000 | -33.006 | 0.000 | 0.000 | 9.124 | 6.070 | 9.348 | 5.201 | 0.000 | 0.093 | 4.553 | 0.000 | -1.326 | 0.000 | -0.056 | -0.000 |
| CB_CLASSROOM_7_F3 ZN | 0.000 | 0.000 | 0.000 | -30.495 | 0.000 | 0.000 | 9.133 | 6.070 | 9.348 | 5.333 | 0.000 | 0.114 | 1.789 | 0.000 | -1.230 | 0.000 | -0.061 | -0.000 |
| CB_CLASSROOM_8_F2 ZN | 0.000 | 0.000 | 0.000 | -38.348 | 0.000 | 0.000 | 9.270 | 6.070 | 9.348 | 12.655 | 0.000 | 0.199 | 3.888 | 0.000 | -2.956 | 0.000 | -0.126 | -0.000 |
| CB_CLASSROOM_8_F3 ZN | 0.000 | 0.000 | 0.000 | -35.737 | 0.000 | 0.000 | 9.275 | 6.070 | 9.348 | 12.830 | 0.000 | 0.241 | 0.832 | 0.000 | -2.722 | 0.000 | -0.136 | -0.000 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.000 | 0.000 | 0.000 | -41.304 | 0.000 | 0.000 | 10.964 | 6.757 | 8.199 | 0.000 | 0.000 | 0.000 | 15.384 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.000 | 0.000 | 0.000 | -21.415 | 0.000 | 0.000 | 7.238 | 4.505 | 5.466 | 0.000 | 0.000 | 0.000 | 4.207 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.000 | 0.000 | 0.000 | -21.689 | 0.000 | 0.000 | 7.195 | 4.505 | 5.466 | 0.000 | 0.000 | 0.000 | 4.524 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.000 | 0.000 | 0.000 | -27.603 | 0.000 | 0.000 | 7.294 | 4.505 | 5.466 | 0.000 | 0.000 | 0.000 | 10.338 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.000 | 0.000 | 0.000 | -20.378 | 0.000 | 0.000 | 3.410 | 0.000 | 4.964 | 7.318 | 0.000 | 0.113 | 5.890 | 0.000 | -1.291 | 0.000 | -0.025 | -0.000 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.000 | 0.000 | 0.000 | -6.449 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.647 | 0.000 | 0.049 | 0.345 | 0.000 | -0.507 | 0.000 | -0.017 | -0.000 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.000 | 0.000 | 0.000 | -6.653 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.613 | 0.000 | 0.056 | 0.626 | 0.000 | -0.549 | 0.000 | -0.024 | -0.000 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.000 | 0.000 | 0.000 | -7.260 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.560 | 0.000 | 0.058 | 1.327 | 0.000 | -0.589 | 0.000 | -0.030 | -0.000 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.000 | 0.000 | 0.000 | -6.331 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.649 | 0.000 | 0.050 | 0.208 | 0.000 | -0.492 | 0.000 | -0.016 | -0.000 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.000 | 0.000 | 0.000 | -6.475 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.628 | 0.000 | 0.057 | 0.408 | 0.000 | -0.526 | 0.000 | -0.022 | -0.000 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.000 | 0.000 | 0.000 | -6.832 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.600 | 0.000 | 0.061 | 0.783 | 0.000 | -0.520 | 0.000 | -0.024 | -0.000 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.000 | 0.000 | 0.000 | -6.304 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.644 | 0.000 | 0.050 | 0.182 | 0.000 | -0.487 | 0.000 | -0.016 | -0.000 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.000 | 0.000 | 0.000 | -6.437 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.630 | 0.000 | 0.057 | 0.361 | 0.000 | -0.520 | 0.000 | -0.022 | -0.000 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.000 | 0.000 | 0.000 | -6.763 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.607 | 0.000 | 0.061 | 0.690 | 0.000 | -0.505 | 0.000 | -0.023 | -0.000 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.000 | 0.000 | 0.000 | -6.296 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.639 | 0.000 | 0.050 | 0.177 | 0.000 | -0.485 | 0.000 | -0.016 | -0.000 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.000 | 0.000 | 0.000 | -6.429 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.632 | 0.000 | 0.057 | 0.350 | 0.000 | -0.519 | 0.000 | -0.022 | -0.000 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.000 | 0.000 | 0.000 | -6.751 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.609 | 0.000 | 0.061 | 0.673 | 0.000 | -0.502 | 0.000 | -0.023 | -0.000 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.000 | 0.000 | 0.000 | -6.296 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.638 | 0.000 | 0.050 | 0.177 | 0.000 | -0.485 | 0.000 | -0.016 | -0.000 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.000 | 0.000 | 0.000 | -6.429 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.633 | 0.000 | 0.057 | 0.350 | 0.000 | -0.519 | 0.000 | -0.022 | -0.000 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.000 | 0.000 | 0.000 | -6.751 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.609 | 0.000 | 0.061 | 0.672 | 0.000 | -0.502 | 0.000 | -0.023 | -0.000 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.000 | 0.000 | 0.000 | -6.303 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.646 | 0.000 | 0.050 | 0.178 | 0.000 | -0.487 | 0.000 | -0.016 | -0.000 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.000 | 0.000 | 0.000 | -6.436 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.631 | 0.000 | 0.057 | 0.359 | 0.000 | -0.520 | 0.000 | -0.022 | -0.000 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.000 | 0.000 | 0.000 | -6.763 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.608 | 0.000 | 0.061 | 0.689 | 0.000 | -0.505 | 0.000 | -0.023 | -0.000 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.000 | 0.000 | 0.000 | -6.318 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.641 | 0.000 | 0.050 | 0.201 | 0.000 | -0.489 | 0.000 | -0.016 | -0.000 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.000 | 0.000 | 0.000 | -6.468 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.628 | 0.000 | 0.057 | 0.400 | 0.000 | -0.525 | 0.000 | -0.022 | -0.000 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.000 | 0.000 | 0.000 | -6.829 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.602 | 0.000 | 0.061 | 0.777 | 0.000 | -0.520 | 0.000 | -0.024 | -0.000 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.000 | 0.000 | 0.000 | -6.403 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.641 | 0.000 | 0.050 | 0.300 | 0.000 | -0.502 | 0.000 | -0.017 | -0.000 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.000 | 0.000 | 0.000 | -6.615 | 0.000 | 0.000 | 0.370 | 1.375 | 2.186 | 2.616 | 0.000 | 0.056 | 0.583 | 0.000 | -0.546 | 0.000 | -0.024 | -0.000 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.000 | 0.000 | 0.000 | -7.237 | 0.000 | 0.000 | 0.372 | 1.375 | 2.186 | 2.574 | 0.000 | 0.058 | 1.290 | 0.000 | -0.588 | 0.000 | -0.029 | -0.000 |
| CB_LAB_1_F4 ZN | 0.000 | 0.000 | 0.000 | -128.624 | 0.000 | 0.000 | 6.065 | 27.232 | 96.396 | 19.942 | 0.000 | 0.372 | 0.001 | 0.000 | -6.020 | 0.000 | -0.437 | -14.925 |
| CB_LAB_2_F4 ZN | 0.000 | 0.000 | 0.000 | -116.107 | 0.000 | 0.000 | 6.052 | 27.232 | 96.396 | 6.914 | 0.000 | 0.143 | 0.000 | 0.000 | -2.254 | 0.000 | -0.164 | -18.212 |
| CB_LAB_3_F4 ZN | 0.000 | 0.000 | 0.000 | -118.838 | 0.000 | 0.000 | 6.049 | 27.232 | 96.396 | 6.878 | 0.000 | 0.143 | 0.000 | 0.000 | -2.297 | 0.000 | -0.166 | -15.396 |
| CB_LAB_4_F4 ZN | 0.000 | 0.000 | 0.000 | -129.720 | 0.000 | 0.000 | 6.062 | 27.232 | 96.396 | 20.223 | 0.000 | 0.372 | 0.000 | 0.000 | -5.949 | 0.000 | -0.436 | -14.182 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.000 | 0.000 | 0.000 | -121.459 | 0.000 | 0.000 | 28.541 | 24.980 | 44.776 | 29.270 | 0.000 | 0.377 | 0.000 | 0.000 | -4.793 | 0.000 | -0.107 | -1.584 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.000 | 0.000 | 0.000 | -80.731 | 0.000 | 0.000 | 24.465 | 16.186 | 24.927 | 22.562 | 0.000 | 0.286 | 0.000 | 0.000 | -4.012 | 0.000 | -0.100 | -3.581 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.000 | 0.000 | 0.000 | -122.567 | 0.000 | 0.000 | 4.412 | 33.989 | 44.824 | 29.315 | 0.000 | 0.462 | 13.760 | 0.000 | -4.147 | 0.000 | -0.048 | -0.000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.000 | 0.000 | 0.000 | -6.573 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.725 | 0.000 | 0.041 | 0.294 | 0.000 | -0.413 | 0.000 | -0.006 | -0.000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.000 | 0.000 | 0.000 | -6.440 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.738 | 0.000 | 0.042 | 0.131 | 0.000 | -0.397 | 0.000 | -0.005 | -0.000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.000 | 0.000 | 0.000 | -6.414 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.739 | 0.000 | 0.042 | 0.100 | 0.000 | -0.394 | 0.000 | -0.005 | -0.000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.000 | 0.000 | 0.000 | -6.409 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.740 | 0.000 | 0.042 | 0.093 | 0.000 | -0.393 | 0.000 | -0.005 | -0.000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.000 | 0.000 | 0.000 | -6.408 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.740 | 0.000 | 0.042 | 0.093 | 0.000 | -0.393 | 0.000 | -0.005 | -0.000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.000 | 0.000 | 0.000 | -6.410 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.738 | 0.000 | 0.042 | 0.096 | 0.000 | -0.393 | 0.000 | -0.005 | -0.000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.000 | 0.000 | 0.000 | -6.421 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.739 | 0.000 | 0.042 | 0.108 | 0.000 | -0.395 | 0.000 | -0.005 | -0.000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.000 | 0.000 | 0.000 | -6.464 | 0.000 | 0.000 | 0.371 | 1.375 | 2.186 | 2.728 | 0.000 | 0.042 | 0.168 | 0.000 | -0.400 | 0.000 | -0.006 | -0.000 |
| CB_OFFICES_OPEN_F1 ZN | 0.000 | 0.000 | 0.000 | -66.083 | 0.000 | 0.000 | 5.639 | 21.764 | 34.616 | 0.000 | 0.000 | 0.000 | 4.063 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_OFFICES_OPEN_F2 ZN | 0.000 | 0.000 | 0.000 | -66.574 | 0.000 | 0.000 | 6.055 | 23.482 | 37.349 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -0.312 |
| CB_OFFICES_OPEN_F3 ZN | 0.000 | 0.000 | 0.000 | -67.909 | 0.000 | 0.000 | 6.021 | 23.482 | 37.349 | 0.000 | 0.000 | 0.000 | 1.056 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_OFFICES_OPEN_F4 ZN | 0.000 | 0.000 | 0.000 | -78.238 | 0.000 | 0.000 | 6.262 | 23.482 | 37.349 | 0.000 | 0.000 | 0.000 | 11.143 | 0.000 | 0.000 | 0.000 | 0.000 | -0.001 |
| CB_STUDIO_1_F2 ZN | 0.000 | 0.000 | 0.000 | -119.745 | 0.000 | 0.000 | 12.710 | 32.222 | 49.623 | 28.357 | 0.000 | 0.484 | 2.078 | 0.000 | -5.511 | 0.000 | -0.219 | -0.002 |
| CB_STUDIO_1_F3 ZN | 0.000 | 0.000 | 0.000 | -128.249 | 0.000 | 0.000 | 12.538 | 32.222 | 49.623 | 27.978 | 0.000 | 0.522 | 11.850 | 0.000 | -6.168 | 0.000 | -0.315 | -0.001 |
| CB_STUDIO_2_F2 ZN | 0.000 | 0.000 | 0.000 | -119.753 | 0.000 | 0.000 | 12.579 | 32.222 | 49.623 | 28.543 | 0.000 | 0.475 | 2.025 | 0.000 | -5.493 | 0.000 | -0.221 | -0.001 |
| CB_STUDIO_2_F3 ZN | 0.000 | 0.000 | 0.000 | -127.970 | 0.000 | 0.000 | 12.682 | 32.222 | 49.623 | 27.876 | 0.000 | 0.537 | 11.483 | 0.000 | -6.143 | 0.000 | -0.311 | -0.000 |
| CB_CORRIDOR_1_F3 ZN | 0.000 | 0.000 | 0.000 | -8.542 | 0.000 | 0.000 | 0.000 | 1.962 | 2.084 | 2.388 | 0.000 | 0.057 | 2.519 | 0.000 | -0.452 | 0.000 | -0.017 | -0.000 |
| CB_CORRIDOR_2_F3 ZN | 0.000 | 0.000 | 0.000 | -13.005 | 0.000 | 0.000 | 0.000 | 3.808 | 4.045 | 0.000 | 0.000 | 0.000 | 5.152 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_CORRIDOR_F1 ZN | 0.000 | 0.000 | 0.000 | -53.024 | 0.000 | 0.000 | 0.000 | 7.587 | 8.059 | 2.434 | 0.000 | 0.043 | 35.316 | 0.000 | -0.408 | 0.000 | -0.006 | -0.000 |
| CB_CORRIDOR_F2 ZN | 0.000 | 0.000 | 0.000 | -24.775 | 0.000 | 0.000 | 0.000 | 5.770 | 6.128 | 2.396 | 0.000 | 0.053 | 10.889 | 0.000 | -0.448 | 0.000 | -0.013 | -0.000 |
| CB_CORRIDOR_F4 ZN | 0.000 | 0.000 | 0.000 | -46.517 | 0.000 | 0.000 | 0.000 | 9.405 | 9.989 | 2.362 | 0.000 | 0.059 | 25.228 | 0.000 | -0.503 | 0.000 | -0.024 | -0.000 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.000 | 0.000 | 0.000 | -0.038 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.571 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.000 | 0.000 | 0.000 | -0.041 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.567 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.000 | 0.000 | 0.000 | -0.079 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.529 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.000 | 0.000 | 0.000 | -0.037 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.571 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.000 | 0.000 | 0.000 | -0.043 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.565 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.000 | 0.000 | 0.000 | -0.079 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.529 |
| CB_MAIN_STAIRS_F1 ZN | 0.000 | 0.000 | 0.000 | -5.395 | 0.000 | 0.000 | 0.000 | 1.379 | 0.000 | 2.476 | 0.000 | 0.043 | 1.854 | 0.000 | -0.352 | 0.000 | -0.005 | -0.000 |
| CB_MAIN_STAIRS_F2 ZN | 0.000 | 0.000 | 0.000 | -4.949 | 0.000 | 0.000 | 0.000 | 1.379 | 0.000 | 2.395 | 0.000 | 0.052 | 1.538 | 0.000 | -0.404 | 0.000 | -0.011 | -0.000 |
| CB_MAIN_STAIRS_F3 ZN | 0.000 | 0.000 | 0.000 | -4.944 | 0.000 | 0.000 | 0.000 | 1.379 | 0.000 | 2.404 | 0.000 | 0.059 | 1.544 | 0.000 | -0.425 | 0.000 | -0.015 | -0.000 |
| CB_MAIN_STAIRS_F4 ZN | 0.000 | 0.000 | 0.000 | -5.737 | 0.000 | 0.000 | 0.000 | 1.379 | 0.000 | 2.365 | 0.000 | 0.062 | 2.379 | 0.000 | -0.428 | 0.000 | -0.019 | 0.000 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.000 | 0.000 | 0.000 | -6.598 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.092 | 0.000 | 0.024 | 3.955 | 0.000 | -0.395 | 0.000 | -0.008 | 0.000 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.000 | 0.000 | 0.000 | -5.190 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.105 | 0.000 | 0.036 | 2.488 | 0.000 | -0.358 | 0.000 | -0.012 | 0.000 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.000 | 0.000 | 0.000 | -5.198 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.139 | 0.000 | 0.041 | 2.476 | 0.000 | -0.374 | 0.000 | -0.015 | 0.000 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.000 | 0.000 | 0.000 | -5.762 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.054 | 0.000 | 0.041 | 3.160 | 0.000 | -0.404 | 0.000 | -0.020 | 0.000 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.000 | 0.000 | 0.000 | -5.071 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.270 | 0.000 | 0.030 | 2.122 | 0.000 | -0.278 | 0.000 | -0.004 | -0.000 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.000 | 0.000 | 0.000 | -4.982 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.189 | 0.000 | 0.036 | 2.164 | 0.000 | -0.327 | 0.000 | -0.010 | 0.000 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.000 | 0.000 | 0.000 | -5.207 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.183 | 0.000 | 0.041 | 2.428 | 0.000 | -0.361 | 0.000 | -0.015 | 0.000 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.000 | 0.000 | 0.000 | -5.851 | 0.000 | 0.000 | 0.000 | 0.931 | 0.000 | 2.139 | 0.000 | 0.041 | 3.160 | 0.000 | -0.399 | 0.000 | -0.020 | 0.000 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.000 | 0.000 | 0.000 | -0.052 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.556 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.000 | 0.000 | 0.000 | -0.058 | 0.000 | 0.000 | 0.000 | 0.951 | 0.657 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -1.550 |
| CB_STORAGE_F1 ZN | 0.000 | 0.000 | 0.000 | -42.515 | 0.000 | 0.000 | 0.000 | 4.331 | 0.000 | 6.970 | 0.000 | 0.090 | 32.868 | 0.000 | -1.697 | 0.000 | -0.047 | 0.000 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.000 | 0.000 | 0.000 | -0.105 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2.988 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.000 | 0.000 | 0.000 | -0.073 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -3.020 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.000 | 0.000 | 0.000 | -0.129 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2.964 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.000 | 0.000 | 0.000 | -0.199 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2.894 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.000 | 0.000 | 0.000 | -0.114 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2.978 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.000 | 0.000 | 0.000 | -0.078 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -3.014 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.000 | 0.000 | 0.000 | -0.123 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2.970 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.000 | 0.000 | 0.000 | -0.265 | 0.000 | 0.000 | 0.000 | 1.829 | 1.264 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -2.827 |
| CB_UTILITY_F1 ZN | 0.000 | 0.000 | 0.000 | -3.007 | 0.000 | 0.000 | 0.000 | 0.532 | 0.539 | 0.000 | 0.000 | 0.000 | 1.936 | 0.000 | 0.000 | 0.000 | 0.000 | -0.000 |
| CB_UTILITY_F2 ZN | 0.000 | 0.000 | 0.000 | -0.349 | 0.000 | 0.000 | 0.000 | 0.532 | 0.539 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -0.722 |
| CB_UTILITY_F3 ZN | 0.000 | 0.000 | 0.000 | -0.328 | 0.000 | 0.000 | 0.000 | 0.532 | 0.539 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -0.744 |
| CB_UTILITY_F4 ZN | 0.000 | 0.000 | 0.000 | -0.449 | 0.000 | 0.000 | 0.000 | 0.532 | 0.539 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | -0.623 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 73.119 | 0.468 | 0.000 | 0.001 | 0.000 | 0.000 | -2.252 | 0.000 | -0.146 | -71.189 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.415 | 0.000 | 0.006 | 0.000 | 0.000 | -0.677 | 0.000 | -0.033 | -0.711 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.691 | 0.000 | 0.022 | 0.000 | 0.000 | -0.447 | 0.000 | -0.019 | -1.248 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 0.000 | 1.655 | 0.000 | 0.022 | 0.000 | 0.000 | -0.393 | 0.000 | -0.022 | -1.262 |
| Total Facility | 0.000 | 0.000 | 0.000 | -3177.217 | 0.000 | 0.000 | 444.161 | 701.370 | 1519.231 | 582.817 | 0.000 | 10.476 | 286.924 | 0.000 | -125.265 | 0.000 | -5.684 | -236.817 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 19-NOV-10:39 | 0.00 | 0.00 | 0.00 | -30527.38 | 0.00 | 0.00 | 0.00 | 202.41 | 5534.10 | 1886.76 | 0.00 | 0.00 | 22915.37 | 0.00 | -0.00 | 0.00 | -11.26 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 22-OCT-10:50 | 0.00 | 0.00 | 0.00 | -5937.69 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 1815.40 | 0.00 | 0.77 | 3819.30 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 29-JAN-10:30 | 0.00 | 0.00 | 0.00 | -5956.41 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 2330.46 | 0.00 | 0.00 | 3354.76 | 0.00 | -0.00 | 0.00 | -31.04 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 11-MAR-17:00 | 0.00 | 0.00 | 0.00 | -8639.66 | 0.00 | 0.00 | 0.00 | 101.97 | 301.00 | 1339.25 | 0.00 | 5.98 | 6891.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 08-JAN-13:20 | 0.00 | 0.00 | 0.00 | -4303.15 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 1055.26 | 0.00 | 9.28 | 2936.40 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 29-JAN-13:50 | 0.00 | 0.00 | 0.00 | -4235.28 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 855.81 | 0.00 | 5.10 | 3072.14 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 29-JAN-12:39 | 0.00 | 0.00 | 0.00 | -5992.49 | 0.00 | 0.00 | 0.00 | 101.97 | 301.00 | 1093.25 | 0.00 | 0.00 | 4502.16 | 0.00 | -0.00 | 0.00 | -5.88 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 08-JAN-13:20 | 0.00 | 0.00 | 0.00 | -4285.15 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 1057.40 | 0.00 | 9.68 | 2915.85 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 29-JAN-17:10 | 0.00 | 0.00 | 0.00 | -3938.59 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 501.74 | 0.00 | 0.52 | 3134.12 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 29-JAN-12:39 | 0.00 | 0.00 | 0.00 | -5825.52 | 0.00 | 0.00 | 0.00 | 101.97 | 301.00 | 1095.24 | 0.00 | 0.00 | 4332.82 | 0.00 | -0.00 | 0.00 | -5.49 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 08-JAN-13:20 | 0.00 | 0.00 | 0.00 | -4750.99 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 1056.55 | 0.00 | 10.85 | 3381.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 29-JAN-17:10 | 0.00 | 0.00 | 0.00 | -3959.42 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 503.63 | 0.00 | 1.15 | 3152.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 29-JAN-12:39 | 0.00 | 0.00 | 0.00 | -5962.10 | 0.00 | 0.00 | 0.00 | 101.97 | 301.00 | 1092.38 | 0.00 | 0.00 | 4472.66 | 0.00 | -0.00 | 0.00 | -5.90 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 08-JAN-13:20 | 0.00 | 0.00 | 0.00 | -4003.18 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 1061.63 | 0.00 | 10.53 | 2628.79 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 29-JAN-17:10 | 0.00 | 0.00 | 0.00 | -3778.70 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 505.76 | 0.00 | 1.41 | 2969.31 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 29-JAN-12:39 | 0.00 | 0.00 | 0.00 | -5997.07 | 0.00 | 0.00 | 0.00 | 101.97 | 301.00 | 1092.05 | 0.00 | 0.00 | 4508.37 | 0.00 | -0.00 | 0.00 | -6.31 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 29-JAN-13:20 | 0.00 | 0.00 | 0.00 | -4435.38 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 851.08 | 0.00 | 1.80 | 3280.28 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 29-JAN-13:50 | 0.00 | 0.00 | 0.00 | -3956.32 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 858.52 | 0.00 | 5.14 | 2790.44 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 22-OCT-10:39 | 0.00 | 0.00 | 0.00 | -7660.73 | 0.00 | 0.00 | 0.00 | 101.97 | 301.00 | 2002.38 | 0.00 | 0.00 | 5255.80 | 0.00 | -0.00 | 0.00 | -0.41 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 29-JAN-13:20 | 0.00 | 0.00 | 0.00 | -4692.49 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 842.88 | 0.00 | 0.96 | 3546.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 29-JAN-13:50 | 0.00 | 0.00 | 0.00 | -4274.44 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 855.48 | 0.00 | 5.10 | 3111.64 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 29-JAN-16:40 | 0.00 | 0.00 | 0.00 | -6810.06 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 2287.48 | 0.00 | 0.00 | 4235.43 | 0.00 | -0.00 | 0.00 | -15.07 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 11-MAR-17:00 | 0.00 | 0.00 | 0.00 | -6417.71 | 0.00 | 0.00 | 0.00 | 76.47 | 225.75 | 1351.50 | 0.00 | 10.01 | 4753.98 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 18-MAY-07:19 | 0.00 | 0.00 | 0.00 | -2769.52 | 0.00 | 0.00 | 1786.35 | 432.13 | 495.00 | 0.00 | 0.00 | 0.00 | 56.04 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 03-MAR-08:16 | 0.00 | 0.00 | 0.00 | -1902.73 | 0.00 | 0.00 | 1167.40 | 288.09 | 330.00 | 0.00 | 0.00 | 0.00 | 117.24 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 10-MAY-07:19 | 0.00 | 0.00 | 0.00 | -1906.62 | 0.00 | 0.00 | 1138.78 | 288.09 | 330.00 | 0.00 | 0.00 | 0.00 | 149.76 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 16-JAN-13:09 | 0.00 | 0.00 | 0.00 | -2114.27 | 0.00 | 0.00 | 1057.24 | 288.09 | 330.00 | 0.00 | 0.00 | 0.00 | 438.95 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -2676.80 | 0.00 | 0.00 | 0.00 | 0.00 | 119.88 | 0.00 | 0.00 | 0.00 | 2777.11 | 0.00 | -220.19 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1082.64 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 443.86 | 0.00 | 11.56 | 557.10 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1067.69 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.07 | 0.00 | 3.49 | 603.02 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1250.33 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 412.85 | 0.00 | 1.18 | 779.37 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1088.13 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 441.21 | 0.00 | 11.36 | 565.45 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1066.19 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.55 | 0.00 | 3.58 | 600.95 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1222.45 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.02 | 0.00 | 1.10 | 749.41 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1087.35 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 439.83 | 0.00 | 11.34 | 566.06 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1064.42 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.54 | 0.00 | 3.62 | 599.14 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1220.17 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.37 | 0.00 | 1.08 | 746.80 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1086.54 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 438.96 | 0.00 | 11.34 | 566.13 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1064.13 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.80 | 0.00 | 3.64 | 598.58 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1219.67 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.50 | 0.00 | 1.09 | 746.16 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1086.41 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 438.76 | 0.00 | 11.34 | 566.18 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1064.28 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 392.00 | 0.00 | 3.64 | 598.53 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1219.78 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.60 | 0.00 | 1.09 | 746.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1087.55 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 440.22 | 0.00 | 11.34 | 565.88 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1064.49 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.80 | 0.00 | 3.63 | 598.94 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1220.25 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.46 | 0.00 | 1.08 | 746.79 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1086.81 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 439.78 | 0.00 | 11.36 | 565.54 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1065.47 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.59 | 0.00 | 3.60 | 600.16 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1222.63 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.18 | 0.00 | 1.10 | 749.43 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 10-JUN-15:39 | 0.00 | 0.00 | 0.00 | -1082.78 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 441.86 | 0.00 | 11.56 | 559.25 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 18-JUN-12:09 | 0.00 | 0.00 | 0.00 | -1067.26 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 391.64 | 0.00 | 3.58 | 601.91 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 08-JUL-12:39 | 0.00 | 0.00 | 0.00 | -1250.92 | 0.00 | 0.00 | 0.00 | 17.32 | 39.60 | 415.01 | 0.00 | 1.21 | 777.78 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 05-AUG-16:40 | 0.00 | 0.00 | 0.00 | -20840.08 | 0.00 | 0.00 | 0.00 | 343.10 | 1746.00 | 3729.23 | 0.00 | 6.53 | 15015.23 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | 10-SEP-13:20 | 0.00 | 0.00 | 0.00 | -16104.47 | 0.00 | 0.00 | 0.00 | 343.10 | 2328.00 | 472.85 | 0.00 | 0.00 | 12989.16 | 0.00 | -0.00 | 0.00 | -28.65 | 0.00 |
| CB_LAB_3_F4 ZN | 10-SEP-13:20 | 0.00 | 0.00 | 0.00 | -16165.99 | 0.00 | 0.00 | 0.00 | 343.10 | 2328.00 | 468.88 | 0.00 | 0.00 | 13055.33 | 0.00 | -0.00 | 0.00 | -29.32 | 0.00 |
| CB_LAB_4_F4 ZN | 11-MAR-10:39 | 0.00 | 0.00 | 0.00 | -19845.47 | 0.00 | 0.00 | 0.00 | 343.10 | 2328.00 | 3217.23 | 0.00 | 0.00 | 13972.77 | 0.00 | -0.00 | 0.00 | -15.64 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 22-MAY-05:10 | 0.00 | 0.00 | 0.00 | -18445.11 | 0.00 | 0.00 | 0.00 | 314.73 | 1081.36 | 0.00 | 0.00 | 0.00 | 17621.72 | 0.00 | -572.69 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 27-NOV-06:10 | 0.00 | 0.00 | 0.00 | -11124.21 | 0.00 | 0.00 | 0.00 | 203.93 | 601.99 | 0.00 | 0.00 | 0.00 | 10778.01 | 0.00 | -459.03 | 0.00 | -0.69 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -13035.99 | 0.00 | 0.00 | 0.00 | 428.23 | 1082.52 | 0.00 | 0.00 | 0.00 | 12252.58 | 0.00 | -727.34 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -811.19 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 814.57 | 0.00 | -73.50 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -799.07 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 800.71 | 0.00 | -71.76 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -796.63 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 797.84 | 0.00 | -71.32 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -796.14 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 797.25 | 0.00 | -71.24 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -796.02 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 797.11 | 0.00 | -71.20 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -796.19 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 797.30 | 0.00 | -71.22 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -797.21 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 798.56 | 0.00 | -71.47 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -800.15 | 0.00 | 0.00 | 0.00 | 17.32 | 52.80 | 0.00 | 0.00 | 0.00 | 802.07 | 0.00 | -72.04 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -7208.17 | 0.00 | 0.00 | 0.00 | 274.21 | 836.00 | 0.00 | 0.00 | 0.00 | 6097.96 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -7694.04 | 0.00 | 0.00 | 0.00 | 295.86 | 902.00 | 0.00 | 0.00 | 0.00 | 6496.18 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 02-JAN-00:40 | 0.00 | 0.00 | 0.00 | -7887.31 | 0.00 | 0.00 | 0.00 | 295.86 | 902.00 | 0.00 | 0.00 | 0.00 | 6689.45 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 12-JUN-05:11 | 0.00 | 0.00 | 0.00 | -9873.45 | 0.00 | 0.00 | 0.00 | 295.86 | 902.00 | 0.00 | 0.00 | 0.00 | 8675.59 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 17-SEP-16:00 | 0.00 | 0.00 | 0.00 | -18471.76 | 0.00 | 0.00 | 0.00 | 405.97 | 1198.41 | 3346.98 | 0.00 | 43.30 | 13477.10 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 09-JUL-11:09 | 0.00 | 0.00 | 0.00 | -17363.61 | 0.00 | 0.00 | 0.00 | 405.97 | 898.81 | 4711.21 | 0.00 | 3.80 | 11343.82 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 21-MAY-16:30 | 0.00 | 0.00 | 0.00 | -16156.52 | 0.00 | 0.00 | 0.00 | 405.97 | 1198.41 | 350.68 | 0.00 | 6.04 | 14195.41 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 16-APR-16:00 | 0.00 | 0.00 | 0.00 | -18713.84 | 0.00 | 0.00 | 0.00 | 405.97 | 1198.41 | 2958.06 | 0.00 | 6.81 | 14144.58 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -963.55 | 0.00 | 0.00 | 0.00 | 24.72 | 50.32 | 0.00 | 0.00 | 0.00 | 959.08 | 0.00 | -70.57 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 20-NOV-06:19 | 0.00 | 0.00 | 0.00 | -1364.40 | 0.00 | 0.00 | 0.00 | 47.98 | 97.68 | 0.00 | 0.00 | 0.00 | 1218.75 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -6985.79 | 0.00 | 0.00 | 0.00 | 95.59 | 194.62 | 0.00 | 0.00 | 0.00 | 6765.24 | 0.00 | -69.66 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -2765.96 | 0.00 | 0.00 | 0.00 | 72.69 | 148.00 | 0.00 | 0.00 | 0.00 | 2614.99 | 0.00 | -69.72 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 01-MAY-05:11 | 0.00 | 0.00 | 0.00 | -5671.56 | 0.00 | 0.00 | 0.00 | 118.49 | 241.24 | 0.00 | 0.00 | 0.00 | 5350.97 | 0.00 | -39.03 | 0.00 | -0.11 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | -226.22 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 198.36 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 02-JAN-04:19 | 0.00 | 0.00 | 0.00 | -215.45 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 187.60 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 21-MAY-16:40 | 0.00 | 0.00 | 0.00 | -221.33 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 193.47 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | -224.59 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 196.73 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 02-JAN-04:19 | 0.00 | 0.00 | 0.00 | -224.27 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 196.42 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 08-OCT-14:50 | 0.00 | 0.00 | 0.00 | -232.63 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 204.78 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 02-JAN-06:12 | 0.00 | 0.00 | 0.00 | -620.26 | 0.00 | 0.00 | 0.00 | 17.38 | 0.00 | 0.00 | 0.00 | 0.00 | 671.71 | 0.00 | -68.82 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 29-JAN-15:20 | 0.00 | 0.00 | 0.00 | -586.02 | 0.00 | 0.00 | 0.00 | 17.38 | 0.00 | 359.46 | 0.00 | 2.40 | 206.78 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 08-JAN-16:42 | 0.00 | 0.00 | 0.00 | -598.27 | 0.00 | 0.00 | 0.00 | 17.38 | 0.00 | 340.42 | 0.00 | 5.58 | 234.90 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 29-JAN-15:01 | 0.00 | 0.00 | 0.00 | -854.32 | 0.00 | 0.00 | 0.00 | 17.38 | 0.00 | 312.03 | 0.00 | 1.82 | 523.10 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 02-OCT-05:10 | 0.00 | 0.00 | 0.00 | -963.11 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 0.00 | 0.00 | 0.00 | 1000.74 | 0.00 | -49.33 | 0.00 | -0.03 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 17-SEP-16:00 | 0.00 | 0.00 | 0.00 | -1030.83 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 401.52 | 0.00 | 1.82 | 615.75 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 24-SEP-17:00 | 0.00 | 0.00 | 0.00 | -1038.72 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 210.12 | 0.00 | 0.00 | 818.15 | 0.00 | -0.00 | 0.00 | -1.28 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 11-MAR-17:00 | 0.00 | 0.00 | 0.00 | -1252.33 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 330.40 | 0.00 | 0.00 | 910.52 | 0.00 | -0.00 | 0.00 | -0.32 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -683.73 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 0.00 | 0.00 | 0.00 | 724.17 | 0.00 | -52.17 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 22-OCT-10:50 | 0.00 | 0.00 | 0.00 | -870.82 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 351.83 | 0.00 | 0.15 | 507.11 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 09-JUL-11:09 | 0.00 | 0.00 | 0.00 | -938.50 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 359.79 | 0.00 | 0.23 | 566.75 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 21-OCT-11:20 | 0.00 | 0.00 | 0.00 | -1133.72 | 0.00 | 0.00 | 0.00 | 11.73 | 0.00 | 309.93 | 0.00 | 1.26 | 810.81 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 02-JAN-01:30 | 0.00 | 0.00 | 0.00 | -194.65 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 166.80 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 02-JAN-01:30 | 0.00 | 0.00 | 0.00 | -196.02 | 0.00 | 0.00 | 0.00 | 11.98 | 15.87 | 0.00 | 0.00 | 0.00 | 168.17 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 11-DEC-06:10 | 0.00 | 0.00 | 0.00 | -6520.12 | 0.00 | 0.00 | 0.00 | 54.57 | 0.00 | 0.00 | 0.00 | 0.00 | 6746.93 | 0.00 | -279.83 | 0.00 | -1.55 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 02-JAN-01:30 | 0.00 | 0.00 | 0.00 | -395.74 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 342.18 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | -405.38 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 351.82 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 01-JAN-02:39 | 0.00 | 0.00 | 0.00 | -399.98 | 0.00 | 0.00 | 0.00 | 23.04 | 30.52 | 0.00 | 0.00 | 0.00 | 346.41 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 08-OCT-14:50 | 0.00 | 0.00 | 0.00 | -459.40 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 405.83 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 02-JAN-01:30 | 0.00 | 0.00 | 0.00 | -418.31 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 364.75 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 01-JAN-07:10 | 0.00 | 0.00 | 0.00 | -461.45 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 407.89 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 01-JAN-02:39 | 0.00 | 0.00 | 0.00 | -459.20 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 405.63 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 21-MAY-16:40 | 0.00 | 0.00 | 0.00 | -602.37 | 0.00 | 0.00 | 0.00 | 23.04 | 30.53 | 0.00 | 0.00 | 0.00 | 548.80 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 02-JAN-15:09 | 0.00 | 0.00 | 0.00 | -578.69 | 0.00 | 0.00 | 0.00 | 34.06 | 32.56 | 0.00 | 0.00 | 0.00 | 512.07 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 01-JAN-23:10 | 0.00 | 0.00 | 0.00 | -182.93 | 0.00 | 0.00 | 0.00 | 6.71 | 13.02 | 0.00 | 0.00 | 0.00 | 163.20 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 02-JAN-00:40 | 0.00 | 0.00 | 0.00 | -215.54 | 0.00 | 0.00 | 0.00 | 6.71 | 13.02 | 0.00 | 0.00 | 0.00 | 195.81 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 08-JAN-15:39 | 0.00 | 0.00 | 0.00 | -308.27 | 0.00 | 0.00 | 0.00 | 6.71 | 13.02 | 0.00 | 0.00 | 0.00 | 288.54 | 0.00 | -0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | 02-JAN-06:10 | 0.00 | 0.00 | 0.00 | -375521.25 | 0.00 | 0.00 | 0.00 | 8836.70 | 35050.77 | 0.00 | 0.00 | 0.00 | 348254.75 | 0.00 | -16620.97 | 0.00 | 0.00 | 0.00 |
| Time of Peak {TIMESTAMP} | HVAC Zone Eq & Other Sensible Air Heating [W] | HVAC Zone Eq & Other Sensible Air Cooling [W] | HVAC Terminal Unit Sensible Air Heating [W] | HVAC Terminal Unit Sensible Air Cooling [W] | HVAC Input Heated Surface Heating [W] | HVAC Input Cooled Surface Cooling [W] | People Sensible Heat Addition [W] | Lights Sensible Heat Addition [W] | Equipment Sensible Heat Addition [W] | Window Heat Addition [W] | Interzone Air Transfer Heat Addition [W] | Infiltration Heat Addition [W] | Opaque Surface Conduction and Other Heat Addition [W] | Equipment Sensible Heat Removal [W] | Window Heat Removal [W] | Interzone Air Transfer Heat Removal [W] | Infiltration Heat Removal [W] | Opaque Surface Conduction and Other Heat Removal [W] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_2_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_3_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_4_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Total Facility | - | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: Standard 62.1 Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
System Ventilation Requirements for Cooling| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow - Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| VAV_1 | 5.8347 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 5.6136 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
| VAV_2 | 4.8683 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.7943 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
| VAV_3 | 4.8232 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 4.7503 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
| VAV_4 | 7.1923 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 7.0244 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
| Sum of Zone Primary Air Flow - Vpz-sum [m3/s] | System Population - Ps | Sum of Zone Population - Pz-sum | Occupant Diversity - D | Origin of D | Uncorrected Outdoor Air Intake Airflow - Vou [m3/s] | System Primary Airflow - Vps [m3/s] | Average Outdoor Air Fraction - Xs | System Ventilation Efficiency - Ev | Calculation Method for Ev | Outdoor Air Intake Flow Vot [m3/s] | Percent Outdoor Air - %OA | Environment Name of Peak System Population - Ps | Date and Time of Last Peak System Population - Ps | |
| VAV_1 | 2.9421 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 0.3526 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
| VAV_2 | 2.4499 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 0.2026 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
| VAV_3 | 2.4273 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 0.2021 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 | ||
| VAV_4 | 3.6029 | 0.0000 | 0.0000 | 1.0000 | Calculated from schedules | 0.0000 | 0.2311 | 0.0000 | 1.0000 | Not calculated | 0.0000 | 0.0000 |
| AirLoop Name | People Outdoor Air Rate - Rp [m3/s-person] | Zone Population - Pz | Area Outdoor Air Rate - Ra [m3/s-m2] | Zone Floor Area - Az [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Air Distribution Effectiveness - Ez-clg | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Air Distribution Effectiveness - Ez-htg | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | VAV_1 | 0.000000 | 48.3750 | 0.000000 | 179.77 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_1_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_1_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_1_F4 ZN | VAV_4 | 0.000000 | 52.6500 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_2_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_2_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_2_F4 ZN | VAV_4 | 0.000000 | 52.6500 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_3_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_3_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_3_F4 ZN | VAV_4 | 0.000000 | 52.6500 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_4_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_4_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_4_F4 ZN | VAV_4 | 0.000000 | 52.6500 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_5_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_5_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_5_F4 ZN | VAV_4 | 0.000000 | 52.6500 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_6_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_6_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_6_F4 ZN | VAV_4 | 0.000000 | 52.6500 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_7_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_7_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_8_F2 ZN | VAV_2 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CLASSROOM_8_F3 ZN | VAV_3 | 0.000000 | 39.4875 | 0.000000 | 56.44 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CONFERENCE_ROOM_F1 ZN | VAV_1 | 0.003304 | 24.7500 | 0.000000 | 45.99 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CONFERENCE_ROOM_F2 ZN | VAV_2 | 0.003304 | 16.5000 | 0.000000 | 30.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CONFERENCE_ROOM_F3 ZN | VAV_3 | 0.003304 | 16.5000 | 0.000000 | 30.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CONFERENCE_ROOM_F4 ZN | VAV_4 | 0.003304 | 16.5000 | 0.000000 | 30.66 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_ENTRANCE_LOBBY_F1 ZN | VAV_1 | 0.000000 | 8.1000 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_1_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_1_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_1_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_2_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_2_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_2_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_3_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_3_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_3_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_4_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_4_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_4_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_5_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_5_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_5_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_6_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_6_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_6_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_7_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_7_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_7_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_8_F2 ZN | VAV_2 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_8_F3 ZN | VAV_3 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_OFFICE_8_F4 ZN | VAV_4 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LAB_1_F4 ZN | VAV_4 | 0.000000 | 36.3750 | 0.000000 | 135.17 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LAB_2_F4 ZN | VAV_4 | 0.000000 | 36.3750 | 0.000000 | 135.17 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LAB_3_F4 ZN | VAV_4 | 0.000000 | 36.3750 | 0.000000 | 135.17 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LAB_4_F4 ZN | VAV_4 | 0.000000 | 36.3750 | 0.000000 | 135.17 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LECTURE_ROOM_1_F1 ZN | VAV_1 | 0.000000 | 189.1500 | 0.000000 | 270.35 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LECTURE_ROOM_2_F1 ZN | VAV_1 | 0.000000 | 105.3000 | 0.000000 | 150.50 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | VAV_1 | 0.002360 | 29.1000 | 0.000000 | 270.35 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | VAV_1 | 0.002360 | 0.6600 | 0.000000 | 12.26 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_OPEN_F1 ZN | VAV_1 | 0.002360 | 10.4500 | 0.000000 | 194.17 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_OPEN_F2 ZN | VAV_2 | 0.002360 | 11.2750 | 0.000000 | 209.50 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_OPEN_F3 ZN | VAV_3 | 0.002360 | 11.2750 | 0.000000 | 209.50 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_OFFICES_OPEN_F4 ZN | VAV_4 | 0.002360 | 11.2750 | 0.000000 | 209.50 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDIO_1_F2 ZN | VAV_2 | 0.000000 | 64.5000 | 0.000000 | 299.61 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDIO_1_F3 ZN | VAV_3 | 0.000000 | 64.5000 | 0.000000 | 299.61 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDIO_2_F2 ZN | VAV_2 | 0.000000 | 64.5000 | 0.000000 | 299.61 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDIO_2_F3 ZN | VAV_3 | 0.000000 | 64.5000 | 0.000000 | 299.61 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CORRIDOR_1_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000102 | 31.59 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CORRIDOR_2_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000102 | 61.32 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CORRIDOR_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000102 | 122.17 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CORRIDOR_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000102 | 92.90 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_CORRIDOR_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000102 | 151.43 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_MAIN_STAIRS_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000102 | 18.58 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_MAIN_STAIRS_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000102 | 18.58 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_MAIN_STAIRS_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000102 | 18.58 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_MAIN_STAIRS_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000102 | 18.58 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_1_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_1_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_1_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_1_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_2_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_2_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_2_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_SECONDARY_STAIRS_2_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000102 | 12.54 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STAFF_RESTROOMS_1_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STAFF_RESTROOMS_2_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000000 | 9.96 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STORAGE_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000000 | 75.25 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000000 | 19.16 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_UTILITY_F1 ZN | VAV_1 | 0.000000 | 0.0000 | 0.000102 | 8.18 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_UTILITY_F2 ZN | VAV_2 | 0.000000 | 0.0000 | 0.000102 | 8.18 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_UTILITY_F3 ZN | VAV_3 | 0.000000 | 0.0000 | 0.000102 | 8.18 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| CB_UTILITY_F4 ZN | VAV_4 | 0.000000 | 0.0000 | 0.000102 | 8.18 | 0.0000 | 1.0000 | 0.0000 | 1.000 | 0.0000 |
| People Outdoor Air Rate - Rp [m3/s-person] | Sum of Zone Population - Pz-sum | Area Outdoor Air Rate - Ra [m3/s-m2] | Sum of Zone Floor Area - Az-sum [m2] | Breathing Zone Outdoor Airflow - Vbz [m3/s] | Cooling Zone Outdoor Airflow - Voz-clg [m3/s] | Heating Zone Outdoor Airflow - Voz-htg [m3/s] | |
| VAV_1 | 0.00 | 0.000011 | 1591.9865 | 0.0000 | 0.0000 | 0.0000 | |
| VAV_2 | 0.00 | 0.000009 | 1591.9865 | 0.0000 | 0.0000 | 0.0000 | |
| VAV_3 | 0.00 | 0.000009 | 1591.9865 | 0.0000 | 0.0000 | 0.0000 | |
| VAV_4 | 0.00 | 0.000013 | 1591.9865 | 0.0000 | 0.0000 | 0.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.4092 | 1.4092 | 0.0141 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2806 | 0.2806 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2807 | 0.2807 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4274 | 0.4274 | 0.0043 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2110 | 0.2110 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2110 | 0.2110 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3137 | 0.3137 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_3_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2106 | 0.2106 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_3_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2059 | 0.2059 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_3_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3055 | 0.3055 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_4_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2350 | 0.2350 | 0.0024 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_4_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2076 | 0.2076 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_4_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3121 | 0.3121 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_5_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1975 | 0.1975 | 0.0020 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_5_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1983 | 0.1983 | 0.0020 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_5_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3133 | 0.3133 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_6_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2121 | 0.2121 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_6_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2054 | 0.2054 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_6_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3808 | 0.3808 | 0.0038 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_7_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2226 | 0.2226 | 0.0022 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_7_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2124 | 0.2124 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_8_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3184 | 0.3184 | 0.0032 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_8_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3089 | 0.3089 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1967 | 0.1967 | 0.1231 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1326 | 0.1326 | 0.0821 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1323 | 0.1323 | 0.0819 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1512 | 0.1512 | 0.0824 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_ENTRANCE_LOBBY_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1298 | 0.1298 | 0.0013 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0502 | 0.0502 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0604 | 0.0604 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0503 | 0.0503 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0590 | 0.0590 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_3_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0503 | 0.0503 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_3_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_3_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0589 | 0.0589 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_4_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0503 | 0.0503 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_4_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_4_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0588 | 0.0588 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_5_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0503 | 0.0503 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_5_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_5_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0588 | 0.0588 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_6_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0503 | 0.0503 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_6_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_6_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0589 | 0.0589 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_7_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0503 | 0.0503 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_7_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0506 | 0.0506 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_7_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0590 | 0.0590 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_8_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0502 | 0.0502 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_8_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0507 | 0.0507 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_8_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0605 | 0.0605 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 1.0018 | 1.0018 | 0.0100 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7751 | 0.7751 | 0.0078 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_3_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7751 | 0.7751 | 0.0078 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_4_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9395 | 0.9395 | 0.0094 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LECTURE_ROOM_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9865 | 0.9865 | 0.0099 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LECTURE_ROOM_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5886 | 0.5886 | 0.0059 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7913 | 0.7913 | 0.1084 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0491 | 0.0491 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0489 | 0.0489 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0488 | 0.0488 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0488 | 0.0488 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0488 | 0.0488 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0488 | 0.0488 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0488 | 0.0488 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0487 | 0.0487 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3512 | 0.3512 | 0.0376 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3804 | 0.3804 | 0.0407 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3838 | 0.3838 | 0.0407 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4849 | 0.4849 | 0.0407 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9150 | 0.9150 | 0.0092 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8283 | 0.8283 | 0.0083 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.8063 | 0.8063 | 0.0081 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.9330 | 0.9330 | 0.0093 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0474 | 0.0474 | 0.0038 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0660 | 0.0660 | 0.0089 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3504 | 0.3504 | 0.0179 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1356 | 0.1356 | 0.0129 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2758 | 0.2758 | 0.0215 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0108 | 0.0108 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0104 | 0.0104 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0156 | 0.0156 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0107 | 0.0107 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0108 | 0.0108 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0152 | 0.0152 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0307 | 0.0307 | 0.0022 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0286 | 0.0286 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0286 | 0.0286 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0382 | 0.0382 | 0.0022 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0519 | 0.0519 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0495 | 0.0495 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0498 | 0.0498 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0610 | 0.0610 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0407 | 0.0407 | 0.0019 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0438 | 0.0438 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0442 | 0.0442 | 0.0019 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0549 | 0.0549 | 0.0019 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STAFF_RESTROOMS_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0108 | 0.0108 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STAFF_RESTROOMS_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0120 | 0.0120 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STORAGE_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3439 | 0.3439 | 0.0034 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0206 | 0.0206 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0193 | 0.0193 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0190 | 0.0190 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0275 | 0.0275 | 0.0003 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0235 | 0.0235 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0220 | 0.0220 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0219 | 0.0219 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0328 | 0.0328 | 0.0003 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1062 | 0.1062 | 0.0013 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0240 | 0.0240 | 0.0012 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0126 | 0.0126 | 0.0011 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0163 | 0.0163 | 0.0011 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Cooling - Voz-clg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| VAV_1 | 5.8347 | 5.6136 | 5.8347 | 0.3526 | 0.0000 | 1.0000 |
| VAV_2 | 4.8683 | 4.7943 | 4.8683 | 0.2026 | 0.0000 | 1.0000 |
| VAV_3 | 4.8232 | 4.7503 | 4.8232 | 0.2021 | 0.0000 | 1.0000 |
| VAV_4 | 7.1923 | 7.0244 | 7.1923 | 0.2311 | 0.0000 | 1.0000 |
| AirLoop Name | Box Type | Zone Primary Airflow - Vpz [m3/s] | Zone Discharge Airflow - Vdz [m3/s] | Minimum Zone Primary Airflow - Vpz-min [m3/s] | Is Vpz-min calculated using the Standard 62.1 Simplified Procedure? | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Primary Outdoor Air Fraction - Zpz | Primary Air Fraction - Ep | Secondary Recirculation Fraction- Er | Supply Air Fraction- Fa | Mixed Air Fraction - Fb | Outdoor Air Fraction - Fc | Zone Ventilation Efficiency - Evz | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.7046 | 0.7046 | 0.0141 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1403 | 0.1403 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1404 | 0.1404 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2137 | 0.2137 | 0.0043 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1055 | 0.1055 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1055 | 0.1055 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1569 | 0.1569 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_3_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1053 | 0.1053 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_3_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1029 | 0.1029 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_3_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1527 | 0.1527 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_4_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1175 | 0.1175 | 0.0024 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_4_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1038 | 0.1038 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_4_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1560 | 0.1560 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_5_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0987 | 0.0987 | 0.0020 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_5_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0991 | 0.0991 | 0.0020 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_5_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1567 | 0.1567 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_6_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1060 | 0.1060 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_6_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1027 | 0.1027 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_6_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1904 | 0.1904 | 0.0038 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_7_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1113 | 0.1113 | 0.0022 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_7_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1062 | 0.1062 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_8_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1592 | 0.1592 | 0.0032 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CLASSROOM_8_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1545 | 0.1545 | 0.0031 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1231 | 0.1231 | 0.1231 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0821 | 0.0821 | 0.0821 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0819 | 0.0819 | 0.0819 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CONFERENCE_ROOM_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0824 | 0.0824 | 0.0824 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_ENTRANCE_LOBBY_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0649 | 0.0649 | 0.0013 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0251 | 0.0251 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0302 | 0.0302 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0252 | 0.0252 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0295 | 0.0295 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_3_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0251 | 0.0251 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_3_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_3_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0294 | 0.0294 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_4_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0251 | 0.0251 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_4_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_4_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0294 | 0.0294 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_5_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0251 | 0.0251 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_5_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_5_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0294 | 0.0294 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_6_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0252 | 0.0252 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_6_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_6_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0294 | 0.0294 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_7_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0251 | 0.0251 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_7_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_7_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0295 | 0.0295 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_8_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0251 | 0.0251 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_8_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0253 | 0.0253 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_OFFICE_8_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0303 | 0.0303 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.5009 | 0.5009 | 0.0100 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3875 | 0.3875 | 0.0078 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_3_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3875 | 0.3875 | 0.0078 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LAB_4_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4698 | 0.4698 | 0.0094 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LECTURE_ROOM_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4932 | 0.4932 | 0.0099 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LECTURE_ROOM_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2943 | 0.2943 | 0.0059 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.3956 | 0.3956 | 0.1084 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0245 | 0.0245 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0029 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0244 | 0.0244 | 0.0028 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1756 | 0.1756 | 0.0376 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1902 | 0.1902 | 0.0407 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1919 | 0.1919 | 0.0407 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_OFFICES_OPEN_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.2425 | 0.2425 | 0.0407 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4575 | 0.4575 | 0.0092 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4141 | 0.4141 | 0.0083 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4031 | 0.4031 | 0.0081 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDIO_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.4665 | 0.4665 | 0.0093 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0237 | 0.0237 | 0.0038 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0330 | 0.0330 | 0.0089 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1752 | 0.1752 | 0.0179 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0678 | 0.0678 | 0.0129 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_CORRIDOR_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1379 | 0.1379 | 0.0215 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0054 | 0.0054 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0052 | 0.0052 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0078 | 0.0078 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0053 | 0.0053 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0054 | 0.0054 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0076 | 0.0076 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0153 | 0.0153 | 0.0022 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0143 | 0.0143 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0143 | 0.0143 | 0.0021 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_MAIN_STAIRS_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0191 | 0.0191 | 0.0022 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0260 | 0.0260 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0247 | 0.0247 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0249 | 0.0249 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0305 | 0.0305 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0203 | 0.0203 | 0.0019 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0219 | 0.0219 | 0.0018 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0221 | 0.0221 | 0.0019 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_SECONDARY_STAIRS_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0274 | 0.0274 | 0.0019 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STAFF_RESTROOMS_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0054 | 0.0054 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STAFF_RESTROOMS_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0060 | 0.0060 | 0.0001 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STORAGE_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.1720 | 0.1720 | 0.0034 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0103 | 0.0103 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0096 | 0.0096 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0095 | 0.0095 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0138 | 0.0138 | 0.0003 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0117 | 0.0117 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0110 | 0.0110 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0109 | 0.0109 | 0.0002 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0164 | 0.0164 | 0.0003 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F1 ZN | VAV_1 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0531 | 0.0531 | 0.0013 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F2 ZN | VAV_2 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0120 | 0.0120 | 0.0012 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F3 ZN | VAV_3 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0063 | 0.0063 | 0.0011 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| CB_UTILITY_F4 ZN | VAV_4 | AIRTERMINAL:SINGLEDUCT:VAV:REHEAT | 0.0082 | 0.0082 | 0.0011 | No | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 0.0000 | 1.0000 |
| Sum of Zone Primary Airflow - Vpz-sum [m3/s] | System Primary Airflow - Vps [m3/s] | Sum of Zone Discharge Airflow - Vdz-sum [m3/s] | Sum of Min Zone Primary Airflow - Vpz-min [m3/s] | Zone Outdoor Airflow Heating - Voz-htg [m3/s] | Zone Ventilation Efficiency - Evz-min | |
| VAV_1 | 2.9421 | 0.3526 | 0.3526 | 0.3526 | 0.0000 | 1.0000 |
| VAV_2 | 2.4499 | 0.2026 | 0.2026 | 0.2026 | 0.0000 | 1.0000 |
| VAV_3 | 2.4273 | 0.2021 | 0.2021 | 0.2021 | 0.0000 | 1.0000 |
| VAV_4 | 3.6029 | 0.2311 | 0.2311 | 0.2311 | 0.0000 | 1.0000 |
Report: LEED Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Sec1.1A-General Information| Data | |
| Weather File | TAMPA-MACDILL.AFB_FL_USA ANN HTG 99.6% CONDNS DB HVAC Sizing Pass 1 ** SINGAPORE - SGP IWEC Data WMO#=486980 |
| Total gross floor area [m2] | 6415.51 |
| Space Area [m2] | Regularly Occupied Area [m2] | Unconditioned Area [m2] | Typical Hours/Week in Operation [hr/wk] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 179.77 | 179.77 | 0.00 | 54.85 |
| CB_CLASSROOM_1_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_1_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_1_F4 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_CLASSROOM_2_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_2_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_2_F4 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_CLASSROOM_3_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_3_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_3_F4 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_CLASSROOM_4_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_4_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_4_F4 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_CLASSROOM_5_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_5_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_5_F4 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_CLASSROOM_6_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_6_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_6_F4 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_CLASSROOM_7_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_7_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_8_F2 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CLASSROOM_8_F3 ZN | 56.44 | 56.44 | 0.00 | 64.82 |
| CB_CONFERENCE_ROOM_F1 ZN | 45.99 | 45.99 | 0.00 | 64.82 |
| CB_CONFERENCE_ROOM_F2 ZN | 30.66 | 30.66 | 0.00 | 64.82 |
| CB_CONFERENCE_ROOM_F3 ZN | 30.66 | 30.66 | 0.00 | 64.82 |
| CB_CONFERENCE_ROOM_F4 ZN | 30.66 | 30.66 | 0.00 | 64.82 |
| CB_ENTRANCE_LOBBY_F1 ZN | 75.25 | 75.25 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_1_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_1_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_1_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_2_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_2_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_2_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_3_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_3_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_3_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_4_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_4_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_4_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_5_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_5_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_5_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_6_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_6_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_6_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_7_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_7_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_7_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_8_F2 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_8_F3 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_FACULTY_OFFICE_8_F4 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_LAB_1_F4 ZN | 135.17 | 135.17 | 0.00 | 68.54 |
| CB_LAB_2_F4 ZN | 135.17 | 135.17 | 0.00 | 68.54 |
| CB_LAB_3_F4 ZN | 135.17 | 135.17 | 0.00 | 68.54 |
| CB_LAB_4_F4 ZN | 135.17 | 135.17 | 0.00 | 68.54 |
| CB_LECTURE_ROOM_1_F1 ZN | 270.35 | 270.35 | 0.00 | 37.21 |
| CB_LECTURE_ROOM_2_F1 ZN | 150.50 | 150.50 | 0.00 | 64.82 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 270.35 | 270.35 | 0.00 | 37.21 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 12.26 | 12.26 | 0.00 | 64.82 |
| CB_OFFICES_OPEN_F1 ZN | 194.17 | 194.17 | 0.00 | 64.82 |
| CB_OFFICES_OPEN_F2 ZN | 209.50 | 209.50 | 0.00 | 64.82 |
| CB_OFFICES_OPEN_F3 ZN | 209.50 | 209.50 | 0.00 | 64.82 |
| CB_OFFICES_OPEN_F4 ZN | 209.50 | 209.50 | 0.00 | 64.82 |
| CB_STUDIO_1_F2 ZN | 299.61 | 299.61 | 0.00 | 61.02 |
| CB_STUDIO_1_F3 ZN | 299.61 | 299.61 | 0.00 | 61.02 |
| CB_STUDIO_2_F2 ZN | 299.61 | 299.61 | 0.00 | 61.02 |
| CB_STUDIO_2_F3 ZN | 299.61 | 299.61 | 0.00 | 61.02 |
| CB_CORRIDOR_1_F3 ZN | 31.59 | 31.59 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 61.32 | 61.32 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 122.17 | 122.17 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 92.90 | 92.90 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 151.43 | 151.43 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 18.58 | 18.58 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 18.58 | 18.58 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 18.58 | 18.58 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 18.58 | 18.58 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 12.54 | 12.54 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 9.96 | 9.96 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 75.25 | 75.25 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 19.16 | 19.16 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 8.18 | 8.18 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 8.18 | 8.18 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 8.18 | 8.18 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 8.18 | 8.18 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 11.89 | 0.00 | 11.89 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 11.89 | 0.00 | 11.89 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 11.89 | 0.00 | 11.89 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 11.89 | 0.00 | 11.89 | 0.00 |
| Totals | 6415.51 | 6367.95 | 47.57 |
| Data | |
| Number of hours heating loads not met | 0.00 |
| Number of hours cooling loads not met | 2275.17 |
| Number of hours not met | 2275.17 |
| Utility Rate | Virtual Rate [$/unit energy] | Units of Energy | Units of Demand | |
| None |
| Electricity Energy Use [GJ] | Electricity Demand [W] | Natural Gas Energy Use [GJ] | Natural Gas Demand [W] | Gasoline Use [GJ] | Gasoline Demand [W] | Diesel Use [GJ] | Diesel Demand [W] | Coal Use [GJ] | Coal Demand [W] | Fuel Oil No 1 Use [GJ] | Fuel Oil No 1 Demand [W] | Fuel Oil No 2 Use [GJ] | Fuel Oil No 2 Demand [W] | Propane Use [GJ] | Propane Demand [W] | Other Fuel 1 Use [GJ] | Other Fuel 1 Demand [W] | Other Fuel 2 Use [GJ] | Other Fuel 2 Demand [W] | District Cooling Use [GJ] | District Cooling Demand [W] | District Heating Use [GJ] | District Heating Demand [W] | |
| Heating -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heating -- Boiler Parasitic | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Cooling -- General | 783.39 | 66597.43 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Lighting -- General | 701.37 | 44856.37 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Lighting -- General | 70.69 | 8993.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- General | 1446.11 | 87310.39 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Interior Equipment -- Elevators | 73.12 | 9759.61 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Exterior Equipment -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Fans -- VAV System Fans | 369.81 | 51025.80 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Pumps -- General | 193.20 | 9770.17 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Rejection -- General | 115.68 | 13826.58 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Humidification -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Heat Recovery -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Water Systems -- General | 0.00 | 0.00 | 306.33 | 28778.77 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Refrigeration -- Not Subdivided | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Generators -- General | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Process Subtotal [GJ] | Total Energy Use [GJ] | |
| Electricity | 1519.23 | 3753.38 |
| Natural Gas | 0.00 | 306.33 |
| Additional | 0.00 | 0.00 |
| Total | 1519.23 | 4059.71 |
| Process Subtotal [$] | Total Energy Cost [$] | |
| Electricity | 0.00 | |
| Natural Gas | 0.00 | |
| Additional | 0.00 | |
| Total | 0.00 |
| Rated Capacity [kW] | Annual Energy Generated [GJ] | |
| Photovoltaic | 0.00 | 0.00 |
| Wind | 0.00 | 0.00 |
| Electricty [MJ/m2] | |
| Interior Lighting (All) | 109.32 |
| Space Heating | 0.00 |
| Space Cooling | 122.11 |
| Fans (All) | 57.64 |
| Service Water Heating | 0.00 |
| Receptacle Equipment | 236.81 |
| Miscellaneous (All) | 585.05 |
| Subtotal | 585.05 |
| Natural Gas [MJ/m2] | |
| Space Heating | 0.00 |
| Service Water Heating | 47.75 |
| Miscellaneous (All) | 47.75 |
| Subtotal | 47.75 |
| Additional [MJ/m2] | |
| Subtotal | 0.00 |
| Miscellaneous | 0.00 |
| Percent [%] | |
| Interior Lighting (All) | 17.28 |
| Space Heating | 0.00 |
| Space Cooling | 19.30 |
| Fans (All) | 9.11 |
| Service Water Heating | 7.55 |
| Receptacle Equipment | 37.42 |
| Miscellaneous | 9.35 |
| Equivalent Full Load Hours of Operation Per Year [hr] | Hours > 1% [hr] | |
| CB_CONFERENCE_ROOM_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 5292. | 8760. |
| CB_CONFERENCE_ROOM_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 5233. | 8760. |
| CB_CONFERENCE_ROOM_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 5233. | 8760. |
| CB_CONFERENCE_ROOM_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 4612. | 8760. |
| CB_FACULTY_OFFICE_1_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_1_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 515. | 8760. |
| CB_FACULTY_OFFICE_1_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 431. | 8760. |
| CB_FACULTY_OFFICE_2_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_2_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_2_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 448. | 8760. |
| CB_FACULTY_OFFICE_3_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_3_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_3_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 448. | 8760. |
| CB_FACULTY_OFFICE_4_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_4_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_4_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 448. | 8760. |
| CB_FACULTY_OFFICE_5_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_5_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_5_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 448. | 8760. |
| CB_FACULTY_OFFICE_6_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_6_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_6_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 448. | 8760. |
| CB_FACULTY_OFFICE_7_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_7_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_7_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 448. | 8760. |
| CB_FACULTY_OFFICE_8_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_FACULTY_OFFICE_8_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 515. | 8760. |
| CB_FACULTY_OFFICE_8_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 431. | 8760. |
| CB_OFFICES_ENCLOSED_1_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_OFFICES_ENCLOSED_2_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 540. | 8760. |
| CB_OFFICES_ENCLOSED_3_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 540. | 8760. |
| CB_OFFICES_ENCLOSED_4_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 540. | 8760. |
| CB_OFFICES_ENCLOSED_5_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 540. | 8760. |
| CB_OFFICES_ENCLOSED_6_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 540. | 8760. |
| CB_OFFICES_ENCLOSED_7_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 540. | 8760. |
| CB_OFFICES_ENCLOSED_8_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 523. | 8760. |
| CB_OFFICES_OPEN_F1 ZN VAV TERMINAL - MDP - ADJUSTED | 935. | 8760. |
| CB_OFFICES_OPEN_F2 ZN VAV TERMINAL - MDP - ADJUSTED | 935. | 8760. |
| CB_OFFICES_OPEN_F3 ZN VAV TERMINAL - MDP - ADJUSTED | 926. | 8760. |
| CB_OFFICES_OPEN_F4 ZN VAV TERMINAL - MDP - ADJUSTED | 742. | 8760. |
| First Object Used | Month Assumed | 11am First Wednesday [C] | Days with Same 11am Value | 11pm First Wednesday [C] | Days with Same 11pm Value | |
| COLLEGE HTGSETP_SCH | COLLEGE - LOUNGE THERMOSTAT 1 | January | 21.11 | 365 | 15.56 | 365 |
| COLLEGE CLGSETP_SCH | COLLEGE - LOUNGE THERMOSTAT 1 | July | 23.89 | 365 | 29.44 | 365 |
| COLLEGE HTGSETP_SCH - OCCUPANT STANDBY MODE | COLLEGE - CONFERENCE THERMOSTAT 1 | January | 21.11 | 365 | 15.56 | 365 |
| COLLEGE CLGSETP_SCH - OCCUPANT STANDBY MODE | COLLEGE - CONFERENCE THERMOSTAT 1 | July | 23.89 | 365 | 29.44 | 365 |
| COLLEGE HTGSETP_SCH_SETBACK | COLLEGE - RESTROOM THERMOSTAT 1 | January | 15.56 | 365 | 15.56 | 365 |
| COLLEGE CLGSETP_SCH_SETUP | COLLEGE - RESTROOM THERMOSTAT 1 | July | 29.44 | 365 | 29.44 | 365 |
Report: Annual CO2 Resilience Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
CO2 Level Hours| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
| Safe (<= 1000 ppm) [hr] | Caution (> 1000, <= 5000 ppm) [hr] | Hazard (> 5000 ppm) [hr] | |
| None |
Report: Annual Visual Resilience Summary
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Illuminance Level Hours| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_LAB_2_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_LAB_3_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_LAB_4_F4 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 8760.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 8760.00 | 0.00 |
| Average | 0.00 | 0.00 | 1647.18 | 0.00 |
| Sum | 0.00 | 0.00 | 192720.00 | 0.00 |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 78377.18 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 37407.30 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 37407.30 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 49876.40 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 49876.40 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 49876.40 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 49876.40 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 49876.40 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 49876.40 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 37407.30 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 37407.30 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 0.00 | 0.00 | 24353.79 | 0.00 |
| CB_LAB_2_F4 ZN | 0.00 | 0.00 | 24353.79 | 0.00 |
| CB_LAB_3_F4 ZN | 0.00 | 0.00 | 24353.79 | 0.00 |
| CB_LAB_4_F4 ZN | 0.00 | 0.00 | 24353.79 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 115956.52 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 99752.80 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 17839.46 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 51480.03 | 0.00 |
| CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 51480.03 | 0.00 |
| CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 51480.03 | 0.00 |
| CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 51480.03 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 115956.52 | 0.00 |
| Average | 0.00 | 0.00 | 9095.29 | 0.00 |
| Sum | 0.00 | 0.00 | 1064148.81 | 0.00 |
| A Bit Dark (<= 100 lux) [hr] | Dim (> 100, <= 300 lux) [hr] | Adequate (> 300, <= 500 lux) [hr] | Bright (>500 lux) [hr] | |
| CB_CAFE_STUDY_LOUNGE_F1 ZN | 0.00 | 0.00 | 2860.00 | 0.00 |
| CB_CLASSROOM_1_F2 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_1_F3 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_1_F4 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_2_F4 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_3_F4 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_4_F4 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_5_F4 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_6_F4 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CLASSROOM_8_F2 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CLASSROOM_8_F3 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_CONFERENCE_ROOM_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CONFERENCE_ROOM_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_ENTRANCE_LOBBY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_3_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_4_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_5_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_6_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_7_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_OFFICE_8_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_LAB_1_F4 ZN | 0.00 | 0.00 | 3574.00 | 0.00 |
| CB_LAB_2_F4 ZN | 0.00 | 0.00 | 3574.00 | 0.00 |
| CB_LAB_3_F4 ZN | 0.00 | 0.00 | 3574.00 | 0.00 |
| CB_LAB_4_F4 ZN | 0.00 | 0.00 | 3574.00 | 0.00 |
| CB_LECTURE_ROOM_1_F1 ZN | 0.00 | 0.00 | 1940.00 | 0.00 |
| CB_LECTURE_ROOM_2_F1 ZN | 0.00 | 0.00 | 3380.00 | 0.00 |
| CB_LIBRARY_MEDIA_CENTER_F1 ZN | 0.00 | 0.00 | 1940.00 | 0.00 |
| CB_OFFICES_ENCLOSED_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_3_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_4_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_5_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_6_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_7_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_ENCLOSED_8_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_OFFICES_OPEN_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDIO_1_F2 ZN | 0.00 | 0.00 | 3182.00 | 0.00 |
| CB_STUDIO_1_F3 ZN | 0.00 | 0.00 | 3182.00 | 0.00 |
| CB_STUDIO_2_F2 ZN | 0.00 | 0.00 | 3182.00 | 0.00 |
| CB_STUDIO_2_F3 ZN | 0.00 | 0.00 | 3182.00 | 0.00 |
| CB_CORRIDOR_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_CORRIDOR_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_FACULTY_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_MAIN_STAIRS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_SECONDARY_STAIRS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STAFF_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STORAGE_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_1_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_STUDENTS_RESTROOMS_2_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_UTILITY_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F1 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F2 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F3 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| CB_PUBLIC_ELEVATORS_F4 ZN | 0.00 | 0.00 | 0.00 | 0.00 |
| Min | 0.00 | 0.00 | 0.00 | 0.00 |
| Max | 0.00 | 0.00 | 3574.00 | 0.00 |
| Average | 0.00 | 0.00 | 606.36 | 0.00 |
| Sum | 0.00 | 0.00 | 70944.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY
For: Meter
Timestamp: 2023-09-09 10:58:41
Custom Monthly Report| INTERIORLIGHTS:ELECTRICITY [J] | EXTERIORLIGHTS:ELECTRICITY [J] | INTERIOREQUIPMENT:ELECTRICITY [J] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY [J] | PUMPS:ELECTRICITY [J] | HEATING:ELECTRICITY [J] | COOLING:ELECTRICITY [J] | HEATREJECTION:ELECTRICITY [J] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | REFRIGERATION:ELECTRICITY [] | |
| January | 0.636068E+11 | 0.608161E+10 | 0.137070E+12 | 0.00 | 0.375773E+11 | 0.178575E+11 | 0.00 | 0.723784E+11 | 0.121312E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 0.576856E+11 | 0.543945E+10 | 0.124059E+12 | 0.00 | 0.334432E+11 | 0.157750E+11 | 0.00 | 0.648264E+11 | 0.102467E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 0.654222E+11 | 0.601685E+10 | 0.139033E+12 | 0.00 | 0.351056E+11 | 0.169264E+11 | 0.00 | 0.710176E+11 | 0.102229E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 0.592126E+11 | 0.582259E+10 | 0.130115E+12 | 0.00 | 0.319058E+11 | 0.164816E+11 | 0.00 | 0.649729E+11 | 0.926534E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 0.654222E+11 | 0.585496E+10 | 0.139033E+12 | 0.00 | 0.389589E+11 | 0.178610E+11 | 0.00 | 0.753267E+11 | 0.106505E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 0.628433E+11 | 0.580100E+10 | 0.134010E+12 | 0.00 | 0.278412E+11 | 0.158411E+11 | 0.00 | 0.637437E+11 | 0.885899E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 0.382592E+11 | 0.586036E+10 | 0.879592E+11 | 0.00 | 0.158615E+11 | 0.123725E+11 | 0.00 | 0.499393E+11 | 0.655934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 0.396488E+11 | 0.594130E+10 | 0.896540E+11 | 0.00 | 0.157020E+11 | 0.125925E+11 | 0.00 | 0.515235E+11 | 0.689871E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 0.610280E+11 | 0.581719E+10 | 0.132078E+12 | 0.00 | 0.313870E+11 | 0.161345E+11 | 0.00 | 0.647910E+11 | 0.990794E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 0.636068E+11 | 0.606542E+10 | 0.137070E+12 | 0.00 | 0.354307E+11 | 0.175490E+11 | 0.00 | 0.711095E+11 | 0.104531E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 0.628433E+11 | 0.591432E+10 | 0.134042E+12 | 0.00 | 0.344390E+11 | 0.167233E+11 | 0.00 | 0.679409E+11 | 0.989864E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 0.617914E+11 | 0.607621E+10 | 0.135107E+12 | 0.00 | 0.321572E+11 | 0.170899E+11 | 0.00 | 0.658245E+11 | 0.105849E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.701370E+12 | 0.706913E+11 | 0.151923E+13 | 0.00 | 0.369810E+12 | 0.193204E+12 | 0.00 | 0.783395E+12 | 0.115678E+12 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Minimum of Months | 0.382592E+11 | 0.543945E+10 | 0.879592E+11 | 0.00 | 0.157020E+11 | 0.123725E+11 | 0.00 | 0.499393E+11 | 0.655934E+10 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maximum of Months | 0.654222E+11 | 0.608161E+10 | 0.139033E+12 | 0.00 | 0.389589E+11 | 0.178610E+11 | 0.00 | 0.753267E+11 | 0.121312E+11 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - NATURAL GAS
For: Meter
Timestamp: 2023-09-09 10:58:41
Custom Monthly Report| INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS [J] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS [J] | COGENERATION:NATURALGAS [] | |
| January | 0.00 | 0.00 | 0.00 | 0.00 | 0.264076E+11 | 0.00 |
| February | 0.00 | 0.00 | 0.00 | 0.00 | 0.238565E+11 | 0.00 |
| March | 0.00 | 0.00 | 0.00 | 0.00 | 0.264220E+11 | 0.00 |
| April | 0.00 | 0.00 | 0.00 | 0.00 | 0.250418E+11 | 0.00 |
| May | 0.00 | 0.00 | 0.00 | 0.00 | 0.259904E+11 | 0.00 |
| June | 0.00 | 0.00 | 0.00 | 0.00 | 0.249412E+11 | 0.00 |
| July | 0.00 | 0.00 | 0.00 | 0.00 | 0.254847E+11 | 0.00 |
| August | 0.00 | 0.00 | 0.00 | 0.00 | 0.257388E+11 | 0.00 |
| September | 0.00 | 0.00 | 0.00 | 0.00 | 0.248836E+11 | 0.00 |
| October | 0.00 | 0.00 | 0.00 | 0.00 | 0.259581E+11 | 0.00 |
| November | 0.00 | 0.00 | 0.00 | 0.00 | 0.254236E+11 | 0.00 |
| December | 0.00 | 0.00 | 0.00 | 0.00 | 0.261797E+11 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.306328E+12 | 0.00 |
| Minimum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.238565E+11 | 0.00 |
| Maximum of Months | 0.00 | 0.00 | 0.00 | 0.00 | 0.264220E+11 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - ELECTRICITY PEAK DEMAND
For: Meter
Timestamp: 2023-09-09 10:58:41
Custom Monthly Report| ELECTRICITY:FACILITY {Maximum} [W] | ELECTRICITY:FACILITY {TIMESTAMP} | INTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | EXTERIORLIGHTS:ELECTRICITY {AT MAX/MIN} [W] | INTERIOREQUIPMENT:ELECTRICITY {AT MAX/MIN} [W] | EXTERIOREQUIPMENT:ELECTRICITY [] | FANS:ELECTRICITY {AT MAX/MIN} [W] | PUMPS:ELECTRICITY {AT MAX/MIN} [W] | HEATING:ELECTRICITY {AT MAX/MIN} [W] | COOLING:ELECTRICITY {AT MAX/MIN} [W] | HEATREJECTION:ELECTRICITY {AT MAX/MIN} [W] | HUMIDIFIER:ELECTRICITY [] | HEATRECOVERY:ELECTRICITY [] | WATERSYSTEMS:ELECTRICITY [] | COGENERATION:ELECTRICITY [] | |
| January | 280058.10 | 02-JAN-08:30 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50419.95 | 9770.17 | 0.00 | 64115.03 | 13826.58 | 0.00 | 0.00 | 0.00 | 0.00 |
| February | 280650.97 | 20-FEB-14:19 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50686.28 | 9770.17 | 0.00 | 64441.57 | 13826.58 | 0.00 | 0.00 | 0.00 | 0.00 |
| March | 288081.11 | 20-MAR-07:20 | 44856.37 | 8993.80 | 97070.00 | 0.00 | 50513.43 | 9770.17 | 0.00 | 64231.11 | 12646.23 | 0.00 | 0.00 | 0.00 | 0.00 |
| April | 281299.34 | 24-APR-09:19 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50360.14 | 9770.17 | 0.00 | 66198.83 | 13043.83 | 0.00 | 0.00 | 0.00 | 0.00 |
| May | 281898.10 | 08-MAY-10:30 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50003.90 | 9770.17 | 0.00 | 66596.10 | 13601.56 | 0.00 | 0.00 | 0.00 | 0.00 |
| June | 276930.76 | 05-JUN-07:20 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50001.23 | 9770.17 | 0.00 | 65673.88 | 9559.11 | 0.00 | 0.00 | 0.00 | 0.00 |
| July | 205645.77 | 24-JUL-07:20 | 24920.20 | 0.00 | 53414.81 | 0.00 | 43033.57 | 9626.12 | 0.00 | 65144.48 | 9506.59 | 0.00 | 0.00 | 0.00 | 0.00 |
| August | 204218.60 | 07-AUG-07:20 | 24920.20 | 0.00 | 53414.81 | 0.00 | 42715.15 | 9537.74 | 0.00 | 63810.26 | 9820.44 | 0.00 | 0.00 | 0.00 | 0.00 |
| September | 280371.24 | 25-SEP-13:09 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50192.57 | 9770.17 | 0.00 | 64757.55 | 13724.57 | 0.00 | 0.00 | 0.00 | 0.00 |
| October | 281111.23 | 09-OCT-09:19 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50782.61 | 9770.17 | 0.00 | 65962.02 | 12670.06 | 0.00 | 0.00 | 0.00 | 0.00 |
| November | 280857.46 | 20-NOV-14:30 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50955.98 | 9770.17 | 0.00 | 66047.16 | 12157.79 | 0.00 | 0.00 | 0.00 | 0.00 |
| December | 280830.76 | 25-DEC-14:49 | 44856.37 | 0.00 | 97070.00 | 0.00 | 50955.98 | 9770.17 | 0.00 | 64351.66 | 13826.58 | 0.00 | 0.00 | 0.00 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | ||||||||||
| Minimum of Months | 204218.60 | 24920.20 | 0.00 | 53414.81 | 0.00 | 42715.15 | 9537.74 | 0.00 | 63810.26 | 9506.59 | 0.00 | 0.00 | 0.00 | 0.00 | |
| Maximum of Months | 288081.11 | 44856.37 | 8993.80 | 97070.00 | 0.00 | 50955.98 | 9770.17 | 0.00 | 66596.10 | 13826.58 | 0.00 | 0.00 | 0.00 | 0.00 |
Report: BUILDING ENERGY PERFORMANCE - NATURAL GAS PEAK DEMAND
For: Meter
Timestamp: 2023-09-09 10:58:41
Custom Monthly Report| NATURALGAS:FACILITY {Maximum} [W] | NATURALGAS:FACILITY {TIMESTAMP} | INTERIOREQUIPMENT:NATURALGAS [] | EXTERIOREQUIPMENT:NATURALGAS [] | HEATING:NATURALGAS {AT MAX/MIN} [W] | COOLING:NATURALGAS [] | WATERSYSTEMS:NATURALGAS {AT MAX/MIN} [W] | COGENERATION:NATURALGAS [] | |
| January | 28778.77 | 24-JAN-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 28778.77 | 0.00 |
| February | 28776.50 | 01-FEB-13:49 | 0.00 | 0.00 | 0.00 | 0.00 | 28776.50 | 0.00 |
| March | 28748.53 | 01-MAR-13:49 | 0.00 | 0.00 | 0.00 | 0.00 | 28748.53 | 0.00 |
| April | 28680.97 | 03-APR-12:30 | 0.00 | 0.00 | 0.00 | 0.00 | 28680.97 | 0.00 |
| May | 28609.60 | 01-MAY-12:09 | 0.00 | 0.00 | 0.00 | 0.00 | 28609.60 | 0.00 |
| June | 28536.17 | 01-JUN-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 28536.17 | 0.00 |
| July | 28489.27 | 03-JUL-13:00 | 0.00 | 0.00 | 0.00 | 0.00 | 28489.27 | 0.00 |
| August | 28511.07 | 30-AUG-12:19 | 0.00 | 0.00 | 0.00 | 0.00 | 28511.07 | 0.00 |
| September | 28566.03 | 29-SEP-12:49 | 0.00 | 0.00 | 0.00 | 0.00 | 28566.03 | 0.00 |
| October | 28647.92 | 31-OCT-12:49 | 0.00 | 0.00 | 0.00 | 0.00 | 28647.92 | 0.00 |
| November | 28718.64 | 30-NOV-13:49 | 0.00 | 0.00 | 0.00 | 0.00 | 28718.64 | 0.00 |
| December | 28764.95 | 29-DEC-13:30 | 0.00 | 0.00 | 0.00 | 0.00 | 28764.95 | 0.00 |
| Annual Sum or Average | 0.00 | 0.00 | 0.00 | 0.00 | ||||
| Minimum of Months | 28489.27 | 0.00 | 0.00 | 0.00 | 0.00 | 28489.27 | 0.00 | |
| Maximum of Months | 28778.77 | 0.00 | 0.00 | 0.00 | 0.00 | 28778.77 | 0.00 |
Report: Life-Cycle Cost Report
For: Entire Facility
Timestamp: 2023-09-09 10:58:41
Life-Cycle Cost Parameters| Value | |
| Name | LIFE CYCLE COST PARAMETERS |
| Discounting Convention | EndOfYear |
| Inflation Approach | ConstantDollar |
| Real Discount Rate | 0.0300 |
| Nominal Discount Rate | -- N/A -- |
| Inflation | -- N/A -- |
| Base Date | January 2011 |
| Service Date | January 2011 |
| Length of Study Period in Years | 25 |
| Tax rate | 0.0000 |
| Depreciation Method | None |
| U.S. AVG COMMERCIAL-ELECTRICITY | U.S. AVG COMMERCIAL-DISTILLATE OIL | U.S. AVG COMMERCIAL-RESIDUAL OIL | U.S. AVG COMMERCIAL-NATURAL GAS | U.S. AVG COMMERCIAL-COAL | |
| Resource | Electricity | FuelOilNo1 | FuelOilNo2 | NaturalGas | Coal |
| Start Date | January 2011 | January 2011 | January 2011 | January 2011 | January 2011 |
| 1 | 0.983800 | 0.971400 | 0.846900 | 0.982300 | 0.997000 |
| 2 | 0.973000 | 0.973000 | 0.825700 | 0.955700 | 1.008900 |
| 3 | 0.963200 | 0.994200 | 0.868100 | 0.927900 | 1.008900 |
| 4 | 0.961100 | 1.016400 | 0.898800 | 0.925700 | 0.994100 |
| 5 | 0.957100 | 1.054100 | 0.928900 | 0.934600 | 0.994100 |
| 6 | 0.955300 | 1.092800 | 0.960400 | 0.941200 | 1.000000 |
| 7 | 0.953900 | 1.126700 | 0.989700 | 0.951200 | 1.003000 |
| 8 | 0.952100 | 1.158000 | 1.007500 | 0.964500 | 1.005900 |
| 9 | 0.954600 | 1.179200 | 1.031400 | 0.985600 | 1.008900 |
| 10 | 0.955000 | 1.196700 | 1.055400 | 1.006700 | 1.011900 |
| 11 | 0.955300 | 1.220000 | 1.086100 | 1.022200 | 1.014800 |
| 12 | 0.956400 | 1.233300 | 1.127800 | 1.041000 | 1.017800 |
| 13 | 0.957500 | 1.256600 | 1.149700 | 1.061000 | 1.020800 |
| 14 | 0.959600 | 1.270900 | 1.162000 | 1.078700 | 1.026700 |
| 15 | 0.961800 | 1.282600 | 1.174300 | 1.094200 | 1.029700 |
| 16 | 0.961400 | 1.298500 | 1.185200 | 1.109800 | 1.035600 |
| 17 | 0.961800 | 1.310200 | 1.194800 | 1.122000 | 1.041500 |
| 18 | 0.961800 | 1.325000 | 1.203700 | 1.130800 | 1.053400 |
| 19 | 0.959300 | 1.326100 | 1.207100 | 1.138600 | 1.056400 |
| 20 | 0.958900 | 1.328200 | 1.211900 | 1.148600 | 1.059300 |
| 21 | 0.960700 | 1.332400 | 1.213900 | 1.161900 | 1.065300 |
| 22 | 0.962500 | 1.335600 | 1.219400 | 1.176300 | 1.071200 |
| 23 | 0.965000 | 1.343100 | 1.227600 | 1.191800 | 1.074200 |
| 24 | 0.970800 | 1.351000 | 1.236500 | 1.211800 | 1.080100 |
| 25 | 0.975100 | 1.356800 | 1.242000 | 1.228400 | 1.083100 |
| DEFAULT COST | |
| Nonrecurring | |
| January 2011 | 0.00 |
| January 2012 | 0.00 |
| January 2013 | 0.00 |
| January 2014 | 0.00 |
| January 2015 | 0.00 |
| January 2016 | 0.00 |
| January 2017 | 0.00 |
| January 2018 | 0.00 |
| January 2019 | 0.00 |
| January 2020 | 0.00 |
| January 2021 | 0.00 |
| January 2022 | 0.00 |
| January 2023 | 0.00 |
| January 2024 | 0.00 |
| January 2025 | 0.00 |
| January 2026 | 0.00 |
| January 2027 | 0.00 |
| January 2028 | 0.00 |
| January 2029 | 0.00 |
| January 2030 | 0.00 |
| January 2031 | 0.00 |
| January 2032 | 0.00 |
| January 2033 | 0.00 |
| January 2034 | 0.00 |
| January 2035 | 0.00 |
| Total | |
| January 2011 | 0.00 |
| January 2012 | 0.00 |
| January 2013 | 0.00 |
| January 2014 | 0.00 |
| January 2015 | 0.00 |
| January 2016 | 0.00 |
| January 2017 | 0.00 |
| January 2018 | 0.00 |
| January 2019 | 0.00 |
| January 2020 | 0.00 |
| January 2021 | 0.00 |
| January 2022 | 0.00 |
| January 2023 | 0.00 |
| January 2024 | 0.00 |
| January 2025 | 0.00 |
| January 2026 | 0.00 |
| January 2027 | 0.00 |
| January 2028 | 0.00 |
| January 2029 | 0.00 |
| January 2030 | 0.00 |
| January 2031 | 0.00 |
| January 2032 | 0.00 |
| January 2033 | 0.00 |
| January 2034 | 0.00 |
| January 2035 | 0.00 |
| Total | |
| January 2011 | 0.00 |
| January 2012 | 0.00 |
| January 2013 | 0.00 |
| January 2014 | 0.00 |
| January 2015 | 0.00 |
| January 2016 | 0.00 |
| January 2017 | 0.00 |
| January 2018 | 0.00 |
| January 2019 | 0.00 |
| January 2020 | 0.00 |
| January 2021 | 0.00 |
| January 2022 | 0.00 |
| January 2023 | 0.00 |
| January 2024 | 0.00 |
| January 2025 | 0.00 |
| January 2026 | 0.00 |
| January 2027 | 0.00 |
| January 2028 | 0.00 |
| January 2029 | 0.00 |
| January 2030 | 0.00 |
| January 2031 | 0.00 |
| January 2032 | 0.00 |
| January 2033 | 0.00 |
| January 2034 | 0.00 |
| January 2035 | 0.00 |
| Construction | Salvage | OtherCapital | Total | |
| January 2011 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maintenance | Repair | Operation | Replacement | MinorOverhaul | MajorOverhaul | OtherOperational | Water | Energy | Total | |
| January 2011 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Maintenance | Repair | Operation | Replacement | MinorOverhaul | MajorOverhaul | OtherOperational | Water | Energy | Total | |
| January 2011 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| January | February | March | April | May | June | July | August | September | October | November | December | |
| 2011 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2012 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2013 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2014 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2015 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2016 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2017 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2018 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2019 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2020 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2021 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2022 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2023 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2024 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2025 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2026 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2027 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2028 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2029 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2030 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2031 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2032 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2033 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2034 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| 2035 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 | 0.00 |
| Category | Kind | Cost | Present Value | Present Value Factor | |
| DEFAULT COST | Construction | Nonrecurring | 0.00 | 0.00 | - |
| TOTAL | 0.00 |
| Present Value | |
| Maintenance | 0.00 |
| Repair | 0.00 |
| Operation | 0.00 |
| Replacement | 0.00 |
| Minor Overhaul | 0.00 |
| Major Overhaul | 0.00 |
| Other Operational | 0.00 |
| Water | 0.00 |
| Energy | 0.00 |
| Total Operation | 0.00 |
| Construction | 0.00 |
| Salvage | 0.00 |
| Other Capital | 0.00 |
| Total Capital | 0.00 |
| Total Energy | 0.00 |
| Grand Total | 0.00 |
| Total Cost (Without Escalation) | Total Cost (With Escalation) | Present Value of Costs | |
| January 2011 | 0.00 | 0.00 | 0.00 |
| January 2012 | 0.00 | 0.00 | 0.00 |
| January 2013 | 0.00 | 0.00 | 0.00 |
| January 2014 | 0.00 | 0.00 | 0.00 |
| January 2015 | 0.00 | 0.00 | 0.00 |
| January 2016 | 0.00 | 0.00 | 0.00 |
| January 2017 | 0.00 | 0.00 | 0.00 |
| January 2018 | 0.00 | 0.00 | 0.00 |
| January 2019 | 0.00 | 0.00 | 0.00 |
| January 2020 | 0.00 | 0.00 | 0.00 |
| January 2021 | 0.00 | 0.00 | 0.00 |
| January 2022 | 0.00 | 0.00 | 0.00 |
| January 2023 | 0.00 | 0.00 | 0.00 |
| January 2024 | 0.00 | 0.00 | 0.00 |
| January 2025 | 0.00 | 0.00 | 0.00 |
| January 2026 | 0.00 | 0.00 | 0.00 |
| January 2027 | 0.00 | 0.00 | 0.00 |
| January 2028 | 0.00 | 0.00 | 0.00 |
| January 2029 | 0.00 | 0.00 | 0.00 |
| January 2030 | 0.00 | 0.00 | 0.00 |
| January 2031 | 0.00 | 0.00 | 0.00 |
| January 2032 | 0.00 | 0.00 | 0.00 |
| January 2033 | 0.00 | 0.00 | 0.00 |
| January 2034 | 0.00 | 0.00 | 0.00 |
| January 2035 | 0.00 | 0.00 | 0.00 |
| TOTAL | 0.00 |